5DINPAD
DINPAD
Troubleshooting
Keypad does not respond to key presses
Keypad is not accepting default master code 000
Keypad no longer accepts user code
Keypad accepts user code but no longer releases lock
Relay triggers and does not return back to its previous state
1. Check the correct voltage is present on the input terminals (12/24v ac/dc).
1. Perform master code reset.
1. Check master code has been changed from the default.
2. Check back EMF protection across lock release.
1. Check the correct relay output is assigned to user code.
2. Check push to exit button is normally open.
3. Check for continuity across relay contacts when user code is entered.
4. Check lock wiring for continuity.
5. Check the correct voltage is present on the input terminals (12/24v ac/dc).
1. Check relay is not set up to latch