Bimetal thermometer, models 53, 54, 55 (ATEX)
Bimetall-Thermometer, Typen 53, 54, 55 (ATEX)
Thermomètre bimétallique, types 53, 54, 55 (ATEX)
Termómetro bimetálico, modelos 53, 54, 55 (ATEX)
CE Ex
II 2G c TX X
II 2D c TX X

2
DE
EN
ES
FR
Operating instructions models 53, 54, 55 (ATEX)
Page 3-18
Betriebsanleitung Typen 53, 54, 55 (ATEX)
Seite 19-34
Mode d'emploi types 53, 54, 55 (ATEX)
Page 35-50
Manual de instrucciones modelos 53, 54, 55 (ATEX)
Página 51-66
© 12/2010 WIKA Alexander Wiegand SE & Co. KG
All rights reserved. / Alle Rechte vorbehalten.
WIKA®is a registered trademark in various countries.
WIKA®ist eine geschützte Marke in verschiedenen Ländern.
Prior to starting any work, read the operating instructions!
Keep for later use!
Vor Beginn aller Arbeiten Betriebsanleitung lesen!
Zum späteren Gebrauch aufbewahren!
Lire le mode d‘emploi avant de commencer toute opération !
A conserver pour une utilisation ultérieure !
¡Leer el manual de instrucciones antes de comenzar cualquier trabajo!
¡Guardar el manual para una eventual consulta!
11583747.04 12/2016 EN/DE/FR/ES
WIKA operating instructions models 53, 54, 55 (ATEX)

EN
Declarations of conformity can be found online at www.wika.com.
11583747.04 12/2016 EN/DE/FR/ES
WIKA operating instructions models 53, 54, 55 (ATEX) 3
Contents
1. General information 4
2. Safety 6
3. Specications 9
4. Design and function 9
5. Special conditions for use (X conditions) 10
6. Transport, packaging and storage 13
7. Commissioning, operation 14
8. Maintenance and cleaning 16
9. Dismounting, return and disposal 16
Appendix: EU declaration of conformity 18
Contents

EN
11583747.04 12/2016 EN/DE/FR/ES
4WIKA operating instructions models 53, 54, 55 (ATEX)
1. General information
■
The bimetal thermometers described in the operating instructions
have been designed and manufactured using state-of-the-art
technology. All components are subject to stringent quality and
environmental criteria during production. Our management
systems are certied to ISO 9001 and ISO 14001.
■
These operating instructions contain important information on
handling the instrument. Working safely requires that all safety
instructions and work instructions are observed.
■
Observe the local accident prevention regulations and general
safety regulations, in eect for the instrument's range of use.
■
The operating instructions are part of the instrument and must
be kept in the immediate vicinity of the instrument and readily
accessible to skilled personnel at any time.
■
Skilled personnel must have carefully read and understood the
operating instructions, prior to beginning any work.
■
The manufacturers liability is void in the case of any damage
caused by using the product contrary to its intended use,
non-compliance with these operating instructions, assignment
of insuciently qualied skilled personnel or unauthorised
modications to the instrument.
■
The general terms and conditions contained in the sales
documentation shall apply.
■
Subject to technical modications.
■
Further information:
- Internet address: www.wika.de / www.wika.com
- Relevant data sheet: TM 53.01, TM 54.01, TM 55.01
1. General information

EN
11583747.04 12/2016 EN/DE/FR/ES
WIKA operating instructions models 53, 54, 55 (ATEX) 5
Explanation of symbols
WARNING!
... indicates a potentially dangerous situation that can
result in serious injury or death, if not avoided.
CAUTION!
... indicates a potentially dangerous situation that can
result in light injuries or damage to equipment or the
environment, if not avoided.
Information
... points out useful tips, recommendations and information
for ecient and trouble-free operation.
WARNING!
... indicates a potentially dangerous situation in the
hazardous area that can result in serious injury or death, if
not avoided.
WARNING!
... indicates a potentially dangerous situation that can
result in burns caused by hot surfaces or liquids, if not
avoided.
1. General information

