manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. 3M
  6. •
  7. Respiratory Product
  8. •
  9. 3M 8514 P2 Operating manual

3M 8514 P2 Operating manual

Other 3M Respiratory Product manuals

3M 8822 User manual

3M

3M 8822 User manual

3M 8511 User manual

3M

3M 8511 User manual

3M Versaflo TR-800 User manual

3M

3M Versaflo TR-800 User manual

3M Versaflo TR-602E User manual

3M

3M Versaflo TR-602E User manual

3M 9505+ User manual

3M

3M 9505+ User manual

3M 9552V User manual

3M

3M 9552V User manual

3M 7500 Series User manual

3M

3M 7500 Series User manual

3M Aura 9310+Gen3 User manual

3M

3M Aura 9310+Gen3 User manual

3M 4000 Series User manual

3M

3M 4000 Series User manual

3M 8822 User manual

3M

3M 8822 User manual

3M 8822 User manual

3M

3M 8822 User manual

3M 8864 User manual

3M

3M 8864 User manual

3M Secure Click User manual

3M

3M Secure Click User manual

3M 6700 User manual

3M

3M 6700 User manual

3M 6100 Instruction Manual

3M

3M 6100 Instruction Manual

3M Adflo 35-5401-01 User manual

3M

3M Adflo 35-5401-01 User manual

3M 7907S User manual

3M

3M 7907S User manual

3M Calibration Kit 529-04-48 User manual

3M

3M Calibration Kit 529-04-48 User manual

3M 9820 User manual

3M

3M 9820 User manual

3M 6000 User manual

3M

3M 6000 User manual

3M Versaflo BT-60 Series User manual

3M

3M Versaflo BT-60 Series User manual

3M Secure Click D3000 P100 Series User manual

3M

3M Secure Click D3000 P100 Series User manual

3M Air-Mate PAPR 231-01-30 User manual

3M

3M Air-Mate PAPR 231-01-30 User manual

3M 8812 User manual

3M

3M 8812 User manual

Popular Respiratory Product manuals by other brands

Dräger PSS Series Instructions for use

Dräger

Dräger PSS Series Instructions for use

ResMed MIRAGE SWIFT II 60891/1 user guide

ResMed

ResMed MIRAGE SWIFT II 60891/1 user guide

Omron COMP A-I-R NE-C801 instruction manual

Omron

Omron COMP A-I-R NE-C801 instruction manual

Ombra 63506 Instructions for use

Ombra

Ombra 63506 Instructions for use

Lotus M-9520A quick start guide

Lotus

Lotus M-9520A quick start guide

CERES nosko nebulizer kit manual

CERES

CERES nosko nebulizer kit manual

Dr.Frei NE-SM1 user manual

Dr.Frei

Dr.Frei NE-SM1 user manual

North 5400 series instruction manual

North

North 5400 series instruction manual

John Bunn Neb-u-Lite LX2 user manual

John Bunn

John Bunn Neb-u-Lite LX2 user manual

Philips Respironics EE Leak 1 AF541 Instructions for use

Philips

Philips Respironics EE Leak 1 AF541 Instructions for use

Sperian Panther Hip-Pac P9684 Series Operation manual

Sperian

Sperian Panther Hip-Pac P9684 Series Operation manual

Dräger X-plore 6570 quick start guide

Dräger

Dräger X-plore 6570 quick start guide

Respironics SideStream HS860 Instructions for use

Respironics

Respironics SideStream HS860 Instructions for use

Sundstrom SR 500 Instructions for use

Sundstrom

Sundstrom SR 500 Instructions for use

Ambu SPUR II Instructions for use

Ambu

Ambu SPUR II Instructions for use

BLS 8000 Instructions for the use

BLS

BLS 8000 Instructions for the use

Dräger saver PP Series Instructions for use

Dräger

Dräger saver PP Series Instructions for use

SATA Vision 2000 operating instructions

SATA

SATA Vision 2000 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

PRODUCT INFORMATION SHEET
3M™DisposableRespirator
8514, P2
How to contact us
3M Australia Pty Ltd
Phone 136 136
________________________________
3M Australia Pty Ltd Customer Service
Phone 1300 363 565
Fax 1800 656 222
________________________________
3M Tech Assist Hotline
Phone 1800 024 464
________________________________
World Wide Web
www.3m.com/au/ohs
________________________________
The 3M™ Disposable Respirator 8514 P2 provides lightweight,
comfortable respiratory protection against dusts, mists, welding
fumes and smokes.
An excellent choice for welding or fume
type work settings involving heat, humidity
and long periods of wear.
Features

P2 rated filter to AS/NZS1716.

Cake-resistant filter media reduces
caking of particles on filter surface.

Buckle adjustable straps help provide a
secure comfortable fit.

Carbon layer to remove nuisance
odours and ozone for greater comfort
and protection.

The cupped shape, twin strap design
and adjustable aluminium nose clip
provides a custom fit with fewer pres-
sure points and a secure face seal over
a range of face sizes.

Patented one-way valve offers easy
exhalation and cooler, drier comfort.

For use against both mechanically gen-
erated particulates and thermally gen-
erated fumes and smokes .
Time Use Limitation:

If the respirator becomes damaged,
soiled, or breathing becomes difficult,
leave the contaminated area and re-
place and refit the respirator.
Specifications

Weight: ~35g per respirator.

Meets performance requirements of AS/
NZS1716.
Applications

Welding

Bushfire fighting

Furnace work
Materials:
The following materials are used in this
product:

Nose-clip - Aluminium alloy 3003
Component Weight (%)
Al 96.7 - 99
Cu 0.05 - 0.2
Fe Max 0.7
Mn 1 - 1.5
Other, each Max 0.05
Other, total Max 0.15
Si Max 0.6
Zn Max 0.1

Straps - Heavy duty Elastic

Filter - Polypropylene & carbon

Valve - Polypropylene & Polyisoprene
Latex & Fibreglass Free
©Copyright 3M Australia Pty. Limited 2007
Neitherwholeor part ofthispublication may be reproduced without prior permission
February2007
Packaging Product Code 3M Order code
10 Respirators/box, 8 boxes/case 8514 0398651
Ordering Information
3M™DisposableRespirator
8514, P2
©Copyright 3M Australia Pty. Limited 2007
Neitherwholeor part ofthispublication may be reproduced without prior permission
February2007
PRODUCT INFORMATION SHEET
WARNING!

Respirators must not be used until your
employer has determined whether us-
age will be in accordance with manu-
facturers instructions.

The wearer must be trained in the
proper fitting and use of this product.

Failure to follow all instructions and
warnings on the use of this product
and/or failure to wear this respirator
during all times of exposure can reduce
respirator effectiveness and result in
illness or death.

All respirators should be used in accor-
dance with Australian Standard AS/
NZS 1715.

It is recommended that fit testing be con-
ducted before assigning a respirator to
an individual. If you cannot achieve a
proper fit, do not enter contaminated
areas.

Do not use with beards orother facial
hair or conditions that prevent a good
seal between the face and the sealing
surface of the respirator.
How to contact us
3M Australia Pty Ltd
Phone 136 136
________________________________
3M Australia Pty Ltd Customer Service
Phone 1300 363 565
Fax 1800 656 222
________________________________
3M Tech Assist Hotline
Phone 1800 024 464
________________________________
World Wide Web
www.3m.com/au/ohs
________________________________