Features
1. Energy saving fixture.
2. Use the dim-to-bright illumination option where
you want some minimum illumination through out
the night, such as at your front entrance or garage
door. Use the dark-to-bright illumination option
where you do not need minimum brightness, such
as the backyard or back porch.
3. When in manual override mode, use wall switch
to keep the light ON till dawn.
191205
Important to Know
1. Read all instructions carefully before installation and operation.
2. If you are not familiar with state and local electrical codes, it is
recommended that you consult with a qualified electrician.
3. Before installation, shut off power at the main fuse or circuit
breaker box. Be aware that simply turning off the wall switch is
not sufficient to prevent an electrical shock.
4. This fixture requires a 120 VAC, 60 Hz power source.
5. Do not attempt to take the lantern apart; there are no
serviceable parts inside.
6. To avoid sensor damage by lightning or electrical surge, make
sure the grounding wire is securely connected.
7. For general safety and to avoid any possible damage to the
sensor, be sure the power is switched "off" before replacing the
bulb.
8. Compatible with LED dimmable bulb.
Maximum Wattage: 60W Incandescent Bulb or 20W LED
Dimmable Bulb
Work Temperature: -4°F~104°F
Hardware Package (included)
Mounting Screw (B) Wire Connector (C)
Bolt Nut (D) Rubber Pad (E)
Cross Bar Unit (A)
Backplate
Bolt Nut (D)
Rubber Pad (E)
Socket
Glass Shade
Metal Frame
Clip x 3
Fixture
Set Screw x 3
Wire Connector (C)
House Grounding Wire
Outlet Box
Mounting Screw (B)
Green Grounding Screw
Headless Screw
Cross Bar Unit (A)
Fixture Wire
Fixture Grounding Wire
W
ASSEMBLY AND INSTALLATION
INSTRUCTIONS
T0542
WARNING: Turn off the main power at circuit breaker before installing fixture.
AVERTISSEMENT: Coupez la source d’alimentation principale au panneau
central de disjoncteurs avant d’installer le luminaire.
NOTE: 1. Before installing, consult local electrical codes for wiring and grounding requirements.
2. READ AND SAVE THESE INSTRUCTIONS.
Bulb T12 4” high or
Type A Max.60W
(not included)
Page 2/4 191205
Function and Operation
MODES OF OPERATION
Choose a mode by sliding the switch on the back of the sensor. when power is first applied, the light will turn on
immediately. Wait for 100 seconds to allow the sensor to warm up.
1. TEST MODE (daytime and nighttime operation)
● The light will turn to low-level brightness (0%~50% brightness). The light will turn to high-level brightness (100%
brightness) when motion is detected, and stay on as long as the motion is continuing. The light will revert to
low-level brightness about 5 seconds after motion is no longer detected.
2. 3H MODE (nighttime operation only)
● At dusk, the light will turn to high-level brightness (100% brightness). The light will turn to low-level brightness (0%
~50% brightness) automatically after 3 hours. The light will turn to high-level brightness (100% brightness) when
motion is detected, and stay on as long as the motion is continuing. When motion is no longer detected, the light
will remain on for the predetermined time you set (5~180 seconds), and then revert to low-level brightness you set.
● Light will turn off automatically at dawn, and return to 3 H mode at dusk.
3. 6H MODE (nighttime operation only)
● At dusk, the light will turn to high-level brightness (100% brightness). The light will turn to low-level brightness (0%
~50% brightness) automatically after 6 hours. The light will turn to high-level brightness (100% brightness) when
motion is detected, and stay on as long as the motion is continuing. When motion is no longer detected, the light
will remain on for the predetermined time you set (5~180 seconds), and then revert to
low-level brightness you set
● Light will turn off automatically at dawn, and return to 6 H mode at dusk.
Installation steps
1. Remove the two bolt nuts (D), the two rubber pads (E) and the cross bar unit (A) from the backplate.
