Yamato UDS-1V-WP User manual

al
DIGITAL UNIVERSAL SCALE
UDS-1V-WP
OPERATION MANUAL
Read this manual and keep it handy
YAMATO SCALE CO., LTD.
EXPORT-0703

Preface
Thank you for having purchased UDS-1V-WP.
This innovative scale is useful in a wide range of commercial activities at factories
and general stores as well as in the fishery, greengrocery and agricultural industries.
This scale features many functions.
Please read carefully this Operation Manual and take advantage of the descriptions in
it to use Yamato’s UDS-1V-WP in the optimum condition for the longest life.
TABLE OF CONTENTS
PAGE
SAFETY PRECAUTIONS··············································································· 1
INSTRUCTIONS AND DIRECTIONS FOR USE·················································· 3
FUNCTIONS ······························································································ 4
PRODUCT PACKAGE ··················································································· 5
NAMES OF PARTS······················································································· 5
TO KEEP THE SCALE WORKING EFFICIENTLY ··············································· 6
INSTALLATION ···························································································· 7
DISPLAYAND KEYBOARD···········································································11
CALIBRATION ····························································································12
BASIC OPERATION·····················································································13
TARE OPERATION······················································································14
USER PARAMETER ····················································································15
HOW TO CHANGE USER PARAMETER··························································17
MULTI-FUNCTION·······················································································20
FIXED WEIGHING FUNCTION ······································································22
CHECKWEIGHING FUNCTION······································································27
GRADING FUNCTION··················································································30
ERROR MESSAGES····················································································34
SPECIFICATIONS ·······················································································36

1
SAFETY PRECAUTIONS
Read carefully SAFETYPRECAUTIONS before use, and follow all the instructions.
SAFETY PRECAUTIONS are designedfor protecting users, other peoples and assets from physical
and financial damages by your safety practices.
This OPERATION MANUALshould be kept for the entire service life of the product.
The hazardous levels and descriptions are defined as follows:
Danger : Denotes where mishandling without compliance with this sign has a
potential risk of suffering death or serious injury.
Warning : Denotes where mishandling without compliance with this sign has a
potential risk of suffering injury ordamage on theproperty.
Caution : Denotes a potential risk that may result in injury or damage on the
equipment if operated without compliance with this sign.
Inhibition : Denotes what is inhibited.
Compulsion : Denotes what must be followed.
NOTE: Prior to use, read carefully the following descriptions of Danger, Warning and Caution to
understand and comply with them.
Danger
: ToAvoid Electrical Shock:
Do not step on the power cable of anAC adaptor under the feet or other devices including a cart.
Connect or disconnect the AC adaptor securely by holding a plug section of the AC adaptor. Do not
plug in or plug out anAC adaptor with wet fingers, which maycause electricalshock.
: ToAvoid Explosion and Fire:
Explosion proof function is not equipped with this equipment.
Avoid using in any area having steam, flammable gases and/or hazardous materials.
: ToAvoid Fire and Electrical Shock:
When a smoke or odd smell is found, immediately disconnect the power cable. Continued use may
result in fire and/or electrical shock.
Contact the retailer from which the equipment was purchased for repair after confirming the
equipment ceases to smoke. Neverfix it by yourself, which may result in hazardous consequences.

2
Warning
: Do Not Use on Unstable Surface:
An inclined equipment may fall down and cause an unexpected accident. When a equipment is
used on a table, special care is required for securing the safe operation.
: Do Not Hold the Pan when Carrying
The pan may detach from the body, and the main body may fall on and injure the foot.
: Do Not Put Fingers into Openings or Holes of Scale:
This may cause you to be injured or the equipment to be damaged.
: Do NotTouch Liquid from Damaged Display with the Mouth
The liquid is toxic. Special care is required to avoid any accidental contact with the mouth.
Caution
: Do Not Use Batteries Other than Specified:
Broken batteries or leakage may result in fire, injury or taint damage.
: DoNot Heat Batteries or Put in Fire or Water:
Otherwise, batteries may burst.
: Set Batteries Correctly as Instructed for Polarity:
Otherwise, batteries may leak or burst.
: Do Not Lick Batteries or Put in the Mouth
Keep batteries out of the reach of small children.
: Do Not Leave Run out Batteries in the Equipment
Batteries may leak and cause the inside of the equipment to be corroded.
: Do Not Drop the Equipment
It damages the equipment.
: Do Not Disassemble or Remodel the Equipment
Do not remove the seal. Do not disassemble or remodel the equipment. The tampered scale may
not be accepted as a equipment used for certification, or as a proper equipment eligible for
after-sales service.

