manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. 3M
  6. •
  7. Respiratory Product
  8. •
  9. 3M Air-Mate PAPR 231-01-30 User manual

3M Air-Mate PAPR 231-01-30 User manual

System Description
The 3M™ belt-mounted Air-Mate™ PoweredAir Purifying Respirator (PAPR) Assembly is designed to be used with certain
3M headgear,filter, battery and breathing tube to form a complete NIOSH approved respiratory system. When used in
accordance with its NIOSH approval, these systems can provide respiratory protection against certain airborne particulate
contaminants including dusts, fumes, mists,radionuclides and asbestos. The Air Mate™ does not provide protection
against vapors or gases and is not an intrinsically safe system.
3M headgear (respiratory inlet covering) includes a loose fitting head cover and hood that serves as a respiratory protective
covering for the nose and mouth area. Refer to the enclosed 3M™ Air-MateNIOSH approval label for approved system
configurations.
These systems do not contain latex.
List of Warnings and Cautions within these User Instructions
This product helps protect against certain airborne particles. Misuse may result in sickness or death. For proper
use, see supervisor, User Instructions, or call 3M in U.S.A., 1-800-243-4630.In Canada, call Technical Service at
1-800-267-4414.
Each person using this respirator must read and understand the information in these User Instructions before use. Use
of these respirators by untrained or unqualified persons, or use that is not in accordance with these User Instructions,
may adversely affect respirator performance and result in sickness or death.
Do not use with parts or accessories other than those manufactured by 3M™ as described in these User Instructions
or on the NIOSH approval label for this respirator. Do not attempt to repair or modify any component of the system
except as described in these User Instructions. Failure to do so may adversely affect respirator performance and
result in sickness or death.
Failure to conduct an inspection and complete all necessary repairs before use may adversely affect respirator
performance and result in sickness or death.
Failure to pass a user performance check and complete all necessary repairs before use may adversely affect
respirator performance and result in sickness or death.
Use of this respirator in atmospheres for which it was not NIOSH certified or designed may result in sickness or
death. Do not use this respirator where:
- Atmospheres contain hazardous vapors or gases.
- Atmospheres are oxygen deficient.
- Contaminant concentrations are unknown.
- Contaminant concentrations are Immediately Dangerous to Life or Heath (IDLH).
- Contaminant concentrations exceed the maximum use concentration (MUC) determined by using the assigned
protection factor (APF) recommended for the applicable headgear or the APF mandated by specific government
standards, whichever is lower.Refer to the User instructions provided with the applicable headgear.
Do not enter a contaminated area until properly donning the respirator system. Do not remove the respirator before
leaving the contaminated area. Doing so may result in sickness or death.
Contaminants that are dangerous to your health include those that you may not be able to see or smell. Leave the
contaminated area immediately if any of the following conditions occur. Failure to do so may result in sickness or
death.
- Airflow decreases or stops.
- Any part of the system becomes damaged.
- Airflow into the respirator decreases or stops.
- Breathing becomes difficult.
- You feel dizzy or your vision is impaired.
- You taste or smell contaminants.
- Your face,eyes, nose or mouth become(s) irritated.
- You suspect that the concentration of contaminants may have reached levels at which this respirator may no
longer provide adequate protection.
Do not expose blower/filter assembly directly to sparks or molten metal spatter. Direct contact with sparks or molten
metal spatter may damage the filter, allowing unfiltered air into the breathing zone,which may result in sickness or
death, and may cause the filter or blower housing to ignite, resulting in serious injury,sickness or death.
Do not clean respirator with solvents. Cleaning with solvents may degrade some respirator components and
reduce respirator effectiveness. Inspect all respirator components before each use to ensure proper operating
conditions. Failure to do so may result in sickness or death.
Never attempt to clean filters by knocking or blowing out accumulated material. This may result in damage to the
filter membrane allowing hazardous particles to enter the breathing zone, resulting in sickness or death.
LIMITATIONSOF USE
Do not wear this respirator system to enter areas where:
• Atmospheres are oxygen deficient.
• Contaminant concentrations are unknown.
• Contaminant concentrations are Immediately Dangerous to Life or Health (IDLH).
• Contaminant concentrations exceed the maximum use concentration (MUC) determined using the Assigned
Protection Factor (APF) for the specific respirator system or the APF mandated by specific government standards,
whichever is lower.
Refer to the User Instructions provided with the applicable headgear and the additional cautions and limitations under the
NIOSH Cautions and Limitations in this User Instructions.
RESPIRATOR PROGRAM MANAGEMENT
Occupational use of respirators must be in compliance with applicable health and safety standards. By United State
regulation employers must establish a written respirator protection program meeting the requirements of the Occupational
Safety and Health Administration (OSHA) Respiratory Protection standard 29 CFR 1910.134 and any applicable OSHA
substance specific standards. For additional information on this standard contact OSHA at www.OSHA.gov.In Canada, CSA
standard Z94.4 requirements must be met and/or requirements of the applicable jurisdiction as appropriate. The major
sections of 29 CFR 1910.134 are listed here for reference. Consult and industrial hygienist or call 3M Technical Service with
questions concerning applicability of these products to your job requirements.
Description du système
L'ensemble respirateur d'épuration d'air propulsé monté à la ceinture Air-Mate™3M™est conçu pour être utilisé avec
certaines pièces faciales, filtres, piles et tuyaux de respiration 3M homologués pour former un système de protection
respiratoire complet homologué par le NIOSH. Utilisé conformément à l'homologation du NIOSH, ce type de système
procure une protection respiratoire contre certaines particules en suspension dans l'air,notamment les poussières, les
fumées, les brouillards, les radionucléides et l'amiante.Le respirateur Air-Mate™ne protège pas contre les vapeurs et les
gaz, et il n'est pas intrinsèquement sécuritaire.
La pièce faciale 3M (dispositif qui couvre l'admission d'air) comprend un masque à ajustement lâche et une cagoule pour
former un dispositif de protection respiratoire qui couvre le nez et la bouche. Consulter l'étiquette d'homologation du NIOSH
du respirateur Air-Mate 3M™pour connaître les configurations de systèmes homologuées.
Ces systèmes ne contiennent pas de latex.
Liste des mises en garde et des avertissements énoncés dans les présentes directives d’utilisation
Ce produit protège contre certaines particules en suspension dans l'air.Une mauvaise utilisation peut provoquer
des problèmes de santé ou la mort. Pour tout renseignement sur l’utilisation adéquate de ce produit, consulter son
superviseur, lire les directives d’utilisation ou communiquer, au Canada, avec le Service technique au
1 800 267-4414.
Avant d'utiliser ce respirateur,chaque utilisa teur doit lire et comprendre les présentes directives d’utilisation.
L’utilisation de ces respirateurs par des personnes qui n’ont pas reçu la formation nécessaire ou qui n’ont pas les
qualifications requises, ou l’utilisation non conforme aux présentes directives d'utilisation peut diminuer l’efficacité du
respirateur et provoquer des problèmes de santé ou la mort.
Ne pas utiliser avec des pièces ou des accessoires autres que ceux fabriqués par 3M, conformément aux présentes
directives d’utilisation ou à l’étiquette d’homologation du NIOSH du respirateur utilisé. Ne pas tenter de réparer
ou de modifier les composants du système, sauf comme le décrivent les présentes directives d’utilisation. Tout
manquement à ces directives peut diminuer l’efficacité du respirateur et provoquer des problèmes de santé
ou la mort.
Le fait de ne pas procéder à une inspection et de ne pas effectuer toutes les réparations nécessaires avant d’utiliser le
respirateur peut diminuer l’efficacité de ce dernier et provoquer des problèmes de santé ou la mort.
Le fait de ne pas procéder à un essai de fonctionnement et de ne pas effectuer toutes les réparations nécessaires avant
d’utiliser le respirateur peut diminuer l’efficacité de ce dernier et provoquer des problèmes de santé ou la mort.
L’utilisation de ce respirateur dans des atmosphères pour lesquelles il n’a pas été conçu ou homologué par le NIOSH
peut provoquer des problèmes de santé ou la mort. Ne pas porter ce respirateur dans les situations suivantes :
- Atmosphères contenant des vapeurs ou des gaz dangereux;
- Atmosphères déficientes en oxygène;
- Atmosphères où les concentrations des contaminants sont inconnues;
- Lorsque les concentrations des contaminants sont inconnues ou présentent un danger immédiat pour la vie ou la
santé (divs);
- Atmosphères où les concentrations de contaminants sont supérieures à la concentration d'utilisation maximale
déterminée à l'aide du facteur de protection caractéristique (fpc) recommandé pour la pièce faciale applicable
ou au fpc établi par des normes gouvernementales spécifiques, selon la valeur la moins élevée. Consulter les
directives d'utilisation fournies avec la pièce faciale en question.
Ne pas pénétrer dans une zone contaminée sans s'assurer que le respirateur a été mis en place correctement. Ne pas
retirer le respirateur avant de sortir de la zone contaminée. Tout manquement à ces directives peut provoquer des
problèmes de santé ou la mort.
Les contaminants dangereux pour la santé englobent les particules trop petites pour être senties ou être visibles
à l’œil nu. Quitter immédiatement la zone contaminée si l’une ou l’autre des conditions ci-dessous survient. Tout
manquement à ces directives peut provoquer des problèmes de santé ou la mort.
- Le débit d'air diminue ou s'arrête;
- Une partie du système est endommagée;
- Le débit d’air alimentant le respirateur diminue ou s’arrête;
- La respiration devient difficile;
- On éprouve des étourdissements ou des problèmes de vision;
- On décèle un goût ou une odeur de contaminants;
- On ressent une irritation au visage, aux yeux, au nez ou à la bouche;
- On pense que la concentration des contaminants a atteint un niveau tel que le respirateur ne fournit plus une
protection adéquate.
Ne pas exposer l'ensemble souffleur et filtre directement aux étincelles ou aux projections de métal en fusion. Le
contact direct avec des étincelles ou des projections de métal en fusion peut endommager le filtre et ainsi laisser
pénétrer de l'air non filtré dans la zone de respiration de l'utilisateur, ce qui peut provoquer des problèmes de
santé ou la mort. Le filtre et le boîtier du souffleur risquent alors de s'enflammer,causant ainsi des blessures
graves, des problèmes de santé ou la mort.
Ne pas nettoyer le respirateur à l’aide de solvants. Le nettoyage du respirateur avec des solvants peut en réduire
l’efficacité et endommager certains de ses composants. Inspecter tous les composants du respirateur avant chaque
utilisation pour s’assurer qu’il est en bon état de marche. Tout manquement à ces directives peut provoquer des
problèmes de santé ou la mort.
Ne jamais essayer de nettoyer les filtres en cognant le respirateur ou en soufflant de manière à déloger les
substances accumulées. Cela peut endommager la membrane du filtre et permettre aux particules nocives de
pénétrer dans la zone de respiration de l’utilisateur, provoquant ainsi des problèmes de santé ou la mort.
RESTRICTIONS D'UTILISATION
Ne pas porter ce respirateur en présence des conditions ci-dessous.
• Atmosphères déficientes en oxygène
• Atmosphères où les concentra tions des contaminants sont inconnues.
• Atmosphères où les concentra tions des contaminants présentent un danger immédiat pour la vie ou la santé (DIVS).
• Atmosphères où les concentra tions de contaminants sont supérieures à la concentration d'utilisation maximale
déterminée à l'aide du facteur de protection caractéristique (FPC) recommandé pour le système de protection
respiratoire utilisé ou au FPC établi par des normes gouvernementales spécifiques, selon la valeur la moins élevée.
Consulter les directives d’utilisation fournies avec la pièce faciale en question ainsi que la section Avertissements et
restrictions du NIOSH à ce sujet.
GESTION DES PROGRAMMES DE PROTECTION RESPIRATOIRE
L'utilisation de respirateurs en milieu professionnel doit être conforme aux normes de santé et de sécurité applicables. La
réglementation oblige les employeurs américains à mettre sur pied un programme de protection respiratoire écrit conforme
aux exigences de la norme 29 CFR 1910.134 de l'Occupational Safety and Health Administration (OSHA) relative à la
protection respiratoire et à toutes les normes de l'OSHA applicables relatives aux substances. Pour obtenir de plus amples
renseignements au sujet de la norme 29 CFR 1910.134, communiquer avec l'OSHA à l'adresse www.OSHA.gov.Au Canada,
se conformer à la norme Z94.4 de la CSA et/ou aux exigences de l'autorité compétente de sa région, le cas échéant. Les
principales sections de la norme 29 CFR 1910.134 sont indiquées aux présentes à titre de référence. Pour toute question
sur la convenance de ces produits à son milieu de travail, consulter un hygiéniste industriel ou communiquer avec le
Service technique de 3M.
Major Sections of OSHA 29 CFR 1910.134
Section Description
A Permissible Practice
B Definitions
C Respiratory Protection Program
D Selection of Respirators
E Medical Evaluation
F Fit Testing
G Use of Respirators
H Maintenance and Care of Respirators
I Breathing Air Quality and Use
J Identification of Cartridges, Filters, and Canisters
K Training and Information
L Program Evaluation
M Recordkeeping
Each person using this respirator must read and understand the information in these User Instructions before use. Use
of these respirators by untrained or unqualified persons, or use that is not in accordance with these User Instructions,
may adversely affect respirator performance and result in sickness or death.
NIOSH – APPROVAL, CAUTIONS AND LIMITATIONS
NIOSH Approval
For a listing of the components of NIOSH approved 3M™ Air-Mate™ PAPRrespirator y systems,refer to the NIOSH approval
label included with the product or contact 3M TechnicalService at 1-800-243-4630.
NIOSH Cautions and Limitations
A – Not for use in atmospheres containing less than 19.5 percent oxygen.
B – Not for use in atmospheres immediately dangerous to life or health.
C – Do not exceed maximum use concentrations established by regulatory standards.
F – Do not use powered air-purifying respirators if airflow is less than four cfm (115 lpm) for tight fitting facepieces or six
cfm (170 lpm) for hoods and/or helmets.
I – Contains electrical parts that may cause an ignition in flammable or explosive atmospheres.
J – Failure to properly use and maintain this product could result in injury or death.
L – Follow the manufacturer’s User’s Instructions for changing cartridges,canister and/or filters.
M – All approved respirators shall be selected, fitted, used, and maintained in accordance with MSHA,OSHA, and other
applicable regulations.
N – Never substitute, modify, add, or omit parts.Use only exact replacement parts in the configuration as specified by the
manufacturer.
O – Refer to User’sInstructions, and/or maintenance manuals for information on use and maintenance of these respira tors.
P – NIOSH does not evaluate respirators for use as surgical masks.
OPERATING INSTRUCTIONS
Assembly
Breathing Tube
To connect the BE-224 or older 008-00-14 breathing tube to the PAPRunit, insert the breathing tube (male end with pins)
into the PAPR unit and twist clockwise to lock in place.To connect the breathing tube to the headgear, see the appropriate
headgear User Instructions.
Battery Pack Installation
1. Remove the back cover and the filter from the PAPR unit.
2. Insert the battery pack into its compartment and press it down to seat in place. This action will engage the battery
terminals in the socket on the side of the battery pack (Fig. 1).
3. Slide the battery pack clip under the slot on the housing to hold in place.
4. Confirm that the filter gasket is properly installed in the groove on the housing (Fig. 1).
5. Replace the filter with arrows pointing in towards the battery pack (Fig. 2).
6. Snap the back cover into place.
7. Charge the battery before use following the Battery Charging Instructions below.
Battery Charging
1. To use the 3M™ Smart Battery Charger, place the charging station horizontally on a flat surface and plug the station
AC power cord into a regulated 120v-60Hz outlet.
2. The green LED light will turn on.
3. Insert the charging lead into the socket in the side of the blower unit. Alternatively, the battery can be removed from
the blower unit and charged using the external charging adapter (part number 520-04-24) (Fig. 3).
4. The LED will turn off, indicating that the battery pack is attached and being charged in a high rate mode.
5. After approximately eight hours (depending on the amount of charging required) the LED will turn back on, indicating
that the charger has switched to a trickle rate mode. For Canada chargers, when in trickle mode,the LED light will
cycle on and off every 3 – 5 seconds.
6. The Air-Mate battery can provide up to 500 charge/discharge cycles. However,the life of the battery will be
significantly reduced when exposed to high heat over an extended period of time.
To maximize battery life, these guidelines should be followed:
– Charge 3M™ battery packs before they are completely discharged. Damage may occur if the battery pack is
completely discharged (“deep discharged”) frequently.
– 3M™ battery packs may be charged any time during the discharge cycle. Unlike some NiCd batteries, 3M™ battery
packs do not develop a “memory”. Whether it has been used 30 minutes or 8 hours,the battery pack may be charged.
– Always charge batteries at a temperature of 77°F (25ºC) or less. At higher temperatures, the battery pack may not
accept a full charge. If a battery pack feels hot, let it cool for 1/2-hour before charging.
– Batteries may be left on trickle rate mode to maintain optimum capacity for up to 30 days. Batteries should not be
stored long term connected to the charger.Without periodic charging, a NiCd battery in storage loses approximately
1% of its charge each day. Infrequently used battery packs should be fully charged,initially, then charged overnight
once per week or one hour each day to maintain a full charge. Batteries subjected to prolonged storage (longer than
6 months) may loose their capacity to hold a full charge. Battery capacity can be checked by running the PAPR motor/
blower unit for eight hours and checking that airflow is maintained at six CFM or greater. Several charge/run-down
