manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. 3One data
  6. •
  7. Switch
  8. •
  9. 3One data IES5024-20F User manual

3One data IES5024-20F User manual

IES5024 Series
Managed Industrial Ethernet Switch
Quick Installation Guide
3onedata Co., Ltd.
Address:
3/B, Zone 1, Baiwangxin High Technology
Industrial Park, Song Bai Road, Nanshan
District, Shenzhen, 518108, China
Website:
www.3onedata.com
Tel:
+86 0755-26702688
Fax:
+86 0755-26703485
【Package Checklist】
Please check the integrity of package and accessories while
first using the switch.
1.
Industrial Ethernet switch x 1
2.
Terminal block
3.
Power line (AC products)
4.
Mounting lug
5.
Quick installation guide
6.
Foot pad
7.
Certification
8.
Warranty card
9.
CD
If any of these items are damaged or lost, please contact our
company or dealers, we will solve it ASAP.
【Product Overview】
This series of products are 24-port 100M layer 2
rack-mounted managed industrial Ethernet switches. Models
include:
Model I. IES5024 (24 100M copper ports)
Model II. IES5024-2F (22 100M copper ports + 2 100M fiber
ports)
Model III. IES5024-4F (20 100M copper ports + 4 100M fiber
ports)
Model IV. IES5024-8F (16 100M copper ports + 8 100M fiber
ports)
Model V. IES5024-12F (12 100M copper ports + 12 100M
fiber ports)
Model VI. IES5024-16F (8 100M copper ports +16 100M
fiber ports)
Model VII. IES5024-20F (4 100M copper ports + 20 100M
fiber ports)
Model VIII. IES5024-24F (24 100M fiber ports)
【Panel Design】
Front view
Rear view
Top view
Left view
Right view
1. Restore factory defaults button
2. Console port
3. Ethernet port connection indicator
4. Device running status indicator RUN
5. Power supply input status indicator PWR
6. Relay alarm status indicator ALM
7. Rack mounting lug
8. Power input terminal block
9. Relay output terminal block
10. 100M copper port
11. Ethernet port connection indicator
12. 100M fiber port
【Mounting Dimension】
Unit: mm
Attention before mounting:
Don't place or install the device in moist area or near
water, keep the relative humidity of the device
surrounding between 5%~95% without condensation.
Before power on, first confirm the supported power
supply specification to avoid over-voltage damaging the
device.
The device surface temperature is high after running,
please don't directly contact to avoid scalding.
【Installation of Rack-mounted Device】
Select the device installation location to reserve sufficient
size.
Step 1 Adopt screws to install the mounting lugs in the
device position as figure below.
Step 2 Place the device in the rack, adopt 4 screws to
install the mounting lugs on the left and right side in
the rack.
Step 3 Check and confirm the product is firmly installed on
the rack, then mounting ends.
【Rack-mounting Device Disassembling】
Step 1 Power off the device.
Step 2 Unscrew the fixing screw of mounting lug on the
rack.
Step 3 Remove the device from the rack, disassembling
ends.
【Power Supply Connection】
This series of devices provide 5 pins 5.08mm pitch terminal
blocks, power supply occupies 3 pins on the left.The power
supply has nonpolarity and anti-reverse function, the device
can be normally working after reverse connection. The pin
definition of power supply as follows:
Pin NO.
1
2
3
Definition
L/+
GND
N/-
Single power supply
This series of products supports single
power supply scheme, power supply
value range is: 100~240VAC/DC.
Dual power supply
This series of products support dual
power supply scheme and provide P1
and P2 independent power supply
systems. When one of the power supply
system fails, the device can operate
uninterruptedly and normally, which has
improved the reliability of network operation. Power supply
value range is: 100~240VAC/DC.
Notes:
Power ON operation: First insert the power supply
terminal block into the device power supply interface,
and then plug the power supply plug contact and power
on.
Power OFF operation: First unpin the power plug, and
then remove the wiring part of terminal block, please
