Installation guidelines
For easier installation, programming and RF testing should be done
before mounting to check for good communication between the
control panel and all system devices. Install the detector and other
system devices in the following order:
>Programming/RF Testing - program detector and all other
devices into the control panel and test RF communication from
each intended device location to the control panel.
>Mounting - Mount detector at the tested location.
The ICT 702 universal door contact is designed
for use with Videofied™ wireless security
systems.
The contact includes the following features :
• Completely wireless and powered by a
Lithium battery
• Dual tamper function provides detection for
both wall and cover tamper
• Transmits check-in/status signal every 8
minutes
• Wired input for wired detectors connection
Product presentation
Programming/RF Testing/Mounting
The following provides summarized steps for device
programming, testing and mounting. For complete details, refer to
the control panel installation manual.
1Loosen the screw, open the box and
insert the batteries.
2 Close the box and tighten the screw.
3Put control panel into configuration
mode.
4Using a programmed keypad, proceed
through menus until the display shows ADD
A NEW DEVICE.
5Press YES/OK. The display shows
PRESS PROGRAM BUTTON OF DEVICE.
6Using a paperclip, press and release the
contact INIT button.
The contact LED flashes. Wait for the
keypad to display DETECTOR (1-24)
RECORDED.
7Press YES/OK. The display shows
RADIO RANGE TEST?
Press YES/OK again. The detector LED
starts flashing and keypad display shows
TEST IN PROGRESS.
8Take the detector to its intended
mounting location and make sure that the
LED flashes continuously, indicating good
communication with the control panel.
9Press YES/OK to end the radio range test then press ESC NO.
10 The display shows AREA ASSIGNMENT AREA: 1. Press either
arrow button repeatedly until desired AREA number appears, then
press YES/OK.
11 The display shows PERIMETER DEVICE?
Press YES/OK or ESC NO, whichever is appropriate for this device
(a device configured as PERIMETER will be armed for the “E” and
perimeter special arming modes, only contacts protecting the
external accesses should be configured for perimeter arming).
12 The display shows NAME + LOCATION:
Enter appropriate device name/location (up to 16 characters), then
press YES/OK. The display shows the device number and name for
confirmation.
13 Press YES/OK. The display shows:
FUNCTIONAL DEVICE TEST?
Caution: the panel records the current state of the detector
and the current state of the wired input as being the normal
state at the beginninfg of the functional device test :
• The door contact must be closed at the beginning of the
detection test to be configured as Normally Closed NC.
• If the wired input is open when recorded, it will be
configured as Normally Open NO(and conversely).
That setting cannot be changed unless the contact is
deleted from the panel programming and recorded again.
Press YES/OK again and verify detector operation. For example,
move the magnet next to the detector to make the LED go off,
then move the magnet away from detector to make LED turn on
indicating detection.
14 Press YES/OK to end detection verification.
15 The display shows ENTERING A NEW DEVICE?
Repeat steps 1 - 14 for remaining detectors.
Screw
INIT button
LED
INSTALLATION SHEET
DOC. - REF. 219-ICT-AUS
MODIF. DATE : MAY 2017
VERSION : XX.XX.XX
1
INDOOR CONTACT TRANSMITTER ICT702
Mounting procedure
> Use proper tools and hardware.
>To prevent false triggering the magnet must be aligned with the
upper part of the contact, following the markings. Use the plastic
adapters to align the magnet.
> The magnet must always be mounted on the mobile part (door).
Note: do not install the contact and its magnet on a ferromagnetic
support
>The distance between the magnet and the contact must be lower
than 1 cm.
>Install that device indoors with a controllled temperature.
Note: if only the wired input is used, installing the magnet is not
needed.
1 Remove the base from the contact.
2Hold the base against the wall and mark
the mounting points.
3Drill.
4 Mount the base on the wall.
5 If using the wired input, connect
2 AWG22 wires from the wired
detector to the input terminals.
6Mount the detector on its base
and lock with the screw.
7 Insert the magnet in its case.
8 Use the plastic parts to place the
magnet next to the detector.
9Hold the magnet base against the wall and mark the mounting
points.
10 Drill.
11 Fix the mounting with the appropriate screws.
Mounting
brackets
Connect to the
wired detector
terminals
2
INSTALLATION SHEET INDOOR CONTACT TRANSMITTER ICT702
Security notes / (FR) Notes de sécurité / (DE) Hinweise zur Sicherheit
Français
• Retirez les piles avant toute opération de
maintenance !
• Attention ! Il y a un risque d'explosion si la batterie
utilisée est remplacée par un mauvais modèle !
• Respectez la polarité lors de la mise en place des
piles !
• Ne jetez pas les batteries usagées !
Ramenez-les à votre installateur ou à un point de
collecte spécialisé.
English
• Remove the batteries before any
maintenance !
• WARNING, there is a risk of explosion if a battery
is replaced by an improper model !
• Observe polarity when setting up the batteries!
• Do not litter the batteries when they are used!
Dispose of them properly according to Lithium
Metal requirements
Deutsch
• Batterien vor jeglichen Wartungsarbeiten
entfernen!
• Vorsicht, es besteht Explosionsgefahr, wenn eine
Batterie durch eine Batterie falschen Models
ersetzt wird!
• Achten Sie beim Einsetzen der Batterien auf die
Polung!
• Entsorgen Sie Batterien nicht im normalen
Haushaltsmüll! Bringen Sie Ihre verbrauchten
Batterien zu den öffentlichen Sammelstellen.
3
www.videofied.com
INSTALLATION SHEET
Battery Type C - CR123A - 1 Lithium battery
Nominal voltage 3 V
Low battery limit 2.8 V
Estimated battery life Up to 4 years
Current consumption
Standby (1h average) 37 μA
Max 35 mA (with alarm and communication)
RF Wiselink® technology
Radio type Spread spectrum RF bidirectional
Operating frequency
• 915/928 MHz - ICT702 (Australia, South America)
Transmission security AES algorithm encryption
Supervision Radio, batteries, tamper
Radio antenna Integrated
RADIO PROPERTIES
Panel compatibility W, X and VISIO panels
ELECTRICAL PROPERTIES BOX
Physical properties
Material ABS UL94-V0
Dimensions 79.3 mm x 35 mm x 24.6 mm
Weight 32 g (without battery)
Shock & water protection markings IP30/IK04
Installation / Mounting
Mounting support Non-ferromagnetic surface (ex : wood)
Wall mounting 2 screws
Box sealing 1 screw
Environmental properties
Operating temperature -10°/+55°C
Max relative humidity 75%, without condensing
Internal detection I.L.S with provided Alnico magnet
Axis of detection X1, X2, Y, Z
Opening detection distance
•X1: 14 mm, 49 mm
•X2: 12 mm, 41 mm
•Y : 24 mm
•Z : 40 mm
Closing detection distance
• X1: 12 mm, 43 mm
•X2: 10 mm, 37 mm
•Y : 20 mm
•Z : 35 mm
Initialization time 10s
Recovery time 2s
External detection Wired input
Max wire length 16m
Input type NC or NO (recorded during detection test)
DETECTION PROPERTIES
Tamper
Tamper detection Cover and wall tamper
STANDARDS AND CERTIFICATIONS
915/928 MHz (ICT 702)
Australia RCM AS/NZS4268
INDOOR CONTACT TRANSMITTER ICT702
V
ideo Alarm Technologies Pty Ltd.
Enquiries: + 61 7 5491 7415 / 1300 46 44 55
[email protected]
www.videoalarmtechnologies.com.au

