VIEWEG DC 200 User manual

VIEWEG
Dosier- und Mischtechnik
1
LIQUID DISPENSER DC 200 series
USER MANUAL
Made in Germany
V2.0EN OCT 2014
© Vieweg GmbH

2
VIEWEG
USER MANUAL LIQUID DISPENSER DC200 series
1. TABLE OF CONTENTS
1. Table of contents. . . . . . . . . . . . . . . . . . . . . . . 02
2. Designated use . . . . . . . . . . . . . . . . . . . . . . . 03
3. For your safety . . . . . . . . . . . . . . . . . . . . . . . 03
4. Technical data . . . . . . . . . . . . . . . . . . . . . . . 04
4.1 parts & description . . . . . . . . . . . . . . . . . . . . 05
5. Parts of Delivery . . . . . . . . . . . . . . . . . . . . . . 06
6. Start and operation . . . . . . . . . . . . . . . . . . . . . 07
7. Electrical connections . . . . . . . . . . . . . . . . . . . . . 10
7.1 Foot switch . . . . . . . . . . . . . . . . . . . . . . . 10
8. Maintenance and cleaning . . . . . . . . . . . . . . . . . . . 10
9. Disposal . . . . . . . . . . . . . . . . . . . . . . . . . 10
10. Declaration of conformity . . . . . . . . . . . . . . . . . . . 11

3
VIEWEG
USER MANUAL LIQUID DISPENSER DC200 series
2. DESIGNATED USE:
The DC200 Liquid dispenser series can be delivered with different options, which can
have a little technical difference. Because of this, in the following user manual is only
spoken about the DC200 controller.
The liquid dispenser DC200 is used for precise controlling of pneumatic controlled dis-
pensing, for example dispensing out of 3 – 55cc cartridges.
With the integrated air pressure regulator, the air pressure on the material can be set
very exactly.
3. FOR YOUR SAFETY:
WARNING:
If the DC200 is used for other functions as in this manual described, it could come
•
to personal or material damage. Use the DC200 controller only to the functions,
which are explained in this user manual. VIEWEG GmbH is not responsible for per-
sonal or material damages, which happen because of incorrect using and no desig-
nated use.
No designated uses are:
•
Modifications at the DC200, which are not recommended in this user manual.
•
Using of defective or not compatible spare parts.
•
Using of not allowed accessoires.
•
SAFETY PRECAUTIONS:
The DC200 works with 100 – 240V AC voltage. By touching the 100 – 240V AC
•
voltage, there exists danger of life !! Because of this, the DC200 must be discon-
nected from the AC input cable, before opening the housing. It is only allowed for
authorized electrical experts to open the housing.
Use the DC200 only with the max. described and allowed power / settings.
•
Always wear useful protection clothing.
•
More details for using the dispensing material, please see the safety data sheets
•
of the dispensing material.
No smoking or fire by using flammable material.
•
The DC200 is only allowed for using inhouse.
•

4
VIEWEG
USER MANUAL LIQUID DISPENSER DC200 series
4. TECHNICAL DATA
Measurements 235 x 225 x 75mm
Weight ca. 1,25 kg
Power supply: 85 – 264V AC 50/60Hz
Internal voltage 24V DC
Air inlet 0 ... 7 bar
Air outlet Cartridge = working pressure
DC215: 0 ... 1 bar (pressure regulator)
DC270: 0 ... 7 bar (pressure regulator)
Dispense time
DIP Switch settings:
bottom of housing
0,01 - 31 seconds
#1 ON = 0,02 - 20,0 sec
#2 ON = 0,1 - 10,0 sec
#3 ON = 0,01 - 1,0 sec
#1,2,3 ON = 0,3 - 31,0 sec
#1,2,3 OFF = 0,05 - 0,4 sec
#4 Initiate Mode
ON = maintained
OFF = momentary
Model types DC215: 0 ... 1 bar (pressure regulator)
DC270: 0 ... 7 bar (pressure regulator)

5
VIEWEG
USER MANUAL LIQUID DISPENSER DC200 series
4.1 PARTS & DESCRIPTION
[Front side]
[Back Side]
Connector for foot
switch
Power switch Air outlet for vacuum
suck back
Fuse 2A TPower inletAir inlet 0 - 7 bar
Pressure gage for
air outlet
Pressure regulator:
0 – 7 bar
Setting vacuum
suck back
Air outlet
Power LED
Timer
ON/OFF
Adjustable
Dispense time

6
VIEWEG
USER MANUAL LIQUID DISPENSER DC200 series
5. Parts of Delivery:
• DC200 Liquid Dispenser
• PowerInletCable
• TubeforAirInlet
• UserManual
• Cartridgeholder
• Accessories(seefollowinglist)
• Tipassortment-small
Qty. Description Part.-no. Reorder
Qty. per pkg.
1* Power cable – 230V C-0043 1
1* Cartridge holder C-0041 1
1* Air inlet tube C-0042 1
1* Foot switch with cable C-0040 1
1* Cartridge adapter 30cc 560004A 1
1* Cartridge adapter 5cc 560003A 1
3* Cartridge 30cc 560002E 10
3* Cartridge 5cc 560001A 10
3* Piston PE 30cc 560552 10
3* Piston PE 5cc 560550 10
1* Tip assortment small 990062-K 1
* Included in delivery