cycles may restore battery capacity.
– For infrequently used batteries, battery capacity should be checked regularly by running the PAPR motor blower unit
and noting how long the required airflow is maintained using the air flow indicator.
– Do not charge multiple battery packs in an enclosed cabinet without ventilation.
– To properly dispose of the battery pack, follow local solid waste disposal regulations or call the RBRC Battery Recycling
Information Helpline at 1-800-8-BATTERY (1-800-822-8837).
Filter and Filter Gasket Replacement
The high efficiency (HE) filter must be changed:
– When an airflow check of the PAPR unit reveals that the airflow indicator does not rise to the specified level (with a
properly charged battery pack powering the PAPR unit);
– When the filter has been physically damaged;
– When water has entered the high efficiency filter; or
– In order to comply with local administrative procedures.
Removal of Filter and Gasket
1. Pull the belt through the belt retainers to form a loop, which is clear of the PAPR unit (Fig. 4).
2. Release the back cover's locking tabs and remove the back cover.
3. Remove and discard the high efficiency filter and filter gasket (located in the supporting groove inside the PAPR –
See Fig. 1) in accordance with local, state,and federal guidelines. Gasket can be removed using a tweezers (Fig. 5).
Gaskets must be replaced when a new filter is installed.
Replacement of Filter and Gasket
1. Inspect the new filter gasket and ensure that it is not torn or damaged before proceeding.
2. Fit the new filter gasket into the filter support groove ensuring that the gasket is flush against the sides of the PAPR
unit, leaving no gaps.
3. Fit the replacement filter into the PAPR unit with the arrows pointing into the PAPR unit (Fig. 2).
4. Snap the back cover's locking tabs into the rear of the PAPR unit.
5. Pull the belt through the belt retainers.
Installation of Waist Belts
021-41-02, GVP-117, GVP-127 Belts
Thread belts as shown in Fig. 6.
CB-1000 Belt
1. Unlock the cam lock on Strap 2 (Fig. 7).
2. Pull Strap 2 out of the plastic ring on the end of Strap 1.
3. Pull Strap 1 back through Loops 3-5.
4. Insert Strap 1 through the belt slot on the back of the Airmate Blower Unit, then through Loops 3, 4 and 5.
5. Pass Strap 2 through the plastic fitting at the end of Strap 1 and back through the cam lock—adjust to remove slack
and lock in place.
Adjusting 3M™ Comfort Belt Length
The CB-1000 belt can be adjusted at either side of the snap-buckle. The CB-1000 is a one-size-only belt and will
accommodate waist sizes from 26 to 54 inches (66 to 137 centimeters). For waist sizes less than 34 inches (86
centimeters), take the left side of Strap 1 out of Loop 1.
INSPECTION
Failure to conduct an inspection and complete all necessary repairs before use may adversely affect respirator
performance and result in sickness or death.
An inspection must always be performed prior to each use of the respirator as follows:
1. Remove the back cover and filter.
2. Check that the filter gasket is clean, in good condition and properly installed. If not, do not use the PAPR until a
replacement gasket can be installed per these User Instructions.
3. Examine the blower housing for cracks or warping.
4. Check that the battery latch is fully extended under the retaining ledge in the blower housing.
5. Examine the inside of the blower housing and fan assembly. The presence of dust or other particulate matter inside
the blower may indicate a damaged filter or improper seating of the filter/cartridge to the gasket. Contact 3M Technical
Service for assistance.
6. Examine the outside of the battery for cracks. Replace if damaged.
7. Inspect the breathing tube and replace if punctured, cracked or worn.
8. Bend the breathing tube to verify that it is flexible.
9. Successfully complete the User Performance Check.
Failure to pass a user performance check and complete all necessary repairs before use may adversely affect
respirator performance and result in sickness or death.
User Performance Check
Prior to entry into a contaminated area an air flow check should be performed to ensure the system is providing adequate
air flow.
1. Ensure that the breathing tube is connected to the PAPR unit and the HE filter and fully charged battery pack are in
place.
2. Confirm which breathing tube is being used, the newer BE-224 or older 008-00-14. A sticker on one end of the BE-224
breathing tube will say BE-224 (formerly 008-00-14). The sticker for the 008-00-14 breathing tube will just say
008-00-14.
3. Holding the air flow indicator as shown in Fig. 8, locate the two (lower and upper) etched circular bands.
4. Grasp the free end of the breathing tube below the raised ring on the slotted connector. Ensure that the slots on the
connector are open and not covered (Fig. 9).
5. Place the 021-14-00R01 air flow indicator (pointed end first) into the slotted connector. See Fig. 11.
6. Suspend the 3M™ Air-Mate PAPR by the breathing tube so the breathing tube is vertical with no bends or turns
(Fig. 10).The slotted connector should be held at eye level (Fig. 10a).
7. Switch the PAPR unit on. The indicator should “float”on the air coming out (Fig. 11).
a. BE-224 Breathing Tube (formerly 008-00-14): The top of the lower band on the indicator should be at or
above the top of the connector rim.
b. 008-00-14R01 Breathing Tube: The upper band on the indicator should be at or above the top of the
connector rim.
If the indicator fails to rise to the level noted above for the breathing tube in use, airflow is insufficient and the PAPR should
not be used. Refer to the “Troubleshooting” section in the 3M™ Air Mate PAPRAssembly User Instructions.
Entering and Exiting the Contaminated Area
Prior to entering the contaminated area, complete the inspection procedures listed in this User Instructions.
1. Complete assembly, inspection and user performance check of the PAPR assembly as described in these User
Instructions.
2. Complete assembly and fitting of the respirator headgear in accordance with the User Instructions provided with the
respirator headgear.
3. Place the belt with PAPR assembly around the waist and snap the buckle closed.
4. Adjust the belt as needed for a comfortable and secure fit.
5. Press the power switch to turn the system on and verify that air is flowing to the headgear.
6. Don the respirator headgear, then enter the contaminated area.
Note: This PAPR unit and battery are not waterproof. They should not be submersed or subjected to heavy spraying
with water or other liquids. High concentrations of mist or sprays may temporarily clog filters and cause airflow to drop
below safe levels.
7. Do not remove the respirator or reach your hand into the headgear in areas where the air is contaminated.
8. Follow your specific exiting and decontamination procedures for turning off the motor blower and removing the
respirator.
Use of this respirator in atmospheres for which it was not NIOSH certified or designed may result in sickness or
death. Do not wear this respirator where:
- Atmospheres contain hazardous vapors or gases.
- Atmospheres are oxygen deficient.
- Contaminant concentrations are unknown.
- Contaminant concentrations are Immediately Dangerous to Life or Heath (IDLH).
- Contaminant concentrations exceed the maximum use concentration (MUC) determined using the assigned
protection factor (APF) recommended for the applicable headgear or the APF mandated by specific government
standards, whichever is lower.Refer to the User instructions provided with the applicable headgear.
Do not enter a contaminated area until properly donning the respirator system. Do not remove the respirator before
leaving the contaminated area. Doing so may result in sickness or death.
Contaminants that are dangerous to your health include those that you may not be able to see or smell. Leave the
contaminated area immediately if any of the following conditions occur. Failure to do so may result in sickness or
death.
- Airflow decreases or stops.
- Any part of the system becomes damaged.
- Airflow into the respirator decreases or stops.
- Breathing becomes difficult.
- You feel dizzy or your vision is impaired.
- You taste or smell contaminants.
- Your face,eyes, nose or mouth become(s) irritated.
- You suspect that the concentration of contaminants may have reached levels at which this respirator may no
longer provide adequate protection.
Do not expose blower/filter assembly directly to sparks or molten metal spatter. Direct contact with sparks or molten
metal spatter may damage the filter, allowing unfiltered air into the breathing zone,which may result in sickness or
death, and may cause the filter or blower housing to ignite, resulting in serious injury,sickness or death.
CLEANING AND STORAGE
Follow the hygiene practices established by your employer for the specific contaminants to which you have been exposed.
Do not clean respirator with solvents. Cleaning with solvents may degrade some respirator components and reduce
respirator effectiveness. Inspect all respirator components before each use to ensure proper operating conditions.
Failure to do so may result in sickness or death.
Cleaning
Solvents should not be used to clean the PAPR blower unit, battery pack or smart battery chargers. Liquid solvents may
chemically weaken the plastic. Use the following suggested procedures for cleaning:
1. Motor blower unit: Clean the outer surfaces of the 3M™ Air Mate PAPRAssembly with a soft cloth dampened
in a solution of water and mild, pH neutral detergent. Do not immerse theAir Ma te motor blower or battery pack
in water.Do not use solvents or abrasive cleaners.
2. Breathing tube: Clean the connection sites on the breathing tube with the water and detergent solution. The
breathing tube can be immersed in water for cleaning. The inside of the tube must be completely dried prior to
use or storage. Air dry,or dry by connecting to the Air Mate unit and use it to force air through the tube until dry.
3. Comfort Belt: Machine wash in cold water with a mild detergent. Air dry.
4. Filters: Do not attempt to clean the filters. Properly dispose of used filters. Dispose of the filter according to
applicable regulations.
Never attempt to clean filters by knocking or blowing out accumulated material. This may result in damage to the filter
membrane allowing hazardous particles to enter the breathing zone, resulting in sickness or death.
Storage
Store your respirator at room temperature in a dry area that is protected from exposure to hazardous contaminants.
SPECIFICATIONS
Technical
Heat and flame resistance This respirator system is not designed for use in high temperature environments and
should not be exposed to sparks or flame.
Battery pack Rechargeable nickel cadmium.
Up to 8 hrs of use per charge.
Charge batteries at a temperature of 77°F (25ºC) or less
Airflow range Greater than 6 cfm (170 lpm)
Weight PAPR Approxima tely 1.1 lb (0.5 kg)
Weight battery pack Approximately 1.7 lb (0.8 kg)
Assigned Protection Factor
Refer to the User Instructions for the specific headgear to be used to determine the assigned protection factor for the Air-
Mate PAPR system. Consult to 3M™Technical Data Bulletin #175 (www.3M.com/OccSafety) for additional information
on APFs and supporting test data. In Canada,follo w CSA standard Z94.4 or the requirements of the authority having
jurisdiction in your region.
SYSTEM COMPONENTS AND REPLACEMENT PARTS
Do not use with parts or accessories other than those manufactured by 3M™ as described in these User Instructions or
on the NIOSH approval label for this respirator. Do not attempt to repair or modify any component of the system except
as described in these User Instructions. Failure to do so may adversely affect respirator performance and result in
sickness or death.
3M™ Components, Replacement Parts
Product Number Description
231-01-30 Air-Mate™ PAPRAssembly (includes PAPR unit, battery, filter,web belt and airflow indicator)
231-01-30U Air-Mate™ PAPRAssembly (includes PAPR unit, battery, filter,vinyl belt and airflow indicator)
AMH-1U Air-Mate™ PAPRAssembly (includes PAPR unit, battery, filter,vinyl belt and airflow indicator,
smart battery charger, external charge adapter, breathing tube BE-224 and breathing tube covers)
AMH-12U Air-Mate™ PAPR Assembly (includes PAPR assembly 231-01-30U, battery, filter, vinyl belt, ,
airflow indicator, plus smart battery charger,external charge adapter, breathing tube BE-224,
breathing tube covers, headcover BE-12-3 regular and storage bag)
520-03-63R01 Air-Mate™ PAPR Unit (does not include battery pack, belt and airflow indicator) (Fig.1)
007-00-15R01 Battery Pack
451-02-01R01 High Efficiency Filter (includes gasket)
GVP-127 Waist Belt, Web
021-41-02R01 Waist Belt, Nylon, 59” long (150 cm)
GVP-117 Waist Belt, Vinyl (Deconable)
CB-1000 Comfort Belt (fits waist sizes from 26 – 52 in (66 to 132 centimeters)
021-14-00R01 Airflow Indicator – for use with BE-224 breathing tube
021-10-07R01 Back Cover (for PAPR unit)
520-03-73 Smart Battery Charger
520-04-24 External Charge Adaptor
BE-224 Breathing tube – for use with BE-series headgear
Consult the NIOSH approval label(s) supplied with the product or contact 3M TechnicalSer vice for information on any
additional breathing tubes, headgear,or other system components that may be approved for use with the Air- Mate™
blower unit.
3M™ Accessories
Product Number Description
W-3228-10 Breathing Tube Cover
520-03-72 Smart Battery Charger, 5-Unit
520-01-61 Smart Battery Charger, 10-Unit
520-01-61SGL Smart Battery Charger,Single Unit (Canada only)
520-01-61FIV Smart Battery Charger, 5-Unit (Canada only)
TROUBLESHOOTING
Problem Possible Cause Corrective Action
You smell or taste contaminants or
an irritation occurs.
Misuse, improper assembly or
malfunction of equipment.
Leave work area immediately
and contact your supervisor.
Do not use the PAPR until the
cause is identified and corrected.
Blower does not run when switch is
depressed.
Battery is discharged.
Faulty power switch.
Faulty motor.
Recharge 14-16 hours.
Replace battery pack.
Replace motor/blower.
Battery does not accept charge, but
PAPR unit runs when plugged into
charger.
Faulty battery connection or
terminals dirty/damaged.
Check that battery terminals are clean and
battery is properly attached and locked
into the PAPR housing.
PAPR fails airflow test. Clogged filter.
Battery needs charging.
Battery does not hold charge.
Breathing tube blocked.
Replace filter.
Charge battery.
Replace battery.
Locate and remove restriction.
APPENDIX 1
Performance Check With AFI-200 Air Flow Indicator
1. Ensure the HE filter is in place and the battery pack is installed and fully charged. The breathing tube should be
disconnected from the 3M™ Air Mate™ PAPR.
2. Insert the AFI-200 into the air outlet on the top of the Air Mate™ PAPR (Fig.A-1).
3. Switch the PAPR unit on. Hold the PAPR so the AFI-200 is vertical and at eye level.
4. The ball in the AFI-200 should rise above the line indicated on the side of the tube. If the ball rises above the line this
indicates sufficient airflow.
5. If the ball fails to rise to this level, airflow is insufficient. This may be the result of a low battery charge, a clogged filter
or another malfunction. Refer to the “Troubleshooting” section. Do not enter a contaminated area until the malfunction
is corrected and air flow test is passed.
IMPORTANT NOTICE
WARRANTY: In the event any 3M OH&ESD product is found to be defective in material, workmanship,or not in
conformation with any express warranty for a specific purpose, 3M’s only obligation and your exclusive remedy shall be,at
3M’s option, to repair, replace or refund the purchase price of such parts or products upon timely notification thereof and
substantiation that the product has been stored, maintained and used in accordance with 3M’s written instructions.
EXCLUSIONS TO WARRANTY: THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY IMPLIED WARRANTY OF
MERCHANTABILITY, FITNESS FOR A PARTICULARPURPOSE OR OTHER WARRANTY OF QUALITY, EXCEPT OF TITLE AND
AGAINST PATENTINFRINGEMENT.
LIMITATIONOF LIABILITY: Except as provided above, 3M shall not be liable or responsible for any loss or damage, whether
direct, indirect, incidental,special or consequential, arising out of sale, use or misuse of 3M OH&ESD products, or the user’s
inability to use such products. THE REMEDIES SET FORTH HEREINARE EXCLUSIVE.
FOR MORE INFORMATION
In United States, contact:
Website: www.3M.com/OccSafety
TechnicalAssistance: 1-800-243-4630
For other 3M products:
1-800-3M-HELPS or
1-651-737-6501
This product helps protect against certain airborne particles. Misuse may result in sickness or death.
For proper use, see supervisor,User Instructions, or call 3M in U.S.A., 1-800-243-4630. In Canada, call
Technical Service at 1-800-267-4414.
FORWARD
Contact Information
Read all instructions and warnings before using. Keep these User Instructions for reference. If you have questions regarding
these products contact 3M TechnicalSer vice.
In United States In Canada
Website: www.3M.com/OccSafety Website: www.3M.com/CA/OccSafety
Technical Service: 1-800 243-4630 Technical Service: 1-800-267-4414
Ce produit protège contre certaines particules en suspension dans l’air.Une mauvaise utilisation peut
provoquer des problèmes de santé ou la mort. Pour tout renseignement sur l’utilisation adéquate de
ce produit, consulter son superviseur,lire les directives d’utilisation ou communiquer, au Canada, avec le
Service technique au 1 800 267-4414.
AVANT-PROPOS
Personnes-ressources
Lire toutes les directives et mises en garde avant l’utilisation. Conserver ces directives d’utilisation à titre de référence.
Pour toute question au sujet de ces produits, communiquer avec le Service technique de 3M.
États-Unis Canada
Site Web : www.3M.com/OccSafety Site Web : www.3M.com/CA/OccSafety
Service technique : 1 800 243-4630 Service technique : 1 800 267-4414
Este producto ayuda a proteger contra ciertas partículas suspendidas en el aire. El mal uso puede
ocasionar enfermedad o incluso la muerte. Para su uso adecuado consulte a su supervisor,lea las
Instrucciones, o llame a 3M en EUA al 1-800-243-4630. En Canadá llame al Servicio Técnico al 1-800-267-4414.En
México llame al 01-800-712-0646; o contacte a 3M en su país.
HACIA DELANTE
Contacto
Lea todas las instrucciones y advertencias antes de usar el producto. Conserve estas Instrucciones para referencia futura.
Si tiene alguna duda sobre estos productos contacte al Servicio Técnico 3M.
En Estados Unidos: En Canadá
Sitio Web: www.3M.com/OccSafety Sitio Web: www.3M.com/CA/OccSafety
Servicio técnico: 1-800 243-4630 Servicio técnico: 1-800-267-4414
Este produto ajuda a proteger contra certas partículas no ar.O uso inadequado pode resultar em
enfermidade ou morte. Para o uso adequado, leia as Instruções de Uso na embalagem,consulte seu
supervisor ou um higienista ou ligue para o disque segurança da 3M pelo fone 0800-0550705.
AVANÇAR
Informações de Contato
Leia todas as instruções e advertências antes de usar.Guarde estas Instruções de Uso para referência. Se você tiver
perguntas com relação a estes produtos, entre em contato com a assistência técnica da 3M.
Nos Estados Unidos: No Canadá
Site: www.3M.com/OccSafety Site: www.3M.com/OccSafety
