ZKTeco InBio460 Guide

12
Box Lock Hole
State Indicator
Thread Hole
3.Installation
Backup Battery Control Panel
Air Switch
Panel Box Appearance Panel Box Inside Get the Panel off the track
Heat
2.Components
Thread holes
Screws
4.LED Indicators and Wire Illustration
Power Supply
Temper Switch
After the following installation, fix the panel to the track first, and then install other components to original
Dissipation Hole
Control Panel
Control Panel
Panel Track
Panel Track
2
2
1
1
3) Install other components
2) Fix the box
1) Get through the thread hole
positions.
1) Meaning of LED indicators:
LINK indicator (green): Constant light indicates TCP/IP communication is normal;
ACT indicator (yellow): Flashing indicates data is in transmitting through TCP/IP communication.
EXT RS485 indicator (yellow&green): Flashing indicates it is sending or receiving data through RS485 communication.
PC RS485 indicator (yellow&green): Flashing indicates it is sending or receiving data through RS485 communication.
POWER indicator (red): Light always indicates the control panel is power on.
RUN indicator (green): Flashing indicates that system works normally.
CARD indicator (yellow): Flashing indicates a card is punched on reader.
2) Recommended use of wires:
3) The auxiliary input may be connected to infrared body detectors, alarm switches, etc.
4 The auxiliary output may be connected to door bells, alarms, etc.)
5) State Indicators are connected to the panel box, with is power indicator, run status indicator and communication status indicator.
Interface Wire Specification Network cable Maximum length
Power (A) 18AWG*2PIN / 1.5M
Wiegand (B)
24AWG*6PIN
(6PIN, 8PIN, 10PIN for different
readers)
CAT-5 or above network cable, one
way DC impedance is less than 100Ω
/KM
100M
Electric Lock (C)
18AWG*2PIN+24AWG*2PIN,
18AWG*2PIN for lock connection,
24AWG*2PIN for door sensor
connection.
/ 50M
Button (D) 24AWG*2PIN / 100M
EXT485 (E)
20AWG*2PIN+24AWG*2PIN ,
20AWG*2PIN for reader power
supply, 24AWG*2PIN for RS485
communication
CAT-5 or above network cable, one
way DC impedance is less than 100Ω
/KM. In wire connection, +12V and
GND of power supply need to be
parallel and use double wires.
Share power with control panel: 100M
Use independence power supply
(connect RS485 signal interface only):
1000M
InBio460 Installation and Connection Guide
Version: 1.3 Date: Nov., 2015
1.Cautions
Please note the following cautions. Mis-operation may lead to personal injury or
equipment failure:
1)Do not energize the system before installation is complete; never carry out
installation activities when the system is energized.
2)All peripheral devices must be grounded.
3)The conduits of wires under relay must be matched with metaled conduits, other wires
can use PVC conduits.
4)It is strongly recommended that the length of exposed part of any connection cable
should not be longer than 4 mm. Professional clamping tools may be used to avoid
unintentional contact of exposed wires to avoid short-circuit or communication failure.
5)It is recommended that card readers and buttons be installed at height of 1.4m-1.5m
above ground.
6)It is recommended to use the power supply for control panel, and external power
supply for each lock.
7)The appliance shall be installed and wired in accordance with national electrical
code and by qualified personnel only.
Description of normal working state:
Connect the system to the power supply. If the system works properly, the POWER
indicator (red) is lit constantly and the RUN indicator (green) flashes.
Valve regulated lead-acid battery:
Constant voltage charge voltage regulation
Cycle use : 14.5V~14.9V(25)
Initial current: less than 2.88A
Standby use: 13.6V~13.8V(25)
Capacity: 12V, 7.2Ah/20hr,
Battery Type: LC-RA127R2T1
Caution:
Do not charge in a gas tight container.
Do not short the battery terminals.
Do not incinerate
Flush with water at once if contact is made with
electrolyte (Acid)
Do not attempt to disassemble the battery.
34
6.Lock Connection
5.DIP Switch Settings
1)Switches 1-6 are used to set the control panel number in RS485 communication: It is adopted binary coding and