2. Attach the cross bar unit (A) to the outlet box using two mounting screws (B). Adjust the length of the preinstalled
headless screws if necessary.
Note: Make sure that the headless screws are lined up horizontally to make the fixture level.
3. Remove the three set screws and the metal frame from the fixture .
4. Pull out the source wires from the outlet box. Make wire connections using wire connectors (C) as follows:
• Connect the hot wire (usually black insulation) from the fixture to the black wire from the power source.
• Connect the neutral wire (usually white insulation) from the fixture to the white wire from the power source.
• Attach the fixture grounding wire (usually green insulation or bare wire) to the cross bar unit (A) with the
green grounding screw. Then, depending on local code connect it to the house grounding wire with the wire
connector (C).
Carefully put all of the wires back into the outlet box.
5. Attach the backplate of the fixture to the cross bar unit (A) by aligning and inserting the two headless screws from
the cross bar unit (A) into the open holes on the backplate, then place the two rubber pads (E) over the exposed
headless screws before screwing the two bolt nuts (D).
Note: With silicone caulking compound, caulk completely around where the backplate meets with the wall
surface to prevent water from seeping into the outlet box.
6. Install bulb (not included). See relamping label at socket area or packaging for maximum wattage allowed .
7. Take the glass shade and gently slide the glass shade into the metal frame, then fix the glass shade with the three
clips.
8. Attach the metal frame to the fixture, then secure it with the three set screws.
Turn off the power at fuse or circuit box.
Turn on the power at fuse or circuit box.
Page 3/4 191205
CUSTOMIZATION OPTIONS:
Shut-off Delay
The Shut-off delay is the length of time the light will stay at high-level brightness after motion has ceased to be detected.
This Shut-off delay can be set when operation is in 3, 6 or 0 Mode by using the “TIME” knob located on the left side of
the panel at the back of the sensor lens (See Fig.2) . To increase the shut-off delay, turn the knob clockwise. To
decrease shut off delay, turn the knob counterclockwise. The delay may be adjusted from a minimum of 5 seconds to
a maximum of 3 minutes. The light will stay on as long as motion is detected continuously and will automatically turn
to low-level brightness when no more motion is detected after the delay time has passed.
Sensitivity of Motion Sensor
The sensitivity of the motion sensor can be adjusted by using the “Sens” knob located on the right side of the panel at
the back of sensor lens (See Fig.2). To increase sensitivity, turn the knob clockwise. To decrease sensitivity, turn the
knob counterclockwise. The sensitivity may be adjusted from a minimum of 5 feet to a maximum of 40 feet.
NOTE:
1. The sensitivity of the motion sensor will increase as the
environmental temperature gets cooler. For best performance,
gently clean the lens with a soft cloth every 1 or 2 months to
assure maximum sensitivity.
2. For best performance, install fixture at least 6 feet above
the ground. At such a height, the fixture will provide a
detection distance of up to 40 feet at 77 degrees
fahrenheit. (See Fig.3)
3. The sensor detects across a detection range of 180 degrees
(See Fig.4)
4. The sensor will be more sensitive to motion across its
detection path than motion directly towards it. (See Fig.5)
5. To reduce possible nuisances, do not mount the fixture
near a heat source like an air conditioner, vent or furnace
exhaust, or in a direction facing any reflecting object or
Manual
Override
Mode
Manual Override Operation Diagram
Turn wall switch OFF-ON
in 3 Seconds
Turn wall switch OFF-ON
in 3 Seconds again
Fig. 1
“3H Mode”
“6H Mode”
“0 Mode”
On the back of the sensor
Time Low Level Sens
Test 3H 6H 0
Fig. 2
4. 0 MODE (nighttime operation only)
● The light will turn to low level brightness (0%~50% brightness) at dusk. The light will turn to high-level brightness
