1. Product Description
1.1 Introduction
Westlab’s Stirred Water Baths feature a digital PID temperature controller and are
designed for immersion of asks, bottles and racks in an accurate temperature
environment throughout the water bath. The stainless-steel tank is housed in a sturdy
outer case and is supplied complete with a stainless-steel shelf which provides even
water circulator and temperature stability.
The painted surfaces feature a tough antibacterial nish with good chemical resistance.
Easy to use controls which are wipe clean and have an antibacterial nish. Immersed
components are corrosion resistant. The ecient stirrer is quiet in use and provides
excellent temperature stability. Indication of heating, over temperature alarm and
timer running.
When a low liquid level is detected a “FILL” message automatically appears and heating
is suspended. Once relled, heating is restored, and temperature control resumes
automatically. Over and under temperature alarms automatically protect samples
in the water bath.
1.2 Intended Use
The Stirred Water Baths are designed for laboratory use only.
1.3 Features
• Digital LED Display
• Stainless Steel Tank
• Ambient + 5°C to 99°C
• Stainless Steel Perforated Shelf
• Made in the United Kingdom
1.4 Accessories
663-903 663-904
Flat Lid,
Stainless Steel
Suits 14L Bath
(663-898)
Suits 22L & 28L Baths
(663-899 & 663-900)
TABLE OF CONTENT
1. Product Description
1.1 Introduction
1.2 Intended Use
1.3 Features
1.4 Accessories
2. Technical Specications
3. Safety Precautions
& Maintenance
3.1 Safety Precaution
3.2 Maintenance
4. Installation & Operation
4.1 Installation
4.2 Operation
5. Product Disposal
PRODUCT CODES
663-898
663-899
663-900
663-903
663-904
PLEASE READ THESE INSTRUCTIONS BEFORE USE.
M
a
d
e
i
n
t
h
e
U
K

3
PRODUCT MANUAL
1800 358 101
sales.au@westlab.com
www.westlab.com.au
+64 9 553 3677
sales.nz@westlab.com
www.westlab.co.nz
646 568 5391
sales.us@westlab.com
www.westlab.com
1 877 822 1455
sales.ca@westlab.com
www.westlab.com
Australia New Zealand United StatesCanada
2. Technical Specication
663-898 663-899 663-900
Tank Capacity 14L 22L 28L
Temperature
Range
Ambient + 5°C to 99°C
Temperature
Alarm
Digital LED Display - Under/Over Temperature Alarm is
Automatically Set 4°C Above & 4° Below Set Point
Temperature
Control
PID Digital, LED Display, Resolution of 0.1°C
Water Level Range 130mm Maximum
Sensitivity ± 0.05°C
Uniformity ± 0.01°C
Timer Visual Indicator & End Message
– Variable 00:01 to 99:59 hh:mm
Heater Power 1,250W
Voltage 230 V, 50 to 60 Hz
Internal
Dimensions (mm)
219 W x 298 D
x 150 H
395 W x 298 D
x 150 H
395 W x 298 D
x 200 H
External
Dimensions (mm)
361 W x 332 D
x 170 H
537 W x 332 D
x 170 H
537 W x 332 D
x 290 H

4
PRODUCT MANUAL
1800 358 101
sales.au@westlab.com
www.westlab.com.au
+64 9 553 3677
sales.nz@westlab.com
www.westlab.co.nz
646 568 5391
sales.us@westlab.com
www.westlab.com
1 877 822 1455
sales.ca@westlab.com
www.westlab.com
Australia New Zealand United StatesCanada
3. Safety Precautions & Maintenance
3.1 Safety Precautions
1. This product is designed for laboratory use only. Always follow good laboratory
practice.
2. Fill the tank prior to connection to electrical supply.
3. Use caution when topping up or draining the tank. If this product is not used in
accordance with these instructions, then basic safety protection may be affected.
4. The mains supply cord tted to this product is heat resistant and should be
replaced with an equivalent type by a qualied electrician.
5. Ensure that the power supply has a safety earth (ground) terminal.
6. Ensure that the mains switch, and power supply connector are accessible during use.
7. Before using any cleaning or decontamination method please refer to the
Maintenance section to ensure the proposed method will not damage the unit.
8. Connect only to a power supply with the corresponding voltage to that specied on
the rating label positioned on the rear of the unit.
9. Do not block ventilation slots during use and always follow installation instructions.
10. Ensure substances being heated present no risk of a hazard (explosion, implosion,
or release of toxic or ammable gases) or that these have been addressed. When
heating substances where liberation of gases occurs, suitable extraction should
be used.
11. Use only liquids specied within this Instruction Manual within their specied
temperature range.
12. Drain all liquid before moving the water bath.
13. We recommend using a lid above 60˚C. Take care when lifting the lid as steam and
hot vapours can cause scolding.
14. Use a thermometer to check the temperature - do not touch the liquid.
Liquid Levels:
Always ensure that the water bath is disconnected from the electrical supply before
lling or emptying the unit.
Tank Capacity Minimum Liquid Level Maximum Liquid Level
14 & 22L 70mm above the shelf Not exceeding the ridge
in the tank
28L 130mm above the shelf Not exceeding the ridge
in the tank

