WAGO-I/O-SYSTEM 750 Device Description 13
750-506 2DO 24V DC 0.5A/ diagnostics
Manual
Version 1.2.0
Pos: 19 /A lle Ser ien (Al lge meine Mo dule)/ Über schrif ten für all e Serie n/Gerä teb eschrei bung /Gerä tebes chrei bung - Üb er sc hr ift 1 @ 3\mod_1233756084656_21.docx@ 27096@ 1 @ 1
3 Device Description
Pos:20.1/Serie750(WAGO-I/O-S YST EM) /Ger äte b esc hrei bu ng/E i nlei tu ng/A n wen dung /D O/A n wen dung 750-x5 xx D O @ 3\mod_1233764594468_21.docx@ 27120@ @ 1
The 750-506 (2DO 24V DC 0.5A/ diagnostics) Digital Output Module transmits
binary control signals from the automation device to the connected actuators (e.g.,
solenoid valves, contactors, transmitters, relays or other electrical loads).
Pos:20.2/Serie750(WAGO-I/O-S YST EM) /Ger äte b esc hrei bu ng/E i nlei tu ng/A n wen dung /D O/Ü ber la st, Kurz sc hlus s u nd D ra htbr u ch werde n k anal w eise von der K l em me er k ann t. @ 5\mod_1246609628890_21.docx @ 36550@ @ 1
These output modules can recognize a short circuit to ground, a line break and an
overload in either channel.
Pos:20.3/Serie750(WAGO-I/O-S YST EM) /Ger äte b esc hrei bu ng/E i nlei tu ng/I /O-B es c hrei bu ng /DO / I/ O-B esc hrei bu ng 750-0 5xx 2 D O 3-L eit er (DO, 0 V und Er de) @ 5\mod_1246609920281_21.docx @ 36553@ @ 1
The module has two output channels. Two actuators with ground (earth) wire
may be directly connected to signal output DO 1.0 V and PE (earth potential)
or signal output DO 2.0 V and PE.
Pos:20.4/Serie750(WAGO-I/O-SYST EM) / Ger ät eb esc hrei bu ng /Ei nlei tu ng/ I/O -Bes c hr ei bu ng / Al lg em ei n/ V er wei s auf K a pi tel "A nsc hl üss e" @ 8\mod_1276775378035_21.docx@ 57956@ @ 1
The assignment of the connections is described in the “Connectors” section.
Pos:20.5/Serie750(WAGO-I/O-SYST EM) / Ger ät eb esc hrei bu ng /Ei nlei tu ng/ I/O -Bes c hr ei bu ng / Al lg em ei n/ V er wei s auf K a pi tel "G erät e ansc hli eß en" > "A ns c hl us sb ei s pi el( e) " @ 5\mod_1246015203281_21.docx @ 36298 @ @ 1
Connection examples are shown in section “Connecting Devices” > … >
“Connection Example(s)”.
Pos:20.6/Serie750(WAGO-I/O-S YST EM )/ Wi c hti g e Er lä ut er u ng en/ Si ch er h eits - und sonstigeHinweise/AchtungAchtung:DOI nduktionsspannungsbegrenzungElektronik @ 3\mod_1233815757507_21.docx@ 27153@ @ 1
Limit all induced voltage!
The electronic components of the I/O module can be damaged by the induced
voltage produced when inductive loads are de-activated.
An appropriate protection circuit, e.g., a recovery diode, must be installed in
parallel to the load to limit this induced voltage.
Pos:20.7/Serie750(WAGO-I/O-S YST EM) /Ger äte b esc hrei bu ng/E i nlei tu ng/I /O-B es c hrei bu ng /DO / I/ O-B esc hrei bu ng 750-0 5xxD O kurzschlussfest @ 3\mod_1233817429086_21.docx@ 27167@ @ 1
The output channels are electrically short-circuit-protected.
Pos:20.8/Serie750(WAGO-I/O-S YST EM) /Ger äte b esc hrei bu ng/E i nlei tu ng/I /O-B es c hrei bu ng /DO / I/ O-B esc hrei bu ng 750-x5x x D O H SS / pos i ti vschal t end (24 V ) @ 3\mod_1233816955742_21.docx@ 27160@ @ 1
The I/O module outputs provide high-side switching. If the signal status of an
output channel is at “high” the 24 V potential for field power will be switched to
the appropriate output connection.
Pos: 20 .9 /Ser ie 750(WAGO-I/O-SYST EM )/ Ger äte bes chr ei bung /Ei nl ei tung /I/ O-B esc hr ei bu ng /D O /I/ O-B es c hr ei bu ng 75 0-05xxLeistungskontaktdurchEinspeiseklemme@ 5\mod_1246856959993_21.docx@ 36590@ @ 1
The supply voltage for the field side is derived from an adjacent supply module by
means of power jumper contacts.
Pos: 20.1 0 / S er ie 750 ( W AG O-I/ O-SYST EM )/ Wichti g e Erl äuter ung en /Sic her hei ts- un d s o nsti ge Hin wei se /Ac ht u ngAc ht ung : D O Ü b erl asts c hutz - Ei np eis e klem m e mit Sic her u ng @ 3\mod_1233814881117_21.docx@ 27150@ @ 1
Provide for overload protection!
Overloading can damage the electronic components of the I/O module.
A fused supply module (750-601) must be installed upstream of the I/O module to
protect it against overloading!
Pos: 20.1 1 / S er ie 750 ( W AG O-I/ O-SYST EM) /G er ät e be schr eib u ng /Ei nlei t ung / L ED-A nz eig eL ED Z ust a nd Sign al Fehl er Kurz sc hl u ss /D r ah tbr uch /Ü b er las t @ 5\mod_1246873201797_21.docx@36 664 @ @ 1
The status of the two output channels is indicated via green status LEDs. A color
change to red signals an open circuit, overload or a short circuit.
Pos: 20.1 2 / S er ie 750 ( W AG O-I/ O-SYST EM) /G er ät e be schr eib u ng /Ei nlei t ung / L ED-A nz eig e/V er weis auf Kapi tel "A nzei g eel e me nt e" @ 5\mod_1246010525000_21.docx @ 36194@ @ 1
The meaning of the LEDs is described in the “Display Elements” section.
Pos: 20.1 3 / S er ie 750 ( W AG O-I/ O-SYST EM) /G er ät e be sc hr ei b u ng /Ei nlei t ung / V er sor g u ng/ V ers org ung 24 V , 0 V über Leist u ng s ko nt akt e Stan dar d @ 3\mod_1226498974531_21.docx@ 25020@ @ 1
The I/O module 750-506 (2DO 24V DC 0.5A/ diagnostics) receives the 24 V
voltage supply for the field level from an upstream I/O module or from the
fieldbus coupler/controller via blade-formed power jumper contacts. It then
provides these potentials to subsequent I/O modules via spring-formed power
jumper contacts.