V2 Vulcan User manual

Value moves the world
ZIS142
IL 245
EDIZ. 08/05/2017
VULCAN
GB
IRREVERSIBLE
ELECTROMECHANICAL
ACTUATOR (UNDERGROUND
INSTALLATION) FOR LEAF GATES

147,5
200
224
343
37,5

ENGLISH
- 7 -
EU DECLARATION OF CONFORMITY AND
DECLARATION OF INCORPORATION OF
PARTLY COMPLETED MACHINE
Declaration in accordance with Directives: 2014/35/UE (LVD);
2014/30/UE (EMC); 2006/42/CE (MD) ANNEX II, PART B
The manufacturer V2 S.p.A., headquarters in
Corso Principi di Piemonte 65, 12035, Racconigi (CN), Italy
Under its sole responsibility hereby declares that:
the partly completed machinery model(s):
VULCAN-230V, VULCAN-230V-S, VULCAN-120V, VULCAN-24V
Description: electromechanical actuator for gates
• is intended to be installed on gates, to create a machine
according to the provisions of the Directive 2006/42/EC.
The machinery must not be put into service until the final
machinery into which it has to be incorporated has been
declared in conformity with the provisions of the Directive
2006/42/EC (annex II-A).
• is compliant with the applicable essential safety requirements
of the following Directives:
Machinery Directive 2006/42/EC (annex I, chapter 1)
Low Voltage Directive 2014/35/EU
Electromagnetic Compatibility Directive 2014/30/EU
Directive ROHS2 2011/65/CE
The relevant technical documentation is available at the national
authorities’ request after justifiable request to:
V2 S.p.A., Corso Principi di Piemonte 65,
12035, Racconigi (CN), Italy
The person empowered to draw up the declaration and to provide
the technical documentation:
Giuseppe Pezzetto
Legal representative of V2 S.p.A.
Racconigi, il 01/06/2015
TECHNICAL ASSISTANCE SERVICE
For any installation problem please contact our Customer Service
at the number +39-0172.812411 operating Monday to Friday
from 8:30 to 12:30 and from 14:00 to 18:00.
IMPORTANT REMARKS
V2 S.p.A. has the right to modify the product without
previous notice; it also declines any responsibility to
damage or injury to people or things caused by improper
use or wrong installation.
m Please read this instruction manual very carefully
before installing and programming your control unit.
• This instruction manual is only for qualified technicians, who
specialize in installations and automations.
• The contents of this instruction manual do not concern the end
user.
• Every programming and/or every maintenance service should
be done only by qualified technicians.
AUTOMATION MUST BE IMPLEMENTED IN COMPLIANCE
WITH THE EUROPEAN REGULATIONS IN FORCE:
EN 60204-1 (Machinery safety. electrical equipment of
machines, part 1: general rules)
EN 12445 (Safe use of automated locking devices, test
methods)
EN 12453 (Safe use of automated locking devices,
requirements)
• The installer must provide for a device (es. magnetotermical
switch) ensuring the omnipolar sectioning of the equipment
from the power supply.
The standards require a separation of the contacts of at
least 3 mm in each pole (EN 60335-1).
• The plastic case has an IP55 insulation; to connect flexible or
rigid pipes, use pipefittings having the same insulation level.
• Installation requires mechanical and electrical skills, therefore it
shall be carried out by qualified personnel only, who can issue
the Compliance Certificate concerning the whole installation
(Machine Directive 98/37/EEC, Annex IIA).
• The automated vehicular gates shall comply with the following
rules: EN 12453, EN 12445, EN 12978 as well as any local rule
in force.
• Also the automation upstream electric system shall comply with
the laws and rules in force and be carried out workmanlike.
• The door thrust force adjustment shall be measured by means
of a proper tool and adjusted according to the max. limits,
which EN 12453 allows.
• We recommend to make use of an emergency button, to be
installed by the automation (connected to the control unit
STOP input) so that the gate may be immediately stopped in
case of danger.
• The appliance is not to be used by children or persons with
reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given
supervision or instruction.
• Children being supervised do not play with the appliance.

ENGLISH
- 8 -
TECHNICAL DATA
* WARNING: if it is installed the accessory device for opening up to 180° (code 162218), the maximum length of the wing is
2,5m for a maximum weight of 400Kg
Max. leaf weight (Kg)
Max. leaf lenght (m)
VULCAN-24V VULCAN-120V VULCAN-230V VULCAN-230V-S
Max. leaf lenght* m x Kg 2 x 600
2,5 x 500
3 x 400
3,5 x 350
2 x 800
2,5 x 550
3 x 400
3,5 x 350
2 x 800
2,5 x 550
3 x 400
3,5 x 350
2 x 800
2,5 x 550
3 x 400
3,5 x 350
Power supply V / Hz 24 120 / 60 230 / 50 230 / 50
Idling current A 1 3 1,5 1,5
Maximum current
absorption
A 15 4,8 2,4 2
Maximum power W - 550 550 460
Nominal power W 230 350 350 350
Capacitor μF - 35 14 14
Opening time (90°) s 15 ÷ 25 15 17 28
Maximum torque N m 320 320 320 300
Working temperature °C -20 ÷ +55 -20 ÷ +55 20 ÷ +55 20 ÷ +55
Thermal protection °C - 150 150 150
Working cycle % 80 30 30 30
Motor weight Kg 11,5 11 11 11
Protection IP 67 67 67 67