EN
11583747.04 12/2016 EN/DE/FR/ES
6WIKA operating instructions models 53, 54, 55 (ATEX)
2. Safety
WARNING!
Before installation, commissioning and operation, ensure
that the appropriate bimetal thermometer has been
selected in terms of measuring range, design and specic
measuring conditions.The compatibility of the wetted
parts of the process connection (thermowell, thermowell
stem) with the medium must be tested.
Non-observance can result in serious injury and/or
damage to equipment.
Further important safety instructions can be found in the
individual chapters of these operating instructions.
2.1 Intended use
These bimetal thermometers are used for measuring temperature in
hazardous areas of industrial applications.
The instrument has been designed and built solely for the intended
use described here, and may only be used accordingly.
The technical specications contained in these operating instructions
must be observed. Improper handling or operation of the instrument
outside of its technical specications requires the instrument to be
taken out of service immediately and inspected by an authorised
WIKA service engineer.
The manufacturer shall not be liable for claims of any type based on
operation contrary to the intended use.
2. Safety

EN
11583747.04 12/2016 EN/DE/FR/ES
WIKA operating instructions models 53, 54, 55 (ATEX) 7
2.2 Personnel qualication
WARNING!
Risk of injury should qualication be insucient!
Improper handling can result in considerable injury and
damage to equipment.
■
The activities described in these operating instructions
may only be carried out by skilled personnel who have
the qualications described below.
■
Keep unqualied personnel away from hazardous
areas.
Skilled personnel
Skilled personnel are understood to be personnel who, based on their
technical training, knowledge of measurement and control technology
and on their experience and knowledge of country-specic regulations,
current standards and directives, are capable of carrying out the work
described and of independently recognising potential hazards.
2.3 Additional safety instructions for instruments per ATEX
WARNING!
Non-observance of these instructions and their contents
may result in the loss of explosion protection.
WARNING!
It is imperative that the application conditions and safety
requirements of the EC-type examination certicate are
followed.
Temperature measuring instruments must be earthed via
the process connection!
Bimetal thermometers contain no internal heat source, and, when
correctly installed and operated, cause no increase in temperature!
2. Safety

EN
11583747.04 12/2016 EN/DE/FR/ES
8WIKA operating instructions models 53, 54, 55 (ATEX)
2.4 Special hazards
WARNING!
Observe the information given in the applicable type
examination certicate and the relevant country-
specic regulations for installation and use in potentially
explosive atmospheres (e.g. IEC 60079-14, NEC, CEC).
Non-observance can result in serious injury and/or
damage to the equipment.
For additional important safety instructions for insturments
with ATEX approval see chapter 2.3 “Additional safety
instructions for instruments per ATEX”.
WARNING!
Residual media in dismounted instruments can result in
a risk to persons, the environment and equipment. Take
sucient precautionary measures.
2.5 Labelling, safety marks
Product label (example)
2. Safety
Thermometer
Model
TG53 + option ATEX
14001455
year 2016
WIKA Alexander Wiegand SE & Co. KG
63911 Klingenberg / Germany
Model
Year of manufacture
Serial number
Before mounting and commissioning the instrument,
ensure you read the operating instructions!
Ex marking
II 2G c TX X
II 2D c TX X

EN
11583747.04 12/2016 EN/DE/FR/ES
WIKA operating instructions models 53, 54, 55 (ATEX) 9
3. Specications
Specications Model 53 Model 54 Model 55
Measuring element Bimetal coil
Nominal size 3", 5" 63, 80, 100, 160 63, 100, 160
Instrument version
■
Model A5x
■
Model R5x
■
Model S5x
Back mount (axial)
- Lower mount (radial)
Back mount, housing can rotate and swivel
Permissible ambient
temperature
-20 ... +60 °C max. -50 ... +60 °C
Working pressure
■
Continuous load (1 year)
■
Short term (max. 24 h)
Measuring range (EN 13190)
Scale range (EN 13190)
Case, ring Stainless steel 1.4301 (304)
Stem, process connection Stainless steel 1.4571 (316Ti)
Ingress protection IP65 per EN/IEC 60529
IP66, liquid-lled
For further specications see WIKA data sheet TM 53.01, TM 54.01
or TM 55.01 and order documentation.
4. Design and function
4.1 Description
The bimetal thermometers of this series are intended for installation in
pipelines, vessels, plant and machinery.
Sheath and case are made of stainless steel.
To allow tting to the process, dierent installation lengths and
process connections are available.
3. Specications / 4. Design and function

