Item # __________________________
C.S.I. Section 11420
VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201, TEL. 1-800-814-2028
502-778-2791 QUOTE & ORDER FAX: 1-800-444-0602
A2780
ISO9001
Vulcan-Hart Co.
F-31648 (10-03)
SPECIFICATIONS:
Electric, self-contained, stainless steel, 2/3jacketed floor
mounted steam kettle, Vulcan-Hart Model No. ___________.
Fully welded hemispheric bottom kettle with type 304 stainless
steel jacket and lining (316 stainless steel liner, 20, 30 & 40
gallon). Jacket tested to 50 psi (3.4 kg/cm2). Jacket contains
water, rust inhibitor and antifreeze mixed to protect to 30°
below zero. Counterbalanced hinged stainless steel cover
with drop down lift handle (60 - 100 gallon spring assist). 2"
compression tangent draw-off valve with perforated strainer.
Tubular stainless steel legs with flanged feet. Controls enclosed
in stainless steel housing include a power switch, thermostat,
power "on" light, vacuum/pressure gauge, pressure relief valve
and low water signal light. Elements are field replaceable.
Requires 208 or 240 volts, 60 Hz, 3 phase.
U L listed. NSF listed. Meets ASME code.
VEL SERIES
ELECTRIC FLOOR MOUNTED
STATIONARY 2/3JACKETED KETTLE
MODELS: VEL SERIES Electric Floor Mounted Stationary 2/3Jacketed Kettle
■■VEL20 12 KW, 20 gallon capacity
■■VEL30 15 KW, 30 gallon capacity
■■VEL40 18 KW, 40 gallon capacity
■■VEL60 18 KW, 60 gallon capacity
■■VEL80 18 KW, 80 gallon capacity
■■VEL100 24 KW, 100 gallon capacity
STANDARD FEATURES
■Electric, self-contained stainless steel, 2/3jacketed floor
mounted steam kettle.
■Fully welded hemispheric bottom kettle with type 304 stainless
steel jacket and lining. (316 stainless steel liner for 20, 30 & 40
gallon models.)
■Jacket tested to 50 psi (3.4 kg/cm2).
■Jacket contains water, rust inhibitor and antifreeze mixed to
protect to 30° below zero.
■One piece counterbalanced hinged stainless steel cover with
drop down lift handle (60 - 100 gallon spring assist).
■2" compression tangent draw-off valve with perforated strainer.
■Faucet bracket.
■Tubular stainless steel legs with flanged feet.
■Controls enclosed in stainless steel housing include a power
switch, thermostat, power "on" light, vacuum/pressure gauge,
pressure relief valve and low water signal light.
■Elements are field replaceable.
■Requires 208 or 240 volts, 60 Hz, 3 phase.
■One year limited parts and labor warranty.
OPTIONS
■■Spring assist cover (20 - 40 gallon).
■■Two-piece hinged cover.
■■3" compression draw-off valve with perforated strainer.
■■Correction facility package:
a. Security type tamper resistant fasteners with tack welds.
b. Stainless steel step cover over draw-off valve with chain.
c. Type 316 liner (60 - 100 gallon).
■■Pedestal base.
■■Single phase, 12 or 15 KW.
■■24 KW elements (40, 60 & 80 gallon models only).
■■33 KW (60, 80 & 100 gallon models only).
■■480 volts, 60 Hz, 3 phase.
■■Second year extended limited parts and labor warranty.
ACCESSORIES
■■Contour measuring strip.
■■Perforated stainless steel basket assembly (single - 20 gal.)
(triple - 20 through 100 gallon).
■■Clean-up kit, includes draw-off brush, clean -up brush and
paddle scraper with 40" handle.