3
INSTRUCTIONS AND DIRECTIONS FOR USE
Causes of Malfunction
1. Do not press the display and keys with the tip of the nail or anything sharp.
2. Make sure to hold the handgripswith the both hands when the equipment is carried or moved.
3. Do not apply excessive shock or vibration.
4. Do not drop anything or jump on the equipment. It should be also avoided to drop down the equipment. If you
drop the scale or have a strong impact on it, turn the power off immediately. (And disconnect the plug from the
outlet if operating with AC adaptor.) If you operate the scale as it is, it may cause fire, electrical shock or scale’s
malfunction. Contact your nearest sales representative.
5. The equipment is not washable. Clean with wet cloth with water orneutral detergent and wipe with dry cloth. Do
not apply thinner, benzene or alcohol.
6. No disassemble or remodel is allowed. The inner components may injure your hands and other parts.
7. Do not put the equipment upside down (the pan down) except when batteries are replaced.
8. As for all optional devices or parts connected to the UDS-1V-WP, use the devices or parts specified by Yamato.
Please note that we cannot assume responsibility for any troubles caused by devices/ parts which are not
specified by us and repair or modifications.
Causes of failure in weighing
1. Avoid using the equipment in any place close to fire and steam, or under direct sunlight and wind from the air
conditioner.
2. The equipment should not be located close to the equipment that generates strong electromagnetic waves.
(microwave oven, cellular phone, etc.) And do not use the scale close to an electrical device operating
high-accuracy control or faint signals.
3. Use the equipment on a horizontal and stable table or floor that is robust enough to support the load.
4. Use the equipment at the specified operation environment (working temperature: -10˚C and +40˚C, 30%RH to
85%RH). And avoid rapid change in temperature. The inner pressure may cause instability of weight display.
For example, if you move and use the scale in a place where the difference in temperature is more than 10˚C,
use it after 5 minutes or more.
Dry batteries
1. Do not use alkaline batteries and manganese batteries in mixing. It may cause battery leakage/ burst or
damage of scale.
2. Replace batteries immediately when the battery level indicator shows that they are running out. Replace all the
4 batteries at atime. Combination with an oldbattery results in leakage or extremely short life.
3. Set batteries correctly as shown by the polaritymarks (+ and -). Incorrect installationdamages the equipment.
4. Remove batteries when the equipment is left unused for a long time (about 1 month or longer), otherwise, they
may leak and cause the inside of the equipment to be corroded.
5. Remove batteries from the equipment when it is used with the AC adaptor. Make sure not to operate the
equipment both with batteries and theAC adaptor.
Storage and Disposition
Storing Place
1. Do not store the equipment in the place with high temperature/humidity or receiving direct sunlight for a long
period of time. It should also be noted that substantial changes in the ambient temperature may cause
condensation inside the equipment, resulting in a failure of the operation.
2. This is an electronic precision equipment. Do not store it in the place where vibration and/or shock can be
expected.
3. Do not store and use the equipment in the place with rapid change in temperature, high humidity or dusty
environment. It maycause malfunction, electrical shock or fire.
Disposal
1. When the equipment is disposed of:
The equipment must be disposed of as an industrial waste (nonflammable waste). Make sure to observe the
local regulations when disposing.