Serviço Técnico: 1-800-243-4630 Serviço Técnico: 1-800-267-4414
WWARNING
WWARNING
WWARNING
WWARNING
WWARNING
WWARNING
WWARNING
WWARNING
WMISE EN GARDE
Principales sections de la norme 29 CFR 1910.134 de l'OSHA
Section Description
A Permissible Practice (pratique permise)
B Définitions
C Respiratory Protection Program (programme de protection respiratoire)
D Selection of Respirators (sélection des respirateurs)
E Medical Evaluation (examen médical)
F Fit Testing(essai d'ajustement)
G Use of Respirators (utilisation des respirateurs)
H Maintenance and Care of Respirators (entretien des respirateurs)
I Breathing Air Quality and Use (qualité et utilisation de l'air respirable)
J Identification of Cartridges, Filters, and Canisters (cartouches, filtres et boîtiers filtrants)
K Training and Information (formation et renseignements)
L Program Evaluation (évaluation du programme)
M Recordkeeping(tenue de dossiers)
Avant d'utiliser ce respirateur,chaque utilisa teur doit lire et comprendre les présentes directives d’utilisation.
L’utilisation de ces respirateurs par des personnes qui n’ont pas reçu la formation nécessaire ou qui n’ont pas les
qualifications requises, ou l’utilisation non conforme aux présentes directives d'utilisation peut diminuer l’efficacité du
respirateur et provoquer des problèmes de santé ou la mort.
NIOSH – HOMOLOGATION, AVERTISSEMENTSET RESTRICTIONS
Homologation du NIOSH
Pour obtenir une liste des composants des respirateurs d’épuration d’air propulsé Air-Mate™3M™homologués par le
NIOSH, consulter l’étiquette d’homologation du NIOSH comprise avec le produit ou communiquer avec le Service technique
de 3M au 1 800 267-4414.
Avertissements et restrictions du NIOSH
A – Ne pas utiliser lorsque la concentration ambiante en oxygène est inférieure à 19,5%.
B – Ne pas utiliser si l'atmosphère présente un danger immédiat pour la vie ou la santé.
C – Ne pas utiliser en présence de concentrations supérieures au taux établi par la réglementation.
F – Ne pas utiliser de respirateurs d’épuration d’air propulsé si le débit d’air est inférieur à 115 l/min (4 pi³/min) en ce qui
a trait aux masques à ajustement serré ou à 170 l/min (6 pi³/min) en ce qui a trait aux cagoules et/ou aux casques.
I – Comporte des pièces électriques qui peuvent provoquer une inflammation dans les atmosphères inflammables ou
explosives.
J – L’utilisation et l’entretien inadéquats de ce produit peuvent provoquer des blessures ou la mort.
L – Pour le changement des cartouches, des boîtiers filtrants et/ou des filtres, suivre les directives d’utilisation du
fabricant.
M – Tous les respirateurs homologués doivent être sélectionnés,ajustés, portés et entretenus conformément aux
règlements de la MSHA, de l’OSHA et à tout autre règlement en vigueur.
N – Ne jamais substituer ou modifier ce produit, ni lui ajouter ou lui enlever des pièces.N’utiliser que les pièces de
rechange exactes déterminées par le fabricant.
O – Consulter les directives d’utilisation et/ou les manuels d’entretien pour obtenir des renseignements sur l’utilisation et
l’entretien de ces respirateurs.
P – Le NIOSH n’évalue pas les respirateurs comme masques chirurgicaux.
MODE D'EMPLOI
Montage
Tuyau de respiration
Pour raccorder le tuyau de respiration BE-224, ou l'ancien tuyau de respiration 008-00-14, au respirateur d’épuration d’air
propulsé, insérer le tuyau (extrémité mâle avec broches) dans le respirateur et tourner vers la droite pour le verrouiller.Pour
raccorder le tuyau de respiration à la pièce faciale, consulter les directives d’utilisation de la pièce faciale.
Installation du bloc-piles
1. Retirer le couvercle arrière et le filtre du respirateur d'épuration d'air propulsé.
2. Insérer le bloc-piles dans son compartiment en exerçant une pression pour le caler en place et pour engager les
bornes du bloc-piles dans la prise située sur le côté du bloc-piles (Fig. 1).
3. Faire glisser la pince du bloc-piles sous la fente du boîtier pour maintenir en place.
4. Vérifier si le joint d'étanchéité du filtre est bien installé dans la rainure du boîtier (Fig. 1).
5. Replacer le filtre en s'assurant que les flèches pointent vers le bloc-piles (Fig. 2).
6. Remettre le couvercle arrière en place en appuyant sur celui-ci jusqu'à ce qu'il s'enclenche.
7. Avant l'utilisation, charger le bloc-piles conformément aux directives de charge du bloc-piles.
Charge du bloc-piles
1. Pour utiliser le chargeur intelligent 3M™, le placer horizontalement sur une surface plane et brancher son cordon
d’alimentation c.a. dans une prise 120 V, 60 Hz.
2. Le voyant à DEL vert s'allume.
3. Insérer le fil de charge dans la prise de charge située sur le côté de l'unité. On peut également retirer le bloc-piles du
boîtier et le charger à l'aide de l'adaptateur de charge externe (numéro de produit 520-04-24) (Fig. 3).
4. Le voyant à DEL s'éteint, indiquant que le bloc-piles relié est en train d'être chargé en mode rapide.
5. Après environ huit heures (selon la charge requise), le voyant à DEL se rallume, indiquant que le chargeur est passé
en mode à faible régime. Le voyant à DEL des chargeurs utilisés au Canada clignote toutes les 3 à 5 secondes lorsque
l’appareil est en mode à faible régime.
6. Le bloc-piles du respirateur Air-Mate offre jusqu'à 500 cycles de charge/décharge. Cependant,la durée utile du bloc-
piles sera réduite de manière importante s'il est exposé à une température élevée pendant une période prolongée.
Observer les directives ci-dessous pour maximiser la durée utile du bloc-piles.
– Charger le bloc-piles 3M™avant qu’il soit complètement déchargé. Le fait de décharger complètement le bloc-piles de
façon régulière risque de l'endommager.
– Il est possible de charger le bloc-piles 3M™en tout temps pendant le cycle de décharge. Contrairement à certaines
piles au nickel-cadmium, le bloc-piles 3M™n'a pas de « mémoire ». Qu'il ait été utilisé pendant 30 minutes ou
8 heures, on peut le charger.
– Toujours charger le bloc-piles à une température d'au plus 25°C (77°F).À des tempéra tures plus élevées,le bloc-piles
WMISE EN GARDE
peut ne pas se charger complètement. Si le bloc-piles est chaud, le laisser refroidir pendant une demi-heure avant de
le charger.
– Il est possible de laisser le bloc-piles dans le chargeur en mode à faible régime pendant au plus 30 jours pour
maintenir sa capacité maximale. Ne pas laisser entreposer les blocs-piles branchés au chargeur pendant de longues
périodes. Sans chargement périodique, une pile au nickel-cadmium entreposée perd environ 1% de sa charge par jour.
Lorsqu'un bloc-piles est utilisé peu fréquemment, celui-ci doit être chargé complètement au départ, puis rechargé
pendant la nuit une fois par semaine ou une heure chaque jour pour conserver sa charge complète. Un bloc-piles
soumis à un entreposage prolongé (plus de 6 mois) peut perdre sa capacité à retenir une charge complète. Vérifier la
capacité du bloc-piles en faisant fonctionner le souffleur à moteur du respirateur d'épuration d'air propulsé pendant
8 heures en s'assurant que le débit d'air se situe à 6 pi³/min ou plus. Plusieurs cycles de charge et de décharge
peuvent restaurer la capacité du bloc-piles.
– Dans le cas d'un bloc-piles utilisé peu fréquemment, vérifier régulièrement sa capacité en faisant fonctionner le
souffleur à moteur du respirateur et en notant pendant combien de temps le débit d'air requis, mesuré à l'aide du
débitmètre, est maintenu.
– Ne pas charger plusieurs blocs-piles dans une armoire fermée sans aération.
– Pour la mise au rebut adéquate du bloc-piles, consulter les règlements locaux sur l’élimination des déchets solides ou les
directives de mise au rebut des piles de la RBRC, ou téléphoner à la ligne d'aide de la RBRC au 1 800 822-8837.
Remplacement du filtre et du joint d'étanchéité de filtre
Changer le filtre à haute efficacité dans les cas ci-dessous :
– Lorsqu'une vérification du débit du respirateur d’épuration d’air propulsé révèle que la mesure du débitmètre est
inférieure au débit requis (respirateur alimenté par une pile bien chargée);
– Lorsque le filtre est endommagé;
– Lorsque de l'eau a pénétré dans le filtre;
– Afin d'être conforme avec les procédures administratives locales.
Retrait du filtre et du joint d'étanchéité de filtre
1. Tirer sur la ceinture entre les ganses pour former une boucle et l'écarter du respirateur d’épuration d’air propulsé
(Fig. 4).
2. Détacher les languettes de verrouillage du couvercle arrière pour enlever le couvercle.
3. Enlever le filtre à haute efficacité et son joint d'étanchéité (situé dans la rainure de soutien à l'intérieur du respirateur
d’épuration d’air propulsé – Fig. 1) et les jeter au rebut conformément aux réglementations locale, provinciale et
fédérale. On peut retirer le joint d'étanchéité avec de petites pinces (Fig. 5).Il faut remplacer le joint d'étanchéité
lorsqu'on installe un filtre neuf.
Remplacement du filtre et du joint d'étanchéité
1. Vérifier si le nouveau joint d'étanchéité du filtre n'est pas déformé ou endommagé avant de l'installer.
2. Installer le nouveau filtre dans la rainure de soutien du filtre, à égalité avec les côtés du respirateur d’épuration d’air
propulsé et sans laisser de vides.
3. Installer le filtre de remplacement dans le respirateur d’épuration d’air propulsé, les flèches pointant vers l'intérieur de
ce dernier (Fig. 2).
4. Enclencher les languettes de verrouillage du couvercle arrière sur l'arrière du respirateur d’épuration d’air propulsé.
5. Tirer sur la ceinture à l'extérieur des ganses.
Installation des ceintures
Ceintures 021-41-02, GVP-117 et GVP-127
Enfiler la ceinture comme le montre la Fig. 6.
CEINTURE CB-1000
1. Déverrouiller le verrou à came de la courroie 2 (Fig.7).
2. Sortir la courroie 2 de la boucle en plastique à l'extrémité de la courroie 1.
3. Repasser la courroie 1 dans les ganses 3 à 5.
4. Passer la courroie 1 dans la fente de la ceinture à l'arrière du souffleur Air-Mate, puis dans les ganses 3, 4 et 5.
5. Passer la courroie 2 dans la boucle en plastique à l'extrémité de la courroie 1 et ramener dans le verrou à came –
ajuster pour enlever le mou et bloquer en place.
Réglage de la longueur de la ceinture confort 3M™
La ceinture CB-1000 peut être ajustée d'un côté ou l'autre de la fermeture. La ceinture CB-1000 est offerte en une seule
longueur convenant aux tailles de 66 à 137 cm (26 à 54 po). Pour les tailles inférieures à 86 cm (34 po), retirer l'extrémité
gauche de la courroie 1 de la ganse 1.
Inspection
Le fait de ne pas procéder à une inspection et de ne pas effectuer toutes les réparations nécessaires avant d’utiliser le
respirateur peut diminuer l’efficacité de ce dernier et provoquer des problèmes de santé ou la mort.
Il faut toujours procéder à une inspection avant chaque utilisation du respirateur.Voici comment procéder :
1. Retirer le couvercle arrière et le filtre.
2. Vérifier si le joint d'étanchéité du filtre est propre, en bon état et bien installé. Sinon, ne pas utiliser le respirateur
d’épuration d’air propulsé sans avoir remplacé le joint d'étanchéité conformément aux directives d'utilisation.
3. Examiner le carter du souffleur et s'assurer qu'il est exempt de fissures ou de déformations.
4. Vérifier que le verrou du bloc-piles se prolonge complètement sous la barre de retenue dans le boîtier du souffleur.
5. Examiner l'intérieur du boîtier du souffleur et le ventilateur. La présence de poussière ou d'autres particules à
l'intérieur du souffleur peut indiquer un filtre endommagé ou un filtre/une cartouche mal installés sur le joint
d'étanchéité. Communiquer avec le Service technique de 3M pour obtenir de l'aide.
6. Vérifier si l'extérieur du boîtier du bloc-piles est craqué. Le remplacer s'il est endommagé.
7. Inspecter le tuyau de respiration et le remplacer s'il est percé, craqué ou usé.
8. Plier le tuyau pour s'assurer de sa souplesse.
9. Effectuer un essai de fonctionnement réussi.
Le fait de ne pas procéder à un essai de fonctionnement et de ne pas effectuer toutes les réparations nécessaires avant
d’utiliser le respirateur peut diminuer l’efficacité de ce dernier et provoquer des problèmes de santé ou la mort.
Essai de fonctionnement
Avant de pénétrer dans une zone contaminée, effectuer une vérification du débit pour vérifier si le système procure un débit
d'air suffisant.
1. S'assurer que le tuyau de respiration est branché au respirateur et au filtre HE et qu'un bloc-piles complètement
chargé est en place.
2. Vérifier quel tuyau de respiration est utilisé; le plus récent, BE-224, ou l'ancien, 008-00-14. Une étiquette apposée
à l'une des extrémités du tuyau de respiration BE-224 indiquera BE-224 (anciennement 008-00-14). L'étiquette du
tuyau de respiration 008-00-14 n'indiquera que le numéro 008-00-14.
3. Tenir le débitmètre comme le montre la Fig. 8,puis repérer les deux bandes circulaires gra vées (inférieure et
supérieure).
4. Tenir le tuyau de respiration sous l'anneau surélevé du connecteur fendu. S'assurer que les fentes du connecteur ne
sont pas obturées (Fig. 9).
5. Placer le débitmètre 021-14-00R01 (extrémité pointue en premier) dans le connecteur fendu (Fig. 11).
6. Suspendre le respirateur d'épuration d'air propulsé Air-Mate par le tuyau de respiration pour que ce dernier soit à
la verticale sans qu'il ne soit plié ou tordu (Fig. 10). Le connecteur à fentes devrait être tenu à la hauteur des yeux
(Fig. 10a).
7. Mettre le respirateur d'épuration d'air propulsé sous tension. L'indicateur devrait « flotter » sur l'air qui sort (Fig. 11).
a. Tuyau de respiration BE-224 (anciennement 008-00-14) : Le dessus de la bande inférieure de l'indicateur
devrait se trouver au même niveau que le rebord du connecteur ou au-dessus.
b. Tuyau de respiration 008-00-14R01 : La bande supérieure de l'indicateur devrait se trouver au même niveau
que le rebord du connecteur ou au-dessus.
Si l'indicateur ne se situe pas au niveau indiqué précédemment pour le tuyau de respirateur utilisé, le débit d'air est
insuffisant et le respirateur d'épuration d'air propulsé ne devrait pas être utilisé. Consulter la section Tableau de dépannage
des directives d'utilisation de l'ensemble respirateur d'épuration d'air propulsé Air-Mate 3M™.
Entrée et sortie de la zone contaminée
Avant d'entrer dans une zone contaminée, effectuer les inspections indiquées dans les présentes directives d’utilisation.
1. Procéder au montage, à l’inspection et à l’essai de fonctionnement du respirateur d’épuration d’air propulsé
conformément aux présentes directives d’utilisation.
2. Procéder au montage et à l'ajustement de la pièce faciale du respirateur conformément aux directives d’utilisation
fournies avec la pièce faciale.
3. Placer la ceinture de l'ensemble respirateur d'épuration d'air propulsé autour de la taille et enclencher la boucle.
4. Régler la longueur de la ceinture de manière à obtenir un ajustement confortable et sécuritaire.
5. Appuyer sur l'interrupteur pour mettre le système en marche et vérifier si la pièce faciale reçoit de l'air.
6. Enfiler la pièce faciale puis entrer dans la zone contaminée.
Remarque : Le respirateur d’épuration d’air propulsé et le bloc-piles ne sont pas étanches à l’eau. Ils ne doivent pas
être submergés ou soumis à des pulvérisations abondantes d’eau ou d’autres liquides. De fortes concentrations de
brouillards ou de pulvérisations peuvent temporairement bloquer le filtre et abaisser le débit d’air sous les seuils de
sécurité.
7. Dans les endroits où l'air est contaminé, ne pas enlever le respirateur ni introduire les mains dans la pièce faciale.
8. Suivre les procédures d'évacuation et de décontamination pertinentes pour mettre le souffleur à moteur hors tension
et enlever le respirateur.
Accessoires 3M™
Numéro de produit Description
W-3228-10 Gaine pour tuyau de respiration
520-03-72 Chargeur de pile intelligent pour 5 unités
520-01-61 Chargeur de pile intelligent pour 10 unités
520-01-61SGL Chargeur de pile intelligent pour 1 unité (Canada seulement)
520-01-61FIV Chargeur de pile intelligent pour 5 unités (Canada seulement)
DÉPANNAGE
Anomalie Causes possibles Correctifs
L'utilisateur goûte ou sent des
contaminants ou ressent une
irritation.
Mauvaise utilisation, montage incorrect
ou matériel défectueux
Quitter immédiatement les lieux
et communiquer avec son superviseur.
Ne pas utiliser le respirateur
d'épuration d'air propulsé
avant d'avoir trouvé la cause et
corrigé le problème.
Le souffleur ne fonctionne pas
lorsqu'on appuie sur l'interrupteur.
Bloc-piles déchargé
Défaillance de l'interrupteur
d'alimentation
Défaillance du moteur
Durée de recharge : 14 à 16 heures
Remplacer le bloc-piles.
Remplacer le souffleur à moteur.
Le bloc-piles ne conserve pas
la charge, mais le respirateur
fonctionne s'il est branché au
chargeur.
Connexion du bloc-piles défectueuse ou
bornes sales ou endommagées
Vérifier si les bornes de la pile
sont propres et que la pile est bien
raccordée et fixée dans le boîtier du
respirateur.
Le respirateur d'épuration d'air
propulsé ne passe pas l'essai de
débit d'air.
Le filtre est encrassé.
Charger la pile.
Le bloc-piles ne conserve pas sa charge.
Le tuyau de respiration est bouché.
Remplacer le filtre.
Charger la pile.
Remplacer le bloc-piles.
Déboucher le tuyau.
ANNEXE 1
Essai de fonctionnement avec le débitmètre AFI-200
1. S'assurer que le filtre HE est en place, que le bloc-piles est installé et chargé complètement. Le tuyau de respiration
doit être débranché du respirateur d’épuration d’air propulsé Air-Mate™3M™.
2. Insérer le débitmètre AFI-200 dans la sortie d'air sur le dessus du respirateur (Fig. A-1).
3. Mettre le respirateur d'épuration d'air propulsé sous tension. Tenir le respirateur d’épuration d’air propulsé de manière
que le débitmètre AFI-200 soit à la verticale et à la hauteur des yeux.
4. La sphère du débitmètre AFI-200 doit monter au-dessus de la ligne marquée sur le côté du tuyau. Si la sphère monte
au-dessus de la ligne, le débit d'air est suffisant.
5. Si la sphère ne monte pas à ce niveau, le débit d'air est insuffisant. Cette insuffisance peut être causée par un bloc-
piles de faible charge, un filtre encrassé ou une autre anomalie. Consulter la section Dépannage.Ne pas pénétrer dans
une zone contaminée avant d'avoir corrigé l'anomalie et réussi un essai de débit d'air.
AVIS IMPORTANT
GARANTIE : Dans le cas où un produit d’hygiène industrielle et de sécurité environnementale 3M présenterait un défaut
de matériau ou de fabrication ou ne serait pas conforme à toute garantie ou condition explicite d’adaptation à un usage
particulier,la seule obligation de 3M, qui constitue le recours exclusif de l’acheteur, est, au gré de 3M,de réparer ou de
remplacer les pièces ou les produits jugés défectueux ou encore d’en rembourser le prix d’achat, à condition que l’acheteur
avise 3M en temps opportun et qu’il présente une preuve que le produit a été entreposé, entretenu et utilisé conformément
aux directives écrites de 3M.
RESTRICTIONS DE GARANTIE : LA PRÉSENTE GARANTIE EST EXCLUSIVE ET TIENT LIEU DE TOUTE GARANTIE
OU CONDITION IMPLICITE DE QUALITÉ MARCHANDE ET D’ADAPTATION À UN USAGE PARTICULIER OU DE TOUTE
AUTRE GARANTIE DE QUALITÉ, À L’EXCEPTIONDES GARANTIES RELATIVES AUX TITRES DE PROPRIÉTÉ ET À LA
CONTREFAÇON DE BREVETS.
LIMITE DE RESPONSABILITÉ : À l’exception des dispositions précédentes, 3M ne peut être tenue responsable des pertes
ou dommages directs, indirects, fortuits,spéciaux ou conséquents, résultant de la vente, de l’utilisation ou de la mauvaise
