Positioningthefoundationblocks(16)(optional)
This should be done with great care as there is no leeway with the beams! The distance from the foundation block to the wall
should be size D minus 165 mm. (Speci ed in the list of contents provided). This applies to all the blocks. The foundation
blocks are oen laid into the (paved) patio. The distance between the underside of the paving stone and the top of the foun-
dation block should be at least 100 mm (10 cm). When determining the width, take the gutter and drainpipe into account.
Mountingtheuprights(14)
The uprights supplied are longer than required (200 mm) and should be sawn to size. The size H2 plus the thickness of the
paving stone/oor plus the depth to the foundation block (16) is the total length of the upright.
Another 100 mm (10 cm) should be sawn o the size of the cover plate (17) of the upright (14) so that the drainpipe can be
xed. The base plate (15) should be screwed down with the screws supplied (C).
6
7
3. Foundation blocks and uprights