manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Zamel
  6. •
  7. Timer
  8. •
  9. Zamel EXTA ASH-01 User manual

Zamel EXTA ASH-01 User manual

Other Zamel Timer manuals

Zamel EXTA ASH-02 User manual

Zamel

Zamel EXTA ASH-02 User manual

Zamel exta ZCM-32 User manual

Zamel

Zamel exta ZCM-32 User manual

Zamel EXTA ASM-03 User manual

Zamel

Zamel EXTA ASM-03 User manual

Zamel ASM-04 User manual

Zamel

Zamel ASM-04 User manual

Zamel EXTA ASN-02 User manual

Zamel

Zamel EXTA ASN-02 User manual

Zamel EXTA ASP-01 User manual

Zamel

Zamel EXTA ASP-01 User manual

Zamel exta ZCM-12 User manual

Zamel

Zamel exta ZCM-12 User manual

Zamel EXTA ASM-02 User manual

Zamel

Zamel EXTA ASM-02 User manual

Zamel exta ASP - 10 User manual

Zamel

Zamel exta ASP - 10 User manual

Zamel EXTA ASH-02 User manual

Zamel

Zamel EXTA ASH-02 User manual

Zamel EXTA ASH-01 User manual

Zamel

Zamel EXTA ASH-01 User manual

Popular Timer manuals by other brands

SATO TM-29 instruction manual

SATO

SATO TM-29 instruction manual

Full Gauge Controls ICEMATIC quick start guide

Full Gauge Controls

Full Gauge Controls ICEMATIC quick start guide

CEI Ultrak T-3 instructions

CEI

CEI Ultrak T-3 instructions

Raindrip R675CT Installation & programming

Raindrip

Raindrip R675CT Installation & programming

Intermatic P1131 owner's manual

Intermatic

Intermatic P1131 owner's manual

Profile 010200280 instruction manual

Profile

Profile 010200280 instruction manual

Gizmo T4 instructions

Gizmo

Gizmo T4 instructions

Tekmar Timer 031 Data brochure

Tekmar

Tekmar Timer 031 Data brochure

Daikin DST301B61 Operation manual

Daikin

Daikin DST301B61 Operation manual

sisel ENDA ETM2432 manual

sisel

sisel ENDA ETM2432 manual

B&Q TE103 Installation and use instructions

B&Q

B&Q TE103 Installation and use instructions

Hozelock AC Plus 2700 instructions

Hozelock

Hozelock AC Plus 2700 instructions

GIC Eliro V7DDSS3Eliro V7DFTS3 user manual

GIC

GIC Eliro V7DDSS3Eliro V7DFTS3 user manual

Emos EMT400F quick start guide

Emos

Emos EMT400F quick start guide

FarmTek Polaris operating instructions

FarmTek

FarmTek Polaris operating instructions

Citizen ME2 series instruction manual

Citizen

Citizen ME2 series instruction manual

Primex OneVue Sync B100 install guide

Primex

Primex OneVue Sync B100 install guide

Rain Bird Optima PRT-4 owner's manual

Rain Bird

Rain Bird Optima PRT-4 owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

STAIRCASE LIGHTING TIMERY ASH-01 INSTRUCTION MANUAL
ZAMEL sp. z o.o.
ul. Zielona 27, 43-200 Pszczyna, Poland
Tel. +48 (32) 210 46 65, Fax +48 (32) 210 80 04
www.zamelcet.com, e-mail: [email protected]
VER. 002_01.12.2008
FEATURES
DESCRIPTION
APPEARANCE
ی Staircaselightingcontrol,
ی operating time adjustment from 10
sec to 10 min,
ی cooperation with monostable push-
buttons equipped with illumination
lamps,
ی cooperationwith3-wireor4-wirein-
stallation,
ی cableconnection0,5mlong,
ی hermeticcasing(IP65),
ی voltagerelayoutputmax16Acapa-
city.
The staircase lighting time delay
switchASH-01isusedtocontrollighting
devicesonstaircasesandcorridors.After
releasing the system it switches on the
lighting for the preset time by the user.
After that it switches off automatically.
Theoperatingtimecanbeadjustedfrom
10secto10minbymeansofapotentio-
meter.The staircase lighting time delay
switchASH-01canbeusedasstandard
time delay relay. The hermetic casing
(IP65)securesthedevicefunctioningin
unfavorableweatherconditions.
Thedeviceisdesigned
for single-phase instal-
lation and must be in-
stalled in accordance
with standards valid in
aparticularcountry.The
device should be con-
nectedaccordingtothedetailsincluded
in this operating manual. Installation,
connectionandcontrolshould be car-
riedoutbyaqualiedelectricianstaff,