4
2. When used batteries are disposed of:
Cover the electric poles with scotch tape before disposing (to avoid hazardous short circuit). Make sure to
observe the local regulations when disposing.
Daily Checkup at Start Time
Prior to operation, conduct a daily checkup and weight test to secure the correct measurement that is required by the
Measurement Law.
Others
1. The contents of this operation manualare subjectto change without notice.
2. The configurations and specifications of the equipment are subject to change without notice. Please note that
some descriptions on the manual may be different from the configurations and specifications of the devices and
parts, due to the change of the optional devices and parts connected to the scale.
3. Please contact our local retailer when there are any suggestions about the contents of this manual.
4. All images preinstalled in the scale are protected by copyright. Even if by any chance you are entered the
writer’s claim for compensation, we cannot assume responsibility for the troubles.
REQUEST
When cleaning the scale, disconnect the plug ofAC adaptor if you use and wipe off the dirt with a
soft cloth. If it shows dirt, soak a cloth in mild detergent diluted by adding water, wring it well and
wipe out the dirt.
FUNCTIONS
The UDS-1V-WP has the following functions. Use these functions in accordance with your purpose.
Function /Application How to use the function Page
Auto-off Timer
You want to shut down the scale
automatically when operating by
batteries.
The scale is set to shut down for 15 minutes after
no use before shipment. The setting can be
changed following instructions on “Parameter
Setting”.
16
Tare
You want to display the weight of
items or a empty container as “0”. One-touch tare is available with key. 13
Fixed Weighing
When packing items, you want to
boost process yield.
Max. 99 items datacan be registered. Call up the
desired data and the range of process yield can
be grasped visually with bar charts.
21-25
Checkweighing (over/under)
You want to know in which ranges
the weighing items liesuch as under
weight, acceptable weight and over
weight for the target weight.
The upper and lower limit of max. 99 items can be
registered. Call up the desired item and you can
grasp the current weight is under weight,
acceptable weight or over weight for the target
weight intuitively with bar charts.
26-28
Grading
You want to sort the items foreach
target weight.
The data of max. 12 items, 15 ranks per item or
max. 66 items, 2 ranks per item can be
registered. Call up the desired No. of ranks. The
items are sorted in accordance with its weight and
numbered.
29-32

5
PRODUCT PACKAGE
NAMES OF PARTS

6
TO KEEPTHE SCALE WORKING EFFICIENTLY
1. This waterproof digital scale is graded as IP68. IP68 is the grade of protection against complete,
continuous submersion in water. The scale is designed not to admit water even after it has been left
at a depth of one meter for 24 hours. However, this is just the test condition. Therefore it is strongly
recommended that submerging and washing the whole scale in water should be avoided in general
use, because submerging in water may cause the deterioration of parts and cannot keep the IP68
waterproof level.
※ IP Standards
They are a code indicating the level of waterproof and dustproof performance defined on the basis of
JIS (Japanese Industrial Standards) C0920 and IEC (International Electrotechnical Commission)
529. They are widely applicable around the world.
2. When washing the whole scale, apply clean water and then wipe it with a dry clean cloth. Do not
apply seawater, dirty water and water including impurity, all of which can be cause of trouble.
3. If the scale becomes dirty, wipe it with a soft cloth. Do not use a scourer, scrub brush and so on.
4. Do not submerge the scale body that is removed the pan and pan support from the complete scale in
water including hypochlorous acid, which can cause deterioration of the parts. When washing the
scale body with hypochlorous acid, apply water spray to it. After that, make sure to rinse the scale in
clean water and wipe it thoroughly with a dry cloth.
5. When disinfecting the pan and pan support with hypochlorous acid, soak them in water whose
hypochlorous acid concentration is 200 ppm or below for 5 to 10 minutes and then rinse in clean
water and wipe them thoroughly with a dry cloth.
6. When washing the pan and pan support with a neutral detergent, apply a little neutral detergent to a
sponge and wipe them. Make sure to rinse them in clean water and wipe it thoroughly with a dry
cloth.
7. When disinfecting the complete scale with alcohol, apply solution whose alcohol concentration is
80% or below. Rinse the plastic part and front mask in clean water. Rinse the plastic parts and front
mask in clean water.
8. Do not loosen any screws. Do not disassemble or modify the scale, you will void the
waterproofness. If you disassemble it by mistake, make sure to contact your dealer.
9. Do not drop the scale or hit against something hard such as a table, the scale may have cracks on
the housing and its waterproofness will deteriorate.
10. Do not open the battery lid in an extremely dusty environment. If foreign matters adhere to the
gasket, it may affect the waterproofness.
11. When exchanging the batteries, wipe a drop of water thoroughly with a dry clean cloth.
12. After replacing batteries, fasten the battery lid tightly. (Refer to page 7 ; How to set batteries.)
13. Do not press the part s of display, key switches and gasket with your nail or edged tools.
14. If dust or foreign matters get stuck in the lower diaphragm, take it away. (Refer to the instructions on
page 9)

7
INSTALLATION
How to set batteries
Note:
Carefully avoid excessive force on the scale when it is turned over.
Adrop and/or excessive force may damage the scale.
1. Turn over the scale.
2. Wipe off the water or dust on the scale with a dry
cloth.
3. Turn the battery lid screw to open the
battery lid.
4. Remove the battery lid.
5. Wipe off the water or dust around the
battery box with a drycloth.
6. Set batteries correctly according to the polarity
marks (+, -) shown inside the battery box.
Incorrect set may damage the scale.
7. Check the batteries are set firmly, or the
battery lid cannot be fully closed and its
waterproof cannot be kept.