utilisation des produits d’hygiène industrielle et de sécurité environnementale de 3M, ou encore de l’incapacité à s’en
servir. LES RECOURS ÉNONCÉSAUX PRÉSENTES SONT EXCLUSIFS.
POUR OBTENIR DE PLUS AMPLES RENSEIGNEMENTS/FOR MORE INFORMATION
Au Canada, communiquer avec/In Canada, contact :
Internet : www.3M.com/CA/OccSafety
Assistance technique/Technical Assistance :
1 800 267-4414
Pour les autres produits 3M/For other 3M products :
1 800 364-3577
WMISE EN GARDE
1. Souffleur à moteur : Nettoyer les surfaces extérieures de l'ensemble respirateur d'épuration d'air propulsé
Air-Mate 3M™avec un chiffon doux humecté d'une solution d'eau propre et de détergent doux à pH neutre. Ne
pas plonger le souffleur à moteur ou le bloc-piles du respirateur Air-Mate dans l'eau. Ne pas utiliser de solvants
ni de nettoyants abrasifs.
2. Tuyaux de respiration : Nettoyer les extrémités à raccorder avec de l'eau et une solution de détergent.On peut
faire tremper le tuyau de respiration dans l'eau pour le nettoyer. L'intérieur du tuyau de respiration doit être
complètement sec avant l'utilisation ou l'entreposage. Pour faire sécher le tuyau de respiration, le raccorder au
respirateur d'épuration d'air propulsé Air-Mate et souffler de l'air à l'intérieur de celui-ci jusqu'à ce qu'il soit sec.
3. Ceinture confort : Laver à la machine dans l'eau froide avec un détergent doux. Sécher à l air.
4. Filtres : Ne pas tenter de nettoyer les filtres. Mettre adéquatement les filtres usés au rebut. Mettre le filtre au
rebut conformément aux règlements applicables.
Ne jamais essayer de nettoyer les filtres en cognant le respirateur ou en soufflant de manière à déloger les substances
accumulées. Cela peut endommager la membrane du filtre et permettre aux particules nocives de pénétrer dans la
zone de respiration de l’utilisateur, provoquant ainsi des problèmes de santé ou la mort.
Entreposage
Entreposer le respirateur à température ambiante dans un endroit sec, à l’abri des contaminants dangereux.
SPÉCIFICATIONS
Spécifications techniques
Résistance à la chaleur et
aux flammes. Ce respirateur n’est pas conçu pour les milieux où règne une température élevée et ne
doit donc pas être directement exposé à des étincelles ou à des flammes.
Bloc-piles Nickel-cadmium rechargeable
Huit heures d'utilisation maximale par charge
Charger les piles à une température d'au plus 25°C (77°F).
Plage de débits d'air Supérieureà 170 l/min (6 pi³/min)
Poids du respirateur
d’épuration d’air propulsé Environ 0,5 kg (1,1 lb)
Poids du bloc-piles Environ 0,8 kg (1,7 lb)
Facteur de protection caractéristique
Consulter les directives d'utilisation fournies avec la pièce faciale utilisée pour déterminer le facteur de protection
caractéristique du respirateur d'épuration d'air propulsé Air-Mate. Consulter le bulletin technique 3M™n° 175
(www.3M.com/OccSafety) pour obtenir de plus amples renseignements sur les FPC et les résultats des essais pertinents.
Au Canada, se conformer à la norme Z94.4 de la CSA ou aux exigences de l’autorité compétente de sa région.
COMPOSANTS DU SYSTÈME ET PIÈCES DE RECHANGE
Ne pas utiliser avec des pièces ou des accessoires autres que ceux fabriqués par 3M, conformément aux présentes
directives d’utilisation ou à l’étiquette d’homologation du NIOSH du respirateur utilisé. Ne pas tenter de réparer
ou de modifier les composants du système, sauf comme le décrivent les présentes directives d’utilisation. Tout
manquement à ces directives peut diminuer l’efficacité du respirateur et provoquer des problèmes de santé
ou la mort.
Composants et pièces de rechange 3M™
Numéro de produit Description
231-01-30 Ensemble respira teur d'épuration d'air propulséAir-Mate™(avec respirateur d'épuration d'air
propulsé, bloc-piles, filtre,ceinture en toile et débitmètre)
231-01-30U Ensemble respirateur d'épuration d'air propulsé Air-Mate™(avecrespirateur d'épura tion d'air
propulsé, bloc-piles, filtre,ceinture en vinyle et débitmètre)
AMH-1U Ensemble respirateur d'épuration d'air propulsé Air-Mate™(avec respirateur d'épuration d'air
propulsé, bloc-piles, filtre, ceinture en vinyle, débitmètre, chargeur de pile intelligent, adaptateur
de charge externe, tuyau de respiration BE-224 et gaines pour tuyau de respiration)
AMH-12U Ensemble respira teur d'épuration d'air propulséAir-Mate™(avec respirateur d'épuration
d'air propulsé 231-01-30U, bloc-piles, filtre,ceinture en vinyle, débitmètre, chargeur de pile
intelligent, adaptateur de charge externe, tuyau de respiration BE-224, gaines pour tuyau de
respiration, pièce faciale BE-12-3 taille normale et sac de rangement)
520-03-63R01 Ensemble respirateur d'épuration d'air propulsé Air-Mate™(bloc-piles,ceinture et débitmètre
non inclus) (Fig. 1)
007-00-15R01 Bloc-piles
451-02-01R01 Filtre à haute efficacité avec joint d'étanchéité
GVP-127 Ceinture en toile
021-41-02R01 Ceinture en nylon de 150 cm (59 po)
GVP-117 Ceinture en vinyle (décontaminable)
CB-1000 Ceintureconfort (taille de 66 à 132 cm ou 26 à 52 po)
021-14-00R01 Débitmètre à utiliser avec le tuyau de respiration BE-224
021-10-07R01 Couvercle arrière (respirateur d’épuration d’air propulsé)
520-03-73 Chargeur de pile intelligent
520-04-24 Ada ptateur de charge externe
BE-224 Tuyau de respiration,à utiliser a vec la pièce faciale de série BE
Consultez l’étiquette ou les étiquettes d’homologation du NIOSH fourni(s) avec le produit ou communiquez avec le Service
technique de 3M pour obtenir des renseignements sur les divers tuyaux de respiration ou pièces faciales ou les autres
composants du système dont l’utilisation pourrait être approuvée avec le souffleur Air-Mate™.
WMISE EN GARDE
WMISE EN GARDE
WMISE EN GARDE
L’utilisation de ce respirateur dans des atmosphères pour lesquelles il n’a pas été conçu ou homologué par le NIOSH peut
provoquer des problèmes de santé ou la mort. Ne pas porter ce respirateur en présence des conditions ci-dessous :
- Atmosphères contenant des vapeurs ou des gaz dangereux;
- Atmosphères déficientes en oxygène;
- Atmosphères où les concentrations des contaminants sont inconnues;
- Lorsque les concentrations des contaminants sont inconnues ou présentent un danger immédiat pour la vie ou la
santé (divs);
- Atmosphères où les concentrations de contaminants sont supérieures à la concentration d'utilisation maximale
déterminée à l'aide du facteur de protection caractéristique (fpc) recommandé pour la pièce faciale applicable ou
au fpc établi par des normes gouvernementales spécifiques, selon la valeur la moins élevée. Consulter les directives
d'utilisation fournies avec la pièce faciale en question.
Ne pas pénétrer dans une zone contaminée sans s'assurer que le respirateur a été mis en place correctement. Ne pas
retirer le respirateur avant de sortir de la zone contaminée. Tout manquement à ces directives peut provoquer des
problèmes de santé ou la mort.
Les contaminants dangereux pour la santé englobent les particules trop petites pour être senties ou être visibles à l’œil
nu. Quitter immédiatement la zone contaminée si l’une ou l’autre des conditions ci-dessous survient. Toutmanquement
à ces directives peut provoquer des problèmes de santé ou la mort.
- Le débit d'air diminue ou s'arrête;
- Une partie du système est endommagée;
- Le débit d’air alimentant le respirateur diminue ou s’arrête;
- La respiration devient difficile;
- On éprouve des étourdissements ou des problèmes de vision;
- On décèle un goût ou une odeur de contaminants;
- On ressent une irritation au visage, aux yeux, au nez ou à la bouche;
- On pense que la concentration des contaminants a atteint un niveau tel que le respirateur ne fournit plus une
protection adéquate.
Ne pas exposer l'ensemble souffleur et filtre directement aux étincelles ou aux projections de métal en fusion. Le contact
direct avec des étincelles ou des projections de métal en fusion peut endommager le filtre et ainsi laisser pénétrer de
l'air non filtré dans la zone de respiration de l'utilisateur, ce qui peut provoquer des problèmes de santé ou la mort.
Le filtre et le boîtier du souffleur risquent alors de s'enflammer,causant ainsi des blessures graves, des problèmes de
santé ou la mort.
WMISE EN GARDE
3M Occupational Health and
Environmental Safety Division
3M Center,Building 0235-02-W-70
St. Paul, MN 55144-1000
Printed in U.S.A.
3M and Air-Mate are trademarks of 3M Company.
© 2009 3M Company.All rights reserved.
3M Occupational Health
and Environmental Safety Division
3M Canada Company
P.O.Box 5757 London, Ontario N6A 4T1
Printed in U.S.A.
3M and Air-Mate are trademarks of 3M,used under license in Canada.
© 2009 3M Company.All rights reserved.
Division des produits d’hygiène
industrielle et de sécurité
environnementale de 3M
Compagnie 3M Canada
C.P.5757
London (Ontario) N6A 4T1
Imprimé aux É.-U.
3M et Air-Mate sont des marques de commerce de la Compagnie 3M, utilisées sous licence au Canada.
© 3M, 2009.Tous droits réservés.
3M México S.A. de C.V.
Av. Santa Fe No. 190
Col. Santa Fe, Del. Álvaro Obregón
México D.F.01210
Impreso en EUA.
3M y Air-Mate son marcas registradas de 3M Company.
© 2009 3M Company.Todos los derechos reservados.
3M do Brasil Ltda.
Via Anhangüera, km 110 - Sumaré - SP
CNPJ 45.985.371/0001-08
Impreso en EUA
3M e Air-Mate são marcas registradas da 3M Company.
© 2009 3M Company.Todos os direitos reservados.
WWARNING
WMISE EN GARDE
WADVERTENCIA
WADVERTÊNCIA
WMISE EN GARDE
NETTOYAGE ET ENTREPOSAGE
Suivre les politiques relatives à l’hygiène établies par son employeur pour les contaminants spécifiques auxquels on a été
exposé.
Ne pas nettoyer le respirateur à l’aide de solvants. Le nettoyage du respirateur avec des solvants peut en réduire
l’efficacité et endommager certains de ses composants. Inspecter tous les composants du respirateur avant chaque
utilisation pour s’assurer qu’il est en bon état de marche. Tout manquement à ces directives peut provoquer des
problèmes de santé ou la mort.
Nettoyage
Ne pas utiliser de solvants pour nettoyer l'ensemble souffleur du respirateur d'épuration d'air propulsé, le bloc-piles ou
les chargeurs de pile intelligents. Les solvants liquides peuvent affaiblir chimiquement le plastique.Voici la méthode de
nettoyage suggérée.
Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5 Fig. 6 Fig. 7 Fig. 8 Fig. 9 Fig. 10 Fig. 10a Fig. 11
3
Air-Mate™Belt-Mounted High Efficiency Powered Air
Purifying Respirator
User Instructions for Air-Mate™ PAPRAssembly 231-01-30, Air-Mate™ PAPR Unit 520-03-63R01,Air-MateTM
PAPR
Assembly 231-01-30U, Air-Mate™ PAPR Assembly AMH-12U, 3M™ Air-Mate PAPR Assembly AMH-1U
Important: Before use, the wearer must read and understand these User Instructions. Keep these User Instructions for
reference.
Respirateur d’épuration d’air propulsé de grand rendement
monté à la ceinture Air-Mate™
Directives d’utilisation pour l’ensemble respirateur d’épuration d’air propulsé 231-01-30 Air-Mate™, le respirateur
d’épuration d’air propulsé 520-03-63R01 Air-Mate™, l’ensemble respirateur d’épuration d’air propulsé 231-01-30U
Air-Mate™
,l’ensemble respirateur d’épuration d’air propulsé AMH-12U Air-Mate™et l’ensemble respirateur d’épuration d’air
propulsé AMH-1U Air-Mate™
Important : Avant de se servir du produit, l’utilisateur doit lire et comprendre les présentes directives d’utilisation.
Conserver ces directives à titre de référence.
Respirador Purificador de Aire Forzado de alta eficiencia,
montado en cinturón Air-Mate™
Instrucciones para el Ensamble PAPR Air-231-01-30,Unidad PAPR Air-520-03-63R01, Ensamble PAPRAir-MateTM
231-01-30U, Ensamble Air-Mate™ AMH-12U, Ensamble PAPR Air-Mate™ 3M™ AMH-1U
Importante: Antes de usar el producto, el usuario debe leer y entender estas Instrucciones. Conserve estas Instrucciones
para referencia futura.
Air-Mate™Respirador Purificador de Ar Motorizado de Alta
Eficiência Montado na Cintura
Instruções de uso para o conjunto Air-Mate™ Respirador Purificador deAr Motorizado 231-01-30, Unidade Air-Mate™
Respirador Purificador de Ar Motorizado 520-03-63R01, ConjuntoAir-Mate™ Respirador Purificador de Ar Motorizado
231-01-30U, Conjunto Air-Mate™Respirador Purificador de Ar Motorizado AMH-12U, Conjunto Air-Mate™ Respirador
Purificador de Ar Motorizado AMH-1U
Importante: Antes do uso, o usuário deve ler e entender estas Instruções de Uso. Guarde estas Instruções de Uso para
referência. 34-8704-4913-8
CV-0005-1937-7
98-0060-0030-5/4
Battery Clip
Pince pour pile Clip de la batería
Battery Terminals
Bornes du bloc-piles
Terminalesde la batería
Filter Gasket
Joint d’étanchéité
de filtre External Charging Adapter
Adaptateur de charge externe
Battery Pack
Bloc-piles Charger Power Cord
Cordon d’alimentation
du chargeur Strap 1
Courroie 1
Loop 1
Ganses 1
Loop 2
Ganses 2
Loop 3
Ganses 3
Loop 4
Ganses 4
Loop 5
Ganses 5 Strap 2
Courroie 2
Cam Lock
Verrou à came Headpiece Clip
Pince pour pièce faciale
Upper etched band
Bande gravée supérieure
Lower etched band
Bande gravée inférieure
Slot remains open
Fente ouverte
Raised ring
Anneau surélevé
Upper band 008-00-14 OK
Bande supérieure 008-00-14 OK
Lower band BE-224 OK
Bande inférieure BE-224 OK
Airflow indicator
Débitmètre
Topof connector rim.
Read flow indicator line here.
Dessus du rebord du connecteur.
Lire la ligne du débitmètre ici.
Slotted connector
Connecteur fendu
Breathing tube
Tuyaude respiration
Airflow
Débit d’air
Airflow indicator
Débitmètre
Fig. A-1
®
®
Descripción del sistema
El Ensamble de Respirador Purificador de Aire Forzado (PAPR),montado en cinturón Air-Mate™ 3M™ está diseñado
para su uso con ciertos cascos, filtros, baterías y tubos de respiración 3M para formar un sistema respiratorio completo
aprobado por el Instituto Nacional de Seguridad y Salud Ocupacional (NIOSH por sus siglas en inglés). Usados de acuerdo
con la aprobación del NIOSH, estos sistemas pueden proporcionar protección respiratoria contra ciertas partículas
contaminantes suspendidas en el aire, incluidos polvos, humos,neblinas, radionúclidos y asbestos. El Air Mate™ no provee
protección contra vapores o gases y no es un sistema intrínsicamente seguro.
La careta (cubierta de entrada respiratoria) 3M puede incluir una cubierta para la cabeza de ajuste holgado y capucha, que
sirve como cobertura para protección respiratoria para el área de nariz y boca. Remítase a la etiqueta de aprobación NIOSH
del Air-Mate 3M™ para consultar las configuraciones aprobadas.
Estos sistemas no contienen látex.
Lista de advertencias y precauciones dentro de estas Instrucciones
Descrição do Sistema
O Conjunto Air-Mate™ Respirador Purificador deAr Motorizado (PAPR) da 3M™ é feito para ser usado com certas
coberturas faciais, filtros, baterias e traquéias da 3M para formar um sistema respiratório completo aprovado pelo NIOSH e
Ministério do Trabalho(MTE). Quando usado segundo sua aprovação do NIOSH e do Ministério do Trabalho, esses sistemas
podem oferecer proteção respiratória contra determinadas contaminantes particulados transmitidos pelo ar incluindo
poeria, vapores, névoas,radionucleidos e amianto. O Air-Mate™ não oferece proteção contra certos vapores ou gases e
não é um sistema instrinsecamente seguro.
A Cobertura Facial da 3M (cobertura de entrada respiratória) inclui uma cobertura de cabeça frouxa e um capuz que
servem como uma proteção respiratória, cobrindo a área do nariz e da boca. Consulte o selo de aprovação do NIOSH para o
Air-Mate da 3M™ anexo para ver as configurações de sistema aprovadas.
Estes sistemas não contêm latex.
Lista de Advertências e Avisos Contidos nestas Instruções de Uso
ADMINISTRACIÓN DEL PROGRAMA DEL RESPIRADOR
El uso ocupacional de respiradores debe cumplir con las normas de salud y seguridad aplicables. Por ley,en Estados
Unidos el patrón deben establecer un programa de protección respiratoria por escrito que cumpla con los requerimientos
de la Norma de protección respiratoria 29 CFR 1910.134 de la Administración de Seguridad y Salud Ocupacional (OSHA por
sus siglas en inglés) y cualquier otra norma aplicable de OSHA para sustancias específicas. Para mayores informes sobre
esta norma contacte a OSHA en www.OSHA.gov.En Canadá se debe cumplir con los requerimientos de la norma CSA Z94.4
o los requisitos de la jurisdicción aplicable, según corresponda. En este documento se listan las secciones principales de
29 CFR 1910.134 como referencia. Consulte un higienista industrial o llame al Servicio Técnico 3M sobre la aplicación de
estos productos a sus requerimientos de trabajo.
Secciones principales de OSHA 29 CFR 1910.134
Sección Descripción
A Práctica permitida
B Definiciones
C Programa de protección respiratoria
D Selección de respiradores
E Evaluación médica
F PRUEBA DE AJUSTE
G Uso de respiradores
H Mantenimiento y cuidado de respiradores
I Calidad y uso del aire respirable
J Identificación de cartuchos, filtros y cánisters
K Ca pacitación e información
L Evaluación del programa
M Registro
Toda persona que use este respirador debe leer y entender la información incluida en estas Instrucciones antes de
utilizarlo. El uso de estos respiradores por personas no capacitadas ni calificadas o sin seguir estas Instrucciones puede
afectar de manera adversa el desempeño del respirador y ocasionar enfermedad o incluso la muerte.
APROBACIÓN, PRECAUCIONES Y LIMITACIONESNIOSH
Aprobación NIOSH
Para obtener un listado de componentes de sistemas respiradores PAPR Air-Mate™3M™ aprobados por el NIOSH,
consulte la etiqueta de aprobación NIOSH incluida con el producto o contacte al Servicio Técnico de EUA al
1-800-243-4630. En México llame al 01-800-712-1646 o contacte a 3M en su país.
Precauciones y limitaciones NIOSH
A – No use en atmósferas con menos de 19.5% de oxígeno.
B – No use en atmósferas inmedia tamente peligrosas para la vida o salud.
C – No exceda el uso máximo de concentraciones establecidas por las normas regulatorias.
F – No use respiradores purificadores de aire forzado si el flujo de aire es menor a 4 cfm (115 lpm) para piezas faciales
de ajuste apretado o 6 cfm (170 lpm) para capuchas y/o casco.
I – Contiene partes eléctricas que pueden provocar un incendio en atmósferas inflamables o explosivas.
J – No usar ni mantener adecuadamente este producto puede ocasionar lesiones o incluso la muerte.
L– Siga las Instrucciones del fabricante para cambiar cartuchos, cánister y/o filtros.
M – Todoslos respiradores aprobados deberán seleccionarse, ajustarse, usarse y mantenerse de acuerdo con las normas
de la Administración de Seguridad y Salud Minera (MSHA por sus siglas en inglés), OSHA y otras regulaciones
aplicables.
N – Nunca sustituya ni modifique ni agregue ni omita partes. Sólo use las partes de repuesto exactas en la configuración,
según las instrucciones del fabricante.
O – Remítase a las Instrucciones y/o al manual de mantenimiento para obtener información sobre el uso y mantenimiento
de estos respiradores.
P – El NIOSH no evalúa los respiradores para uso como mascarillas quirúrgicas.
INSTRUCCIONES DE OPERACIÓN
Armado
Tubo de respiración
Para conectar el BE-224 o el tubo de respiración anterior 008-00-14 a la unidad PAPR, introduzca el tubo (extremo macho
con sujetadores) en la unidad PAPR y gire en sentido de las manecilla del reloj para fijarlo en su lugar.Para conectar el tubo
de respiración a la careta, consulte las Instrucciones correspondientes a la careta.
Instalación de la batería
1. Quite la cubierta posterior y el filtro de la unidad PAPR.
2. Introduzca la batería en su compartimento y presiónela para que quede asentada en su lugar. Esta acción hará que las
