ABB M22343 Series User manual

VER:1.2 │ │ 29.07.2016
ABB-Welcome
Pos: 2/Di nA4 - Anleitung enO nline/Inhalt/KNX/D oorEntry/832 20-AP-xxx/Tit elblatt - 83220-AP-xxx - ABB @ 19\mod_1 323249806476_15. docx@ 11 1084@ @ 1
M22341-.
M22343-.
Basic 4.3" Video hands-free
indoor station
=== Ende der List ef ür Textmar keCo ver ===

ABB-Welcome
|
—2 —
Pos: 4 /Busch-Ja eger( Neustruktur)/M odul-Stru ktur/Online-Dokumen tation/Inhalts verzeichnis (--> Für alleD okumente <--)/I nhaltsverzeichnis @ 19\ mod_1320649044386_1 5.docx@ 1 09653 @ @ 1
1Safety............................................................................................................3
2Intended use..................................................................................................3
3Environment ..................................................................................................3
3.1 ABB devices.................................................................................3
4Operations.....................................................................................................5
4.1 Standard operations .....................................................................5
4.1.1 Control elements ..........................................................................5
4.2 Control actions..............................................................................8
4.2.1 Incoming call / In a call .................................................................8
4.2.2 Display & volume settings during calling.......................................9
4.2.3 Communication menu.................................................................10
4.3 Settings.......................................................................................12
4.3.1 Overview.....................................................................................12
4.3.2 Intercom call settings..................................................................13
4.3.3 Switch actuator settings..............................................................15
4.3.4 Program button settings..............................................................16
4.3.5 Auto unlock settings....................................................................17
4.3.6 OS password settings.................................................................18
4.3.7 Ringtone settings........................................................................19
4.3.8 Volume settings..........................................................................20
4.3.9 **Date and time settings.............................................................21
4.3.10 Other settings .............................................................................22
4.3.11 **History review ..........................................................................23
4.3.12 Camera List ................................................................................25
4.3.13 Language settings ......................................................................27
4.3.14 Information..................................................................................27
4.3.15 Reseting factory default..............................................................28
4.4 Cleaning .....................................................................................29
4.5 Adjusting the device....................................................................30
5Technical data.............................................................................................31
6Mounting / Installation..................................................................................32
6.1 Requirements for the electrician.................................................32
6.2 General installation instructions..................................................33
6.3 Mounting.....................................................................................34

ABB-Welcome
|
—3 —
Pos: 6 /Busch-Ja eger( Neustruktur)/M odul-Stru ktur/Online-Dokum entation/Überschrift en( --> Füralle Do kumente <--)/1. Ebene/S - T/Sicherheit @ 1 8\mod_1302612791 790_15.docx @ 103357 @ 1 @ 1
1 Safety
Pos: 7/ Busch-Jaeger (Neus truktur)/Modul-Str uktur/Online-Dokum entation/Sicherheit (--> Für alle Doku mente< --)/Warnhin weise/Sicherheit - 230 V @ 18\mod_1302606 816750_15.docx @ 103308 @ @ 1
Warning
Electric voltage!
Risk of death and fire due to electrical voltage of 100-240 V.
–Work on the 100-240V supply system may only be performed by
authorised electricians!
–Disconnect the mains power supply prior to installation and/or
disassembly!
Pos: 8 /Busch-Ja eger( Neustruktur)/M odul-Stru ktur/Online-Dokumen tation/Überschrifte n( --> Für alle Dokum ente <--)/1. Ebene/A - F/Bestimmungsg emäßer Gebrauch @ 18\mod_1302 763321316_15.doc x@ 1034 83@ 1 @ 1
2 Intended use
Pos: 9/Di nA4 - Anleitung enO nline/Inhalt/KN X/DoorEntry/832 20-AP-xxx/B estimmungsg emaesser Gebra uch- 8 3220-AP-xxx-500 @ 20\mod_1 324561168699_15.d ocx@ 1 12728 @ @ 1
The M2231x-x is an integral part of the ABB-Welcome door communication system and
operates exclusively with components from this system. The device must only be
installed in dry indoor rooms.
Pos: 10 /Busch-Jaeg er( Neustruktur)/Mo dul-Struktur/Onlin e-Dokumentation/Üb erschriften (--> Für alleD okument e<--) /1. Ebene/U -Z/U mwelt @ 18\mod_1302 614158967_15.docx @ 10 3383@ 1 @ 1
3 Environment
Pos: 11 /Busc h-Jaeg er (Neustr uktur)/Modul- Struktur/O nline-Doku mentation/U mwelt (--> Für alleD okum ente<--)/Hi nweise/Hin weis- U mwelt- Hinweis Ele ktrogeräte@ 18\m od_130276397343 4_15.docx @ 103500 @ @1
Consider the protection of the environment!
Used electric and electronic devices must not be disposed of with
domestic waste.
–The device contains valuable raw materials which can be recycled.
Therefore, dispose of the device at the appropriate collecting
depot.
Pos: 12 /DinA4 - Anleitunge n Online/Ueberschrif ten/2./ABB Gera ete@ 1 9\mod_132 3162843832_15.doc x@ 1 10875 @ 2 @ 1
3.1 ABB devices
Pos: 13 /Busc h-Jaeg er (Neustr uktur)/Modul- Struktur/O nline-Doku mentation/U mwelt (--> Für alleD okum ente<--)/Hi nweise/Hin weis- U mwelt- ABB Ele ktrogeräte@ 19\m od_1323162745839_1 5.docx @ 110867 @ @1
All packaging materials and devices from ABB bear the markings and test seals for
proper disposal. Always dispose of the packaging material and electric devices and their
components via the authorized collecting depots and disposal companies.