ENGLISH
- 9 -
PREPARATORY STEPS
The new series of actuadors VULCAN, has been devised to serve
gates up to 800 Kg with leaf up to 3 meters wide (look at the
table technical data). Before proceeding with the installation,
please make sure that your gate opens and closes freely, and that:
• Hinges and pins are in optimum condition and properly
greased.
• No obstacles are within the moving area.
• There is no friction with the ground or between the leaves.
• The stop limit switch must be installed inside the foundation
box (see paragraph about Installation of the stop limit switches)
INSTALLATION LAYOUT
1 1
2
4
3
C
5D
A
B
LENGTH OF THE CABLE < 10 metres from 10 to 20 metres from 20 to 30 metres
Power supply 230V 3G x 1,5 mm23G x 1,5 mm23G x 2,5 mm2
Photocells (TX) 2 x 0,5 mm22 x 0,5 mm22 x 0,5 mm2
Key switch 4 x 0,5 mm24 x 0,5 mm24 x 0,5 mm2
Photocells (RX) 2 x 0,5 mm22 x 0,5 mm22 x 0,5 mm2
Flashing light 2 x 1,5 mm22 x 1,5 mm22 x 1,5 mm2
Antenna (integrated into the flashing light) RG174 RG174 RG174
A
B
C
D
1
2
3
4
5
Key switch
Pillar photocells
Pillar-mounted digital radio switch
Safety edges
Motor
Transmitter
Control unit
Photocells
Flashing light
COMPONENTS ADDITIONAL ACCESSORIES

ENGLISH
- 10 -
POSITIONING THE FOUNDATION BOX AND THE LEVER CONTROL
AND BLOCKING SYSTEM
250 mm
600 mm
450 mm 450 mm
600
mm
4
5
0
m
m
3 mm
3
m
m
> 67 mm
1. Depending on the dimensions, dig a suitably sized foundation
ditch (it is recommended to provide adequate drainage in order
to avoid water pooling).
2. Place the foundation box inside the trench, with the support
pivot aligned with the hinge axis.
3. Install a conduit for the electrical cables, and another for
drainage.
4. Embed the foundation box in concrete, ensuring it is level and
plumb.
mWARNING: ensure that the concrete used is properly
cured prior to proceeding with the following steps.
5. Insert the control rod Aover the foundation box supporting
pivot B.
6. Insert the ball Einto the special hole after having greased it
7. Fix with a strong welding the wing of the gate on the release
lever C, then put everything on the driving bracket Ain
correspondence of the hole
8. Grease the mechanism using the appropriate grease nipple D

ENGLISH
- 11 -
INSTALLING THE MOTOR REDUCER
1. Place the motor reducer gear unit inside the foundation box.
2. Fix the motor reducer in place inside the foundation box by
tightening the 4 nuts.
INSTALLATION OF THE STOP LIMIT SWITCHES
1. Place the gate in the maximum closed position, and then
attach the limit switch screw as shown in the figure.
2. Place the gate in the maximum open position, and then attach
the limit switch nut as shown in the figure, and tighten the
screw.
3. Mount the motor connecting rod on the motor drive shaft and
fix the screw in place using the corresponding self-locking nut.
4. Connect the motor connecting rod to the control rod by means
of the elbow lever.
5. Connect the motor to the control unit, following the
instructions in the following paragraph.

ENGLISH
- 12 -
mWARNING: Always connect the earth cable to the
mains power earth system. Use the special fastom shown in
the figure, and a cable with a minimum cross sectional area
of 2.5 mm2
VULCAN-24V
ELECTRICAL CONNECTIONS
VULCAN-230V / VULCAN-120V
ENCODER CONNECTION
To connect the encoders please refer to the control unit manual.
mWARNING: For the encoders to work properly it is
essential that the stoppers inside the case are installed
correctly.
mATTENTION: DO NOT use the motor cable channel for
the sensor cables.
mATTENTION: extensions of the cables must be made
only with a 4x0,22 shielded cable with polyethylene sheath
mATTENTION: connect the shielding braith sheath to the
common accessories. Check that the ground of the power
supply of the accessories is connected to the common
accessories.
Motor cable CONTROL UNIT
DX motor SX motor
YELLOW - GREEN GND GND
GREY COMMON COMMON
BLACK OPENING CLOSING
BROWN CLOSING OPENING
Motor cable CONTROL UNIT
DX motor SX motor
BLUE + -
BROWN - +
SX DX
EMERGENCY UNBLOCKING
In the case of a power failure, the gate can be unblocked
mechanically by operating the motor.
Insert the supplied unblocking lever and rotate 180° clockwise.
Automation will be automatically restored the first time the motor
is operated.

Other manuals for Vulcan
1
Table of contents
Other V2 Garage Door Opener manuals
Popular Garage Door Opener manuals by other brands

Merlin
Merlin Commander Elite MS105MYQ Installation and operating instructions

Chamberlain
Chamberlain T installation manual

ALSE
ALSE Stocco 5000 user manual

BFT
BFT PHOBOS BT A40 installation manual

Craftsman
Craftsman 39535006 owner's manual

CornellCookson
CornellCookson SDT-5045 Installation instructions and operation manual

Chamberlain
Chamberlain Passport user manual

BFT
BFT WIND RMB Series manual

Chamberlain
Chamberlain C253 owner's manual

Superlift
Superlift SDO-3DC Installation instructions and user guide

Assa Abloy
Assa Abloy Norton Double D6011 Series installation instructions

SCS