WL100ManualPage45Revision:1‐14‐2019
INSTALLATIONPROCEDURES
SafetyandInstallationGuidelines
EnsureallLocal,State,andFederalLawsandCodesincludinghealthandsafetyguidelinesaremet
wheninstallingWaterlogicEquipment.Onlyqualifiedservicetechniciansshouldattempt
installationandserviceofWaterlogicEquipment.
DANGER!ELECTRICALSHOCKHAZARD.Alwaysuseadedicatedandproperlygroundedoutlet.
Unitshouldbeprotectedbyground‐faultcircuitinterrupter(GFCI)orresidualcurrentdevice(RCD)
havingaratedresidualoperatingcurrentnotexceeding30mA.UseonlyWaterlogicsupplied
powercord.Neveruseextensioncordsorpowerstripstoconnectunit.Donotuseifthepower
supplycordisdamaged.Alwaysunplugfrompowersupplypriortoservicing.
CAUTION!INDOORUSEONLY.Neverexposetodirectsunlight,heatsources,orambientair
temperatureabove37°C(100°F)orbelow2°C(35°F).Installindoorsandkeepunitawayfrom
excessivehumidity.Neverexposetofreezingtemperatures.Ensurethereisadequateclearance
aroundtheunittoallowrefrigerationsystemcondensertodissipateheat.Warmerenvironments
requiremoreclearancearoundtheunit.Minimumclearancearoundallsurfacesofthemachineis
2‐inches.Installswheretheambienttemperatureexceeds27°C(80°F),requireaminimumof4‐
inchesclearanceforproperheatdissipationandefficientoperation.
CAUTION!USEAWATERPRESSUREREGULATOR.Waterlogicwillnotberesponsibleforinjuryor
damagecausedbyexcessivewaterpressure.Operatingpressuremustbe40psito60psi.Be
awareanyofpotentialpressuresurgescausedbybuilding/municipalpumpingstations.
CAUTION!USEUVSTABILIZEDSUPPLYLINES.Feedtheunitwithapotableambientorcold
watersupplyonly.Feedwaterover37°C(100°F)candamagethetreatmentcomponents.Water
blockdevicesandexternalleakdetectorsarestronglyrecommended.Locatetheunitascloseto
thewatersupplyandtheelectricalconnectionsaspossible.Locatetheunitasclosetothewater
supplyandtheelectricalconnectionsaspossible.Immediatelyisolateorclosewatersupplyvalve
andcontactservicerepresentativeifleakisnoticed.
WARNING!STOREANDTRANSPORTUNITEMPTY.ALWAYSSANITIZEBEFOREUSE.
Theunitmustbecompletelydrainedandsealedbeforestoringtoavoidstagnationandreduce
microbiologicalcontamination(potentialbacterialgrowth).Sanitizebeforeusetoeliminateany
potentialmicrobiologicalcontaminates
Pre‐installationandsanitizationproceduresasprescribedinthismanualmustbeperformedbefore
installingtheWL100WaterTreatmentSystem.
AlwaysinstallindoorsandplacetheWaterlogicWL100WaterTreatmentSystemonafirm,flatand
stablesurface.
1. Attachthewatersupplylinetothe1/4”feedwaterInletBulkheadFittingonthebackoftheunit.
Waterlogicrequirestheuseofawaterpressureregulator.Waterfeedpressuremustbe
between40‐60psi.Turnonthewatersupplyandcheckforleaks.