+IMPORTANT: PLEASE READ BEFORE USING 360 SOILSCAN
+
+
+
To prevent injuries and to avoid damaging 360 SOILSCAN, please read all product safety
instructions before using 360 SOILSCAN. For detailed safety instructions, launch your 360
SOILSCAN Application, select Settings and navigate to Product Safety. In addition, before
using your 360 SOILSCAN, please read all product warranty information by launching your
360 SOILSCAN Application, selecting Settings and navigating to Legal.
This device complies with part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operation.
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is
subject to the following two conditions: (1) this device may not cause interference, and (2)
this device must accept any interference, including interference that may cause undesired
operation of the device.
360YIELDCENTER.COM

+PARTS OVERVIEW
360 SOILSCAN™
SETUP INSTRUCTIONS
1. 360 SOILSCAN Unit and Carrying Case (Carrying Case is not pictured.)
2. 12 Volt Power Cable
3. 110 Volt Power Cable
4. Lightning to USB Cable
5. 30-Pin to USB Cable
1 2
3
4
5
360YIELDCENTER.COM

+PARTS OVERVIEW (continued)
360 SOILSCAN™
SETUP INSTRUCTIONS
6. NO3-N, 7pH Standard Solution Bottle 500 mL
7. Bottle, Wash
8. NO3-N Storage Bottle
9. Reference Electrode Storage Bottle
10. Calibration Bottle - 4 Compartment
11. Soil Scoop
12. 50 Dixie® Cups - 5 Ounce
13. Mixing Sleeve
NOTE: Parts shown are not to scale.
6 7
8
12 13
9
11
10
360YIELDCENTER.COM

360 SOILSCAN SETUP INSTRUCTIONS
(ORIGINAL - ENGLISH)
Plug in power cord.
Turn on 360 SOILSCAN unit. The power
switch glows red when the unit is turned
on.
Launch the 360 SOILSCAN App on
your iPad. Ensure you have downloaded
the 360 SOILSCAN App at https://
itunes.apple.com/us/app/360-soilscan/
id956219879?mt=8 and have your iPad 3
or newer device on hand.
Select your device. Select your 360
SOILSCAN device from the menu and
follow the instructions on the screen.
Step 1
Step 2
Step 3
Step 4
Figure 1
Figure 2
Figure 3
Figure 4
360 SOILSCAN™
SETUP INSTRUCTIONS
Figure 1
Monday
9
Figure 2
Figure 3
Figure 4
+
360YIELDCENTER.COM

Docking your iPad. Your iPad can be
docked to your 360 SOILSCAN. The USB
cord provided can be used to power your
iPad. The USB cord is not required to
connect to your 360 SOILSCAN since it
communicates to your iPad wirelessly.
Step 5
+360 SOILSCAN SET UP COMPLETE
Figure 5
Figure 5
360 SOILSCAN™
SETUP INSTRUCTIONS
Supply Voltage: 12VDC, 5 A
Manufacturer: 360 Yield Center, 180 Detroit, Morton, IL 61550 U.S.A.
Machinery Designation: 360 SOILSCAN
Machinery Description: Soil Testing Device
Storage Temperature: 5 to 50 degrees C
Operating Temperature: 10 to 40 degrees C
MSDS: Go to www.360YieldCenter.com/360-soilscan/msds 360YIELDCENTER.COM
360 SOILSCAN SETUP INSTRUCTIONS
(ORIGINAL - ENGLISH) (continued)
+

