APPEARANCE
The device is designed for
one-phase installation and
must be installed in accor-
dance with standards valid
in a particular country. The
device should be connected
according to the details inclu-
ded in this instruction manual. Installation, con-
nection and control should be carried out by a
qualied electrician staff, who act in accordan-
ce with the instruction manual and the device
functions. Disassembling of the device is equal
with a loss of guarantee and can cause elec-
tric shock. Before installation make sure the
connection cables are not under voltage. The
cruciform head screwdriver 3,5 mm should be
used to install the device. Improper transport,
storage, and use of the device inuence its
wrong functioning. It is not advisable to install
the device in the following cases: if any device’s
part is missing or the device is damaged or de-
formed. In case of improper functioning of the
device contact the producer.
CAUTION
FEATURES
TECHNICAL DATA
DESCRIPTION
ASM-03
Input (supply) terminals: L, N
Input rated voltage: 230 V AC
Input voltage tolerance: -15 ÷ +10 %
Power/relay supply indicator: green LED
Nominal frequency: 50 / 60 Hz
Rated power consumption: 25 mA
Supply/release terminals: IN, IN, IN
Supply/release control current: 300 µA
Threshold adjustment time: 3 min ÷ 30 min (rotating potentionometer)
Operation mode: ON, AUTO, OFF
Time accuracy adjustment: ±10 %
Time repeatability adjustment: ±5 %
Relay indicator: LED red
Output contacts parameters: 1NO - 16 A / 250 V AC1 4000 VA
Number of terminal clamps: 8
Section of connecting cables: 0,2 ÷ 2,50 mm2
Ambient temperature range: -20 ÷ +45 oC
Operating position: free
Mounting: TH rail 35 (EN 60715)
Casing protection degree: IP20 (EN 60529)
Protection level: II
Overvoltage category: II
Pollution degree: 2
Surge voltage: 2 kV (EN 60669-1), 1 kV (EN 61000-4-5)
Dimensions: monomodular (17,5 mm) 90x17,5x66 mm
Weight: 76 g
Reference standards: EN 60669-1; EN 60669-2-1
EN 61000-4-2,3,4,5,6,11
● Staircase lighting control
● Fluent operating time adjustment
from 3 to 30 minutes
● Relay indicator: LED red
● Input rated indicator : LED green
● Mode setting option: continuous work
mode (ON), or continuous work mode
OFF
● Cooperation with unipolar illuminated
pushbuttons
● Con-blockade function
● Voltage relay output – one joint of
max 16 A load
● Monomodular casing
● Mounting on TH 35 rail
Staircase lighting timer ASM-03 is
used for staircase and hall lightning
controlling. After a signal it switches on
the lightning for a set time and then au-
tomatically switches off. Working can be
smoothly regulated from 3 to 30 min by
potentionometer placed on front panel of
the automat. ASM-03 is equipped with
con-blockade function and ON/OFF
function.
Output relay
Switch on adjustment
Input rated signalization
Input terminal (L) Input terminal (N)
Relay indicator signalization
ON/AUTO/OFF function
Output terminals (IN,IN,IN)
terminals (11,11,14)
The symbol stands for selective
collection of electrical and
electronic devices. Placing used
devices with other waste is not
allowed
VER. 001_03.04.2012
WYMIARY OBUDOWY
TIME COURSE
RELAY CAPACITY
INNER DIAGRAM
PRODUCT FAMILY
The staircase lightning timer ASM-03 belongs
to the ASx staircase lightning timer’s family
CONNECTINGMOUNTING, FUNCTIONING
1. Disconnect the power supply from the
mains by: the phase fuse, the circuit-bre-
aker or the switch disconnector that are
joined to the proper circuit,
2. By means of special equipment check
if there is no voltage on the connec-
tion cables
3. Install ASM-03 in the switchboard on the
TH-35 rail
4. Connect the cables to the terminals ac-
cording to the installing diagram
5. Switch on the power supply from the ma-
ins
6. By means of potentionometer set requ-
ired lightning time switch on
The device is ready to operate after
proper connection. Switching on by unipo-
lar pushbutton switches on the lightning for
the time set by the user. After set time the
lightning is switched off automatically. The
staircase lightning controller enables four
wire installation. ASM-03 staircase control-
ler is equipped with con-blockade, it means
that the lightning will be switched off after a
set time in case of release button blockade.
The device can work in AUTO mode and by
means of a switch it can be switched in ON
mode (helpful in activities like cleaning) or
OFF mode (helpful by activities connected
with lightning exchange)
EXAMPLE OF INSTALATION
NL
11
11
14
IN
IN
IN
t
t
t t t
t
t
Typical application:
Staircase lightning timer which controls staircase lighting operates in four wire con-
guration. Unipolar buttons (eg. equipped with illumination) can be joined pararelly
Symbol
Version:
M - modular
N - surface
H - hermetic
P - ush junction box
Version:
01 - Three or four wire installation
02 - Con-blockade function
03 - Con-blockade and ON/AUTO/
OFF function
10 - con-blockade, smooth dyeing,
and off signalization functions
Power supply version:
24V - 24 V AC/DC available for
ASM-02
U - 12÷240 V AC/DC available for
ASH-01, ASM-01, ASN-01
GUARANTEE CARD
There is 24 months guarantee on the product
1. ZAMEL provides a two-year warranty for its products.
2. The ZAMEL warranty does not cover:
a) mechanical defects resulting from transport, loading / unloading or other circumstances
b) defects resulting from incorrect installation or operation of ZAMEL products;
c) defects resulting from any changes made by CUSTOMERS or third parties, to products sold or equipment necessary for the cor-
rect operation of products sold;
d) defects resulting from force majeure or other aleatory events for which ZAMEL is not liable;
e) power supply (batteries) to be equipped with a device in the moment of sale (if they appear);
3. All complaints in relation to the warranty must be provided by the CUSTOMER in writing to the retailer after discovering a defect.;
4. ZAMEL will review complaints in accordance with existing regulations.;
5. The way a complaint is settled, e.g. replacement of the product, repair or refund, is left to the discretion of ZAMEL.
6. Guarantee does not exclude, does not limit, nor does it suspend the rights of the PURCHASER resulting from the discrepancy
between the goods and the contract.
Salesman stamp and signature, date of sale