terminales de batería engranen en la conexión en el lado de la batería (Fig. 1).
3. Deslice el clip de la batería debajo de la ranura en la caja para sujetar en su lugar.
4. Confirme que el empaque del filtro esté bien instalado en la ranura en la caja (Fig. 1).
5. Reemplace el filtro con las flechas mirando hacia la batería (Fig. 2).
6. Vuelva a colocar la cubierta posterior en su lugar.
7. Antes de su uso, cargue la batería con base en las instrucciones para carga de batería a continuación.
Carga de la Batería
1. Para usar el Cargador inteligente 3M™ coloque la estación de carga horizontalmente en una superficie plana y la
corriente AC de la estación en una conexión de regulada de 120v-60Hz.
2. El LED de luz verde se encenderá.
3. Inserte el caimán de carga en la conexión en el lado de la unidad de ventilador. Como alternativa, puede quitar la batería
de la unidad de ventilador y cargarla con el adaptador de carga externo (número de parte 520-04-24) (Fig. 3).
4. El LED se apagará, lo que inda que la batería conectada se está cargando en un modo de alto rango.
5. Después de aproximadamente ocho horas, según la cantidad de carga requerida, el LED se encenderá de nuevo, lo
que indica que el cargador a cambiado a modo de carga lenta y continua. Para cargadores canadienses, en modo de
carga lenta y continua, el LED se encenderá y apagará cada 3-5 segundos.
6. La batería Air-Mate puede ofrecer hasta 500 ciclos de carga/descarga. Sin embargo, la vida de las baterías se reducirá
de manera significativa cuando se exponen a altas temperaturas por un periodo largo.
Para maximizar la vida de la batería debe seguir las siguientes indicaciones:
– Cargue las baterías 3M™ antes de su descarga total. Puede haber algún daño si la batería no se descarga por
completo (“carga profunda”) frecuentemente.
– Las baterías 3M™ pueden cargarse cualquier momento durante el ciclo de descarga. A diferencia de algunas baterías
NiCd, la batería 3M™ no desarrolla una “memoria”.No importa si la ba tería ha sido usada 30 minutos u 8 horas,ésta
debe cargarse.
– Siempre cargue las baterías a una temperatura de 25ºC (77°F) o menos. En temperaturas más altas es posible que la
batería no acepte una carga completa. Si la batería está caliente, déjela enfriar por ½ horas antes de cargarla.
– Puede dejar las baterías en un modo de carga lenta y continua para mantener una capacidad óptima hasta por 30
días. No debe almacenar baterías conectadas al cargador por mucho tiempo. Sin una carga periódica,una ba tería
NiCd en almacenamiento pierde aproximadamente 1% de su carga cada día. Las baterías no usadas con frecuencia
deben cargarse por completo al inicio, luego se deben recargar una vez a la semana o una hora cada día para
mantener una carga completa. Es posible que las baterías sujetas a un periodo prolongado de almacenamiento (más
de 6 meses) pierdan su capacidad de mantener una carga completa. La capacidad de la batería puede revisarse al
correr la unidad de motor/ventilador PAPR por ocho horas y revisar que el flujo de aire se mantenga a 6 p3/min o más.
Varios ciclos de carga/descarga pueden restaurar la capacidad de la batería.
– En baterías usadas con poca frecuencia, debe revisarse su capacidad con regularidad al correr la unidad de motor con
ventilador PAPR y observar cuánto tiempo se mantiene el flujo de aire requerido con el indicador de flujo de aire.
– No cargue múltiples baterías en un gabinete cerrado sin ventilación.
– Para eliminar las baterías de una forma adecuada, cumpla con las regulaciones locales de eliminación de desechos
sólidos o llame a la línea de ayuda para información sobre reciclaje de baterías de la Corporación de Reciclaje de
Baterías Recargables (RBRC por sus siglas en inglés) al 1-800-8-BATTERY (1-800-822-8837).
Reemplazo de filtro y empaque del filtro
Debe cambiar el filtro de alta eficiencia (HE):
– Cuando la revisión de flujo de aire de la unidad PAPR revela que el indicador de flujo de aire no incrementa al nivel
específico (con una batería cargada adecuadamente para energizar la unidad PAPR);
– Cuando el filtro está dañado físicamente;
– Cuando el agua ha entrado al filtro de alta eficiencia, o
– Para cumplir con los procedimientos administrativos locales.
Remoción del filtro y empaque
1. Jale el cinturón a través de los sujetadores del cinturón para formar un entrelazado, transparente en la unidad PAPR
(Fig. 4).
2. Libere las lengüetas de fijación de la cubierta posterior y quite la cubierta posterior.
3. Quite y deseche el filtro de alta eficiencia y el empaque del filtro (ubicado en la ranura de soporte dentro del PAPR –
Ver Fig.1) de acuerdo con las normas locales, estatales y federales.Puede quitar el empaque con unas pinzas
(Fig. 5). Debe reemplazar los empaques cada vez que instale un filtro nuevo.
Reemplazo de filtro y empaque
1. Revise el empaque de filtro nuevo y antes de proceder asegúrese que no esté rasgado o dañado.
2. Coloque el nuevo empaque de filtro en la ranura de soporte del filtro, asegurando que el empaque esté levantado
contra los lados de la unidad PAPR, sin dejar espacios.
3. Coloque el filtro de repuesto en la unidad PAPR con las flechas mirando hacia la unidad PAPR (Fig. 2).
4. Abroche las lengüetas de fijación de la cubierta posterior en la parte posterior de la unidad PAPR.
5. Jale el cinturón a través de los sujetadores de cinturón.
Instalación de los cinturones
Cinturones 021-41-02, GVP-117, GVP-127
Enlace los cinturones como se muestra en la Fig. 6.
CINTURÓN CB-1000
1. Desabroche el seguro en la banda 2 (Fig.7).
2. Saque la banda 2 del anillo plástico en el extremo de la banda 1.
3. Jale la banda 1 hacia atrás a través de los entrelazados 3-5.
4. Inserte la banda 1 a través de la ranura del cinturón en la parte posterior de la Unidad de ventilador Airmate, luego a
través de los entrelazados 3, 4 y 5.
5. Pase la banda 2 por el anillo plástico en el extremo de la banda 1 y a través del seguro - ajuste para aflojar y asegurar
en su lugar.
Ajuste de longitud del Cinturón confort 3M™
El cinturón CB-1000 puede ajustarse en cualquier lado del broche. El CB-1000 es un cinturón de una talla y se ajustará a
tamaños de cintura desde 66 a 137 centímetros (26 a 54 pulgadas). Para cinturas menores a 86 centímetros (34 pulgadas),
saque el lado izquierdo de la banda 1 del entrelazado 1.
INSPECCIÓN
No realizar una inspección ni completar todas las reparaciones necesarias antes de usar el equipo puede afectar de
manera adversa el desempeño del respirador y ocasionar enfermedad o incluso la muerte.
Siempre se debe realizar una inspección del respirador antes de cada uso de la siguiente manera:
1. Quite la cubierta posterior y el filtro.
2. Revise que el empaque del filtro esté limpio, en buenas condiciones y bien instalado. Si no lo está, no use la unidad
PAPR hasta que el empaque de repuesto se haya instalado de acuerdo con las Instrucciones.
3. Revise si la caja del ventilador está agrietada o deformada.
4. Revise que el sujetador de batería esté bien extendido debajo del antepecho sujetador en la caja del ventilador.
5. Revise dentro de la caja del ventilador y ensamble de ventilador. Es probable que la presencia de polvo u otra partícula
dentro del ventilador indique un filtro dañado o mala colocación del filtro/cartucho en el empaque. Contacte al Servicio
Técnico de 3M para obtener ayuda.
6. Revise si el exterior de la batería está agrietado. Reemplace si hay daños.
7. Inspeccione el tubo de respiración y reemplácelo si está pinchado, agrietado o desgastado.
8. Doble el tubo para revisar si es flexible.
9. Complete de manera exitosa la revisión de desempeño.
No realizar una revisión del desempeño ni completar todas las reparaciones necesarias antes de usar el equipo puede
afectar de manera adversa el desempeño del respirador y ocasionar enfermedad o incluso la muerte.
Revisión del funcionamiento
Antes de entrar en un área contaminada debe revisar el flujo de aire para asegurarse que el sistema provea el flujo
adecuado.
1. Asegúrese que el tubo de respiración esté conectado a la unidad PAPR y el filtro HE, y que la batería totalmente
cargada estén en su lugar.
2. Confirme qué tubo de respiración se usa, el nuevo BE-224 o la versión anterior 008-00-14. En un extremo del tubo
de respiración BE-224 se encuentra una calcomanía que dice BE-224 (antes 008-00-14). La calcomanía del tubo de
respiración 008-00-14 sólo dice este número.
3. Con el indicador de flujo de aire sujetado como se indica en la Fig. 8, ubique las dos bandas circulares (superior e
inferior).
4. Tome el extremo libre del tubo de respiración debajo del anillo levantado en el conector con ranura. Asegúrese que las
ranuras en el conector estén abiertas y no estén cubiertas (Fig. 9).
5. Coloque el indicador de flujo de aire 021-14-00R01 (primero extremo punteado) en el conector con ranura. Ver la
Fig. 11.
6. Suspenda el PAPR Air-Mate 3M™ por el tubo de respiración, de modo que el tubo esté vertical sin ninguna flexión o
torsión (Fig. 10). Debe sostener el conector con ranura a nivel del ojo (Fig.10a).
7. Encienda la unidad PAPR. El indicador debe “flotar” en el aire que sale (Fig.11).
a. Tubo de respiración BE-224 (antes 008-00-14): La parte superior de la banda inferior en el indicador debe
estar en o arriba de la parte superior del borde del conector.
b. Tubo de respiración 008-00-14R01: La banda superior en el indicador debe estar en o arriba de la parte
superior del borde del conector.
Si el indicador no se levanta hasta el nivel observado con anterioridad para el tubo de respiración en uso, el flujo de aire es
insuficiente y no se debe usar el PAPR. Remítase a la sección "Solución de problemas”en las Instrucciones del Ensamble
PAPR Air Mate 3M™.
Entrada y salida del área contaminada
Antes de entrar al área contaminada, complete los procedimientos de inspección listados en estas Instrucciones.
1. Complete el armado, la inspección y la revisión del desempeño del PAPR como se describe en estas Instrucciones.
2. Complete el ensamble y ajuste de la careta del respirador de acuerdo con las Instrucciones incluidas con la careta del
respirador.
3. Coloque el cinturón con el ensamble del PAPR alrededor de la cintura y abroche el seguro.
4. Ajuste el cinturón según sea necesario para un ajuste cómodo y seguro.
5. Presione el interruptor de energía para encender el sistema y verificar que el aire fluya hacia la careta.
6. Colóquese la careta del respirador y luego entre al área contaminada.
Nota: Esta unidad PAPR y la batería no son resistentes al agua. No se deben sumergir o someter a rociado pesado con
agua u otros líquidos. Es probable que las altas concentraciones de neblina o sprays saturen los filtros y por ende se
disminuya el flujo de aire por debajo de los niveles seguros.
7. No se quite el respirador o introduzca la mano en la careta en áreas donde el aire esté contaminado.
8. Siga los procedimientos específicos de salida y descontaminación para apagar el ventilador con motor y quitarse el
respirador.
El uso del respirador en atmósferas para las cuales no ha sido diseñado ni certificado por el NIOSH puede ocasionar
enfermedad o incluso la muerte. No use este respirador donde:
- Las atmósferas contengan vapores o gases peligrosos.
- Las atmósferas sean deficientes de oxígeno.
- Las concentraciones de los contaminantes sean desconocidas.
- Las concentraciones de los contaminantes sean inmediatamente peligrosas para la vida o salud (IDLH).
- Las concentraciones de contaminantes excedan la concentración máxima de uso (MUC) determinada con el factor de
protección asignado (APF) recomendado para la careta aplicable o el APF estipulado por las normas gubernamentales
correspondientes, lo que sea menor.Consulte las Instrucciones incluidas con la careta correspondiente.
No entre a un área contaminada hasta que se haya colocado correctamente el sistema respirador.No se quite el
respirador antes de salir del área contaminada. Hacerlo puede ocasionar enfermedad o incluso la muerte.
Los contaminantes peligrosos para su salud incluyen aquellos que no puede ver u oler.Abandone el área contaminada
de inmediato si ocurre cualquiera de las siguientes condiciones. No hacerlo puede ocasionar enfermedad o incluso
la muerte.
- El flujo de aire disminuye o se detiene.
- Si se daña cualquier parte del sistema.
- Si disminuye o se detiene el flujo de aire en el respirador.
- Si se le dificulta la respiración.
- Si siente mareos o si se ve afectada su visión.
- Si percibe los contaminantes por el gusto u olfato.
- Si siente irritación en cara, ojos, nariz o boca.
- Si sospecha que la concentración de los contaminantes puede haber alcanzado los niveles en los que el respirador
ya no proporcione una protección adecuada.
No exponga el ensamble de ventilador/filtro directamente a chipas o salpicaduras de material fundido. Exponer el filtro
al contacto directo con chispas o salpicadura de metal fundido puede dañarlo y permitir el paso de aire no filtrado en
la zona de respiración, lo que puede ocasionar enfermedad o incluso la muerte, y provocar que el filtro o ventilador
se quemen, lo que causará lesiones graves, enfermedad o incluso la muerte.
Componentes, partes de repuesto 3M™
Número de producto Descripción
231-01-30 Ensamble PAPR Air-Mate™ (incluye unidad PAPR,batería, filtro, cinturón tejido e indicador de
flujo de aire)
231-01-30U EnsamblePAPR Air-Mate™ (incluye unidad PAPR, batería,filtro, cinturón de vinilo e indicador
de flujo de aire)
AMH-1U Ensamble PAPR Air-Mate™ (incluye unidad PAPR, batería,filtro, cinturón de vinilo e indicador
de flujo de aire, cargador de batería, adaptador de carga externo, tubo de respiración BE-224 y
cubiertas para tubo de respiración)
AMH-12U EnsamblePAPR Air-Mate™ (incluye ensamble PAPR, batería, filtro,cinturón de vinilo e indicador
de flujo de aire, cargador de batería, adaptador de carga externo, tubo de respiración
BE-224, cubiertas para tubo de respiración, cubierta para la cabeza BE-12-3 regular y bolsa de
almacenamiento)
520-03-63R01 Unidad PAPRAir-Mate™ (no incluye batería, cinturón e indicador de flujo de aire) (Fig. 1)
007-00-15R01 Batería
451-02-01R01 Filtrode alta eficiencia (incluye empaque)
GVP-127 Cinturón,tejido
021-41-02R01 Cinturón,nylon, 150 cm (59”)
GVP-117 Cinturón,vinilo (Deconable)
CB-1000 Cinturónconfort (para tamaños de cintura desde 66 a 132 cm (26 a 52”)
021-14-00R01 Indicador de flujo de aire - para uso con tubo de respiración BE-224
021-10-07R01 Cubierta trasera (para Unidad PAPR)
520-03-73 Cargador inteligente de batería
520-04-24 Adaptador externo de carga
BE-224 Tubo de respiración - para uso con careta serie BE
Consulte la etiqueta de aprobación de NIOSH que viene con el producto o contacte al servicio técnico de 3M para
información sobre productos adicionales como tubos de respiración, cascos e implementos para cubrir la cabeza u otros
componentes del sistema que puedan estar aprobados para uso con la unidad respiratoria Air-Mate™.
Accesorios 3M™
Número de producto Descripción
W-3228-10 Cubierta para tubo de de respiración
520-03-72 Cargadorinteligente de batería, 5 unidades
520-01-61 Cargadorinteligente de batería, 10 unidades
520-01-61SGL Cargador inteligente de batería, una unidad (Sólo Canadá)
520-01-61FIV Cargador inteligente de batería, 5 unidades (Sólo Canadá)
LOCALIZACIÓN DE AVERÍAS
Problema Causa posible Acción correctiva
Si detecta los contaminantes
por el olfato o gusto o si hay
alguna irritación.
Mal uso, ensamble incorrecto o mal
funcionamiento del equipo.
Abandone de inmediato el área de trabajo
y contacte a su supervisor.
No use la unida PAPR hasta que haya
identificado y corregido la causa.
El ventilador no corre cuando
se oprime el interruptor.
La batería está descargada.
El interruptor de energía no funciona.
El motor no funciona.
Recargue 14-16 horas.
Remplace la batería.
Remplace el ventilador con motor.
La batería no acepta la carga,
pero la unidad PAPR corre
cuando se conecta en el
cargador.
Falla en la conexión de batería o las
terminales están sucias/dañadas.
Revise que las terminales de la batería
estén limpias y que la batería esté bien
conectada y segura en la caja del PAPR.
El PAPR no pasa la prueba de
flujo de aire.
El filtro está saturado.
Necesita recargar la batería.
La batería no mantiene la carga.
El tubo de respiración está bloqueado.
Remplace el filtro.
Cargue la batería
Remplace la batería.
Ubique y quite la restricción.
WADVERTENCIA
Este producto ayuda a proteger contra ciertas partículas suspendidas en el aire. El mal uso puede ocasionar
enfermedad o incluso la muerte. Para su uso adecuado consulte a su supervisor,lea las Instrucciones, o llame a 3M
en EUA al 1-800-243-4630. En Canadá llame al Servicio Técnico al 1-800-267-4414. En México llame al
01-800-712-0646. O contacte a 3M en su país.
Toda persona que use este respirador debe leer y entender la información incluida en estas Instrucciones antes de
utilizarlo. El uso de estos respiradores por personas no capacitadas ni calificadas o sin seguir estas Instrucciones puede
afectar de manera adversa el desempeño del respirador y ocasionar enfermedad o incluso la muerte.
No use con partes o accesorios distintos a los fabricados por 3M™, como se describe en estas Instrucciones o en la
etiqueta de aprobación del NIOSH para este producto. No intente reparar o modificar ningún componente del sistema,
excepto como se describe en las Instrucciones. No hacerlo puede afectar de manera adversa el desempeño del
respirador y ocasionar enfermedad o incluso la muerte.
No realizar una inspección ni completar todas las reparaciones necesarias antes de usar el equipo puede afectar de
manera adversa el desempeño del respirador y ocasionar enfermedad o incluso la muerte.
No realizar una revisión del desempeño ni completar todas las reparaciones necesarias antes de usar el equipo puede
afectar de manera adversa el desempeño del respirador y ocasionar enfermedad o incluso la muerte.
El uso del respirador en atmósferas para las cuales no ha sido diseñado ni certificado por el NIOSH puede ocasionar
enfermedad o incluso la muerte. No use este respirador donde:
- Lasatmósferas contengan vapores o gases peligrosos.
- Lasatmósferas sean deficientes de oxígeno.
- Lasconcentraciones de los contaminantes sean desconocidas.
- Lasconcentraciones de los contaminantes sean inmediatamente peligrosas para la vida o salud (IDLH).
- Lasconcentraciones de contaminantes excedan la concentración máxima de uso (MUC por sus siglas en inglés)
determinada con el factor de protección asignado (APF por sus siglas en inglés) recomendado para la careta
aplicable o el APF estipulado por las normas gubernamentales correspondientes, lo que sea menor.Consulte las
Instrucciones incluidas con la careta correspondiente.
No entre a un área contaminada hasta que se haya colocado correctamente el sistema respirador.No se quite el
respirador antes de salir del área contaminada. Hacerlo puede ocasionar enfermedad o incluso la muerte.
Los contaminantes peligrosos para su salud incluyen aquellos que no puede ver u oler.Abandone el área contaminada
de inmediato si ocurre cualquiera de las siguientes condiciones. No hacerlo puede ocasionar enfermedad o incluso
la muerte.
- Elflujo de aire disminuye o se detiene.
- Sise daña cualquier parte del sistema.
- Sidisminuye o se detiene el flujo de aire en el respirador.
- Sise le dificulta la respiración.
- Sisiente mareos o si se ve afectada su visión.