360 SOILSCAN™
SETUP INSTRUCTIONS
Store the NO3-N Sensor (gray) dry. Use the
NO3-N Storage Bottle that came with the
sensor to cover the tip. Switch to this storage
method if the machine will not be used within
the next 24 hours.
Fill the small Reference Electrode Storage Bottle
¾ full with Standard Solution. Add cap to bottle
and insert over electrode (red), making sure
electrode tip is immersed in solution. Tighten
the cap on the bottle. Switch to this storage
method if the machine will not be used within
the next 24 hours.
Place the 360 SOILSCAN™ machine and sensors
in a mild environment (60°F to 80°F). Do not
leave the machine in an unheated shop as
exposure to cold temperatures can aect the
sensor performance. A good rule of thumb is to
treat the machine and sensors similar to how
you would treat your iPad.
Standard Solution can be stored at room
temperature.
Extra tips that have not been opened should
also be stored at room temperature in their
original packaging.
For winter storage, make sure the water tank on
your machine is empty and the water line
is purged.
+
+
+
+
+
+
Below are tips for storing your machine for more than 24
hours or over the winter.
Figure 6: Reference Electrode (1) (Red): Always store wet in the
Standard Solution. NO3-N Sensor (2) (Gray): Store dry.
1
2
360YIELDCENTER.COM
360 SOILSCAN
STORAGE GUIDELINES
+

Machine Measurements: 21L x 12W x 19H
Weight: 17.4 kg
Lifting/carrying: When picking up 360 SOILSCAN™, use the handle on the back of the machine.
Safety: Please read and follow all instructions prior to operating equipment. Safety may be
impaired if equipment is used in a manner not specified by the manufacturer.
Wear chemical splash safety goggles, chemical-resistant gloves, and a chemical-resistant apron
when handling standard solution.
Noise level: Noise levels emitted from the equipment are under 70dBA.
+USB PORT
360 SOILSCAN™
SETUP INSTRUCTIONS
The USB port is intended only for connection to signal circuits from SELV sources of supply such
as certified information technology equipment (i.e., computer, touch pads, cell phones, etc.).
The supply connector is intended only for connection to the output of the brick power supply
originally provided with the unit or to an accessory outlet of a vehicle through the vehicle supply
cord provided with the unit. These devices provide required protection for the equipment for
CE compliance and cannot be substituted by other, similar devices. If the supply cord or power
supply is damaged, contact the manufacturer for replacement.
Warning: Keep hands/fingers away from mix motor while in progress.
Refer to manual for power connection to the supply.
+MAINTENANCE/SERVICE
Sensor Tip Test: See attached “360 SOILSCAN Sensor Testing”.
Proper Storage: See attached “Storage Guidelines for 360 SOILSCAN”.
Power supply: Only use 360 Yield Center supplied parts for power supply. Use of unapproved
parts may result in damage to the components.
Only use 360 Yield Center parts for servicing unit. Use of unapproved parts may result in
damage to components. Regularly inspect all cords and cables. Do not use if any cable or cord is
damaged. Replace any damaged cables and cords with only manufactured specified parts.
Only operate the unit in a location where ready access to the supply connection point for
disconnection is readily accessible.
Replace fuse only as marked on fuseholder. Use only Type ABC fast acting fuses rated 5A,
125Vdc. Use of higher value fuses may result in fire hazards.
End of life disposal of equipment: Do not place in garbage bin. Take equipment to your nearest
electronics recycler for proper disposal.
360 SOILSCAN ADDITIONAL PRODUCT
INFORMATION AND INSTRUCTIONS
+
360YIELDCENTER.COM

+RANGE OF ENVIRONMENTAL CONDITIONS
360 SOILSCAN™
SETUP INSTRUCTIONS
This equipment is intended for indoor or outdoor use. (Do not operate outdoors unless conditions
are dry.)
This equipment is designed only for connection sources of supply that are below shock hazard
levels in normal and single fault conditions. Connect only to source of supply rated nominal 12V
from a vehicle electrical system or to the certified power supply provided with the unit.
Operating Temperature: 10 to 40 degrees C
Altitude: up to 5,000m
Relative humidity: up to 98%
Supply voltage fluctuations= +/-20%; overvoltage Category 1, pollution degree 3.
IP rating: IP2X
+SYMBOLS
Warning: Keep hands/fingers away from mix motor while in progress.
Refer to manual for power connection to the supply.
360 SOILSCAN ADDITIONAL PRODUCT
INFORMATION AND INSTRUCTIONS (continued)
+


All trademarks are the property of 360 Yield Center, its ailiates and/or its licensors.
iPad is a registered trademark of Apple Inc. Corporation.
©2016 360 Yield Center. All rights reserved. YCG16015
Table of contents
Other 360 YIELD CENTER Farm Equipment manuals