ABB 83210-AP-xxx-500 User manual

VER:1.0 │ │ 01.12.2015
ABB-Welcome
Pos: 2 /DinA4 - Anleit ungen O nline/Inhalt/KNX/D oorEntry/83220- AP-xxx/Tit elblatt - 83220-AP-xxx - ABB @ 19\mod_13 23249806476_15.doc x@ 11 1084 @ @ 1
83210-AP-xxx-500
Audio hands-free Indoor
station
=== Ende der List ef ürT extmar ke Cover ===

ABB-Welcome
|
—2 —
Pos: 4 /Busch-J aeger (Neustru ktur)/Modul-Str uktur/Online-Doku mentation/Inhal tsverzeichnis (--> Für alle Doku mente< --)/Inhaltsverz eichnis @ 19\mod_1320649 044386_15.docx @ 109653 @ @ 1
1Safety............................................................................................................3
2Intended use..................................................................................................3
3Environment ..................................................................................................3
3.1 ABB devices.................................................................................3
4Operations.....................................................................................................5
4.1 Standard operations .....................................................................5
4.1.1 Control elements ..........................................................................5
4.2 Setting ..........................................................................................7
4.2.1 Set Indoor station address (X200, X100)......................................7
4.2.2 Set function of light button............................................................7
4.2.3 Set ringtone type ..........................................................................8
4.2.4 Set repeated ringtone...................................................................8
4.2.5 Set ringtone volume......................................................................8
4.2.6 Set speech volume.......................................................................8
4.3 Adjusting the device......................................................................9
5Technical data.............................................................................................10
6Mounting / Installation..................................................................................11
6.1Requirements for the electrician.................................................11
6.2 General installation instructions..................................................12
6.3 Mounting.....................................................................................13

ABB-Welcome
|
—3 —
Pos: 6 /Busch-J aeger (Neustru ktur)/Modul-Str uktur/Online-Doku mentation/Übers chriften (--> Für alle Doku mente <--)/1. Ebene/S - T/Sicherheit @ 18\ mod_13 02612791 790_15.docx @ 103357 @ 1 @ 1
1 Safety
Pos: 7 /Busch-Jaeger (Ne ustruktur)/Modul-Str uktur/Online-Doku mentation/Sicherh eit( -->F ürall e Doku mente<--) /Warnhinweise/Sich erheit - 230 V @ 18\mod_ 13026068 16750_15.docx @ 103308 @ @ 1
Warning
Electric voltage!
Risk of death and fire due to electrical voltage of 100-240 V.
–Work on the 100-240V supply system may only be performed by
authorised electricians!
–Disconnect the mains power supply prior to installation and/or
disassembly!
Pos: 8 /Busch-J aeger (Neustru ktur)/Modul-Str uktur/Online-Doku mentation/Überschrift en (--> Für alle Doku mente <--)/1. Ebene/A - F/Bestimmungsg emäßer Gebrauc h @ 18\mod_1 302763321316_1 5.docx @ 103483 @ 1 @ 1
2 Intended use
Pos: 9 /DinA4 - Anleit ungen O nline/Inhalt/KNX/D oorEntry/832 20-AP- xxx/Bestim mungsgemaess erG ebrauch - 83 220-AP-xxx-500 @ 20\mod_1324 561168699_15.docx @ 1127 28@ @ 1
This device is an integral part of the ABB-Welcome door communication system and
operates exclusively with components from this system. The device must only be
installed in dry indoor rooms.
Pos: 10 /Busch-J aeger (Neustru ktur)/Modul- Struktur/Onlin e-Dokumentation/Üb erschriften (--> Für alleD okumente <--)/1 . Ebene/U - Z/Umw elt @ 18\mod_1 302614 158967_15.docx @ 103383 @ 1 @ 1
3 Environment
Pos: 11 /B usch-J aeger (Ne ustruktur)/Mo dul-Struktur /Online-Do kumentation/U mwelt (--> Für alle Doku mente< --)/Hinweise/Hi nweis -U mwelt -H inweis Elektrogeräte @ 18\mod_1302 76397343 4_15.docx @ 103500 @ @ 1
Consider the protection of the environment!
Used electric and electronic devices must not be disposed of with
domestic waste.
–The device contains valuable raw materials which can be
recycled. Therefore, dispose of the device at the appropriate
collecting depot.
Pos: 12 /DinA4 - Anl eitungen Online/Ueb erschriften/2./ABB G eraete @ 19\mod_13 23162843832_ 15.docx @ 110875 @ 2 @ 1
3.1 ABB devices
Pos: 13 /B usch-J aeger (Ne ustruktur)/Mo dul-Struktur /Online-Do kumentation/U mwelt (--> Für alle Doku mente< --)/Hinweise/Hi nweis -U mwelt -A BBEl ektrogeräte@ 1 9\mod_13231627 45839_15.docx @ 110867 @ @ 1
All packaging materials and devices from ABB bear the markings and test seals for
proper disposal. Always dispose of the packaging material and electric devices and their
components via the authorized collecting depots and disposal companies.

