Legacy configuration codes Valid from 25th February 2003
HMP235 Humidity and Temperature Transmitter
With high temperature probe
Industrial humidity and temperature transmitter HMP235 PRICE
Transmitter RH+T A
type RH+T+Td B
RH+T+a+Tw+x C
RH+T+Td+a+Tw+x+h
RH+T+h F
Display no display
display on transmitter cover
Probe cable length 2 m cable, +180 °C (+356 °F) A
5 m cable, +180 °C (+356 °F)
10 m cable, +180 °C (+356 °F) C
Power supply, 24 V, no connectors
alarm output & 115 V, no connectors 1
connectors 230 V, no connectors 2
24 V, + alarm output unit (no connectors) 3
24 V, shared connector for power supply and analog outputs 4
24 V, as above + alarm output unit not on connector 5
115 V, connector for analog outputs 6
230 V, connector for analog outputs 7
Using serial interface: 24 V, connector for RS232C 8
24 V, 2 connectors: RS232C and analog outputs+power supply 9
24 V, 2 connectors shared for power supply and RS485 9
Serial interface RS 232C A
RS 485/RS 422 B
current loop C
Sensor protection sintered stainless steel filter (16452) 1
PPS plastic grid & stainless steel netting (16720HM) 2
Analog output 4...20 mA
signals 0...20 mA B B
(Ch1 and Ch2) 0...1 V C C
0...5 V D D
0...10 V
E
channel 1
channel 2
Parameters for the RH (0...100 %RH) 1 1
analog outputs T (range: see below) 2 2
(If available in the Td (-40...+100 °C) (-40...+212 °F) 3 3
chosen transmitter a (0...600 g/m3) (0...+262 gr/ft3) 4 4
type) Tw (0...+100 °C) (+32...+212 °F) 5 5
x (0...500 g/kg d.a.) (0...3500 gr/lb d.a.) 6 6
h (-40...1500 kJ/kg) (-17.2...644.9 Btu/lb) 7 7
(Ch1 and Ch2) channel 1
channel 2
Analog output range -20...+180 °C (-4...+356 °F)
for temperature 0...+180 °C (+32...+356 °F) B
Units (local display metric 1
and serial interface) non-metric 2
Installation kit no installation kit
aluminium flange B
steel flange
Regaining option *) no regaining (HUMICAP K) 3
and sensor type regaining (HUMICAP KC) 2
Manual language No manual A
English B
German C
French D
Finnish E
OTAL
*) Humidity sensor regaining can be used to reduce the effects of some chemical contaminants.
TY
If the regaining option is chosen, the sensor must be protected either with a sintered filter or
OTAL VALUE
with a PPS plastic grid with steel netting; the PPS plastic grid can not be used.
Please note that if mains power (115/230V) is selected regaining cannot be used.
For further information about this option, please see product data sheet or contact Your Vaisala representative.
Selections in bold are included in the prices of the basic versions.
Selections in italic are available at an extra price. Example of order code with typical settings:
HMP235 A