- Sipercibe los contaminantes por el gusto u olfato.
- Sisiente irritación en cara, ojos, nariz o boca.
- Sisospecha que la concentración de los contaminantes puede haber alcanzado los niveles en los que el respirador
ya no proporcione una protección adecuada.
No exponga el ensamble de ventilador/filtro directamente a chipas o salpicaduras de material fundido. Exponer el filtro
al contacto directo con chispas o salpicadura de metal fundido puede dañarlo y permitir el paso de aire no filtrado en la
zona de respiración, lo que puede ocasionar enfermedad o incluso la muerte, y provocar que el filtro o ventilador se
quemen, lo que causará lesiones graves, enfermedad o incluso la muerte.
No limpie el respirador con solventes. Limpiar el respirador con solventes puede degradar los componentes de
éste y reducir su efectividad. Antes de cada uso,revise los componentes del respirador para asegurar las condiciones
adecuadas de funcionamiento. No hacerlo puede ocasionar enfermedad o incluso la muerte.
Nunca trate de limpiar los filtros al golpear o soplar para sacar el material acumulado. Esto puede dañar la membrana
del filtro y permitir el paso de las partículas peligrosas en la zona de respiración, y ocasionar enfermedad o incluso
la muerte.
LIMITACIONES DE USO
No use este sistema respirador para entrar a áreas donde:
• Las atmósferas sean deficientes de oxígeno.
• Las concentraciones de los contaminantes sean desconocidas.
• Las concentraciones de los contaminantes sean inmediatamente peligrosas para la vida o salud (IDLH).
• Las concentraciones de contaminantes excedan la concentración máxima de uso (MUC) determinada con el
factor de protección asignado (APF) para el sistema respirador específico o el APF estipulado por las normas
gubernamentales correspondientes, lo que sea menor.
Consulte las Instrucciones incluidas con la careta correspondiente, las limitaciones adicionales y precauciones en la
sección de Precauciones y limitaciones de NIOSH en estas Instrucciones.
WADVERTENCIA
WADVERTENCIA
WADVERTENCIA
WADVERTENCIA
WADVERTENCIA
LIMPIEZA Y ALMACENAMIENTO
Si las prácticas de higiene establecidas por su patrón para contaminantes específicos a los que ha sido expuesto.
No limpie el respirador con solventes. Limpiar el respirador con solventes puede degradar los componentes de
éste y reducir su efectividad. Antes de cada uso,revise los componentes del respirador para asegurar las condiciones
adecuadas de funcionamiento. No hacerlo puede ocasionar enfermedad o incluso la muerte.
Limpieza
No debe usar solventes para limpiar la unidad de ventilador PAPR, la batería ni el cargador inteligente de batería. Los
solventes líquidos pueden debilitar químicamente los componentes plásticos. Siga los siguientes procedimientos de
limpieza:
1. Unidad de ventilador con motor: Limpie las superficies exteriores del Ensamble PAPR Air Mate 3M™ con
un paño suave húmedo con solución de agua limpia y detergente suave con pH neutro. No sumerja en agua el
ventilador con motor Air Mate o la batería. No debe usar limpiadores abrasivos y solventes.
2. Tubo de respiración: Limpie los sitios de conexión en el tubo de respiración con una solución de agua y
detergente. Puede sumergir el tubo de respiración en agua para su limpieza.Antes de su uso o almacenamiento,
el interior del tubo debe estar totalmente seco. Seque al aire o seque al conectar la unidad Air Mate y usarla para
pasar aire a través del tubo hasta que esté seco.
3. Cinturón confort: Lave en lavadora con agua fría y un detergente suave. Seque al aire.
4. Filtros: No intente limpiar los filtros. Deseche los filtros usados. Deseche el filtro de acuerdo con las regulaciones
correspondientes.
Nunca trate de limpiar los filtros al golpear o soplar para sacar el material acumulado. Esto puede dañar la membrana
del filtro y permitir el paso de las partículas peligrosas en la zona de respiración, y ocasionar enfermedad o incluso
la muerte.
Almacenamiento
Almacene el respirador a temperatura ambiente en un área seca, protegida contra exposición de contaminantes peligrosos.
ESPECIFICACIONES
Técnicas
Resistencia al calor y la flama Este sistema respirador no está diseñado para uso en ambientes con alta temperatura
y no debe exponerse a chispas o flama.
Batería Cadmio níquel recargable.
Hasta 8 hrs de uso por carga.
Cargue las baterías a una temperatura de 25ºC (77°F) o menos.
Rango de flujo de aire Mayor a (170 lpm) 6 cfm.
Peso de PAPR Aproximadamente0.5 kg (1.1 lb).
Peso de la batería Aproximadamente 0.8 kg (1.7 lb).
Factor de protección asignado
Remítase a las Instrucciones para consultar el tipo de casco específico que debe usar para determinar el factor de
protección asignado para el Sistema PAPR Air-Mate.Consulte la Ficha Técnica #175 de 3M (www.3M.com/OccSafety) para
obtener información adicional sobre APFs y datos de prueba como soporte. En Canadá debe cumplir con los requerimientos
de la norma CSA Z94.4 de la autoridad con jurisdicción en su región.
COMPONENTES DEL SISTEMA Y PARTES DE REPUESTO
No use con partes o accesorios distintos a los fabricados por 3M™, como se describe en estas Instrucciones o en la
etiqueta de aprobación del NIOSH para este producto. No intente reparar o modificar ningún componente del sistema,
excepto como se describe en las Instrucciones. No hacerlo puede afectar de manera adversa el desempeño del
respirador y ocasionar enfermedad o incluso la muerte.
WADVERTENCIA
WADVERTENCIA
WADVERTENCIA
APÉNDICE 1
Revisión de desempeño con Indicador de flujo de aire AFI-200
1. Asegúrese que el filtro HE esté en su lugar y que la batería esté instalada y totalmente cargada. El tubo de respiración
debe desconectarse de el PAPR 3M™ Air Mate™.
2. Introduzca el AFI-200 en la salida de aire en la parte superior del PAPR Air Mate™ (Fig.A-1).
3. Encienda la unidad PAPR. Sostenga el PAPR de modo que el AFI-200 esté vertical y a nivel del ojo.
4. La pelota en el AFI-200 debe subir arriba de la línea indicada en el lado del tubo. Si la pelota sube arriba de la línea,
esto indica que el flujo de aire es suficiente.
5. Si la pelota no llega a este nivel, el flujo de aire no es suficiente. Es posible que esto sea resultado de una carga baja
de batería, saturación del filtro u otro error en el funcionamiento. Consulte la sección de “Localización de averías”.No
entre al área contaminada hasta que haya corregido el malfuncionamiento y haya pasado la prueba de flujo
de aire.
Limitación de Responsabilidades:
3M no otorga garantías, explícitas o implícitas, de comercialización o de uso para un propósito particular de este producto.
Es responsabilidad del usuario decidir sobre su uso y/o aplicación, por lo que 3M no será responsable de los posibles daños
y perjuicios derivados del uso del producto, independientemente que sean directos, indirectos,especiales, consecuenciales,
contractuales, o de cualquier otra naturaleza.
La única y exclusiva responsabilidad de 3M, en caso de que el producto resulte defectuoso, será la del reemplazo del
producto o devolución del precio de compra.
PARA OBTENER MÁS INFORMACIÓN
En Estados Unidos:
Internet: www.3M.com/occsafety
O llame a 3M en su localidad.
WADVERTÊNCIA
Este produto ajuda a proteger contra certas partículas no ar.O uso inadequado pode resultar em enfermidade ou
morte. Para obter as Instruções de Uso adequadas, consulte o supervisor, as Instruções de Uso ou ligue para a 3M nos
E.U.A., no telefone 1-800-243-4630. No Brasil ligue para 0800 0550705.
Cada pessoa que usar este respirador deve ler e compreender as informações contidas nestas Instruções de Uso,
antes da utilização do produto. O uso destes respiradores por pessoas não treinadas ou não qualificadas, ou usá-los
infringindo estas instruções, pode afetar o funcionamento do respirador e causar enfermidade ou morte.
Não utilize com peças ou acessórios não fabricados pela 3M™ conforme está descrito nestas Instruções de Uso ou
na etiqueta de aprovação do NIOSH para este respirador.Não tente consertar nem modificar nenhum componente
do sistema, a não ser conforme está descrito nestas Instruções de Uso. A não observância desta indicação pode
afetar negativamente o desempenho do respirador e provocar enfermidades ou morte.
Se não for feita uma inspeção nem forem concluídos todos os consertos necessários antes da utilização, isso poderá
afetar negativamente o desempenho do respirador e provocar enfermidade ou morte.
Se a verificação de desempenho pelo usuário falhar e todos os reparos necessários não forem executados antes da
utilização, isto poderá afetar negativamente o desempenho do respirador e resultar em enfermidade ou morte.
O uso deste respirador em atmosferas para as quais não foi certificado pelo NIOSH, ou para as quais não foi projetado
pode ocasionar enfermidades ou morte. Não use este respirador onde:
- Asatmosferas contenham vapores ou gases perigosos.
- Asatmosferas tenham deficiência de oxigênio.
- Asconcentrações de contaminantes sejam desconhecidas.
- Asconcentrações de contaminantes sejam imediatamente perigosas à vida ou à saúde (IPVS).
- Concentraçõesde contaminantes excedem a máxima concentração de uso (MCU) determinada usando o Fator
de Proteção Atribuído (FPA) recomendado para a cobertura facial aplicável ou o FPAdeterminado pelos padrões
governamentais específicos, aquele que for menor.Consulte as Instruções de Uso fornecidas com a cobertura
facial aplicável.
Não entre em uma área contaminada até que o sistema respiratório esteja adequadamente colocado. Não remova o
respirador antes de sair da área contaminada. Não seguir estas indicações pode causar enfermidade ou morte.
Os contaminantes perigosos à sua saúde incluem aqueles que você não pode ver nem cheirar.Saia imediatamente da
área contaminada se ocorrer uma das condições a seguir.Não seguir estas indicações pode causar enfermidades
ou morte.
- O fluxo de ar diminui ou para.
- Qualquer peça do sistema for danificada.
- Diminuir ou parar o fluxo de ar para o respirador.
- A respiração se tornar difícil.
- Você se sente tonto ou sua visão está obscurecida.
- Você sentir gosto ou cheiro de contaminantes.
- Se detectar irritação no rosto, nos olhos, no nariz ou na boca.
- Suspeitar que a concentração de contaminantes possa ter atingido níveis nos quais o respirador já não protege de
maneira adequada.
Não permitir exposição direta do conjunto motor/filtro para fagulhas ou respingos de metal fundido. O contato direto
com fagulhas ou com respingos de metal fundido pode danificar o filtro, permitindo a entrada de ar não filtrado na
zona de respiração, o que pode ocasionar enfermidade ou morte, bem como ocasionar a ignição do filtro ou da
caixa plastica do ventilador motorizado do Air Mate™, resultando em lesões graves,enfermidade ou morte.
Não limpe o respirador com solventes. A limpeza com solventes poderá degradar alguns componentes do respirador
e reduzir a efetividade de uso. Inspecione todos os componentes do respirador antes de cada uso, para assegurar
condições adequadas de operação. Não seguir estas indicações pode causar enfermidades ou morte.
Nunca tente limpar os filtros batendo ou soprando o material acumulado. Isto poderá resultar em danos à membrana
do filtro permitindo que partículas perigosas entrem na zona respiratória, resultando em enfermidade ou morte.
LIMITAÇÕES DE USO
Não use este sistema respiratório para entrar em áreas onde:
• As a tmosferas tenham deficiência de oxigênio.
• As concentrações de contaminantes sejam desconhecidas.
• As concentrações de contaminantes sejam imedia tamente perigosas à vida ou à saúde (IPVS).
• Concentrações de contaminantes excedem a máxima concentração de uso (MCU) determinada usando o
Fator de Proteção Atribuído (FPA) para o sistema respiratório específico ou o FPAdeterminado pelos padrões
governamentais específicos, aquele que for menor.
Consulte as Instruções de Uso fornecidas com a cabertura facial apropriado e as limitações e precauções adicionais na
seção de Limitações e Precauções do NIOSH nestas Instruções de Uso.
GERENCIAMENTO DO PROGRAMA DO RESPIRADOR
O uso ocupacional de respiradores deve estar em conformidade com os padrões de saúde e segurança aplicáveis. Antes
do uso ocupacional destes respiradores, deve ser implementado um programa de proteção respiratória por escrito, que
atenda todos os requisitos da OSHA 29 CRF 1910.134, tais como treinamento, ensaio de vedação,a valiação médica e os
requisitos da OSHA aplicáveis para substâncias. No Brasil, os requerimentos da Instrução Normativa nº 1 do Ministério do
Trabalho,de 11 de abril de 1994, devem ser completamente atendidos e/ou requerimentos de jurisdições locais que sejam
aplicáveis. Para informações adicionais sobre este padrão, entre em contato com a OSHA em www.OSHA.gov. No Brasil, os
requerimentos da Instrução Normativa nº. 1 do Ministério do Trabalho,de 11 de abril de 1994, devem ser completamente
atendidos e/ou os requerimentos de jurisdições locais que sejam aplicáveis. As principais seções do 29 CFR 1910.134 são
listadas aqui para referência. Consulte um higienista industrial qualificado, ou ligue para a assistênciaTécnica da 3M com
perguntas referentes à aplicabilidade destes produtos para seus requisitos de trabalho.
Principais Seções do 29 CFR 1910.134 da OSHA
Seção Descrição
A Prática permissível
B Definições
C Programa de Proteção Respiratória
D Seleção de Respiradores
E Avaliação Médica
F Ensaio de Vedação
G Uso de Respiradores
H Manutenção e Cuidado com Respiradores
I Qualidade do Ar Respirável e Uso
J Identificação de cartuchos, filtros e cânisters
K Treinamento e Informações
L Avaliação do Programa
M Manutenção de Registros
Cada pessoa que usar este respirador deve ler e compreender as informações contidas nestas Instruções de Uso,
antes da utilização do produto. O uso destes respiradores por pessoas não treinadas ou não qualificadas, ou usá-los
infringindo estas instruções, pode afetar o funcionamento do respirador e causar enfermidade ou morte.
APROVAÇÃO,CUIDADOS E LIMITAÇÕES DO NIOSH
Aprovação NIOSH
Para uma lista dos componentes dos sistemas respiratórios Air-Mate™ PAPRda 3M™ aprovados pelo NIOSH consulte a
etiqueta de aprovação do NIOSH incluída com o produto ou entre em contrato com o Disque Segurança da 3M no
0800-0550705.
Precauções e limitações da NIOSH
A – Não usar em atmosferas que contenham menos de 19,5% de oxigênio.
B – Não usar em atmosferas que representem um perigo imedia to para a vida ou a saúde.
C – Não ultrapassar as Concentrações Máximas de Uso estabelecidas pelas normas reguladoras.
F – Não usar os purificadores de ar motorizados se o fluxo de ar for inferior a quatro pcm (120 lpm) para máscaras com
vedação facial ou seis pcm (170 lpm) para capuzes e/ou capacetes.
I – Conténs peças elétricas que podem causar ignição em atmosferas inflamáveis ou explosivas.
J – O uso inadequado ou a má manutenção deste produto pode causar enfermidades ou morte.
L – Siga as Instruções de Uso do fabricante para trocar os cartuchos, o recipiente metálico e/ou os filtros.
M – Todos os respiradores devem ser selecionados, ensaiados em vedação, usados,e receber manutenção de acordo
com a MSHA, OSHA, Ministério doTrabalho ou outras regulamentações aplicáveis.
N – Nunca substitua, modifique, adicione, ou omita peças. Use apenas peças de substituições na configuração exata
como especificado pelo fabricante.
O – Consulte as Instruções de Uso e/ou os manuais de manutenção para informações sobre o uso e a manutenção destes
respiradores.
P – O NIOSH não avalia os respiradores para uso como máscaras cirúrgicas.
INSTRUÇÕES DE OPERAÇÃO
Montagem
Traquéia
Para conectar a traquéia BE-224 ou a mais antiga 008-00-14 à unidade PAPR, insira a traquéia (extremidade macho com
pino) na unidade PAPR e gire no sentido horário para fixar no lugar.Para conectar a traquéia na cobertura facial, consulte
as Instruções de Uso da cobertura facial adequada.
Instalação do conjunto de baterias
1. Retire a capa traseira e o filtro da unidade PAPR.
2. Coloque a bateria dentro do compartimento e pressione-o para baixo, para assentá-la no lugar. Esta ação ligará os
terminais da bateria ao soquete na lateral do conjunto da bateria.
3. Deslize o clipe da bateria por baixo da abertura no compartimento para mantê-la no lugar.
4. Confirme que o anel de vedação do filtro está instalada corretamente na ranhura no compartimento (Fig. 1).
5. Substitua o filtro com flechas apontando para o conjunto da bateria (Fig. 2).
6. Prenda a tampa traseira em seu lugar.
7. Carregue a bateria antes de usar seguindo as Instruções de Carregamento de Bateria abaixo.
Carregando a bateria
1. Para usar o Carregador de Bateria Inteligente 3M™, coloque o conjunto carregador horizontalmente em uma
superfície plana e ligue o fio de força AC do conjunto a uma fonte regulada de 120V-60Hz.
2. O indicador luminoso (LED) verde acenderá.
3. Introduza o cabo de carga no soquete na lateral da unidade da ventoinha. Alternativamente, a bateria pode ser
removida da unidade sopradora e mudada usando um adaptador de carregamento externo (peça número 520-04-24)
(Fig. 3).
4. O indicador luminoso (LED) apagará, indicando que a bateria conectada está sendo carregada na modalidade de alta
velocidade.
5. Depois de aproximadamente oito horas (dependendo da quantidade de carga requerida) o LED acenderá novamente,
indicando que a modalidade de carga mudou para a modalidade de fluxo lento e contínuo. Para carregadores
canadenses, no modo lento, a luz do LED se apagará e acenderá a cada 3 – 5 segundos.
6. A bateria do Air-Mate pode fornecer até 500 ciclos de carga/descarga. Todavia, a vida da bateria será
significativamente reduzida quando elas forem expostas à alta temperatura por um longo período de tempo.
Para prolongar a vida útil da bateria, estas instruções devem ser seguidas:
- Carregue o conjunto da bateria da 3M™ antes que esteja complemente descarregada. Uma bateria pode ser
danificada se for descarregada por completo com freqüência ("descarga total").
- Os conjuntos das baterias da 3M™ podem ser carregadas a qualquer momento durante o ciclo de descarga. Diferindo
de outras baterias NiCad (de níquel-cadmio), o conjunto de baterias da 3M™ não desenvolve uma “memória”.A
bateria pode ser carregada, não importando se foi usada durante 30 minutos ou 8 horas.
- Sempre carregue as baterias a uma temperatura de 77°F (25°C) ou menos. Em temperaturas mais elevadas, a bateria
pode não aceitar uma carga completa. Se o conjunto de baterias estiver quente, deixe-o esfriar,durante 1/2 hora
antes de carregá-lo.
- As baterias podem ser deixadas no modo de carga lenta para manter a melhor capacidade por até 30 dias. As baterias
não deve ser armazenadas por um longo tempo conectadas ao carregador.Sem uma carga periódica, uma bateria
NiCd guardada perde diariamente ao redor de 1% de sua carga. As baterias que não são usadas com freqüência
devem ser carregadas completamente, no início, e depois durante a noite uma vez por semana ou durante uma
hora todos os dias, para manter uma carga total.As baterias sujeitas a um armazenamento prolongado (mais de
6 meses) podem perder sua capacidade de reter uma carga completa. A capacidade da bateria pode ser revisada,
fazendo funcionar a unidade do motor/ventilação do sistema PAPR, durante oito horas e revisando que o fluxo de ar se
mantenha em seis CFM ou mais. Vários ciclos de carga-descarga podem restaurar a capacidade da bateria.
- Para baterias que não são usadas freqüentemente, a capacidade da bateria deve ser verificada regularmente fazendo