ABB-Welcome
|
—4 —
ABB products meet the legal requirements, in particular the laws governing electronic
and electrical devices and the REACH ordinance.
(EU-Directive 2002/96/EG WEEE and 2002/95/EG RoHS)
(EU-REACH ordinance and law for the implementation of the ordinance (EG)
No.1907/2006)

ABB-Welcome
|
—5 —
Pos: 18 /DinA4 - Anleitunge n Online/Ueberschrif ten/1./Bedienu ng@ 1 8\mod_13026 13924165_15.doc x@ 103 365 @ 1@ 1
4 Operations
Pos: 19 /DinA4 - Anleitunge n Online/Ueberschrif ten/2./Norm aler Betrieb @ 18\mod_ 1302768820965_ 15.docx @ 103540 @ 2 @ 1
4.1 Standard operations
Pos: 20 /DinA4 - Anleitunge n Online/Ueberschrif ten/3./Bedienel emente @ 20\mod_ 132326022055 9_15.docx @ 111647 @ 3 @ 1
4.1.1 Control elements
Pos: 21 /DinA4 - Anleitunge n Online/Inhalt/KN X/DoorEntry/83 220-AP-xxx/Bedieneleme nte- 83220-AP- xxx @ 18\mod_13032 12853605_15.doc x@ 103673 @ @ 1
Fig.
1
Control elements
1
3
4
5
6
7
2
8

ABB-Welcome
|
—6 —
No.
Functions
1
4.3" Color display
2
Comunication button
2A When a call is coming, press this button to activate the communication
within 30 seconds and press it again to end the call.
2B In standby mode, press this button to enter the communication menu.
If the LED flashes slowly, this means an incoming call.
If the LED illuminates,, this means that a conversation is in progress.
If the LED flashes rapidly, it means system is busy.
3
Unlock button
3A Press this button to open the door at any time.
3B Auto-unlock: the door is automatically opened after an incoming call
(Hold this button for more than 10 seconds until the backlit LED turns
on, Tthe same operation will switch off the function and LED will be
turned off ).
If the LED illuminates, this means auto-unlock.
If the LED flashes rapidly, it means that the door has been opened over the
set time (The sensor must be connected first).
4
Surveillance button
4A In standby mode, press this button to survey the default outdoor station.
4B While the display is on, press this button to the survey the next outdoor
station. (This function is available depending on the installation type)
**4C While the display is on, hold this button to take a snapshot.
4D In standby mode, if the LED flashes, press this button to display the
"History" record.
If the LED flashes slowly, this represents a notification on a missed
call.
5
Mute button
5A In standby mode, press this button to mute ringtone of the indoor
station.
5B In standby mode, hold the button to mute ringtone of all indoor stations
in the apartment.
5C When a call is coming, press this button to reject the call.
5D During the conversation, press this button to mute microphone.
The LED illuminates to indicate mute status.
6
Programmable button 1
6A Release the lock connected with an outdoor station (COM-NC-NO)