Other Zamel Timer manuals

Zamel EXTA ASH-02 User manual

Zamel

Zamel EXTA ASH-02 User manual

Zamel exta ZCM-32 User manual

Zamel

Zamel exta ZCM-32 User manual

Zamel EXTA ASN-02 User manual

Zamel

Zamel EXTA ASN-02 User manual

Zamel ASM-04 User manual

Zamel

Zamel ASM-04 User manual

Zamel EXTA ASM-02 User manual

Zamel

Zamel EXTA ASM-02 User manual

Zamel EXTA ASP-01 User manual

Zamel

Zamel EXTA ASP-01 User manual

Zamel EXTA ASH-01 User manual

Zamel

Zamel EXTA ASH-01 User manual

Zamel exta ASP - 10 User manual

Zamel

Zamel exta ASP - 10 User manual

Zamel EXTA ASH-01 User manual

Zamel

Zamel EXTA ASH-01 User manual

Zamel EXTA ASH-02 User manual

Zamel

Zamel EXTA ASH-02 User manual

Zamel exta ZCM-12 User manual

Zamel

Zamel exta ZCM-12 User manual

Popular Timer manuals by other brands

Full Gauge ICEMATIC manual

Full Gauge

Full Gauge ICEMATIC manual

GE 15163 quick start guide

GE

GE 15163 quick start guide

Clas Ohlson 34-2360-1 instruction manual

Clas Ohlson

Clas Ohlson 34-2360-1 instruction manual

Sibel 0090044 manual

Sibel

Sibel 0090044 manual

Hudora 65601 Instructions for use

Hudora

Hudora 65601 Instructions for use

ENFORCER SA-027WQ installation manual

ENFORCER

ENFORCER SA-027WQ installation manual

Orbit 94874 user manual

Orbit

Orbit 94874 user manual

Mercury TMR-4 user manual

Mercury

Mercury TMR-4 user manual

Anly APT-8S user manual

Anly

Anly APT-8S user manual

Danfoss TS715 Si Installation & user's instructions

Danfoss

Danfoss TS715 Si Installation & user's instructions

hager EG203E User instructions

hager

hager EG203E User instructions

Magikist MagikTimer Plus instructions

Magikist

Magikist MagikTimer Plus instructions

ADE TD 1902 operating manual

ADE

ADE TD 1902 operating manual

Green TMR-234 instruction manual

Green

Green TMR-234 instruction manual

Ancona PATIM-01 instruction sheet

Ancona

Ancona PATIM-01 instruction sheet

TFA 38.2026 instruction manual

TFA

TFA 38.2026 instruction manual

Eurochron EDT 8001 operating instructions

Eurochron

Eurochron EDT 8001 operating instructions

digi-tech GHIBLI Quick user guide

digi-tech

digi-tech GHIBLI Quick user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.