who act in accordance with the servi-
ce manual and the device functions.
Disassembling of the device is equal
withalossofguaranteeandcancause
electricshock.Beforeinstallationmake
suretheconnectioncablesarenotun-
dervoltage.Thecruciformheadscrew-
driver3,5mmshouldbeusedtoinstal
the device. Improper transport, stora-
ge,anduseofthedeviceinuenceits
wrongfunctioning.Itisnotadvisableto
instalthedeviceinthefollowingcases:
ifanydevicepartismissingorthede-
viceisdamagedordeformed.Incase
of improper functioning of the device
contacttheproducer.
CAUTION
TECHNICAL PARAMETERS
ASH-01
Powersupplycables: L(black),N(blue)
Inputratedvoltage: 230 V~
Inputvoltagetolerance: from-15to+10%
Nominalfrequency: 50 / 60 Hz
Ratedpowerconsumption: 48 mA
Release/output(load)cables:
brown,grey(connectedinside)
Timeadjustmentrange: from10secto10min
Timeaccuracyadjustment: ±10%
Timerepeatabilityadjustment: ±5%
Timeadjustment: rotational potentiometer
Output relay parameters: 16 A / 250 V AC1 4000 VA
Numberofswitchcables: 4
Sectionofconnectingcables: 4 x 1,50 mm2
Connectingcablelength: 0,5 m
Ambienttemperaturerange: from-20to+45oC
Operating position: vertical,pointeddown
Mounting: 2xstretcher5x(3x30)
Protection degree: IP65 (PN-EN 60529)
Protectiveclass: II
Overvoltagecategory: II
Pollution degree: 2
Ratedimpulsewithstandvoltage: 1 kV (PN-EN 61000-4-5)
Dimensions: 69 x 56 x 27 mm
Weight: 101 g
Referencestandards: PN-EN 60669-1
PN-EN 60669-2-1
PN-EN 61000-4-2,3,4,5,6,11
b
l
a
c
k
b
r
o
w
n
g
r
e
y
b
l
u
e
Powersupplycable(N)
Powersupplycable(L)
Timeadjustment
Release / output (load)
cables
VER. 002_01.12.2008
INNER DIAGRAM
CONNECTINGMOUNTING
FUNCTIONING
EXAMPLE OF INSTALLATION
Afterpropermounting andinstallation
thedeviceisreadytowork.Releasingthe
system with the monostable pushbutton
causes the lighting to switch on for the
preset time.After the preset time is over
thelightingisautomaticallyswitchedofftill
its another release. The staircase lighting
timedelayswitchcooperateswith3-wireor
4-wiresystem.Whilemountingthedevice
payattentionthereleaseandloadsystems
areproperlyconnected,otherwisethede-
vicecanbeirreparablydamaged.Because
ofnoanti-blockingsystemthelightiscon-
stantlyswitchedonincasesthepushbut-
tonisblocked.
1.Disconnect the power supply from the
mainsby the phase fuse,the circuitbre-
aker or the switch-disconnector that are
joinedtothepropercircuit.
2. Check if there is no voltage on con-
nection cables by means of a special
measure equipment.
3.Fasten theASH-01 to the base with the
screw.
NOTICE! It is forbidden to bore tting
holes in the cover! It may result in the
loss of containment of the cover and
by this – the loss of guarantee!
4.ConnectthecablesASH-01withtheher-
metic installation junction box according
to installing diagram.
5.Switchonthepowersupplyfromthema-
ins.
6.Take out the rubber hole plug covering
theadjustmentoftheswitchonthreshold
potentiometer.
7.Adjust the demanded switch on time by
meansofapotentiometer.
8.Put back the rubber hole plug covering
thepotentiometer.
DIMENSIONS TIME COURSE PRODUCT FAMILY
Typical application:
ThestaircaselightingtimedelayswitchASH-01operatingthestaircaselighting
worksin3-wireinstallation.Monostablepushbutton(equippedwithillumination)can
beconnectedparallely.
RELAY CAPACITY
TheASH-01isamemberoftheASx
staircasetimerfamily.
blackblue
grey
brown
t
t t t
t
3wiresystem 4wiresystem
b
l
a
c
k
b
l
a
c
k
b
l
u
e
b
l
u
e
g
r
e
y
g
r
e
y
b
r
o
w
n
b
r
o
w
n
b
l
a
c
k
b
l
u
e
g
r
e
y
b
r
o
w
n
Device
version
Casingversion:
M - modular
N- surface
H- hermetic
P- ushjunctionboxØ60mm
Deviceversion:
01- 3-or4-wireinstallation
02- anti-blockingfunction
03- anti-blockingfunctionandON/
AUTO/OFFmodeswitch
10- uentlightingbrighteningand
dimming
Voltageversion:
24V - 24 V AC/DC available for
ASM-02
U - 12÷240 V AC/DC available for
ASH-01, ASM-01, ASN-01