manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Zamel
  6. •
  7. Switch
  8. •
  9. Zamel exta WZH-01 User manual

Zamel exta WZH-01 User manual

Other Zamel Switch manuals

Zamel exta APM-10 User manual

Zamel

Zamel exta APM-10 User manual

Zamel GRL-01 User manual

Zamel

Zamel GRL-01 User manual

Zamel Ynsta PDJ-213P User manual

Zamel

Zamel Ynsta PDJ-213P User manual

Zamel YNSTA PDJ-213 User manual

Zamel

Zamel YNSTA PDJ-213 User manual

Zamel stiro RWS-211D/N User manual

Zamel

Zamel stiro RWS-211D/N User manual

Zamel WZM-01 User manual

Zamel

Zamel WZM-01 User manual

Zamel EXTA APM-20 User manual

Zamel

Zamel EXTA APM-20 User manual

Zamel GRM-10 User manual

Zamel

Zamel GRM-10 User manual

Zamel Ledix WDN-03 User manual

Zamel

Zamel Ledix WDN-03 User manual

Zamel exta WZM-01 Series User manual

Zamel

Zamel exta WZM-01 Series User manual

Zamel Ledix WDN-01 User manual

Zamel

Zamel Ledix WDN-01 User manual

Zamel RWS-311D/Z User manual

Zamel

Zamel RWS-311D/Z User manual

Zamel GRG-01 User manual

Zamel

Zamel GRG-01 User manual

Zamel WZM-01/SOS User manual

Zamel

Zamel WZM-01/SOS User manual

Zamel EXTA WZM-02 User manual

Zamel

Zamel EXTA WZM-02 User manual

Zamel TWILIGHT SWITCH WZM-02 User manual

Zamel

Zamel TWILIGHT SWITCH WZM-02 User manual

Zamel RWS-311D/Z User manual

Zamel

Zamel RWS-311D/Z User manual

Zamel RWS-311D User manual

Zamel

Zamel RWS-311D User manual

Zamel stiro RWS-211J/N User manual

Zamel

Zamel stiro RWS-211J/N User manual

Popular Switch manuals by other brands

SMC Networks SMC6224M Technical specifications

SMC Networks

SMC Networks SMC6224M Technical specifications

Aeotec ZWA003-S operating manual

Aeotec

Aeotec ZWA003-S operating manual

TRENDnet TK-209i Quick installation guide

TRENDnet

TRENDnet TK-209i Quick installation guide

Planet FGSW-2022VHP user manual

Planet

Planet FGSW-2022VHP user manual

Avocent AutoView 2000  AV2000BC AV2000BC Installer/user guide

Avocent

Avocent AutoView 2000 AV2000BC AV2000BC Installer/user guide

Moxa Technologies PT-7728 Series user manual

Moxa Technologies

Moxa Technologies PT-7728 Series user manual

Intos Electronic inLine 35392I operating instructions

Intos Electronic

Intos Electronic inLine 35392I operating instructions

Cisco Catalyst 3560-X-24T Technical specifications

Cisco

Cisco Catalyst 3560-X-24T Technical specifications

Asante IntraCore IC3648 Specifications

Asante

Asante IntraCore IC3648 Specifications

Siemens SIRIUS 3SE7310-1AE Series Original operating instructions

Siemens

Siemens SIRIUS 3SE7310-1AE Series Original operating instructions

Edge-Core DCS520 quick start guide

Edge-Core

Edge-Core DCS520 quick start guide

RGBLE S00203 user manual

RGBLE

RGBLE S00203 user manual

Thrustmaster FLIGHT SIMULATOR X quick guide

Thrustmaster

Thrustmaster FLIGHT SIMULATOR X quick guide

Southwire SURGE GUARD 41390 RVC troubleshooting guide

Southwire

Southwire SURGE GUARD 41390 RVC troubleshooting guide

Buhler Nivotemp NT 61 Brief instructions

Buhler

Buhler Nivotemp NT 61 Brief instructions

Kramer VS-41HDCP user manual

Kramer

Kramer VS-41HDCP user manual

Techly IDATA AU-270 user manual

Techly

Techly IDATA AU-270 user manual

Belkin F1U109 user manual

Belkin

Belkin F1U109 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

TWILIGHT SWITCH WZH - 01 INSTRUCTION MANUAL
APPEARANCE
FEATURES
TECHNICAL PARAMETERS
DESCRIPTION
ver. 0.4.1 _ 2006.06.27_14:00
WZH - 01
Power supply cables: L (black), N (blue)
Input rated voltage: 230 V~
Input voltage tolerance: from -15 to +10 %
Nominal frequency: 50 / 60 Hz
Rated power consumption: 24 mA
Output (load) cables: L (brown) , N (grey)
Threshold adjustment range: from 0 to 200 lx (potentiometer)
Lighting sensor: inner
Output relay parameters:
1NO-16 A / 250 V AC1 4000 VA (voltage contact)
Number of switch cables: 4
Section of connecting cables: 4x 1,50 mm2
Length of connecting cables: 0,5 m
Ambient temperature range: from -20 to +45 oC
Operating position: vertically, cable down
Mounting: 2x stretcher 5x(3x30)
Protection level of casing: IP65 (EN 60529)
Protective class: II
Overvoltage category: II
Pollution degree: 2
Rated impulse withstand voltage: 1 kV (EN 61000-4-5)
Dimensions: 69x56x27 mm
Weight: 104 g
Reference standards: EN 60669-1
EN 60669-2-1
EN 61000-4-2,3,4,5,6,11
ی Itallowstoswitchonand/orswitchoff
lighting devices according to the pre-
set ambient light level,