ABB-Welcome
|
—4 —
ABB products meet the legal requirements, in particular the laws governing electronic
and electrical devices and the REACH ordinance.
(EU-Directive 2002/96/EG WEEE and 2002/95/EG RoHS)
(EU-REACH ordinance and law for the implementation of the ordinance (EG)
No.1907/2006)

ABB-Welcome
|
—5 —
Pos: 18 /DinA4 - Anl eitungen Online/Ueb erschriften/1./Bedi enung @ 18\mod_ 1302613924165_15. docx @ 103365 @ 1 @ 1
4 Operations
Pos: 19 /DinA4 - Anl eitungen Online/Ueb erschriften/2./Nor maler Betrieb @ 18\m od_13027688209 65_15.docx @ 103540 @ 2 @ 1
4.1 Standard operations
Pos: 20 /DinA4 - Anl eitungen Online/Ueb erschriften/3./Bedi enelemente @ 20\mo d_132326022 0559_15.docx @ 1116 47@ 3 @ 1
4.1.1 Control elements
Pos: 21 /DinA4 - Anl eitungen Online/Inhalt/ KNX/DoorEntry/8 3220-AP-xxx/Bedienelem ente- 832 20-AP- xxx@ 1 8\mod_13032128 53605_15. docx @ 103673 @ @ 1
Fig.
1
Control elements
1
3
4
2

ABB-Welcome
|
—6 —
No.
Functions
1
Comunication button
1A When a call is coming, press this button to activate the communication
within 30 seconds and press it again to end the call.
1B In standby mode, press this button to enter the communication menu.
2
Unlock button
2A Press this button to open the door at any time.
2B Auto-unlock: the door is automatically opened after an incoming call
(Hold this button for more than 10 seconds until the backlit LED turns
on, Tthe same operation will switch off the function and LED will be
turned off ).
3
Light button
3A Switch the lighting (default function)
3B Long press for 3s to enter setting mode for additional functions, e.g.
call to Guard unit, Room to romm intercom and open the 2nd lock
4
Mute button
4A In standby mode, press this button to mute ringtone of the indoor
station.
4B In standby mode, hold the button to mute ringtone of all indoor stations
in the apartment.
4C When a call is coming, press this button to reject the call.
4D During the conversation, press this button to mute microphone.
The LED illuminates to indicate mute status.
Pos: 22 /Busch-J aeger (Neustr uktur)/Modul-Stru ktur/Online-Do kumentation/Ste uermodule - Onli ne-Dokumentatio n(--> F ür alle Do kume nte< --)/+++++++ +++++ Seitenumbruch +++++++++ +++ @ 9\mod_1268898668 093_0.docx @ 52149 @ @ 1