EN
11583747.04 12/2016 EN/DE/FR/ES
10 WIKA operating instructions models 53, 54, 55 (ATEX)
Through the high protection class of the thermometer (IP65) and its
liquid damping, operation under vibration conditions is possible.
4.2 Scope of delivery
Cross-check scope of delivery with delivery note.
5. Special conditions for use (X conditions)
1) Design temperatures
Ambient temperature: -20 … +60 °C
Medium temperature: max. +600 °C
(instruments with liquid lling: max. +250 °C)
Observe the surface temperature for ATEX application:
The permissible medium temperature does not only depend on
the instrument design, but also on the ignition temperature of the
surrounding gases, vapours or dust. Take both aspects into account.
2) Maximum surface temperature
For instruments with liquid lling, make sure that the medium
temperature is lower than 250 °C.
The surface temperature mainly depends on the medium
temperature. For prevention, consider the maximum medium
temperature as maximum surface temperature.
4. Design and function / 5. Special conditions ...

EN
11583747.04 12/2016 EN/DE/FR/ES
WIKA operating instructions models 53, 54, 55 (ATEX) 11
Instruments for use in hazardous gas/air, vapour/air and mist/air
atmospheres:
Temperature class
(gas application)
Maximum permissible surface
temperature (for the end application)
T6 +65 °C
T5 +80 °C
T4 +105 °C
T3 +160 °C
T2 +240 °C
T1 +250 °C (+360 °C) 1)
1) only for instruments without liquid lling
Hazardous dust atmosphere
For dusts, the procedure specied in ISO/IEC 80079-20-2 for
determining the ignition temperature has to be applied.The ignition
temperature is determined separately for dust clouds and dust layers,
respectively. For dust layers, the ignition temperature depends on the
dust layer thickness per EN/IEC 60079-14.
Ignition temperature
of dust
Maximum permissible medium
temperature (in the measuring system)
Dust cloud T
cloud < 2/3 Tcloud
Dust layer Tlayer < Tlayer − 75 K − (reduction depending on the
layer thickness)
The permissible maximum medium temperature must not exceed the
lowest determined value, even in case of a malfunction.
3) Mount the instrument in such a way that, taking into consideration
the inuence of convection and heat radiation, no deviation above or
below the permissible ambient and medium temperatures can occur.
4) The end user must ensure that the measuring instrument is
connected to the equipotential bonding of the end-use application via
the process connection.The sealings used at the process connection
must be electrically conductive.
5. Special conditions for use (X conditions)

EN
11583747.04 12/2016 EN/DE/FR/ES
12 WIKA operating instructions models 53, 54, 55 (ATEX)
5) Avoid handling of materials that react dangerously with the materials
used for the instrument, and substances liable to spontaneous
combustion.
6) Avoidance of vibration
Requirements for the installation point
If the line to the instrument is not adequately stable, an instrument
holder should be used for fastening. If vibrations cannot be avoided
by means of suitable installation, use instruments with liquid lling.
Protect the instruments against coarse dirt and wide uctuations in
ambient temperature.
Permissible vibration load at the installation site
Always install the instruments in locations free from vibration. If
necessary, it is possible to isolate the instrument from the mounting
point, e.g. by installing a exible connection line between the
measuring point and the instrument and mounting the instrument on
a suitable bracket. If this is not possible, do not exceed the following
limits:
Frequency range < 150 Hz
Acceleration < 0.5 g
7) When using thermowells, they must be lled with a thermal contact
medium in order to reduce the heat transfer resistance between
the outer wall of the probe and the inner wall of the thermowell.The
working temperature of the thermal compound is -40 ... +200 °C.
8) Clean the thermometer with a moist cloth. Ensure that due to the
cleaning no electrostatic charge will be generated.
5. Special conditions for use (X conditions)

