P A G E | 3
Wintex Agro, Vilhelmsborgvej 15, DK-7700 Thisted
+45 97990800, contact@wintexagro.com, www.wintexagro.com
1. STARTING THE WINTEX 1000s
Start the ATV, and deactivate the emergency stop. The red button must be up.
Activate the foot switch and the brake on the handle bar, and shortly push the button at your right
hand. Foot switch and brake lever must be activated during the entire process. If one of these
switches is released, the process will stop.
Note: The emergency stop must always be activated at long stops, or the battery might be
discharged.
2. ADJUSTING THE DEPTH
The sensor plate defines the depth which can be read on the mounted ruler. Loosen the screws, and
move the sensor plate up or down to the desired depth.
3. INTERRUPTING THE PROCESS
Due to various reasons it might be necessary to interrupt the process. In this case just deactivate the
foot switch, and the process will stop immediately. When reactivating the foot switch and the brake
handle at the same time, the probe will go back into start position. The soil will be discarded and not
be filled into the soil boxes.
If the soil sampler is delivered with a remote control, the process will be interrupted by activating the
stop switch of the remote control instead.