■■Stainless steel 48" whip.
■■Solid disk.
■■(12") (18" double jointed) single pantry faucet.
■■(12") (18" double jointed) double pantry faucet.
■■Double pantry washdown hose with 16" add-on faucet with
backflow preventer.
■■Double pantry washdown hose with backflow preventer.
■■Double pantry pot filler and backflow preventer.
Printed On Recycled Paper
VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201, TEL. 1-800-814-2028
502-778-2791 QUOTE & ORDER FAX: 1-800-444-0602
NOTE: In line with its policy to continually improve its products, Vulcan-Hart Company reserves the right to change materials and
specifications without notice.
F-31648 (10-03)
VEL SERIES
ELECTRIC FLOOR MOUNTED
STATIONARY 2/3JACKETED KETTLE
SERVICE CONNECTIONS:
Electric Connection: To be as specified on data plate.
BRIMFUL CAPACITIES (in 4 oz. servings):
Working capacity 70% to 80% of brimful depending on model.
80 quarts/20 gallons/76 liters/640 servings
100 quarts/30 gallons/95 liters/800 servings
120 quarts/40 gallons/152 liters/1,280 servings
160 quarts/60 gallons/227 liters/1,920 servings
240 quarts/80 gallons/303 liters/2,560 servings
400 quarts/100 gallons/379 liters/3,200 servings
MODEL CAPACITY A B C D E F(2") F(3") G(2") G(3") H J K L
VEL20 20 gallons 21 18 38 23.75 18.5 14.75 15.5 18 17.5 14 21 60.5 16.75
76 liters 533 457 965 629 470 375 394 457 445 356 533 1537 425
VEL30 30 gallons 24 20 38 27.75 20 16 16.5 15.75 15.25 12.5 19 63.5 18.312
114 liters 610 508 965 705 508 406 419 400 387 318 483 1613 465
VEL40 40 gallons 26 22.5 38 29.75 21 17 18 13.5 13 9 17 65 19.938
152 liters 660 572 965 756 533 432 457 343 330 229 432 1651 506
VEL60 60 gallons 29.5 26 42 33.75 19 18 19.25 14 13.5 11 17.25 75 23.125
227 liters 749 660 1067 857 483 457 489 356 343 280 438 1905 587
VEL80 80 gallons 33 28 45 36.75 20.5 19.5 20.5 15 14.5 12.75 18 81 26.25
303 liters 838 711 1143 933 521 495 521 381 368 324 458 2058 667
VEL100 100 gallons 35.5 30 48 40 22 21.5 22.5 15 14.5 13 20.5 87 29.438
379 liters 902 762 1219 1016 559 546 572 381 368 330 521 2210 748
208V 230V 240V 380V 415V 480V
MODEL KW AMP KW AMP KW AMP KW AMP KW AMP KW AMP
VEL20 12 33.4 12 30.1 12 28.9 12 18.3 12 16.7 12 14.5
VEL30 15 41.7 15 37.7 15 36.1 15 22.8 15 20.8 15 18
VEL40 18 50 18 45.2 18 43.4 18 27.4 18 25 18 21.7
VEL60 18 50 18 45.2 18 43.4 18 27.4 18 25 18 21.7
VEL80 18 50 18 45.2 18 43.4 18 27.4 18 25 18 21.7
VEL100 24 66.6 24 60.2 24 57.7 24 36.5 24 33.3 24 28.9
ELECTRICAL CHARACTERISTICS
NOTE:
• Dimensions which locate the above connections have a tolerance of +
or -3" (+ or -75 mm).
• Installation of backflow preventers, vacuum breakers and other spe-
cific code requirements is the responsibility of the owner and installer.
It is the responsibility of the owner and installer to comply with local
codes.
• Plastic drains are not recommended due to inherent limited tempera-
tures of the plastic. Boiler purge temperatures may exceed 180°F. The
installer may be required to provide means to reduce boiler purge water
temperature to be that of the condensate temperature of 140°F or less.
• This appliance is manufactured for commercial installation only and is
not intended for home use.