address number should not be repeated in the network.
2) Number 7 switch is used to restore factory defaults: Switch it for three times within 10 seconds and restart the
3) Number 8 switch is used to set terminal resistance in RS485 communication: Switch it to“ON” status, For adding a
4) When electrical lock is connected with access control system, you need to parallel a FR107 diode (equipped in
1) The control panel provides lock control output interfaces. For NO lock, it is normal open when power is on, so
2) The control pa nel support s “dry mode” and “wet mode ” by using the jumper. F or “wet mode”, short 2-3 a nd
little endian, the address number setting by placing these 6 switches as shown in the figure below. Before setting
For example: Set the device number as 39 (39=1+2+4+32), the switches status are 111001, that is set number 1, 2,
COM and NO terminals should be used. For NC lock, it is normal closed when power is on, so COM and NC
in the package) to prevent the self-inductance EMF affecting the system, do not reverse the polarities.
terminal resistance of 120 ohm between 485+ and 485-.
device then all data will be cleared and the system restored factory default setting.
the address , please keep the system powered off. Place the corresponding switches to the desired status, and the
3 and 6 switches at “ON”.
terminals should be used.
4-5 terminal s. The control p anel and th e lock use sepa rate power supplies: O ne is connected with +12 V and
GND of POWER int erface (for the contro l panel), the other is con nected with V+ a nd V- of LOCK interf ace
(for the lock) . For detailed setting s for “dry mode” and “wet mo de” , please refer to the In stallation Guide.
The factory def ault is dry mod e.
STATE
PWR
EXT
RS485
PC
RS485
SWITCH
1
2
4
8
16
32
Rest or e Fa cto ry S et tings
RS48 5 Term in al Re si st ance
1 2 3 4
O
5 6 7 8
N
3) For the Wiegand read er and the InBio reader, the s tandard pow er supply is 12V/3A. So we do not recomm end
that lock and th e control panel share a co mmon power supply. If it is nec essary to do so we suggest u sing a
larg er one such as 12V/5A.No t including the power re serve, there are 2A cu rrent for the lock. For the common
electrical lock (the st andby curre nt is 300mA, the max curre nt is 500mA), the maximu m connected lock is 4.
STATE
PWR
EXT
RS4 85
PC
RS4 85
SWI TCH
D
AUX Input 1
D
AUX Input 2
D
AUX Input 3
D
AUX Input 4
E
RS485
Reader
State Indicator
D
Exit Button for
Lock 1
B
Reader for
Lock 1
D
Exit Button for
Lock 2
B
Reader for
Lock 2
D
Exit Button for
Lock 3
B
Reader for
Lock 3
D
Exit Button for
Lock 4
B
Reader for
Lock 4
Power Input
A
ALock Power Inpu t
LINK
PC Network
Interface
ACT
DIP Switch
RS485
Converter
PC
DAUX Output 1
DAUX Output 2
DAUX Output 3
DAUX Output 4
CLock 1
CLock 2
CLock 3
CLock 4
SD Card Interfa ce.
Function :
Backup Access
Control Logs
AUX Input (1-4) connect to the infrared human
body induction, wireless exit button, windows
sensor with dry contact (no voltage).
AUX Input (1-4) connect way is same.
Note:
Output Electrical Parameters:
Rated Voltage: 12V(DC)
Rated Current: 0.5A
5
1
AUX Output (1-4) connect to alarm, door bell and so on;
Port (NO, COM, NC) Electrical Parameters:
MAX Voltage: 36V(DC) MAX Current: 1.25A
Note:
AUX Output (1-4) connect way is same.
Lock (1-4):
Port (SEN)connect to door sensor single with
dry contact (no voltage);
Port (NO, COM, NC) Electrical Parameters:
MAX Voltage: 36V(DC) MAX Current: 2A
Note:
When you select Wet mode, the power is Lock power,
Lock (1-4) total load don’t more than Lock power Rated
current (2A).
Lock (1-4) connect way is same.
2
Lock Power Input Electrical Parameters:
Rated Voltage: 36V(DC) Rated Current: 2A
Device Power Input Electrical Parameters:
Rated Voltage: 12V(DC) Rated Current: 2A
34
Exit button for Lock (1-4) connect to Exit button with dry contact.(no voltage);
Reader (1-4) connect to WG Reader;
Port (+12V)Output Electrical Parameters:
Rated Voltage: 12V(DC) Rated Current: 0.5A
Port (BEEP GLED) Output Electrical Parameters:
Rated Voltage: 5V(DC) Raged Current: 0.5mA
7
6
5
1
2
3
4
7
6
1
1
1
2
2
2
5
5
5
6
6
6
7
7
7
65