7
VIEWEG
USER MANUAL LIQUID DISPENSER DC200 series
6. Start & Operation
• ConnectthepowerinletcabletothePowerinletconnectoronthebackside.
• ConnecttheAirInlettubefromthecompressortotheAirInletatthebacksideof
the DC200.
• ConnecttheFootswitch(opt.:–C-0040)orthedispensecableofthedispense
robot to the foot switch connector in the backside of the DC200.
• SwitchONtheliquiddispenser.ThegreenPOWER-LEDlights.Thedeviceisnow
ready for work.
• Connectthecartridgetotheadapterlikefollowingdiagram:
• Connecttheairtubeofthecartridgeadaptertotheairpressureoutputofthe
DC200 and adjust the pressure fur the cartridge on the front side with the pres-
sure controller.
• AdjusttheVacuumtoreducematerialdripping.

8
VIEWEG
USER MANUAL LIQUID DISPENSER DC200 series
• SelectMODEontheswitchonthefrontside:
Timer OFF: The DC200 dispenses as long as the foot switch is applied.
Timer ON: The DC200 dispenses as long as the timer is adjusted.
A short apply on the foot switch is enough.
• SettingthedispensetimeinTimermode:
With the potentiometer on the front plate (Scale 0 – 10), the dispensing time can
be adjusted. 4 timing ranges are available, which can be selected with the DIP-
switch at the bottom of the controller housing:
4 time ranges:
#1 ON = 0,02 - 20,0 sec
#2 ON = 0,1 - 10,0 sec
#3 ON = 0,01 - 1,0 sec
#1,2,3 ON = 0,3 - 31,0 sec
#1,2,3 OFF = 0,05 - 0,4 sec
#4 Initiate Mode
ON = maintained
OFF = momentary

9
VIEWEG
USER MANUAL LIQUID DISPENSER DC200 series
Connections
After you have done all connections, it should look like follows:
DC200 Serie
COMPRESSED AIR
70-100 PSI

10
VIEWEG
USER MANUAL LIQUID DISPENSER DC200 series
7. Electrical Connections
7.1 Foot switch:
pins: connection between Pin 1 + 3 starts dispensing
Foot switch:
The Foot switch input gets activated if the input is set to GND. It is NOT Allowed to
input a Voltage. This may damage the control input !
8. Maintenance and cleaning
The DC200 is maintenance free
Repairs should only be done by the manufacturer.
Clean the DC200 liquid dispenser only with a clean, smooth and dry cloth.
Do not use dissolver material to clean the DC200 controller. The foil at the front- or
back plate or the housing paintings can be destroyed.
9. Disposal
Dispose the product after the economic life-time according to the legal
requirements.

11
VIEWEG
USER MANUAL LIQUID DISPENSER DC200 series
10. Declaration of conformity:
Dosier- und Mischtechnik
CE Konformitätserklärung
CE KonformitätserklärungCE Konformitätserklärung
CE Konformitätserklärung
• EG
EGEG
EG-
- --Niederspannungsrichtlinie 2006/95/EG
Niederspannungsrichtlinie 2006/95/EGNiederspannungsrichtlinie 2006/95/EG
Niederspannungsrichtlinie 2006/95/EG
• EG
EGEG
EG-
- --Richtlinie Elektromagnetische Verträglichkeit 89/336/EWG
Richtlinie Elektromagnetische Verträglichkeit 89/336/EWG Richtlinie Elektromagnetische Verträglichkeit 89/336/EWG
Richtlinie Elektromagnetische Verträglichkeit 89/336/EWG
und 2004/108/EG
und 2004/108/EGund 2004/108/EG
und 2004/108/EG
Hiermit erklären wir, dass das folgend genannte Produkt den Bestimmungen
der oben gekennzeichneten Richtlinien und aufgrund seiner Konzipierung und
Bauart, sowie in der von uns in Verkehr gebrachten Ausführung den
einschlägigen Bestimmungen entspricht.
Produkt:
Dosiergerät
DosiergerätDosiergerät
Dosiergerät
Typ:
DC
DC DC
DC 200
200200
200 Serie
Serie Serie
Serie
Hersteller: VIEWEG Do
VIEWEG DoVIEWEG Do
VIEWEG Dosier
siersier
sier-
- -- und Mischtechnik
und Mischtechnik und Mischtechnik
und Mischtechnik
Gewerbepark 13
85402 Kranzberg
Tel.: 08166-6784-0
Fax: 08166-6784-20
Folgende harmonisierte europäische Normen wurden angewandt:
Folgende harmonisierte europäische Normen wurden angewandt:Folgende harmonisierte europäische Normen wurden angewandt:
Folgende harmonisierte europäische Normen wurden angewandt:
• DIN EN ISO 61000-6-3 Störaussendungen
• DIN EN ISO 61000-6-2 Störfestigkeit
Kranzberg,
07.07.2011
Till Vieweg, Geschäftsführer