ABB-Welcome
|
—7 —
(default function).
6B In standby mode, hold this button for 3 seconds to send SOS alarm to
the guard unit. If LED flashes slowy, it means success; and if flashes
rapidly, it means failure.
6C *Programmable button for additional functions, e.g. call to guard unit,
intercom.....
7
System setting button
Enter the system setting menu for various functions of the device.
If the LED flashes rapidly, it means that setting is busy.
8
**Induction loop function
* For use of those buttons, please contact your electrical installer.
** The function is only available in M22343-.
Induction loop function
This function is available for hearing-impaired persons wearing a hearing aid to hear the
person speaking from the outdoor station or from other indoor stations during an intercom call.
The device is able to interface hearing aids with "T" function at a distance of around 35 cm.
Pos: 22 /Busch-J aeger (Neustru ktur)/Modul-Struktur /Online-Doku mentation/Steu ermodule - Onli ne-Dokumentation (--> F üralle Do kumente <--)/+++++ +++++++ Seitenum bruch++ +++++++ +++ @ 9\mod _1268898668 093_0.docx @ 5 2149@ @ 1
max 35 cm

ABB-Welcome
|
—8 —
Pos: 26 /DinA4 - Anleitunge n Online/Ueberschrif ten/2./Bediena ktionen @ 20\mod_1 323262294281_1 5.docx @ 111911 @ 2 @ 1
4.2 Control actions
Pos: 27 /DinA4 - Anleitunge n Online/Ueberschrif ten/3./Sprech- und Vid eoverbindung @ 20\m od_132326236 8700_15.docx @ 1119 27@ 3 @ 1
4.2.1 Incoming call / In a call
Pos: 28 /DinA4 - Anleitunge n Online/Inhalt/KN X/DoorEntry/83 220-AP-xxx/Sprech- und Videoverbindung - 83220-AP- xxx @ 20\mod_13232623 41852_15.docx @ 111919 @ @ 1
Fig.
2
Incoming call / in a call
During calls, the following functions are available:
No.
Functions
1
Press this button to accept the incoming call; In a call, press this button to
end the call.
2
Press this button to open the door where the call is from.
3-A
Press this button to survey the analog camera of the outdoor station if
there is one.
3-B
Hold this button to take a snapshot.
4
Press this button to mute the ringtone of an incoming call; in a call, press
this button to mute the microphone.
5-A
Press this button to activate the function of the programmable button.
5-B
If the function "release 2nd-lock" or "control switch actuator" is assigned to
The programmable button, press this button to activate the function.
6-A
6-B
Press this button to enable or disable the full-screen function.
Hold this button to enter the brightness and volume setttings menu.
7
Time left of the connection.
8
Number of outdoor stations
Pos: 29 /Busch-J aeger (Neustru ktur)/Modul-Struktur /Online-Doku mentation/Steu ermodule - Onli ne-Dokumentation (--> F üralle Do kumente <--)/+++++ +++++++ Seitenumbruch ++++++ ++++++ @ 9\mod_1268 898668093_0.doc x@ 52149 @ @ 1
30s
Outdoor 1
1
3
6
7
8
2
4
5

ABB-Welcome
|
—9 —
Pos: 30 /DinA4 - Anleitunge n Online/Ueberschrif ten/3./Tuer oeff nen @ 20\mod_132326 3277453_15.doc x@ 1 11935 @ 3 @ 1
4.2.2 Display & volume settings during calling
Pos: 31 /DinA4 - Anleitunge n Online/Inhalt/KN X/DoorEntry/83 220-AP-xxx/Tuer oeffnen - 832 20-AP-xxx @ 20\m od_1323267958479_15. docx @ 112109 @ @1
Fig.
3
Display & volume settings during calling
Hold button for 3s to enter the display & volume setttings menu during a call or
conversation, the following functions are available.
No.
Functions
1
Navigation buttons ( up / down / confirm / cancel, etc)
2
Press the navigation buttons as needed.
3
Speech volume(only can be adjusted during conversation)
4
Saturation
5
Brightness
6
Value set
Pos: 32 /Busch-J aeger (Neustru ktur)/Modul-Struktur /Online-Doku mentation/Steu ermodule - Onli ne-Dokumentation (--> F üralle Do kumente <--)/+++++ +++++++ Seitenumbruch +++++++ +++++ @ 9\mod_1268 898668093_0.doc x@ 52149 @ @ 1
120s
Outdoor 1
2
4
5
6
1
2
3

