PG 8 OF 16
M0053.12 JULY 2019
Tandoor Installation
and Operation Manual
CLEARANCES & VENTING
REV:
DATE:
PART #:
Bellingham, WA 360/650-1111 www.woodstone-corp.com
WS-GFT-35-RND
General Arrangement
General Arrangement
10/15/2014
bena
0
DIMENSIONS ARE IN INCHES
TOLERANCES: LINEAR ±1/2 [±10mm], ANGULAR ±2°
UNLESS NOTED OTHERWISE
DWN BY:
SHEET:
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF WOOD STONE CORPORATION
ANY REPRODUCTION OR USE IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF WOOD STONE IS PROHIBITED
An ongoing program of product improvement may require us to
change specifications without notice.
C:\Users\bena\Desktop\001-5035_Dressed-0.dft
1 of 1
EQUIPMENT RESTRAINTS
IMPORTANT NOTICE FOR GAS CONNECTION TO MOVABLE APPLIANCES
When this appliance is installed with casters, it must be installed with the casters supplied, a connector complying with either
ANSI Z21�69 or CSA 6�16 and a quick disconnect device complying with ANSI Z21�41 or CSA 6�9� It must also be installed with
restraining means to guard against transmission of strain to the connector, as specified below�
ATTENTION INSTALLER:
EQUIPMENT RESTRAINT MUST BE PROVIDED
Adequate means must be provided to limit the movement
of the appliance without depending on the connector
and the quick disconnect device or its associated piping
to limit the appliance movement� The hole to attached the
restraining device is in the Burner Assembly frame toward
the rear of the unit, near the gas inlet�
Rear view
Hole to attach restraining device
Combustible construction overhanging
the appliance should be protected in a
manner acceptable to the authority having
jurisdiction.
Install on a noncombustible floor, or one protected in a manner
acceptable to the authority having jurisdiction, extending 36 inches
in all directions.
INSTALLATION CLEARANCES
The Square and Round Tandoor models must be installed with at least
1-inch side clearance to combustible construction� Barrel models require
a minimum of 5" of clearance to combustible contruction� Install the
unit on a non-combustible floor, or one provided with a non-combustible
covering that extends at least 36-inches in all directions� Any combustible
construction above (overhanging) the appliance should be protected in a
manner acceptable to the authority having jurisdiction�
Do not obstruct the flow of combustion and ventilation air.
Position unit to allow access to unit for servicing.
ENCLOSURES
If the appliance is enclosed, provisions should be made so that it can easily
be removed from the enclosure for service and maintenance�
VENTING
The Wood Stone gas-fired Tandoor must be installed under an appropriate NFPA 96 approved Type 1 exhaust hood� Refer to
local and/or national codes for hood specification requirements� The hood must be designed for the removal of the combustion
products of gas, as well as the cooking vapors related to the intended use of the oven�
Some jurisdictions may require that the Tandoor be interlocked to the hood ventilation system to prevent operation of the
appliance when the ventilation system is not turned on� If an interlock is required, use an approved gas solenoid (supplied and
installed by others), wired so that the gas supply to the appliance is turned off whenever the ventilation system is turned off�
!WARNING: Do not pack required air space (clearance) with insulation or other materials. When
non-combustible building materials contact the body of the oven, the clearances to combustibles
are transferred to those non-combustibles.
Shaded area must be left unobstructed for critical combustion air and
easily accessible for removal of the drip/debris pan and operation of
the pilot safety valve. If this area must be covered, the cover should
be easily removable and heavily perforated.
Round or Square models:
1" side clearance
to combustible construction
Barrel models:
5" side clearance
to combustible construction