Other manuals for VEL100

2

This manual suits for next models

5

Other Vulcan-Hart Kettle manuals

Vulcan-Hart K20DL ML-136081 User manual

Vulcan-Hart

Vulcan-Hart K20DL ML-136081 User manual

Vulcan-Hart GL40E User manual

Vulcan-Hart

Vulcan-Hart GL40E User manual

Vulcan-Hart K6ETT User manual

Vulcan-Hart

Vulcan-Hart K6ETT User manual

Vulcan-Hart VEL100 Service manual

Vulcan-Hart

Vulcan-Hart VEL100 Service manual

Vulcan-Hart K40GL User manual

Vulcan-Hart

Vulcan-Hart K40GL User manual

Vulcan-Hart VEL100 Instruction Manual

Vulcan-Hart

Vulcan-Hart VEL100 Instruction Manual

Vulcan-Hart VELT40 Guide

Vulcan-Hart

Vulcan-Hart VELT40 Guide

Vulcan-Hart K12ETT ML-136068 User manual

Vulcan-Hart

Vulcan-Hart K12ETT ML-136068 User manual

Vulcan-Hart VELT100 Instruction Manual

Vulcan-Hart

Vulcan-Hart VELT100 Instruction Manual

Vulcan-Hart VELT20 Guide

Vulcan-Hart

Vulcan-Hart VELT20 Guide

Vulcan-Hart VDLT Series Guide

Vulcan-Hart

Vulcan-Hart VDLT Series Guide

Vulcan-Hart ML-103414 Instruction Manual

Vulcan-Hart

Vulcan-Hart ML-103414 Instruction Manual

Vulcan-Hart K20EL User manual

Vulcan-Hart

Vulcan-Hart K20EL User manual

Vulcan-Hart K6ETT User manual

Vulcan-Hart

Vulcan-Hart K6ETT User manual

Vulcan-Hart 1T4024E User manual

Vulcan-Hart

Vulcan-Hart 1T4024E User manual

Vulcan-Hart VEC20 User manual

Vulcan-Hart

Vulcan-Hart VEC20 User manual

Vulcan-Hart VEC10 Guide

Vulcan-Hart

Vulcan-Hart VEC10 Guide

Vulcan-Hart VSX42GT User manual

Vulcan-Hart

Vulcan-Hart VSX42GT User manual

Vulcan-Hart VGL20 User manual

Vulcan-Hart

Vulcan-Hart VGL20 User manual

Vulcan-Hart VDL100 Instruction Manual

Vulcan-Hart

Vulcan-Hart VDL100 Instruction Manual

Vulcan-Hart VDL100 User manual

Vulcan-Hart

Vulcan-Hart VDL100 User manual

Vulcan-Hart 1T2018D User manual

Vulcan-Hart

Vulcan-Hart 1T2018D User manual

Vulcan-Hart 1T4024G User manual

Vulcan-Hart

Vulcan-Hart 1T4024G User manual

Vulcan-Hart SS Series User manual

Vulcan-Hart

Vulcan-Hart SS Series User manual

Popular Kettle manuals by other brands

Proficook PC-WKS 1119 instruction manual

Proficook

Proficook PC-WKS 1119 instruction manual

TriStar WK-3213 user manual

TriStar

TriStar WK-3213 user manual

BRAYER BR1075 instruction manual

BRAYER

BRAYER BR1075 instruction manual

Melissa 645-103 user guide

Melissa

Melissa 645-103 user guide

Kalorik JK 42458 operating instructions

Kalorik

Kalorik JK 42458 operating instructions

OXO BREW instruction manual

OXO

OXO BREW instruction manual

CASO DESIGN Selection WK 2200 Original operating manual

CASO DESIGN

CASO DESIGN Selection WK 2200 Original operating manual

KoolMore SK-BK-3G user manual

KoolMore

KoolMore SK-BK-3G user manual

Sapir Z-1230-GB instruction manual

Sapir

Sapir Z-1230-GB instruction manual

Kenwood SJ480 series user guide

Kenwood

Kenwood SJ480 series user guide

INNOLIVING INN-726 user manual

INNOLIVING

INNOLIVING INN-726 user manual

PLINT PURE KETTLE Instructions for use

PLINT

PLINT PURE KETTLE Instructions for use

Groen TD/3 Operator's manual

Groen

Groen TD/3 Operator's manual

Bodum BISTRO 11452 instruction manual

Bodum

Bodum BISTRO 11452 instruction manual

GE 106810 owner's manual

GE

GE 106810 owner's manual

Kenwood JK340 series user guide

Kenwood

Kenwood JK340 series user guide

Scarlett SC-EK18P16 instruction manual

Scarlett

Scarlett SC-EK18P16 instruction manual

UFESA HA Classic instruction manual

UFESA

UFESA HA Classic instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.