8
8. Hang the tabs.
9. Rotate the set screw 90 degrees
clockwise to close the battery lid tightly.
Note) Make sure that both tabs are hanged firmly, or its waterproof cannot be kept and the scale
are damaged.
How to set AC adaptor (Option)
Note: The waterproof is not effective when using theAC adaptor.
1. Use the specificAC adaptor. Connection with
an unsuitable adaptor may cause the damage.
2. Batteries cannot be used at the same time,
make sure to remove all batteries and then
use anAC adaptor.
3. Remove the battery lid from the main body.
4. Peel off the waterproof stickers attached to the
battery lid andAC adaptor.
5. Put theAC plug through the hole of battery lid.
6. Firmly insert the plug of theAC adaptor into the
jack.
7. Close the battery lid.
When operating the scale by AC adaptor, peel
off the waterproof sticker on the battery lid.

9
How to clean the Lower Diaphragm
Note:
Carefully avoid excessive force on the scale when it is turned over.
Adrop and/or excessive force may damage the scale.
1. Turn over the scale.
2. Wipe off the water or dust on the scale with
a dry cloth.
3. Remove the cover.
4. Remove the dusts by fingers. Carefully
avoid excessive force on the rubber and not
to damage the rubber.
5. Hang the hook and close the cover.

10
Place the scale
Make sure that the scale is placed on a leveled surface, or a correct measurement cannot be
attained.
Make sure that the scale is not shaky, which also results in an incorrect measurement.
Do not place the scale on an inclined surface (if the inclination is beyond the adjustable range by the
leveler).
The bottom of the scale is equipped with 4 leveling legs with which the scale is adjusted to be on the
level. Turn the leveling legs until the bubble locates at the center of the benchmark circle. It is
recommended that the adjustment is conducted on a flat surface. Make sure that all the 4 legs
equally touch the floor.
How to interpret bubble position
The length of the leg is adjusted by
turning the leveling leg.
The location of the bubble shows the
horizontal status of the scale.

11
DISPLAYAND KEYBOARD
< DISPLAY PART >
*1 The battery residual capacity is shown by 3 levels when they are consumed.
*2 The indicator is lit while the Checkweighing function is operated.
The indicator blinks while the Checkweighing function is set.
*3 The indicator is lit while the Fixed weighing function is operated.
The indicator blinks while the Fixed weighing function is set.
*4 The indicator is lit while the Grading function is operated.
The indicator blinks while the Grading function is set.
*5 The indicator is lit in accordance with the ongoing operations.
(Total bar chart: 15 segments)
< KEY PART >
ON/OFF key Turns the power on, and turns the power off.
Tare key Tares off the weight on the scale pan.
Zero reset key Zeros the display.
*key Changes the setting value at Fixed weighing, Checkweighing and
Grading functions.

12
CALIBRATION
When you use the UDS-1V-WP for the first time, it is necessary to calibrate the scale at your area
before use. If you skip the calibration, the scale may not indicate the weight with accuracy.
Therefore be sure to calibrate the scale at your area before using scale.
1) Electrical Calibration
The scale is equipped with the function of Gravity compensation (User Parameter # 09). It is
available to set the value that is appropriate for the area the scale is used. The value can be
evaluated by the below calculating formula
Calculating formula: (Acceleration of Gravity (m/s2) – 9.7600) x 10000 / 5 + 30 (offset)
*9.7600 = Fixed value
Example: Sao Paulo, Brazil (Acceleration of gravity = 9.7862 m/s2)
Setting value = (9.7862 – 9.7600) x 10000 / 5 + 30 = 82.4 82 (round off)
Change the setting value to “82” on the User Parameter # 09 based on the procedure
described in HOW TO CHANGE USER PARAMETER (Page 17).
< NOTE >
・ When you use the scale next time, it is not necessary to calibrate the scale any more. It is
possible to weigh an item after the scale is turned on.
・ When you calibrate the scale with weights outside the area (9.796 to 9.799 m/s2), the procedures
for electrical calibration as follows.
1. Evaluate the setting value of the calibration area based on the above calculating formula and
change the parameter #09 to the evaluated value.
2. Calibrate the scale with standard weight on site.
3. If you use the scale outside the calibration area, evaluate the setting value of the area where
the scale is used and change the parameter #09 to the evaluated value again.
2) Calibration with Standard weight
When you calibrate the scale with standard weight, prepare the Class M1 standard weights
equivalent to the scale capacity. Calibrate the scale according to the following procedure.
e.g.) Calibrate the scale, capacity 6 kg.
Operation Display
1 While pressing , press to enter the user parameter
setting mode.
2 While pressing , press to enter the calibration
mode.
Press to cancel the calibration mode. The display
returns to the normal weighing mode.
* It is possible to cancel it at any point in the calibration
process by pressing key.