EN
11583747.04 12/2016 EN/DE/FR/ES
WIKA operating instructions models 53, 54, 55 (ATEX) 13
6. Transport, packaging and storage
6.1 Transport
Check instrument for any damage that may have been caused by
transport.
Obvious damage must be reported immediately.
6.2 Packaging
Do not remove packaging until just before mounting.
Keep the packaging as it will provide optimum protection during
transport (e.g. change in installation site, sending for repair).
6.3 Storage
Permissible conditions at the place of storage:
Storage temperature: -20 ... +60 °C
Avoid exposure to the following factors:
■
Direct sunlight or proximity to hot objects
■
Mechanical vibration, mechanical shock (putting it down hard)
■
Soot, vapour, dust and corrosive gases
Store the instrument in its original packaging in a location that fulls
the conditions listed above. If the original packaging is not available,
pack and store the thermometer as described below:
1. Wrap the thermometer in an antistatic plastic lm.
2. Place the thermometer, along with shock-absorbent material, in the
packaging.
3. If stored for a prolonged period of time (more than 30 days), place a
bag, containing a desiccant, inside the packaging.
6. Transport, packaging and storage

EN
11583747.04 12/2016 EN/DE/FR/ES
14 WIKA operating instructions models 53, 54, 55 (ATEX)
WARNING!
Before storing the instrument (following operation),
remove any residual media.This is of particular
importance if the medium is hazardous to health, e.g.
caustic, toxic, carcinogenic, radioactive, etc.
The use of liquid damping is always recommended for
temperatures near the dew point (±1 °C around 0 °C).
7. Commissioning, operation
The bimetal thermometer must be earthed via the process
connection!
When screwing the instruments in, the force required to do this must
not be applied through the casing, but only through the spanner ats
provided for this purpose and using a suitable tool.
Installation with
open-ended spanner
When mounting a bimetal dial indicating thermometer that can be
rotated and swivelled, the specic instructions must be followed. In
order to set the indicator to the desired position, the following steps
must be taken:
1.The lock nut or union nut must be loosened at the process
connection.
2.The hexagon bolts and slotted screws at the swivel joint must be
loosened.
6. Transport ... / 7. Commissioning, operation

EN
Thermowell
Stem
Required safety
clearance
11583747.04 12/2016 EN/DE/FR/ES
WIKA operating instructions models 53, 54, 55 (ATEX) 15
3. Position the indicator as required, tighten the hexagon bolts and
slotted screws, and nally tighten the lock nut or union nut rmly.
loosening
Make sure to loosen the screws
on the opposite side as well!
7. Commissioning, operation
CAUTION!
When using thermowells, please
ensure that the stem does not
touch the bottom of the thermowell
since, due to the dierent
expansion coecients of the
materials, the stem may become
buckled at the bottom of the
thermowell.
(Formula for the calculation of
the insertion length l1see the
respective thermowell's data
sheet)

EN
11583747.04 12/2016 EN/DE/FR/ES
16 WIKA operating instructions models 53, 54, 55 (ATEX)
8. Maintenance and cleaning
8.1 Maintenance
These bimetal thermometers are maintenance-free!
The indicator should be checked once or twice every year. For this
the instrument must be disconnected from the process and checked
using a temperature calibrator.
Repairs must only be carried out by the manufacturer.
8.2 Cleaning
CAUTION!
■
Clean the thermometer with a moist cloth.
■
Wash or clean the thermometer before returning it, in
order to protect personnel and the environment from
exposure to residual media.
■
Residual media in the dismounted instrument can result
in a risk to personnel, the environment and equipment.
Take sucient precautionary measures.
For information on returning the instrument see chapter
9.2 “Returns”.
9. Dismounting, return and disposal
WARNING!
Residual media in the dismounted instrument can result
in a risk to persons, the environment and equipment. Take
sucient precautionary measures.
8. Maintenance and cleaning / 9. Dismounting ...

