WARNING Fire and explosion hazard!
The unit is not permitted to be used for
theextractionofinammablegases.
Theunitmustnotbeexposedtotemperaturesabove
50°C,nakedameorcondensedsolvents.
The organisation operating the unit is responsible for the
observanceofthelegallimitsfornoxioussubstancesat
the place of work.
Theltrationsystemmayonlybeputintooperationifitis
in perfect working order.
Intended use of the soldering station/ desoldering
stationalsoincludestherequirementthatyou
adheretotheseinstructions,
observeallotheraccompanyingdocuments,
complywithnationalaccidentpreventionguidelines
applicable at the place of use.
The manufacturer will not be liable for unauthorised
modicationstothedevice.
User groups
Duetodifferingdegreesofriskandpotentialhazards,sever-
alworkstepsmayonlybeperformedbytrainedexperts.
Work step User groups
Installationofcomplex
pipesystemswith
multipleextractorarms
connected
Specialist personnel with
technical training
Technical trainees under the
guidance and supervision of
atrainedexpert
Replacing electrical repla-
cement parts Electricians
Technical trainees under the
guidance and supervision of
atrainedexpert
Specicationofmainte-
nance intervals Safetyexpert
Operation
Filter change
Non-specialists
Operation
Notice
Theunitmayemitdustfromthemainlteraftertrans-
portation. Make sure that the unit is put into service in
a suitable room.
CAUTION Ahighnoxiousgasconcentrationwill
cause the activated charcoal to heat
up.Toavoidoverheating,theunitshouldberunwithout
noxiousgasesforseveralminutesbeforeswitchingoff.
Put the tool into operation as described in the chapter
„Placingintooperation“.
Please adhere to the operating instructions of the
connected devices.
Checktoseeifthemainsvoltagematchestheratings
on the nameplate.
GB ENGLISH
Make sure the machine is switched off before plugging
in.
Optimalgasltrationisachievedasfollows:
Temperatureofprocessairingaslter<38°C
Relativehumidity<60%
Gasmolecules>30g/mol(betterltrationresultsare
achieved with larger molecules)
Boilingpointofthegasmolecules>0°C
Care and maintenance
WARNING
Before doing any work on the ma-
chine, pull the plug out of the socket.
Theunitmustnotbealteredormodiedinanyway!
Repairs must always be referred to a Weller-trained
specialist.
Useoriginalreplacementpartsonly.
Filter change
year
MIN 1x The normal service life of a main
lterintheelectronicsindustryis
1500 hours.
Themainltershouldbechanged
atleastonceayearinorderto
ensure proper gas separation.
An alarm sounds and the red warning light ashes:
Recommendedservicelifeoflterhasexpired.
Indicatesthatthelterneedschanging.Resetthe
alarm with the reset function on the control panel and
schedulealterchange.
An alarm sounds and the red warning light is lit
continuously:
Extractioncapacityistoolow.
Switchoffthelterunit.Checkthenozzlesandtubes,
andcleanthemifnecessary.Ifthealarmsoundsagain
thenexttimetheunitisturnedon,theltermustbe
changed.
Ifnoactionistaken,thelterunitwillcutoutafterve
minutes in order to avoid overheating.
Whenchangingthemainltertheltrationtimecanbe
reset as follows:
Keeptheresetbuttonpressedand,atthesametime,
turn on the switch until a signal sounds.
Cleaning
Toensurethattheunitfunctionsproperly,thenozzle,
extractorarmandconnectinghosemustbecleaned
on a regular basis.