13
3 Confirm that the pan is empty, and then press .
4 Put the standard weight of 3,000 g in the center of the pan
and press .
5 Put the 3,000 g weight additionally (Total 6,000 g) inthe
center of the pan and press .
When the calibration has finished, the display will show
6000.
Confirm that the weight indication is accurate with standard
weight.
BASIC OPERATION
Operation Display
1 Press to turn on the scale.
The display shows zero after all the indicators blinks.
2 When zero does not appear since the zero point is not
correctly recognized:
Press .
Zero appears on the display.
3 Place the item(s) on the pan.
The display shows the weight of the item.
The stable indicator is lit when the weight becomes stable.
4 To turn off the scale, keep pressing .

14
TARE OPERATION
Tare operation is used when you want to display the net weight that is deducted a container weight
from the total weight. (Tare means a container.)
Operation Display
1 Place an empty container on the pan.
The weight of the container (e.g. 25 g) is shown on the
display.
2 Press after the stable indicator is lit.
The NET indicator is lit and the display shows zero.
3 Start of weighing
Place the item(s) in the container on the pan.
The display shows the net weight of the item (e.g. 150 g).
4 Cancellation of tare
Remove the container from the pan.
The display shows the weight of the container as a negative
number.
5 Press .
The NETindicator goes out and thedisplay shows zero.

15
USER PARAMETER
The UDS-1V-WP has 3 functions that can be used in accordance with the application. Set the user
parameter before using the scale based on the following parameter list.
USER PARAMETER LIST
Parameter Description Availableparameter
01 Function Select 000:
001:
002:
003:
Suspend functions (default)
Fixed Weighing
Checkweighing
Grading
02
Number of grading ranks 000:
001-015: Suspend function
006 (default)
03 Buzzer
000:
001:
002:
003:
004:
No sound (default)
Beep at under weight
Beep at acceptable weight
Beep at over weight
Beep at under & over weight
04 Rank judgment 000:
001: Rank judgment even at instability (default)
Rank judgment at stability
05
Auto-offTimer
000:
001:
002:
003:
004:
005:
NoAuto-off
5 minutes after no use
10 minutes after no use
15 minutes after no use (default)
30 minutes after no use
60 minutes after no use
06 Auto-tare at fixed weighing
function 000:
001: Auto-tare OFF (default)
Auto-tare ON
07 Flicker of weight display 000:
001:
002:
003:
004:
005:
No flicker (default)
Flickers at under weight
Flickers at acceptable weight
Flickers at over weight
Flickers at under & over weight
Flickers with the parameter # 03 settings.
09 Gravity compensation 000:
001-029:
030-210:
No compensation
Prohibit to set
(Acceleration of Gravity(m/s2) – 9.7600) x
10000 / 5 + 30 (offset)
10 – 19 Settings on Communications 000: No serial interface (Prohibit to change at no
Bluetooth communication)
EXPLANATION OF EACH USERPARAMETER
Parameter# 01: Function Select
The UDS-1V-WP has Fixed weighing function, Checkweighing function and Grading function.
Choose the desired function for your purpose at parameter # 01.
Note) When changing the function, all setting values in the previous function will be canceled.