funcionar uma unidade da ventoinha do motor do PAPR e notando quanto tempo o fluxo de ar requerido é mantido
usando o indicador de fluxo de ar.
- Não carregue várias baterias em um armário fechado sem ventilação.
- Para descartar adequadamente o pacote de baterias, siga as regulamentações para descarte de dejetos sólidos locais,
ou ligue para o Disque Segurança 0800-0550705 para envio da bateria para 3M.
Substituição de Filtro e Anel de Vedação de Filtro
Os filtros de alta eficiência (HE) devem ser trocados:
- Quando uma verificação do fluxo de ar na unidade PAPR mostrar que o indicador de fluxo de ar não atinge o nível
especificado (com uma bateria devidamente carregada acionando a unidade PAPR);
- Quando o filtro tiver sido fisicamente danificado;
- Quando entrar água no filtro de alta eficiência;
- Para atender os procedimentos administrativos locais.
Remoção de Filtro e Anel de Vedação
1. Puxe o cinto através dos passadores para formar um arco, separado da unidade PAPR (Fig. 4).
2. Solte os prendedores da capa traseira e retire-a.
3. Remova e descarte o filtro de alta eficiência e o anel de vedação do filtro (localizada na ranhura de suporte dentro do
PAPR - veja a Fig. 1) de acordo com as diretrizes locais,estaduais, e federais. O anel de vedação deve ser removida
usando pinças (Fig. 5). Os anéis de vedação devem ser substituídos quando um novo filtro for instalado.
Substituição de Filtro e Anel de Vedação de Filtro
1. Inspecione o anel de vedação do filtro e verifique se não está rasgado nem danificado, antes de continuar.
2. Coloque o novo anel de vedação do filtro na ranhura de suporte no filtro, certificando-se de que o anel de vedação
esteja ajustado aos lados da unidade PAPR, sem deixar espaços.
3. Ajuste o filtro de reposição na unidade PAPR com as setas apontando para a unidade PAPR (Fig. 2).
4. Prenda os prendedores da tampa traseira na parte de trás da unidade PAPR.
5. Passe o cinto, através dos passadores.
Instalação dos Cinturões
Cinturões 021-41-02, GVP-117, GVP-127
Rosqueie os cinturões como mostrado na Fig. 6.
CINTURÃO CB-1000
1. Solte a trava do came na tira 2 (Fig. 7).
2. Solte a trava do ressalto na tira 2.
3. Puxe a tira 2 para fora do cinturão plástico na extremidade da tira 1.
4. Insira a tira 1 através da abertura do cinturão na parte de trás da Unidade da Ventoinha do Airmate, então através dos
laços 3, 4, e 5.
5. Passe a tira 2 através do encaixe de plástico no final da tira 1 e volte em direção da trava excêntrica— ajuste para
esticar bem as tiras e prender bem.
Ajuste do comprimento do cinturão de conforto 3M™
O cinto CB-1000 pode ser ajustada pelos dois lados da fivela com botão de pressão. O CB-1000 é um cinturão de tamanho
único e acomodará tamanhos de cintura de 66 a 137 centímetros. Para cinturas menores que 86 centímetros, coloque o
lado esquerdo da tira 1 para fora do laço 1.
INSPEÇÃO
Se não for feita uma inspeção, nem forem concluídos todos os consertos necessários antes da utilização, isso poderá
afetar negativamente o desempenho do respirador e provocar enfermidade ou morte.
Antes de cada utilização do respirador,uma inspeção deverá ser executada da seguinte forma:
1. Retire a tampa traseira e o filtro.
2. Verifique que o anel de vedação do filtro esteja limpo, em boas condições e corretamente instalado. Caso contrário,
não use o PAPR até que um anel de vedação de substituição possa ser instalado segundo estas Instruções de Uso.
3. Examine o alojamento da ventoinha quanto a rachaduras ou dobras.
4. Verifique que a trava da bateria esteja totalmente estendida por baixo da aba retentora do alojamento da ventoinha.
5. Examine a parte interna do alojamento da ventoinha e do conjunto do ventilador. A presença de pó ou outras partículas
dentro da ventoinha podem ser indicação de um filtro danificado ou de ajuste inadequado do filtro/cartucho no anel de
vedação. Entre em contato com o serviço técnico da 3M para solicitar ajuda.
6. Examine a parte externa da bateria quanto a rachaduras. Substitua se estiver danificada.
7. Verifique se a traquéia está perfurada, com fissuras ou gasta, neste caso troque-a.
8. Dobre a traquéia para verificar sua flexibilidade.
9. Termine com êxito a verificação do desempenho do usuário.
WADVERTÊNCIA
WADVERTÊNCIA
Se a verificação de desempenho pelo usuário falhar e todos os reparos necessários não forem executados antes da
utilização, isto poderá afetar negativamente o desempenho do respirador e resultar em enfermidade ou morte.
Verificação de desempenho pelo usuário
Antes da entrada em uma área contaminada uma verificação de fluxo de ar deve ser executada para garantir que o sistema
esteja fornecendo um fluxo de ar adequado.
1. Assegure-se de que a traquéia esteja conectada à unidade de PAPR e que o filtro de HE e que a bateria
completamente carregada estejam instalados.
2. Confirme qual traquéia está sendo usada, se a mais nova BE-224 ou a mais velha 008-00-14. Um adesivo em uma
extremidade da traquéia BE-224 dirá BE-224 (antes 008-00-14). O adesivo para a traquéia 008-00-14 dirá apenas
008-00-14.
3. Segurando o indicador de fluxo de ar como mostrado na Fig. 8, localize as duas faixas circulares marcadas (superior e
inferior).
4. Segure a extremidade livre da traquéia abaixo do anel levantado no conector ranhurado. Assegure-se de que as
ranhuras no conector estejam abertas e não estajam cobertas (Fig. 9).
5. Coloque o indicador de fluxo de ar 021-14-00R01 (primeiro a extremidade com ponta) no conector ranhurado. Veja a
Fig. 11.
6. Suspenda o PAPR Air-Mate da 3M™ pela traquéia para que a traquéia esteja vertical sem dobras ou torção (Fig. 10).O
conector ranhurado deve ser mantido no nível dos olhos (Fig. 10a).
7. Ligue a unidade PAPR. O indicador deve "flutuar" no ar que sai (Fig. 11).
a. Traquéia BE-224 (antes 008-00-14):O topo da marca inferior no indicador deve estar no topo da borda do
conector ou acima dela.
b. Traquéia 008-00-14R01: A marca superior no indicador deve estar no topo da borda do conector ou acima dela.
Se o indicador não subir ao nível indicado acima para a traquéia em uso, o fluxo de ar é insuficiente e o PAPR não deve ser
usado. Consulte a seção "Solução de Problemas" nas Instruções de Uso do conjunto do PAPRAir-Mate da 3M™.
Entrada e Saída de Área Contaminada
Antes de entrar na área contaminada complete os procedimentos de inspeção listados nestas Instruções de Uso.
1. Conclua a montagem, a inspeção e a verificação de desempenho do conjunto PAPR conforme descrito nestas
Instruções de Uso.
2. Complete a montagem e o ajuste da cobertura facial do respirador de acordo com as Instruções de Uso fornecidas
com a cobertura facial do respirador.
3. Coloque o cinto com o conjunto PAPR ao redor da cintura e feche a fivela.
4. Ajuste o cinto conforme o necessário e feche-o.
5. Aperte o botão para ligar o sistema e certifique-se de que haja fluxo de ar para a cobertura facial.
6. Vista a cobertura facial e entre na área contaminada.
Nota: Esta unidade PAPR e a bateria não são à prova d´água. Elas não deverão ser submersas ou submetidas a
ambientes com muita água ou outros líquidos. Altas concentrações de névoas ou respingos podem obstruir os filtros
temporariamente e fazer o fluxo de ar cair abaixo dos níveis seguros.
7. Não remova o respirador ou coloque sua mão dentro da cobertura facial em áreas onde o ar está contaminado.
8. Siga seus procedimentos de saída e descontaminação específicos para desligar a ventoinha do motor e remover o
respirador.
Não limpe o respirador com solventes. A limpeza com solventes poderá degradar alguns componentes do
respirador e reduzir a efetividade de uso. Inspecione todos os componentes do respirador antes de cada uso, para
assegurar condições adequadas de operação. Não seguir estas indicações pode causar enfermidades ou morte.
Limpeza
Não se deve usar solventes para limpar a unidade PAPR motorizada, a bateria ou os carregadores inteligentes de bateria.
Solventes podem danificar quimicamente o plástico. Use os procedimentos sugeridos a seguir para a limpeza:
1. Unidade da ventoinha do motor: Limpe as superfícies exteriores do conjunto PAPR Air-Mateda 3M™ com um
pano macio umidecido em uma solução de água e detergente suave de pH neutro. Não coloque a ventoinha do
motor ou a bateria do Air Mate na água. Não use solventes ou limpadores abrasivos.
2. Traquéia: Limpe os locias de conexão na traquéia com a solução de água e detergente.A traquéia pode ser
colocada na água para limpeza. O interior do tubo deve ser totalmente seco ante de ser usado ou armazenado.
Seque a ar ou seque conectando a unidade do Air Mate e use-a para forçar que o ar passe pelo tubo até que
seque.
3. Cinturão: Lavar à máquina em água fria e com detergente neutro. Seque a ar.
4. Filtros: Não tente limpar os filtros. Descarte os filtros usados da forma correta. Descarte o filtro seguindo as
regulamentações aplicáveis.
Nunca tente limpar os filtros batendo ou soprando o material acumulado. Isto poderá resultar em danos à membrana do
filtro permitindo que partículas perigosas entrem na zona respiratória, resultando em enfermidade ou morte.
Armazenamento
Guarde seu respirador em uma área seca, a temperatura ambiente, protegido contra a exposição a contaminantes
perigosos.
ESPECIFICAÇÕES
Técnica
Resistência a calor e a chama Este sistema respiratório não foi projetado para uso em ambientes de
altas temperaturas e não deve ser exposto a faíscas ou a chamas.
Bateria De níquel-cadmio, recarregável.
Até 8 hrs de uso em cada troca.
Troque as baterias em uma temperatura de até 25°C (77°F)
Variação do fluxo de ar Mais de 6 scfm (170 lpm)
Peso do Purificador de Ar Motorizado (PAPR) Aproximadamente 1.1 lb (0.5 kg)
Peso do conjunto de baterias Aproximadamente 1.7 lb (0.8 kg)
Fatores de proteção Atribuídos (FPA)
Consulte as Instruções de Uso para a cobertura facial específica a ser usada para determinar o fator de proteção atribuído
para o sistema de PAPR Air-Mate.Consulte o Boletim de Dados Técnicos n° 175 da 3M™ (www.3M.com/OccSafety -
Technical Data Bulletin #175) para informações adicionais sobre os FPAse os dados de teste de a poio.
COMPONENTES DO SISTEMA E PEÇAS DE REPOSIÇÃO
Não utilize com peças ou acessórios não fabricados pela 3M™ conforme está descrito nestas Instruções de Uso ou
na etiqueta de aprovação do NIOSH para este respirador.Não tente consertar nem modificar nenhum componente do
sistema, a não ser conforme está descrito nestas Instruções de Uso. A não observância desta indicação pode afetar
negativamente o desempenho do respirador e provocar enfermidades ou morte.
Componentes e Partes para Reposição da 3M™
Número do Produto Descrição
231-01-30 O Conjunto PAPR Air-Mate™ (inclui unidade PAPR,bateria, filtro, cinturão de tecido e medidor
de fluxo)
231-01-30U O Conjunto PAPR Air-Mate™ (inclui unidade PAPR,bateria, filtro, cinturão de vinil e medidor de
fluxo)
AMH-1U O Conjunto PAPR Air-Mate™ (inclui unidade PAPR,ba teria,filtro, cinturão de vinil, medidor
de fluxo, carregador inteligente de bateria, adaptador de carga externo, traquéia BE-224 e
cobertura de traquéia)
AMH-12U O Conjunto PAPR Air-Mate™ (inclui conjunto PAPR 231-01-30U,bateria, filtro, cinturão de vinil,
medidor de fluxo, carregador inteligente de bateria, adaptador de carga externo, traquéia
BE-224, coberturas de traquéia, Cobertura Facial BE-12-3 regular e sacola de armazenamento)
520-03-63R01 A Unidade PAPR Air-Mate™ (não inclui bateria, cinto e medidor de fluxo) (Fig.1)
007-00-15R01 Bateria
451-02-01R01 Filtro de Alta Eficiência (inclui anel de vedação)
GVP-127 Cinto de tecido trançado
021-41-02R01 Cinto de Nylon, 59 pol (150 cm) de comprimento
GVP-117 Cinto de vinil (descontaminável)
CB-1000 Cinto de Conforto (se adapta a cinturas de 26 – 52 pol (66 a 132 centímetros)
021-14-00R01 Indicador de fluxo de ar - para uso com a traquéia BE-224
021-10-07R01 Capa Traseira (para a unidade PAPR)
520-03-73 Carregador Inteligente de Bateria
520-04-24 Adaptador de Carga Externo
BE-224 Traquéia, para usar com o capacete da série BE
Consulte a(s) etiqueta(s) de aprovação do NIOSH fornecida com o produto ou contate o Serviço Técnico da 3M para
informações sobre todas as traquéias adicionais, coberturas faciais ou outros componentes do sistema que podem estar
aprovados para o uso com o Respirador Purificador de Ar Motorizado Air-Mate™.
Acessórios 3M™
Número do Produto Descrição
W-3228-10 Capa para Traquéia
520-03-72 Recarregador Inteligente de Bateria para 5 unidades
520-01-61 Recarregador Inteligente de Bateria para 10 unidades
520-01-61SGL Carregador Inteligente de Baterias, Uma Unidade (somente no Canadá)
520-01-61FIV Carregador Inteligente de Baterias,5 unidades (somente no Canadá)
SOLUÇÃO DE PROBLEMAS
Problema Possível causa Ação corretiva
Você sente cheiro, gosto de
contaminantes ou ocorre
uma irritação.
Uso incorreto, montagem inadequada
ou mau funcionamento do
equipamento.
Abandone a área contaminada imediatamente
e entre em contato com seu supervisor.
Não use o respirador e purificador de ar
motorizado até que a causa seja identificada
e corrigida.
Ventoinha não funciona
quando o botão está ligado.
Bateria está descarregada.
Botão com defeito.
Motor com defeito.
Carregar novamente de 14 a 16 horas.
Substitua a Bateria.
Substitua a Unidade Motorizada.
A bateria não aceita carga,
mas a unidade PAPR
funciona quando ligada ao
carregador.
Conexão incorreta da bateria, ou
terminais sujos/danificados.
Verifique que os terminais da bateria estejam
limpos e que a bateria esteja corretamente
colocada e travada no alojamento do PAPR.
Unidade purificadora de ar
motorizado fracassa no teste
de fluxo de ar.
Filtro entupido ou saturado.
Bateria precisa de recarga.
A bateria não segura a carga.
Traquéia obstruída.
Substitua filtro.
Carregue a bateria.
Substitua a bateria.
Localize e retire a obstrução.
APÊNDICE 1
Verificação de desempenho com indicador de fluxo de ar AFI-200
1. Assegure-se de que o filtro de HE esteja instalado e a bateria esteja instalada e totalmente carregada. A traquéia
deve ser desconectada do PAPR Air-Mate™da 3M™.
2. Insira o AFI-200 na saída de ar no alto do PAPR Air-Mate™ (Fig.A-1).
3. Ligue a unidade PAPR. Segure o PAPR para que o AFI-200 esteja vertical e no nível dos olhos.
4. A bola no AFI-200 deve subir acima da linha indicada no lado do tubo. Se a bola subir acima desta linha isso
indica um fluxo de ar suficiente.
5. Se a bola não subir até este nível, o fluxo de ar é insuficiente. Isto pode ser o resultado de uma carga de bateria
baixa, um filtro entupido, ou outro defeito.Consulte a seção “Solução de Problemas”. Não entre uma área
contaminada até que o defeito seja corrigido e se passe no teste de fluxo de ar.
AVISO IMPORTANTE
GARANTIA: Caso qualquer produto 3M OH&ESD apresente defeito quanto ao material, manufatura, ou não esteja em
conformidade com qualquer garantia expressa para qualquer finalidade específica, a única obrigação da 3M e seu recurso
exclusivo será, a critério da 3M, o reparo,subsituição ou reembolso do preço de compra das peças ou produtos mediante
notificação pontual a esse respeito, e comprovação de que o produto foi armazenado, mantido e utilizado de acordo com as
instruções de uso da 3M.
EXCLUSÕES À GARANTIA: ESTA GARANTIA É EXCLUSIVA E SUBSTITUI QUAISQUER GARANTIAS IMPLÍCITAS DE
COMERCIALIZAÇÃO, ADEQUAÇÃO PARAUM OBJETIVO PARTICULAR, OU OUTRAS GARANTIAS DE QUALIDADE, EXCETO
DE TÍTULO E CONTRA VIOLAÇÃO DE PATENTE.
LIMITAÇÃO DE RESPONSABILIDADE: Com exceção do que foi afirmado acima,a 3M não será responsável por qualquer
perda ou danos diretos, indiretos, incidentais,especiais ou conseqüenciais, provindos da venda ou uso errôneo dos
produtos OH&ESD da 3M, ou da falta de habilidade do usuário em usar tais produtos. OS REMÉDIOS DETERMINADOS NISTO
SÃO EXCLUSIVOS.
PARA MAIS INFORMAÇÕES
No Brasil, entre em contato:
Para outros produtos 3M:
Linha Aberta: 0800-0132333
WADVERTÊNCIA
O uso deste respirador em atmosferas para as quais não foi certificado pelo NIOSH, ou para as quais não foi projetado
pode ocasionar enfermidades ou morte. Não use este respirador onde:
- As atmosferas contenham vapores ou gases perigosos.
- As atmosferas tenham deficiência de oxigênio.
- As concentrações de contaminantes sejam desconhecidas.
- As concentrações de contaminantes sejam imediatamente perigosas à vida ou à saúde (IPVS).
- Concentrações de contaminantes excedem a máxima concentração de uso (MCU) determinada usando o Fator
de Proteção Atribuído (FPA) recomendado para o sistema respiratório específico ou o FPAdeterminado pelos
padrões governamentais específicos, aquele que for menor.Consulte as Instruções de Uso fornecidas com a
cobertura facial aplicável.
Não entre em uma área contaminada até que o sistema respiratório esteja adequadamente colocado. Não remova o
respirador antes de sair da área contaminada. Não seguir estas indicações pode causar enfermidade ou morte.
Os contaminantes perigosos à sua saúde incluem aqueles que você não pode ver nem cheirar.Saia imediatamente da
área contaminada se ocorrer uma das condições a seguir.Não seguir estas indicações pode causar enfermidades
ou morte.
- O fluxo de ar diminui ou para.
- Qualquer peça do sistema for danificada.
- Diminuir ou parar o fluxo de ar para o respirador.
- A respiração se tornar difícil.
- Você se sente tonto ou sua visão está obscurecida.
- Você sente o gosto ou o cheiro de contaminantes.
- Seu rosto, olhos, nariz,ou boca fica(m) irritado(s).
- Você suspeita que a concentração de contaminantes possa ter atingido níveis nos quais este respirador pode
não mais prover proteção adequada.
Não permitir exposição direta do conjunto motor/filtro para fagulhas ou respingos de metal fundido. O contato direto
com fagulhas ou com respingos de metal fundido pode danificar o filtro, permitindo a entrada de ar não filtrado na
zona de respiração, o que pode ocasionar enfermidade ou morte, bem como ocasionar a ignição do filtro ou da
caixa plastica do ventilador motorizado do Air Mate, resultando em lesões graves,enfermidade ou morte.
WADVERTÊNCIA
WADVERTÊNCIA
WADVERTÊNCIA
WADVERTÊNCIA
LIMPEZA E ARMAZENAGEM
Siga as práticas de higiene estabelecidas por seu empregador para os contaminantes específicos aos quais você esteja
sendo exposto.
Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5 Fig. 6 Fig. 7 Fig. 8 Fig. 9 Fig. 10 Fig. 10a Fig. 11
Clip de la batería
Clipe da Bateria
Terminalesde la batería
Terminaisda Bateria
Empaque del filtro
Anel de vedação
do filtro Adaptador externo de carga
Adaptador para Recarga Externa
Batería
Conjunto da Bateria Cable de energía del
cargador
Cabo Elétrico do
carregador
Banda 1
Tira 1
Enlace 1
Laço 1
Enlace 2
Laço 2
Enlace 3
Laço 3
Enlace 4
Laço 4
Enlace 5
Laço 5 Banda 2
Tira 2
Seguro
Travaexcêntrica Clip para pieza facial
Clipe de capacete
Banda superior grabada
Marca gravada superior
Banda inferior grabada
Marca gravada inferior
La ranura permanence abierta
Ranhura permanece aberta
Anillo levantado
Anel levantado
Banda superior 008-00-14 OK
Tira superior 008-00-14 OK
Banda inferior BE-224 OK
Tira inferior BE-224 OK
Indicador de flujo de aire
Indicador de fluxo de ar
Parte superior del borde del conector.
Lea aquí la línea del indicador de aire
Alto da borda do conector.
Leia a linha do indicador de fluxo aqui.
Conector ranurado
Conector com ranhuras
Tubode respiración
Traquéia
Flujo de aire
Fluxo de ar
Indicador de flujo de aire
Indicador de fluxo de ar
Fig. A-1
®
®