ABB-Welcome
|
—10 —
Pos: 33 /DinA4 - Anleitunge n Online/Ueberschrif ten/3./Stumm sch alten @ 20\mod_13 23263607142_15. docx @ 111951 @ 3 @ 1
Pos: 66 /Busch-J aeger (Neustru ktur)/Modul-Struktur /Online-Doku mentation/Steu ermodule - Online-D okumentation (--> F üralle Do kumente <--)/++++++ ++++++ Seitenumbruch ++++++++ ++++ @ 9\mod_12688 98668093_0.docx @ 52149 @ @ 1
4.2.3 Communication menu
Pos: 31 /DinA4 - Anl eitungen Online/Inhalt/ KNX/DoorEntry/8 3220-AP-xxx/Tuer oeffne n- 83220-AP-xxx @ 20\mod_ 1323267958479_15.d ocx@ 112 109 @ @ 1
4.2.3.1 Overview
Press button to enter the communication menu. The following functions are available:
No.
Functions
1
Intercom call
-Touch the existing call list to make an intercom call .
2
Call to guard unit
-Call guard unit directly.
3
Broadcast
-Enable the broadcast function in this menu.
4
Swtich actuator
-Activate the existing actuator list
4.2.3.2 Intercom call
Fig.
4
: Intercom call
Set intercom call lists in the “System settings-intercom settings“ menu first.
After chosing a list, press button√to make the call.
INTERCOM CALL
Intercom 1
(001)
Intercom 2

ABB-Welcome
|
—11 —
4.2.3.3 Call to guard unit
Fig.
5
: Call to guard unit
4.2.3.4 Switch actuator
Fig.
6
: Switch actuator
Set the actuator list in the “system settings-switch actuator“ menu first.
After chosing a list, press button √to enable the lock or light which is connected with the
switch actuator.
CALL GUARD UNIT
Call Guard Unit
SWITCH ACTUATOR
Actuator 1
(001)

ABB-Welcome
|
—12 —
4.3 Settings
4.3.1 Overview
Press button to enter the system settings menu. The following functions are available:
No.
Functions
1
Intercom settings
-Set intercom lists among different apartments or within the same
apartment
2
Switch actuator
-Set the actuator list in this menu
3
Program button
-Set functions for programmable buttons
4
Auto unlock
-Set the automatic unlock time range
5
Set OS password
-Set a customized door open password, which is available together with
a keypad at an outdoor station.
6
Ringtone
-Set the ringtone for outdoor bells, indoor bell or others
7
Volume
-Set ringtone volumes
8
Date and time
-Set different times.
9
Other settings
-Other settings, e.g. auto full screen
10
History
-View all communication entries in the menu, e.g. received calls, missed
calls,
11
Language
-Set the local language
12
Information
13
Reset factory default
Pos: 27 /DinA4 - Anleitunge n Online/Ueberschrif ten/3./Sprech- und Vid eoverbindung @ 20\m od_132326236 8700_15.docx @ 1119 27@ 3 @ 1

ABB-Welcome
|
—13 —
4.3.2 Intercom call settings
Fig.
7
: intercom settings menu
No.
Functions
1
Choose the previous selection or scroll up
2
Choose the next selection or scroll down
3
Confirm the selection you choose or enter to edit it
4
Return to the previous screen
5
Add a new intercom list . In total, up to 32 intercom lists can be added.
6
Existing intercom list: Press button √to modify the settings.
means an external intercom from different
apartments.
*For establishing an external intercom, each apartment must have a master
indoor station.
7
Existing intercom list: Press button √to modify the settings.
means an internal intercom in the same
apartment.
1
2
3
6
4
Intercom 1
(001)
Intercom 2
Add New
5

ABB-Welcome
|
—14 —
Add a new list
Fig.
8
: Add a new intercom
No.
Functions
1
Enter to choose the call type :
-an external intercom means a call from different apartments
-an internal intercom means a call within the same apartment
2
Enter to change the target address, from 001 to 250.
*If the call type is the internal intercom, there is no need to set the target
address.
3
Rename the intercom list:
Scroll through letters of the alphabet or numbers one by one with “+” or
“-” button
After setting, press “Save” for confirmation.
1
Call Type
External Intercom
Target Address
Rename
3
INTERCOM
001
mike
Save
Cancel
2