5
PRODUCT MANUAL
1800 358 101
sales.au@westlab.com
www.westlab.com.au
+64 9 553 3677
sales.nz@westlab.com
www.westlab.co.nz
646 568 5391
sales.us@westlab.com
www.westlab.com
1 877 822 1455
sales.ca@westlab.com
www.westlab.com
Australia New Zealand United StatesCanada
Suitable Liquids:
Operating temperatures and recommended liquid options are as follows:
Temperature Range Options
- 20°C to Ambient 100% Heat Transfer Liquid
100% Car Antifreeze (Ethylene Glycol)
Ambient to + 99°C Distilled Water
Virkon Dissolved in Distilled Water: Proven ecacy
against bacteria (including micro bacteria), viruses,
spores, and fungi in a variety of independent tests
using different protocols.
Heat Transfer Liquid
Note: For temperatures above 60°C or below room temperature, the water bath should be covered
by a lid or layer of polypropylene spheres to achieve optimal performance.
3.2 Maintenance
Please ensure that the washing agent and sanitising agent are BSI accredited and
approved by the H&S department for use on laboratory equipment and stainless steel
within your laboratory.
ATTENTION: Disconnect the Bath from the Power Supply Prior to Cleaning
Basic Cleaning Procedure:
The stainless-steel crevice free tank should provide years of valuable service
and is resistant to chloride containing solutions, but it is important to avoid high
concentrations of halogens- particularly chloride. Halogen deposits may show as
rust which can be cleaned off with nitric acid (10%) on a cloth. WEAR PROTECTIVE
EQUIPMENT!
The water bath should be emptied at the end of each day, then for interior surfaces:
• WASH • RINSE • DRY •
For algae and slime control in water baths, please use Water Bath Conditioner AR.
Occasionally small spots may occur in the bath which resemble rust. These are usually
small ferrous particles which have oxidised. Using a stainless-steel cleanser such as
Bar Keepers Friend® will remove these marks as well as mineral deposits.
Exterior Anti-Bacterial Painted Surfaces:
The water bath should be cleaned at regular intervals by wiping external surfaces with
a cloth or sponge soaked in warm water with a mild detergent.
ATTENTION: Do Not Use Strong Solvents or Solutions Containing Chlorinated
Hydrocarbons, Esters, Ketones or Abrasive Cleaners as this may Damage the Built-In
Antibacterial Properties.