ی adjustmentoftheswitchonthreshold,
ی wide setting scope of the switch on
threshold (from 0 to 200 lx),
ی innerlightingsensor,
ی resistanttomomentarychangesoflu-
minousuxdensity,
ی hysteresis of the switch-over thres-
hold,
ی hermetic(IP65protectiondegree)en-
closure,
ی voltagerelayoutputmax16Acapaci-
ty.
The twilight switch WZH-01 is used
to control lighting devices and other
energy receivers depending on luminous
flux density. The system switches on the
lighting at dusk and switches off at dawn.
The switching on threshold can be adju-
sted by the user. The system is resistant
to momentary changes of luminous flux
density and the same guarantees its relia-
bility. The hermetic casing (IP65) secures
the device functioning in unfavorable we-
ather conditions.
Zakład Mechaniki i Elektroniki
ZAMEL sp.j.
J.W.Dzida,K.Łodzińska
Zielona 27, 43-200 Pszczyna, Poland
Tel. +48 (32) 210 46 65, Fax +48 (32) 210 80 04
www.zamel.pl, e-mail: [email protected]
The device is designed
for one-phase installa-
tion and must be instal-
led in accordance with
standards valid in a par-
ticular country. The devi-
ce should be connected
according to the details included in this
operating manual. Installation, connection
and control should be carried out by a qua-
liedelectricianstaff,whoactinaccordan-
ce with the service manual and the device
functions. Disassembling of the device is
equal with a loss of guarantee and can
cause electric shock. Before installation
make sure the connection cables are not
under voltage. The cruciform head screw-
driver 3,5 mm should be used to instal
the device. Improper transport, storage,
anduseofthedeviceinuenceitswrong
functioning. It is not advisable to instal the
device in the following cases: if any device
part is missing or the device is damaged or
deformed. In case of improper functioning
of the device contact the producer.
CAUTION
b
l
a
c
k
b
l
u
e
g
r
e
y
b
r
o
w
n
Power supply cable (L)
Power supply cable (N)
Output (load) cable (N)
Output (load) cable (L)
Inner lighting sensor
Adjustment of the switch on threshold
CONNECTING DIAGRAM
EXAMPLE OF INSTALLATION
ver. 0.4.1 _ 2006.06.27_14:00
FUNCTIONING
The system works properly after swit-
ching on the power supply from the mains.
Turning the potentiometer in the direction
of “ “ causes the lighting device to switch
on at lower lighting level, in the direction of
“☼“causesthedevicetoswitchonathigher
lighting level. In case the inner sensor’s lumi-
nous flux density falls below the preset thres-
hold the system switches on the output relay
and its lighting devices. The relay is switched
on until the luminous flux density is over the
preset threshold. Using the luminous flux
density hysteresis (delta) and relay switching
off time delay (T) makes the system resistant
to momentary and accidental light pulses.
While mounting the twilight switch pay atten-
tion the switched on lighting does not disturb
the functioning of the twilight lighting sensor.
DIMENSIONS
INNER DIAGRAM
TIME COURSE PRODUCT FAMILY
The twilight switch WZH-01 belongs to the
twilight switches WZx family.
MOUNTING
1. Disconnect the power supply from the ma-
ins by the phase fuse, the circuit-breaker or
the switch-disconnector that are joined to the
proper circuit.
2. Check if there is no voltage on connec-
tion cables by means of a special measu-
re equipment.
3. Fasten the WZH-01 to the base with the
screw.
4. Connect the cables WZH-01 with the her-
metic installation junction box according to
installing diagram.
5. Switch on the power supply from the mains.
6. Take out the rubber hole plug covering the
adjustment of the switch on threshold poten-
tiometer.
7. Adjust the demanded switch on threshold.
8. Put back the rubber hole plug covering the
potentiometer.
Typical application:
The twilight switch operates the light control functions (for example garden
lighting). The device should be installed in a place which is not directly illuminated
by lights that are operated by this twilight switch.
RELAY CAPACITY
WZx - xx (/ S1)
Version:
01 - one range
02 - two ranges (only
type M casing)
Type of casing:
M - monomodular
N - surface mounting
H - hermetic
S - special
Symbol
Probe SOH-01
brown
grey
black blue
b
l
a
c
k
b
l
u
e
g
r
e
y
b
r
o
w
n
b
l
a
c
k
b
l
u
e
g
r
e
y
b
r
o
w
n
luminousux
density
200 lx 35 lx 20 lx 2 lx
position of
potentiometer 0 lx 200 lx
☼
0 lx 200 lx
☼
0 lx 200 lx
☼
0 lx 200 lx
☼
t
☼☼
t
∆
L, N
lx
T
t
∆≈5÷60lx T≈30s