(100% brightness) when motion is detected, and stay on as long as the motion is continuing. When motion is no
longer detected, the light will remain on for the predetermined time you set (5~180 seconds), and then revert to
low level brightness you set.
● Light will turn off automatically at dawn, and return to 0 H mode at dusk.
5. Manual Override MODE (nighttime operation only; on at dusk,off at dawn)
● In 3, 6 or 0 mode, to shift to manual override mode, turn off the wall switch in 3 seconds and then turn it on again,
the light will turn to high-level brightness at dusk, and turn off automatically at dawn. To return to the previous
settings, turn off the wall switch in 3 seconds and then turn it on again. (See Fig.1 Fig.2)
● The lights will turn off automatically at dawn.
5`
6`
10`
40`
Where you install your lantern is important:
Be sure the light is mounted straight on the wall;
otherwise, the detection distance may be limited.
Fig. 3 Fig. 4
180˚
Motion
Least sensitivity Most sensitivity
Sensor
Fig. 5
Motion
---The light does not come on at all:
1. Make sure the wall switch and circuit breaker are on.
2. Make sure the wiring is correct.
3. Make sure the bulb is not burned out.
4. Cover the sensor with your palm to verify that the
ambient light level is not too high.
Troubleshooting
Page 4/4 191205
The following parts are available for re-order if damaged or missing.
Spare Parts List:
5-YEAR LIMITED WARRANTY:
All products are warranted to be free of defects in material and workmanship for five (5) years from date of
purchase. This warranty is limited to the correction of any such defect, or the replacement of any such defective
item(s), provided that: (a) we are properly notified and consent to return of the item(s) in question:(b) the item (s)
is / are returned with proof of purchase date; and (c) it is found upon inspection by us that the item (s) is / are defective
as noted above. This warranty dose not cover labor costs, consequential damages, nor dose it apply to any item(s) that
have been improperly installed, overloaded, altered, or otherwise abused by the customer, its agent(s) or employee(s).
Finishes are specially excluded from the terms of this warranty since they are subject to environmental maintenance
deemed beyond our control. Other than the described obligation, we assume no further liability with respect to the sale
or use of our products.We make no warranty, express or implied, and disclaim any warranty of merchantability or fitness
for a particular purpose.
----In Test Mode, the light stays on full brightness after 5 seconds:
1. If during daytime, make sure the slide switch is at the TEST position.
2. Whether the motion is detected at all time.
---In 3H or 6H Mode, the light is still on full brightness,even though it has been 3 hours or 6 hours
after dusk, respectively:
1. Make sure no motion could be picked up by the sensor.
2. Make sure that mode entry is not in manual override.
---After performing 3H or 6H Mode, the light stays on full brightness after 3 minutes:
1. Make sure there is no movement that could be picked up by the sensor.
2. Adjust the time knob counterclockwise to reduce the delay shut-off time.
----In 3H or 6H Mode, the light turns off completely, instead of low level brightness, after 3 minutes:
1. Make sure the bulb you installed is a medium base bulb or LED dimmable bulb.
2. Make sure the bulb is not burned out.
3. make sure the low level is not at the 0% position.
-- The light blinks:
1. Make sure the light is not mounted near a barbecue, air conditioner or other heat source.
2. Adjust the sensitivity knob counterclockwise to avoid unnecessary triggering like a passing car or
reflecting objects.
3. Make sure the bulb is medium base bulb or Led dimmable bulb.
Assembly Kit
6185MM (1 SET)
Mounting Screw (B) Wire Connector (C)
Bolt Nut (D) Rubber Pad (E)
Cross Bar Unit (A)
Glass Shade
X1
10143CS Set Screw
6188SER
A
B
C
A: 13-1/4”
B: 7-1/2”
C: 9-1/2”