ABB-Welcome
|
—7 —
Pos: 26 /DinA4 - Anl eitungen Online/Ueb erschriften/2./Bedi enaktionen @ 20\ mod_132326229428 1_15.docx @ 111911 @ 2 @ 1
4.2 Setting
Pos: 27 /DinA4 - Anl eitungen Online/Ueb erschriften/3./Sprec h- und Videoverbin dung @ 20\mod_132 3262368700_15.doc x@ 1 11927 @ 3 @ 1
4.2.1 Set Indoor station address (X200, X100)
Pos: 28 /DinA4 - Anl eitungen Online/Inhalt/ KNX/DoorEntry/8 3220-AP-xxx/Sprech- und Videoverbindung - 83220-AP- xxx@ 2 0\mod_ 1323262341852_15.d ocx @ 111919 @ @ 1
Step1: hold "light" button for 3s to enter setting mode (4 LEDs are on)
Step2: hold "talk" button for 3s to enter the setting of X200/X100.
Step3: press "mute" button to change the number.
The value is indicated by LED of each button.(Default value =0)
Led "talk" flashes, 0xx;
Led "unlock" flashes, 1xx;
Led "light" flashes, 2xx;
Step4: hold "light" button for 3s to enter setting mode (4 LEDs are off)
4.2.2 Set function of light button
Step1: hold "light" button for 3s to enter setting mode (4 LEDs are on)
Step2: hold "unlock" button for 3s to enter the setting of light button.
Step3: press "mute" button to change the function.
The value is indicated by LED of each button.(Default value =0)
Led "Talk" flashes, switching the lighting;
Led "Unlock" flashes, opening the 2nd lock
Led "Light" flashes, room to room intercom
Led "Mute" flashes, call Guard unit
Step4: hold "light" button for 3s to enter setting mode (4 LEDs are off)
024
124
224
24

ABB-Welcome
|
—8 —
4.2.3 Set ringtone type
Step1: hold "light" button for 3s to enter setting mode (4 LEDs are on)
Step2: press button like below to change ringtone.
press "Unlock" button to set ringtone type of door bell.
press "Light" button to set ringtone type of room to room intercom or call Guard unit
press "Mute" button to set ringtone type of Outdoor station or Gate station
Step3: hold "light" button for 3s to enter setting mode (4 LEDs are off)
4.2.4 Set repeated ringtone
Step1: hold "light" button for 3s to enter setting mode (4 LEDs are on)
Step2: hold "mute" button for 3s to repeat the ringtone or not.
Pos: 67 /DinA4 - Anleitungen Online /Ueberschriften/2./Rei nigung @ 19\mod_1310 733980 533_15.docx @ 107853 @ 2 @ 1
Step3: hold "light" button for 3s to enter setting mode (4 LEDs are off)
4.2.5 Set ringtone volume
Step1: hold "light" button for 3s to enter setting mode (4 LEDs are on)
Step2: press "talk" button to enter the ringtone volume setting
Step3: press "mute" button to adjust the ringtone volume
Pos: 67 /DinA4 - Anleitungen Online /Ueberschriften/2./Rei nigung @ 19\mod_1310 733980 533_15.docx @ 107853 @ 2 @ 1
Step4: hold "light" button for 3s to enter setting mode (4 LEDs are off)
4.2.6 Set speech volume
The setting must be under the communication
for 3s to enter setting mode (LED flashes)Step1: hold "light" button
Step2: press "light" button to adjust the volume
Pos: 67 /DinA4 - Anleitungen Online /Ueberschriften/2./Rei nigung @ 19\mod_1310 733980 533_15.docx @ 107853 @ 2 @ 1
Pos: 67 /DinA4 - Anleitungen Online /Ueberschriften/2./Rei nigung @ 19\mod_1310 733980 533_15.docx @ 107853 @ 2 @ 1
Step3: hold "light" button for 3s to enter setting mode
69 /Busch-J aeg er( Neustruktur)/Mo dul-Struktur/O nline-Dokumentati on/Steuermo dule- Online-D okumentation (--> Für alle Dokume nte< --)/+++++++ +++++ Seitenumbruch +++++++++ +++ @ 9\mod_12688 98668093 _0.docx @ 52149 @ @ 1