pay attention to the operation order above.
【Relay Connection】
This series of devices provide 5 pins 5.08mm pitch terminal
blocks; power supply occupies 3 pins on the left. Relay
terminals are a pair of normally closed contacts in device
alarm relay. They are open circuit in normal non alarm state,
closed when power off. This series of single and dual power
supply products respectively support 1 or 2 channels relay
alarm output and disconnection alarm of power supply or port.
The device can be connected to alarm indicator, alarm buzzer,
or other switching value collecting device; it can timely inform
operator when alarm occurs. The pin definition of relay as
follows:
Pin NO.
4
5
Definition
R+
R-
【Checking LED Indicator】
The device provides LED indicators to monitor the device
working status with a comprehensive and simplified
troubleshooting; the function of each LED is described in the
table as below:
LED
Status
Description
PWR
ON
Power supply is connected and
running normally
OFF
Power supply is disconnected or
running abnormally.
ALM
ON
Power supply, port link alarm
OFF
Power supply, port link without alarm
RUN
ON
The device is powering on or
abnormal
OFF
The device isn't powered on or is
abnormal
Blinking
Flash 1 time per second, the device
is running normally.
Link/Act
(1-24)
ON
Ethernet port connection is active.
Blinking
Ethernet port is in network active
status
OFF
Ethernet port connection is inactive
【Logging in to WEB Interface】
This device supports WEB management and configuration.
Computer can access the device via Ethernet interface. The
way of logging in to device’s configuration interface via IE
browser is shown as below:
Step 1 Configure the IP addresses of computer and the
device to the same network segment, and the
network between them can be mutually accessed.
Step 2 Enter device’s IP address in the address bar of the
computer browser.
Step 3 Enter device’s username and password in the login
window as shown below.
Step 4 Click “OK”button to login to the WEB interface of
the device.
Note:
The default IP address of the device is “192.168.1.254”.
The default username and password of the device is
“admin”.
If the username or password is lost, user can restore it to
factory settings via device DIP switch or management
software; all modified configurations will be cleared
after restoring to factory settings, so please backup
configuration file in advance.
Please refer to user manual for specific configuration
method of logging in to WEB interface and other
configurations about network management function.
【Specification】
Panel
100M copper port
10/100Base-T(X) self-adapting
RJ45 port, half/full duplex
self-adaption, support
MDI/MDI-X self-adaption
100M fiber port
100Base-FX, optional
SC/ST/FC interface
Alarm interface
5 pins 5.08mm pitch terminal
blocks, including 2 alarm
terminal blocks. Support 1 relay
alarm output, current load
capacity is 5A@30VDC or
10A@125VAC.
Indicator
Power supply indicator, run
indicator, interface indicator,
alarm indicator
Exchange Attributes
Backplane bandwidth
12.8G
Packet buffer size
3Mbit
MAC table size
8K
Power supply
Input power supply
100~240VAC/DC, support
single or dual power supply
scheme, and 8A output
overcurrent protection
Access terminal
5 pins 5.08mm pitch terminal
blocks, including 3 pins power
supply terminal blocks
Consumption
IES5024
No-load: 7.4W@220VAC
Full-load: 10.1W@220VAC
IES5024-2F
No-load: 8.7W@220VAC
Full-load: 11.4W@220VAC
IES5024-4F
No-load: 10W@220VAC
Full-load: 12.7W@220VAC
IES5024-8F
No-load: 12.6W@220VAC
Full-load: 15.3W@220VAC
IES5024-12F
No-load: 15.2W@220VAC
Full-load: 17.9W@220VAC
IES5024-16F
No-load: 17.8W@220VAC
Full-load: 20.5W@220VAC
IES5024-20F
No-load: 19.4W@220VAC
Full-load: 20.4W@220VAC
IES5024-24F
No-load: 22W@220VAC
Full-load: 23W@220VAC
Environmental Limits
Working temperature
-40~75℃
Storage temperature
-40~75℃
Working humidity
5%~95% (no condensation)
Protection grade
IP30 (metal shell)