ABB-Welcome
|
—15 —
4.3.3 Switch actuator settings
Fig.
9
: Switch actuator settings
No.
Functions
1
Existing switch actuator list: Press button √to modify the settings.
2
Add a new actuator list:Totally, up to 10 switch actuator lists can be added.
3
Enter to change target address with “+” or “-” button from 001 to 199.
4
Rename the switch actuator list:
Scroll through letters of the alphabet or numbers one by one with “+” or
“-” button
3
4
SWITCH ACTUATOR
Actuator 1
(001)
Add New
Target Address
Rename
002
light
Save
Cancel
SWITCH ACTUATOR
2
1
Add a new list

ABB-Welcome
|
—16 —
4.3.4 Program button settings
Fig.
10
: Program button settings
No.
Functions
1
Set functions for the program button, e.g. releasing 2nd-lock, calling guard
unit, intercom call, enabling the switch actuator.
*2nd-lock means the lock is connected with an outdoor station (NC-NO-
COM)
*Only the existing intercom call list & switch actuator list can be assigned
to the program button.
Button 1
Release 2nd-Lock
PROGRAM BUTTON
1

ABB-Welcome
|
—17 —
4.3.5 Auto unlock settings
Fig.
11
: Auto unlock settings
No.
Functions
1
Enable/disable the auto unlock function.
2
Enable/disable the auto unlock during Time 1.
3
Set starting time and ending time for Time 1
4
Enable/disable auto unlock during Time 2.
5
Set starting time and ending time for Time 2.
*If you activate the auto unlock function without setting exact working time, this function will be
available for 10 hours.
*If the auto unlock function is activated, the call forward function will be disabled.
*The function only can be set in master indoor station.
.
1
Auto Unlock
Time 1
2
AUTO UNLOCK
√
√
08
00
17
00
:
:
Time 2
X
00
00
00
00
:
:
4
3
5

ABB-Welcome
|
—18 —
4.3.6 OS password settings
Fig.
12
: OS password settings
No.
Functions
1
Enable/disable the password functions
2
Enter the password as you wish in 3~8 digits.
*only available with the keypad.
*The function only can be set in the master indoor station.
1
Enable Password
Enter Password
(3-8 digits)
SET OS PASSWORD
√
12345678
2

ABB-Welcome
|
—19 —
4.3.7 Ringtone settings
Fig.
13
: Ringtone
No.
Functions
1
Select the bell sound for the default outdoor station.
2
Select the bell sound for other outdoor stations.
3
Select the bell sound for the apartment door.
4
Select the bell sound for others, e.g.a call from the guard unit, or an
intercom call from other apartments.
1
Default Outdoor
Other Outdoors
RING TONE
Ring Tone 1
Ring Tone 2
2
Doorbell
Ring Tone 3
Others
Ring Tone 4
3
4

ABB-Welcome
|
—20 —
4.3.8 Volume settings
Fig.
14
: Volume settings
No.
Functions
1
Set the volume of bell sound.
2
Enable/disable the feedback tone which sounds when the touch button is
pressed.
3
The ringtone can be set fixed or cycled.
1
Ringtone Volume
Touchbutton Tone
VOLUME
Volume 3
2
√
Repeated Tone
√
3
This manual suits for next models
3
Table of contents
Other ABB Intercom System manuals

ABB
ABB 83210-AP 500 Series User manual

ABB
ABB H8138.K Series User manual

ABB
ABB 83210-AP 500 Series User manual

ABB
ABB Welcome M2233 Series User manual

ABB
ABB Welcome User manual

ABB
ABB M2231 SERIES User manual

ABB
ABB Welcome M22344-W User manual

ABB
ABB DP7-S-611 User manual

ABB
ABB Welcome IP User manual

ABB
ABB M2304 User manual

ABB
ABB WelcomeTouch 83220-SM 500 Series User manual

ABB
ABB 2Line User manual

ABB
ABB M22341 Series User manual

ABB
ABB Welcome M21311P1-A User manual

ABB
ABB H81402FR Series User manual

ABB
ABB H8137xPx-S User manual

ABB
ABB M22311 Series User manual

ABB
ABB Welcome IP HSM36-GU User manual

ABB
ABB ABB-Welcome M2240-W User manual

ABB
ABB Welcome User manual