XT700i GPRS control panels are wireless battery operated alarm systemsdesigned for residential, small business security applications and
both indoor and outdoor commercial applications. Through the use of the MotionViewer and Videoed products, the XT700i GPRS panel
offers video verication in case of intrusion.
The XT control panel has three programmable inputs. Note that we advise to use a power supply when using the programmable inputs.
The XT control panel can either be used as a STANDALONE or XTENDER (piggyback) to an exisiting alarm panel.
This application note will focus on the conguration and the use of this programmable inputs. You will be able to program your
programmable input(s) by reading the Conguration section. The Use section will get you an idea of the practical use of programmable
inputs.
PROGRAMMABLE INPUT 1, PROGRAMMABLE INPUT 2 and PROGRAMMABLE INPUT 3 are triggered by voltage between 9V
and 15V and an intensity between 1,5mA (@9V) and 3mA (@15V). If a dry contact is used to trigger the programmable inputs, the
REF+output can be used to supply this dry contact. (See Diagram Page 3 - PROGRAMMABLE INPUT 1 is set up as a panic button).
The XT control panel also offers a mapping feature. Mapping option allows the input to generate a video-clip via a MotionViewer
when a programmable input is triggered and/or when an event occurs. (See Mapping Application note) An obvious application for this
feature is HoldUp alarm event video verification.
Please note that programmable inputs can be allocated to events such as:
www.videofied.com.au
INTRUSION Intrusion event. With siren by default.
TAMPER Tamper event. With siren by default.
PANIC BUTTON Panic Button event. With siren by default.
INCORRECT CODE Incorrect code event. With siren by default.
DURESS CODE1 Duress code event. Without siren by default.cto.
DURESS CODE2 Duress code event. With siren by default.
SUPERVISION Supervision defect event. Without siren by default.
RADIO JAMMING Radio jamming event. Without siren by default.
LOW PANEL BATT. Low panel batteries event. Without siren by default.
LOW DEVICE BATT. Low device batteries event. Without siren by default.
AC POWER MISS. AC Power missing event. Without siren by default.
PANEL RESET Panel reset event. Without siren by default.
SYSTEM ARMED System armed event. Without siren by default.
SYSTEM DESARMED System desarmed event. Without siren by default.
PERIODIC TEST Periodic test event. Without siren by default.
ALARM CANCEL Alarm cancel event. Without siren by default.
SMOKE DETECTION Smoke detection event. With siren by default.
PHONELINE MISS. Phoneline missing event. Without siren by default.
TMT REQUEST TMT request event. Without siren by default.
APPLICATION NOTE
PROGRAMMABLE INPUTS
Made by RSI VIDEO TECHNOLOGIES v.E 1.0