8.Equipment Communication
1. TCP/IP Communication
2. RS485 Communication
The PC software can communicate with the panel according to the communication protocols (RS485 and TCP/IP) for data
exchange and remote management. The communication cable should be as far away from high-voltage lines as possible.
Do not keep the communication cable in parallel with power cords or bind them together.
1) Internationally accepted RVVP (shielded twisted-pair) wires should be used for communication to ef fectively avoid
interference. RS485 communication wires should be connected by means of bus cascade connection.
The followin g is “wet mode” lock conne ction with external po wer supply .
Stick the screw driver to the rectangular hole on the four corner of the panel back, push it from outside to inside.
After hearing the "click" sound, you can remove the case from the panel.
7.485 Reader (InBio Reader) Connection
+
+
+
-
-
NC
NO
GND
COM
SEN
+
+
-
-
FR1 07
-
LED
1
2
3
4
5
NO Lock
LOCK
LOCK
Enlarged dia gr am
of lock terminal s
NC Lock
Lock Power
Diode
Diode
Jumper
terminal
FR1 07
+12V
GND
#3 Reader
+12V
GND
485-
GND
485+
#1 Reader #2 R ead er#8 Reader
...
(Separate power supplies) (Separate power supplies)
PC
STATE
PWR
EXT
RS485
PC
RS485
SWITCH
PC
485 +
485-
GND
485 + 485+ 485+
485 - 48 5- 4 85 -
GND G ND G ND
seria l line
48 5
Conv erter
DIP Sw itch
8# Cont rol Panel
2# Cont rol Panel
1# Cont rol Panel
1 2 3 4
O
5 6 7 8
N
STATE
PWR
EXT
RS485
PC
RS485
SWITCH
STATE
PWR
EXT
RS485
PC
RS485
SWITCH
STATE
PWR
EXT
RS485
PC
RS485
SWITCH
1# Control Panel 2# Control Panel
STATE
PWR
EXT
RS485
PC
RS485
SWITCH
STATE
PWR
EXT
RS485
PC
RS485
SWITCH
PC
Switch
n8 Control Panel
STATE
PWR
EXT
RS485
PC
RS485
SWITCH
5
The control panel supports InBio biometric verification reader and Wiegand reader. All InBio reader operations are executed
For reader 1, 2 (the odd number is for entered reader, and the even number is for exit reader), the door number is 1. And the
485 address is 1, 2, as in the figure below. For more information, please refer to the software user manual.
from the control panel including storage, verification, etc. Re-register the fingerprints is not required when replacing the reader.
For example, use the FR1200 reader , the standby current is less than 100mA, the max current is less than 120mA, When
using the separately power supplies, to make sure the steady operation.
Besides, a single EXT485 interface can supply maximum 500m A(1 2V) current . S o the entire cuttent consumption
should be less than this max value when the readers share power with the panel.
In calculation, please use max current of the reader, and start current is usually more than twice of the
normal work current, please consider of this situation. 3) One RS485 bus may hold 63 control panels, but it is recommended to connect with less than 32 access control panels.
4) For the InBio reader connection, if the reader and the control panel use the same power, it is recommended that the wire
5) To enhance the stability of communication When the wire is longer than 300 meters, it is necessary to keep
2) It is recommended that the RS485 bus should be less than 600 meters to aid communication stability.
(120 ohm) of the two devices to the system. As shown in the figure above, turn number 8 of the DIP switches of
number 8 switch of the first and the last control panel at “ON” status. That adds the RS485 terminal resistance
should be less than 100 meters. If greater length is required, please use a separate power supply.
the 1# and 8# at “ON” status.
InBio reader connection: First of all, set the 485 address (device number) of the reader by DIP switch and software.
Attention: DIP switch configuration for FR1200, KR500E&M-RS; Software configuration for unnormalized F11,MA300 and other fingerprint readers.
the device is start, Instantaneous current can reach 240 mA. As InBio reader, consider the starting current is
bigger,through the EXT485 interface can only connect two readers for power supply. So the power of control
panel connect only nearest 2 readers. For some of the devices with much greater consumption, we suggest to