Other manuals for Air-Mate PAPR 231-01-30

1

This manual suits for next models

4

Other 3M Respiratory Product manuals

3M Versaflo TR-300 User manual

3M

3M Versaflo TR-300 User manual

3M Strap Respirator User manual

3M

3M Strap Respirator User manual

3M Adflo 35-5401-01 User manual

3M

3M Adflo 35-5401-01 User manual

3M 8210 User manual

3M

3M 8210 User manual

3M Versaflo BT-60 Series User manual

3M

3M Versaflo BT-60 Series User manual

3M 6100 User manual

3M

3M 6100 User manual

3M 9552 User manual

3M

3M 9552 User manual

3M 4082 User manual

3M

3M 4082 User manual

3M 9210+ User manual

3M

3M 9210+ User manual

3M N95 Assembly instructions

3M

3M N95 Assembly instructions

3M 8812 User manual

3M

3M 8812 User manual

3M Ultimate FX FF-401 User manual

3M

3M Ultimate FX FF-401 User manual

3M 5101 User manual

3M

3M 5101 User manual

3M 6000 User manual

3M

3M 6000 User manual

3M 8810 User manual

3M

3M 8810 User manual

3M Versaflo TR-300 User manual

3M

3M Versaflo TR-300 User manual

3M Versaflo BT-54 Installation and operation manual

3M

3M Versaflo BT-54 Installation and operation manual

3M 7501 User manual

3M

3M 7501 User manual

3M 8822 User manual

3M

3M 8822 User manual

3M GVP-1 Guide

3M

3M GVP-1 Guide

3M 9205 Plus User manual

3M

3M 9205 Plus User manual

3M 9542V User manual

3M

3M 9542V User manual

3M C300 Series Instruction Manual

3M

3M C300 Series Instruction Manual

3M Versaflo TR-300 User manual

3M

3M Versaflo TR-300 User manual

Popular Respiratory Product manuals by other brands

Bullard DC50 Series instruction sheet

Bullard

Bullard DC50 Series instruction sheet

Dräger FPS 7000 Instructions for use

Dräger

Dräger FPS 7000 Instructions for use

Kemper Autoflow XP user manual

Kemper

Kemper Autoflow XP user manual

Omron COMP A-I-R RE-C800KD Cleaning instructions

Omron

Omron COMP A-I-R RE-C800KD Cleaning instructions

Nebu-tec SaHoMa-II Instructions for use

Nebu-tec

Nebu-tec SaHoMa-II Instructions for use

MSA PremAire Cadet Escape G1 operating manual

MSA

MSA PremAire Cadet Escape G1 operating manual

Pulmodyne BiTrac Select quick start guide

Pulmodyne

Pulmodyne BiTrac Select quick start guide

BLS 2600next manual

BLS

BLS 2600next manual

Pari LC Sprint Instructions for use

Pari

Pari LC Sprint Instructions for use

Pari Vios PRO Instructions for use

Pari

Pari Vios PRO Instructions for use

cleanAIR UniMask user manual

cleanAIR

cleanAIR UniMask user manual

PNI HU200 user manual

PNI

PNI HU200 user manual

INTERSPIRO DIVATOR Series user manual

INTERSPIRO

INTERSPIRO DIVATOR Series user manual

Lumiscope LUMINEB II 5710 Operation instructions

Lumiscope

Lumiscope LUMINEB II 5710 Operation instructions

Invacare Twilight ISP2000L Large Assembly, installation and operating instructions

Invacare

Invacare Twilight ISP2000L Large Assembly, installation and operating instructions

Gima EOLO user manual

Gima

Gima EOLO user manual

PHILIPS Respironics Sami The Seal manual

PHILIPS Respironics

PHILIPS Respironics Sami The Seal manual

Suzhou Fangtian Industries FT-N040 User instructions

Suzhou Fangtian Industries

Suzhou Fangtian Industries FT-N040 User instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.