EN
11583747.04 12/2016 EN/DE/FR/ES
WIKA operating instructions models 53, 54, 55 (ATEX) 17
9.1 Dismounting
WARNING!
Risk of burns!
Let the instrument cool down suciently before
dismounting it! During dismounting there is a risk of
dangerously hot pressure media escaping.
9.2 Returns
WARNING!
Absolutely observe when shipping the instrument:
All instruments delivered to WIKA must be free from any kind
of hazardous substances (acids, bases, solutions, etc.).
When returning the instrument, use the original packaging or a
suitable transport package.
To avoid damage:
1. Wrap the instrument in an antistatic plastic lm.
2. Place the instrument, along with shock-absorbent material, in the
packaging. Place shock-absorbent material evenly on all sides of
the transport packaging.
3. If possible, place a bag, containing a desiccant, inside the
packaging.
4. Label the shipment as transport of a highly sensitive measuring
instrument.
Information on returns can be found under the heading
“Service” on our local website.
9.3 Disposal
Incorrect disposal can put the environment at risk.
Dispose of instrument components and packaging materials in an
environmentally compatible way and in accordance with the country-
specic waste disposal regulations.
9. Dismounting, return and disposal

EN
11583747.04 12/2016 EN/DE/FR/ES
18 WIKA operating instructions models 53, 54, 55 (ATEX)
Appendix: EU declaration of conformity

DE
WIKA Betriebsanleitung Typen 53, 54, 55 (ATEX)
11583747.04 12/2016 EN/DE/FR/ES
19
Inhalt
1. Allgemeines 20
2. Sicherheit 22
3. Technische Daten 25
4. Aufbau und Funktion 25
5. Besondere Bedingungen für die Verwendung
(X-Conditions) 26
6. Transport, Verpackung und Lagerung 29
7. Inbetriebnahme, Betrieb 30
8. Wartung und Reinigung 32
9. Demontage, Rücksendung und Entsorgung 32
Anlage: EU-Konformitätserklärung 34
Inhalt
Konformitätserklärungen nden Sie online unter www.wika.de.

DE
11583747.04 12/2016 EN/DE/FR/ES
20 WIKA Betriebsanleitung Typen 53, 54, 55 (ATEX)
1. Allgemeines
■
Die in der Betriebsanleitung beschriebenen Bimetall-Thermometer
werden nach dem aktuellen Stand der Technik konstruiert und
gefertigt. Alle Komponenten unterliegen während der Fertigung
strengen Qualitäts- und Umweltkriterien. Unsere Management-
systeme sind nach ISO 9001 und ISO 14001 zertiziert.
■
Diese Betriebsanleitung gibt wichtige Hinweise zum Umgang mit
dem Gerät.Voraussetzung für sicheres Arbeiten ist die Einhaltung
aller angegebenen Sicherheitshinweise und Handlungsanweisun-
gen.
■
Die für den Einsatzbereich des Gerätes geltenden örtlichen Unfall-
verhütungsvorschriften und allgemeinen Sicherheitsbestimmungen
einhalten.
■
Die Betriebsanleitung ist Produktbestandteil und muss in unmittel-
barer Nähe des Gerätes für das Fachpersonal jederzeit zugänglich
aufbewahrt werden.
■
Das Fachpersonal muss die Betriebsanleitung vor Beginn aller
Arbeiten sorgfältig durchgelesen und verstanden haben.
■
Die Haftung des Herstellers erlischt bei Schäden durch bestim-
mungswidrige Verwendung, Nichtbeachten dieser Betriebsan-
leitung, Einsatz ungenügend qualizierten Fachpersonals sowie
eigenmächtiger Veränderung am Gerät.
■
Es gelten die allgemeinen Geschäftsbedingungen in den Verkaufs-
unterlagen.
■
Technische Änderungen vorbehalten.
■
Weitere Informationen:
- Internet-Adresse: www.wika.de / www.wika.com
- zugehöriges Datenblatt: TM 53.01, TM 54.01, TM 55.01
1. Allgemeines
Other manuals for 53 Series
3
This manual suits for next models
4
Table of contents
Languages:
Other WIKA Thermometer manuals
Popular Thermometer manuals by other brands

Maverick Industries
Maverick Industries XR-40 instruction manual

VisioFocus
VisioFocus mini 06700 operating instructions

ThermoWorks
ThermoWorks Super-Fast Thermapen Guide

Kanomax
Kanomax 6841 Operation manual

Beurer medical
Beurer medical FT 90 Instructions for use

Maverick
Maverick BT-150 STAKE quick start guide