This manual suits for next models

1

Other Vaxcel Outdoor Light manuals

Vaxcel T0692 Instruction manual

Vaxcel

Vaxcel T0692 Instruction manual

Vaxcel T0199 Instruction manual

Vaxcel

Vaxcel T0199 Instruction manual

Vaxcel Chatham Instruction manual

Vaxcel

Vaxcel Chatham Instruction manual

Vaxcel T0414 Instruction manual

Vaxcel

Vaxcel T0414 Instruction manual

Vaxcel T0568 Instruction manual

Vaxcel

Vaxcel T0568 Instruction manual

Vaxcel T0694 Instruction manual

Vaxcel

Vaxcel T0694 Instruction manual

Vaxcel T0451 Instruction manual

Vaxcel

Vaxcel T0451 Instruction manual

Vaxcel T0620 Instruction manual

Vaxcel

Vaxcel T0620 Instruction manual

Vaxcel T0080 Instruction manual

Vaxcel

Vaxcel T0080 Instruction manual

Vaxcel T0461 Instruction manual

Vaxcel

Vaxcel T0461 Instruction manual

Vaxcel T0496 Instruction manual

Vaxcel

Vaxcel T0496 Instruction manual

Vaxcel T0076 Instruction manual

Vaxcel

Vaxcel T0076 Instruction manual

Vaxcel T0698 Instruction manual

Vaxcel

Vaxcel T0698 Instruction manual

Vaxcel T0130 Instruction manual

Vaxcel

Vaxcel T0130 Instruction manual

Vaxcel T0517 Instruction manual

Vaxcel

Vaxcel T0517 Instruction manual

Vaxcel T0624 Instruction manual

Vaxcel

Vaxcel T0624 Instruction manual

Vaxcel T0165 Instruction manual

Vaxcel

Vaxcel T0165 Instruction manual

Vaxcel T0040 Instruction manual

Vaxcel

Vaxcel T0040 Instruction manual

Vaxcel T0717 Instruction manual

Vaxcel

Vaxcel T0717 Instruction manual

Vaxcel T0541 Instruction manual

Vaxcel

Vaxcel T0541 Instruction manual

Vaxcel T0637 Instruction manual

Vaxcel

Vaxcel T0637 Instruction manual

Vaxcel T0258 Instruction manual

Vaxcel

Vaxcel T0258 Instruction manual

Vaxcel T0181 Instruction manual

Vaxcel

Vaxcel T0181 Instruction manual

Vaxcel T0321 Instruction manual

Vaxcel

Vaxcel T0321 Instruction manual

Popular Outdoor Light manuals by other brands

Kichler Lighting LEMMY 37535 instructions

Kichler Lighting

Kichler Lighting LEMMY 37535 instructions

GOLDENSEA UV UVP36 quick start guide

GOLDENSEA UV

GOLDENSEA UV UVP36 quick start guide

Würth 0981 300 000 Translation of the original operating instructions

Würth

Würth 0981 300 000 Translation of the original operating instructions

Patriot Lighting DJ2266 MBLK instructions

Patriot Lighting

Patriot Lighting DJ2266 MBLK instructions

Nightscaping Mailbox Series Installation sheet

Nightscaping

Nightscaping Mailbox Series Installation sheet

LIGMAN VANCOUVER 65 installation manual

LIGMAN

LIGMAN VANCOUVER 65 installation manual

iGuzzini PIXY installation instructions

iGuzzini

iGuzzini PIXY installation instructions

LIGMAN NORDSTROM 1 installation manual

LIGMAN

LIGMAN NORDSTROM 1 installation manual

LUCIDE ZARO manual

LUCIDE

LUCIDE ZARO manual

Style selections 13217 quick start guide

Style selections

Style selections 13217 quick start guide

modway EEI-5627 Assembly instructions

modway

modway EEI-5627 Assembly instructions

Intertec Data Systems 1288438 Assembly instructions

Intertec Data Systems

Intertec Data Systems 1288438 Assembly instructions

Probrite DAWN12-PC-4K-BZ INSTALLATION, USAGE, & CARE GUIDE

Probrite

Probrite DAWN12-PC-4K-BZ INSTALLATION, USAGE, & CARE GUIDE

Dyson Lightcycle CD05 operating manual

Dyson

Dyson Lightcycle CD05 operating manual

Quoizel DRS8411EK installation guide

Quoizel

Quoizel DRS8411EK installation guide

Ashley Harbour ASH32675A installation guide

Ashley Harbour

Ashley Harbour ASH32675A installation guide

Digilin Spear installation guide

Digilin

Digilin Spear installation guide

Trio 4602021-24 quick start guide

Trio

Trio 4602021-24 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.