16
Parameter# 02: Number of Grading Ranks
At grading function, the restriction of number of grading rank can increase the registered items
numbers. Set the value with the greatest number of ranks in your handling items. The relation
between rank numbers anditems numbers that can be registered at maximum is as followings.
< Grading Function >
No. of Rank Max. Item No. No. of Rank Max. Item No. No. of Rank Max. Item No.
02 66 items 07 24 items 12 15 items
03 49 items 08 22 items 13 14 items
04 39 items 09 19 items 14 13 items
05 33 items 10 18 items 15 12 items
06 28 items 11 16 items
Parameter# 03: Buzzer
When operating the fixed weighing function or checkweighing function, buzzer can be sounded in
the setting range at stable.
Parameter# 04: Rank judgment
At grading function, when you want to judge the rank at only stability after placing items on the pan,
set the parameter # 4 at 001.
Parameter# 05:Auto-off Timer
The auto-off timer can be selected by changing the setting value.
Parameter# 06:Auto-tare at fixed weighing function
At fixed weighing function, when you want to tare off a container weight automatically, set the value
at 001. When the scale displays “0”, the weight of anything placed on the pan first time is tared off
automatically.
Parameter# 07: Flicker of weight display
At fixed weighing, checkweighing and grading function, if you want to flicker the display, set the
parameter# 7 at 001, 002, 003, 004 or 005. At grading function, the display flickers in any setting
(001 to 005).
Parameter# 09: Gravity compensation
The UDS-1V-WP (non-trade use) is equipped with the function of Gravity compensation. It is
available to set the value that is appropriate for the area the scale is used. The value can be
evaluated by the below calculating formula.
Calculating formula : (Acceleration of Gravity (m/s2) – 9.7600) x 10000 / 5 + 30 (offset)
*9.7600 =Acceleration of Gravity atAkashi, Japan

17
HOW TO CHANGE USER PARAMETER
3) How to change the setting ofAuto-off Timer (Parameter No. 05)
e.g.) Change the setting value at Parameter No. 05 from 003 (15 min. after no use) to 005 (60 min.
after no use).
Operation Display
1 Press to turn on the scale.
2 While pressing , press to enter the parameter
setting mode.
3 Press to move the parameter No. from 01 to 05.
Note) When passing by “05”, keep pressing until looping
back to “05”.
4 Press or to change the value to “005”.
Note) key : move the value forward (+1)
key : move the value backward (-1)
5 Press to store the setting value. The display goes to the
next parameter.
Note) The setting value is not saved unless the display goes
to the next parameter.
6 Press for a while to turn the power off.
7 Press to turn the power on.
The auto-off timer has been set.

18
4) How to change the setting of Buzzer (Parameter No. 03)
e.g.) Change the setting value at Parameter No. 03 from 000 (No sound) to 003 (Beep at over
weight).
Operation Display
1 Press to turn on the scale.
2 While pressing , press to enter the parameter
setting mode.
3 Press to move the parameter No. from 01 to 03.
Note) When passing by “03”, keep pressing until looping
back to “03”.
4 Press or to change the value to “003”.
Note) key : move the value forward (+1)
key : move the value backward (-1)
000 No sound
001 Beep at under weight
002 Beep at over weight
003 Beep at acceptable weight
004 Beep at under & over weight
5 Press to store the setting value. The display goes to the
next parameter.
Note) The setting value is not saved unless the display goes
to the next parameter.
6 Press for a while to turn the power off.
7 Press to turn the power on.
The beep setting has been ready.
Table of contents
Other Yamato Scale manuals

Yamato
Yamato DKS-3002 User manual

Yamato
Yamato PPC-300WP User manual

Yamato
Yamato DP-6200 User manual

Yamato
Yamato AW-300P User manual

Yamato
Yamato PPC-200W User manual

Yamato
Yamato PB-200 User manual

Yamato
Yamato AW-WLG Series User manual

Yamato
Yamato PLS Series User manual

Yamato
Yamato AW-WLG Series User manual

Yamato
Yamato Delicell User manual

Yamato
Yamato DP-5602 User manual

Yamato
Yamato Accu-weigh PPC-200 User manual

Yamato
Yamato SPC Series User manual

Yamato
Yamato DP-6700 User manual

Yamato
Yamato DP-6900 User manual

Yamato
Yamato DSR-200 User manual

Yamato
Yamato DSR-200 User manual

Yamato
Yamato DSR-400 User manual

Yamato
Yamato SPC - Solar User manual

Yamato
Yamato BC-10 User manual