Installation
Mounting Guidelines
NetworkHD components should be installed on a flat, level surface such as a table, cabinet, shelf, or wall. location should be dry, well
ventilated, and out of direct sunlight. Units should never be flat stacked without space between the units for ventilation and the side
vent holes should not be obstructed.
Rack Mounting
For AV and IT racks, WyreStorm offers rack mount kits to allow for quick and easy installation that provides a clean properly
ventilated installation. All rack mount kits provide a steel housing that can be used in a central and secure location for the
components.
NHD-000-RACK is designed for use with 100/200 series encoders
NHD-000-RACK2 is designed for 100/200/400 series encoders
NHD-000-RACK3 is designed for 600 series encoders and decoders
Note: The NHD-200-TX has dipswitches to set the video source format, these switches should be set before mounting the NHD-
200-TX. Refer to NHD-200-TX Dipswitch Settings for details.
Wiring and Connections
WyreStorm recommends that all wiring for the installation is run and terminated prior to making connections to the switcher. Read
through this section in its entirety before running or terminating the wires to ensure proper operation and to avoid damaging
equipment.
IMPORTANT! Wiring Guidelines
•The use of patch panels, wall plates, cable extenders, kinks
in cables, and electrical or environmental interference will
have an adverse effect on signal transmission which may
limit performance. Steps should be taken to minimize or
remove these factors completely during installation for best
results.
•WyreStorm recommends using pre-terminated HDMI and
DP cables due to the complexity of these connector types.
Using pre-terminated cables will ensure that these
connections are accurate and will not interfere with the
performance of the product.
LAN Port Wiring
The NetworkHD 600 Series LAN port is a 1GbE link for
connection to a 1000BASE-T Ethernet device port. Refer to IEEE
802.3ab for official guidance on the Ethernet link. Cables must be
tested to 100MHz across the entire link. 1000BASE-T uses the
IEC 60603-7 8P8C modular connector
SDVoE Wiring
The NetworkHD 600 Series utilize a 10GbE link connection to a
10GBASE-T Ethernet switch port. Refer to IEEE 802.3an for
official guidance on the Ethernet link. Cables must be tested to
500MHz across the entire link. 10GBASE-T uses the IEC 60603-7
8P8C modular connector
IMPORTANT! IR TX/RX Guidelines
Using WyreStorm infrared emitters and receivers is the best way
to ensure that most IR coding formats are transmitted and
received by the NetworkHD system. Other 3rd party emitters and
receivers can be used; however, these devices must operate in
the same manner as the WyreStorm devices.
On the 100/200/400 series the IR data modulation (carrier)
frequency is passed through NetworkHD from the receiver to the
emitter, however on the 600 series the carrier frequency is fixed
at 38kHz when used in pass-through mode. When using the API
the carrier frequency can be defined for greater compatibility.
Due to differences in IR across 3rd party control systems their IR
ports should never be connected directly to a NetworkHD system
as an incompatibility may exist. WyreStorm offers a cable that
compensates for voltage differences as well adjusts for
differences in the pins used within the port. Refer to the CAB-IR-
LINK product page for more information.
IR TX Port Pinout
Connection for IR TX (transmit) uses a 3.5mm (1/8in) mono
plug.
IR RX Port Pinout
Connection for IR RX (receive) uses a 3.5mm (1/8in) stereo jack
that outputs +5V DC to power the included IR receiver.