6
PRODUCT MANUAL
1800 358 101
sales.au@westlab.com
www.westlab.com.au
+64 9 553 3677
sales.nz@westlab.com
www.westlab.co.nz
646 568 5391
sales.us@westlab.com
www.westlab.com
1 877 822 1455
sales.ca@westlab.com
www.westlab.com
Australia New Zealand United StatesCanada
4. Installation & Operation
4.1 Installation
The water bath must be placed on a smooth, level, and sturdy work surface, preferably near
a drain for emptying. Use in a ventilated room. Suitable for use in ambient temperatures 5°C
to 40°C with a maximum humidity 80% (temperature 31°C) decreasing to 50% (temperature
40°C).
DO NOT block or restrict ventilation slots. DO NOT place directly next to hot heat surfaces.
ENSURE that there is sucient space around the product to allow it to provide optimum
temperature control.
When unpacking the unit, remove the packaging and retain over the warranty period.
Contents consist of:
• Water Bath
• Stainless Steel False Base
• Power Lead
• Instruction Manual
Place the false base into the bath with the legs down. Fit the power lead into the socket
at the rear.
4.2 Operation
Switch the unit on using the mains switch located on the rear. The switch will illuminate,
and the controller will perform a self-test. When the unit is switched off all time and
temperature values remain in memory.
Setting Temperature:
1. Press and hold the DOWN arrow, or the FUNCTION key to display SP1: the set
temperature. The set temperature indicator will illuminate.
2. Use the UP and DOWN arrow keys to select required temperature.
3. After setting the temperature the display ashes between SP1 and set temperature
value and will then revert to show actual liquid temperature. Heater indicator will
illuminate.
4. The water bath is now set and will heat and control the liquid to set temperature.
Setting Time:
1. Press the FUNCTION key until ‘t’ appears on the display. Display will alternate
between ‘t’ and time displayed as h:mm.
2. Use the UP and DOWN arrows to select time required. Minimum 0 hours 01 minutes:
00:01 and maximum 9 hours 59 minutes: 9:59.
3. Press the FUNCTION key to conrm. The display will ash 4 times then revert to
actual liquid temperature.

ORDERING WITH
WESTLAB IS EASY
Online
www.westlab.com.au
Order online with our easy
Express Order form for fast,
secure ordering.
Phone
1800 385 101
Speak to one of our friendly,
ecient staff from
8.00am - 5.00pm (Mon/Fri)
Email
24 hours, 7 days a week
convenience.
7
PRODUCT MANUAL
1800 358 101
sales.au@westlab.com
www.westlab.com.au
+64 9 553 3677
sales.nz@westlab.com
www.westlab.co.nz
646 568 5391
sales.us@westlab.com
www.westlab.com
1 877 822 1455
sales.ca@westlab.com
www.westlab.com
Australia New Zealand United StatesCanada
Timer Operation:
1. To start the timer, press the RUN key for more than 1.5 seconds. The timer will
automatically start once the bath has reached set temperature. Heater indicator will
illuminate continuously while liquid temperature is being raised to set point.
2. Heater indicator will ash when set temperature has been reached and is being
maintained. Timer indicator will ash showing the timer is running.
3. To view time remaining, press the UP arrow until the ‘t’ appears and time remaining
is displayed as h:mm.
4. An audible beeping and the ‘END’ message indicates timed period has nished.
Press the RUN key to deactivate the beep and clear the ‘END’ message.
Power Interrupted During Timer Mode:
If the power is interrupted during the timer mode, the display shows ‘P.OFF’ when resumed.
To clear press and hold the RUN key until display reverts to actual temperature. Timer mode
will then continue. To deactivate the timer press and hold the RUN key.
Under & Over Temperature Alarm:
The under/over temperature alarm is automatically set 4°C below/above set temperature.
When in alarm condition the ‘Under/Over Temperature Alarm’ warning indicator illuminates,
and actual bath temperature is shown. All heating/cooling is switched off. Note: if an accessory
dip cooler is being used cooling will continue. Once water temperature has risen above/fallen
below alarm setting then the indicator clears, and actual bath temperature is displayed.
NOTE: The motor remains on, while the heater is switched off.
Low Liquid Level Float Switch ‘FILL’ Message:
The water bath features a low liquid level alarm - display will read ‘FILL’. Heating will be
switched off if the liquid falls below the recommended level. Stirring action will continue.
To reset top up the liquid carefully as spitting may occur.
5. Product Disposal
In the case that the product is to be disposed of, the relevant legal regulations are to
be observed.
This manual suits for next models
4
Table of contents
Other Westlab Laboratory Equipment manuals

Westlab
Westlab 665-084 User manual

Westlab
Westlab 663-575 User manual

Westlab
Westlab 663-958C User manual

Westlab
Westlab 665-259 User manual

Westlab
Westlab 665-090 User manual

Westlab
Westlab 664-315 User manual

Westlab
Westlab Shaker 3D Bundle User manual

Westlab
Westlab IROLLJR-1200 User manual

Westlab
Westlab 665-251 User manual

Westlab
Westlab 665-134 User manual