Other Videofied Security System manuals

Videofied ISMV 200 User manual

Videofied

Videofied ISMV 200 User manual

Videofied XL 3.1 Owner's manual

Videofied

Videofied XL 3.1 Owner's manual

Videofied VISIO User manual

Videofied

Videofied VISIO User manual

Videofied VIA-Pro User manual

Videofied

Videofied VIA-Pro User manual

Videofied XT series User manual

Videofied

Videofied XT series User manual

Videofied SE550 User manual

Videofied

Videofied SE550 User manual

Videofied IDC Series User manual

Videofied

Videofied IDC Series User manual

Videofied SE601 User manual

Videofied

Videofied SE601 User manual

Videofied XT Installation and operating instructions

Videofied

Videofied XT Installation and operating instructions

Videofied XT GPRS User manual

Videofied

Videofied XT GPRS User manual

Videofied XL GPRS User manual

Videofied

Videofied XL GPRS User manual

Videofied CT211 User manual

Videofied

Videofied CT211 User manual

Videofied xl series User manual

Videofied

Videofied xl series User manual

Videofied OSMVC 200 User manual

Videofied

Videofied OSMVC 200 User manual

Videofied XTO Series User manual

Videofied

Videofied XTO Series User manual

Videofied CT 600 User manual

Videofied

Videofied CT 600 User manual

Videofied XV User manual

Videofied

Videofied XV User manual

Videofied W730 User manual

Videofied

Videofied W730 User manual

Videofied SE651 User manual

Videofied

Videofied SE651 User manual

Videofied OMV601 User manual

Videofied

Videofied OMV601 User manual

Popular Security System manuals by other brands

DEXAPLAN CA 606 - 9-2005 manual

DEXAPLAN

DEXAPLAN CA 606 - 9-2005 manual

LockNet DKYSLRH installation instructions

LockNet

LockNet DKYSLRH installation instructions

M2M RControl MQ03SD-RCALARM-RF Installer manual

M2M

M2M RControl MQ03SD-RCALARM-RF Installer manual

NETGEAR Arlo user manual

NETGEAR

NETGEAR Arlo user manual

Risco Rokonet WisDom Installation and programming manual

Risco

Risco Rokonet WisDom Installation and programming manual

Zodiac Tower 2176 TR owner's manual

Zodiac

Zodiac Tower 2176 TR owner's manual

DMP Electronics XR100FC user guide

DMP Electronics

DMP Electronics XR100FC user guide

Visonic POWERMAX - Especificacoes

Visonic

Visonic POWERMAX - Especificacoes

Trust 200SA instruction manual

Trust

Trust 200SA instruction manual

Texecom Premier Elite iProx installation manual

Texecom

Texecom Premier Elite iProx installation manual

X10 Ninja VK74A Quick setup guide

X10

X10 Ninja VK74A Quick setup guide

Bticino 3489GSM manual

Bticino

Bticino 3489GSM manual

SkyLine AAA Plus Am-001 User instructions

SkyLine

SkyLine AAA Plus Am-001 User instructions

Rondish Nexus ILB-21 User instructions

Rondish

Rondish Nexus ILB-21 User instructions

Snap-On BK8000 user manual

Snap-On

Snap-On BK8000 user manual

TRYSIGHT Mercury 10 user guide

TRYSIGHT

TRYSIGHT Mercury 10 user guide

SB SB-SP7200-GSM instruction manual

SB

SB SB-SP7200-GSM instruction manual

SonicWALL SMA 6200 Getting started guide

SonicWALL

SonicWALL SMA 6200 Getting started guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.