This manual suits for next models

8

Other 3One data Switch manuals

3One data IES618 Series User manual

3One data

3One data IES618 Series User manual

3One data IES2016-16T Series User manual

3One data

3One data IES2016-16T Series User manual

3One data ICS6420 Series User manual

3One data

3One data ICS6420 Series User manual

3One data IES618 Series User manual

3One data

3One data IES618 Series User manual

3One data IES618-4D Series User manual

3One data

3One data IES618-4D Series User manual

3One data IES206G-2GS User manual

3One data

3One data IES206G-2GS User manual

3One data IES5024-P User manual

3One data

3One data IES5024-P User manual

3One data IES205G User manual

3One data

3One data IES205G User manual

3One data IES2005 User manual

3One data

3One data IES2005 User manual

3One data IES205 Manual

3One data

3One data IES205 Manual

3One data IES716-2GS User manual

3One data

3One data IES716-2GS User manual

3One data TNS5800D Series User manual

3One data

3One data TNS5800D Series User manual

3One data IES2100SL Series User manual

3One data

3One data IES2100SL Series User manual

3One data TNS5800 Series User manual

3One data

3One data TNS5800 Series User manual

3One data SW4485I User manual

3One data

3One data SW4485I User manual

3One data IPS7112G-4GS-8POE User manual

3One data

3One data IPS7112G-4GS-8POE User manual

3One data TNS5800 Series User manual

3One data

3One data TNS5800 Series User manual

3One data IES6306 Series User manual

3One data

3One data IES6306 Series User manual

3One data ICS5530-16GS8GC6XS-2P220 User manual

3One data

3One data ICS5530-16GS8GC6XS-2P220 User manual

3One data IES6300 Series User manual

3One data

3One data IES6300 Series User manual

3One data IPS316-2GC-4POE User manual

3One data

3One data IPS316-2GC-4POE User manual

3One data TNS5500D Series User manual

3One data

3One data TNS5500D Series User manual

3One data IES6200-PN-16T4GS-2P48 User manual

3One data

3One data IES6200-PN-16T4GS-2P48 User manual

3One data SW4485 User manual

3One data

3One data SW4485 User manual

Popular Switch manuals by other brands

Holley 12-810 Installation

Holley

Holley 12-810 Installation

Vertiv Avocent MergePoint Unity Installer/user guide

Vertiv

Vertiv Avocent MergePoint Unity Installer/user guide

Sitecom AC-1002 user manual

Sitecom

Sitecom AC-1002 user manual

Pickering PXI 40-192A user manual

Pickering

Pickering PXI 40-192A user manual

Shelly PRO 1 General user and safety guide

Shelly

Shelly PRO 1 General user and safety guide

Broadcast Tools 38511 installation manual

Broadcast Tools

Broadcast Tools 38511 installation manual

Vanco HDBT8x7 manual

Vanco

Vanco HDBT8x7 manual

DRIESCHER-WEGBERG LDTM Annex to operating instructions

DRIESCHER-WEGBERG

DRIESCHER-WEGBERG LDTM Annex to operating instructions

Linksys EZXS55W - EtherFast 10/100 Workgroup Switch user guide

Linksys

Linksys EZXS55W - EtherFast 10/100 Workgroup Switch user guide

NETGEAR GS728TPv2 Hardware installation guide

NETGEAR

NETGEAR GS728TPv2 Hardware installation guide

MSTRONIC PSE-SW5G25B4-IP66 user manual

MSTRONIC

MSTRONIC PSE-SW5G25B4-IP66 user manual

Dell Force10 Z9000 manual

Dell

Dell Force10 Z9000 manual

Videosec 24FE(PoE)+2GE+2G SFP user guide

Videosec

Videosec 24FE(PoE)+2GE+2G SFP user guide

IDT 89HPES5T5 Preliminary user's manual

IDT

IDT 89HPES5T5 Preliminary user's manual

Dell PowerConnect 7048 Getting started guide

Dell

Dell PowerConnect 7048 Getting started guide

Tekvox TEK 51T-HD user manual

Tekvox

Tekvox TEK 51T-HD user manual

Versitron S72450 installation guide

Versitron

Versitron S72450 installation guide

Sonoff DIY POWR3 user manual

Sonoff

Sonoff DIY POWR3 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.