Other ZKTeco Control System manuals

ZKTeco X7 User manual

ZKTeco

ZKTeco X7 User manual

ZKTeco CMP-200 Series User manual

ZKTeco

ZKTeco CMP-200 Series User manual

ZKTeco QR500 Operating instructions

ZKTeco

ZKTeco QR500 Operating instructions

ZKTeco PB4060 User manual

ZKTeco

ZKTeco PB4060 User manual

ZKTeco SBTL5000 series User manual

ZKTeco

ZKTeco SBTL5000 series User manual

ZKTeco BG2000 Series User manual

ZKTeco

ZKTeco BG2000 Series User manual

ZKTeco BG1000 Series User manual

ZKTeco

ZKTeco BG1000 Series User manual

ZKTeco CMP-100A User manual

ZKTeco

ZKTeco CMP-100A User manual

Popular Control System manuals by other brands

JUMO variTRON 300 operating manual

JUMO

JUMO variTRON 300 operating manual

Hauck OVC OIL VISCOSITY CONTROL instructions

Hauck

Hauck OVC OIL VISCOSITY CONTROL instructions

Efka euramot AB60D1472 manual

Efka

Efka euramot AB60D1472 manual

Vaillant VRC 700/6 operating instructions

Vaillant

Vaillant VRC 700/6 operating instructions

K-Systems 8600C Series Installation, start-up, operation

K-Systems

K-Systems 8600C Series Installation, start-up, operation

Phason AutoFlex Connect II installation guide

Phason

Phason AutoFlex Connect II installation guide

Dometic Go Power! GP-BMG quick start guide

Dometic

Dometic Go Power! GP-BMG quick start guide

Ormazabal cgmcosmos-l General instructions

Ormazabal

Ormazabal cgmcosmos-l General instructions

2VV DAPHNE Installation

2VV

2VV DAPHNE Installation

Data Aire gPod Installation, operation & maintenance manual

Data Aire

Data Aire gPod Installation, operation & maintenance manual

MEKANIKA EVO Calibration

MEKANIKA

MEKANIKA EVO Calibration

Pilz PNOZ mmc11p operating manual

Pilz

Pilz PNOZ mmc11p operating manual

Dea 202RR Instructions and warnings

Dea

Dea 202RR Instructions and warnings

Mandik SEDM-D Installation, operation, maintenance and service manual

Mandik

Mandik SEDM-D Installation, operation, maintenance and service manual

VIPA System 200V Series manual

VIPA

VIPA System 200V Series manual

herdstar BinTrac Breeder Control installation manual

herdstar

herdstar BinTrac Breeder Control installation manual

Anticimex Smart Connect Mini user manual

Anticimex

Anticimex Smart Connect Mini user manual

Burkert 8644 AirLINE quick start

Burkert

Burkert 8644 AirLINE quick start

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.