ABB-Welcome
|
—9 —
Pos: 70 /DinA4 - Anl eitungen Online/Ueb erschriften/2./Gera eteeinstellungen @ 18\ mod_130276 8847744_15.doc x@ 1 03548 @ 2 @ 1
4.3 Adjusting the device
Pos: 71 /DinA4 - Anl eitungen Online/Ueb erschriften/3./Absc hlusswiderstand @ 19\m od_132195807 9906_15.docx @ 1100 83@ 3 @ 1
Pos: 72 /DinA4 - Anl eitungen Online/Inhalt/ KNX/DoorEntry/B edienung/Abschl usswiderstand setze n 83220-AP- xxx@ 19\ mod_131072339 2369_15.docx @ 107841 @ @ 1
Fig.
2
:
Pos: 74 /DinA4 - Anl eitungen Online/Inhalt/ KNX/DoorEntry/B edienung/Mast er/Slave Schalter setz en8 3220-AP-xxx @ 19\mod_1310 72332096 6_15.docx @ 107833 @ @
1. Station
Selector switch to set the address of default outdoor station.
2. X10 X1
Selector switches to set the address (tens and units digits) of the indoor station.
X100 X200
Set through “light” button.
3. Master /Slave function
Only one indoor station in each apartment must be set as "Master" (Switch should
be set as 'M/S on'). All additional indoor stations in the same apartment must be
set as "Slave" (Switch should be set as 'M/S off').
4. Terminal resistor
In video installations or mixed audio and video installations, the Switch must be
set as 'RC on' on the last device of the line.
5. a b = Bus connection
= Door bell connection
Pos: 75 /Busch-J aeger (Neustr uktur)/Modul-Stru ktur/Online-Do kumentation/Ste uermodule - Onli ne-Dokument ation(--> F ür alle Do kumente <--)/+++++ +++++++ Seitenumbruc h++ +++++++ +++ @ 9\mod _1268898668 093_0.docx @ 5 2149@ @ 1

ABB-Welcome
|
—10 —
Pos: 76 /DinA4 - Anl eitungen Online/Ueb erschriften/1./Tech nischeD aten @ 18\mo d_130261586 3001_15.docx @ 1034 16@ 1 @ 1
5 Technical data
Pos: 77 /DinA4 - Anl eitungen Online/Inhalt/ KNX/DoorEntry/8 3220-AP-xxx/Technische Date n- 83220-AP-xxx @ 18\mod_13 032128 54559_15.docx @ 103705 @ @ 1
Designation
Value
Operating temperature
-10°C - +55°C
Storage temperature
-40°C –+70°C
Protection
IP 30
Single-wire clamps
2 x 0.28 mm²–2 x 0.75 mm²
Fine-wire clamps
2 x 0.28 mm²–2 x 0.75 mm²
Bus voltage
20-30 V
Size
175 x 81 x 22 mm
Pos: 78 /Busch-J aeger (Neustr uktur)/Modul-Stru ktur/Online-Do kumentation/Ste uermodule - Onli ne-Dokument ation(--> F ür alle Do kumente <--)/+++++ +++++++ Seitenumbruch +++++++ +++++ @ 9\mod_1268 898668093_0.doc x@ 52149 @ @ 1

ABB-Welcome
|
—11 —
Pos: 79 /Busch-J aeger (Neustru ktur)/Modul- Struktur/Onlin e-Dokumentation/Üb erschriften (--> Für alleD okumente <--)/1 . Ebene/M - O/Montage / Inst allation @ 18\mod_130261 396611 1_15.docx @ 103373 @ 1 @ 1
6 Mounting / Installation
Pos: 80 /B usch-J aeger (Ne ustruktur)/Mo dul-Struktur /Online-Do kumentation/Sic herheit (--> Für alle Dokum ente< --)/Warnhinweis e/Sich erheit- Ni ederspannu ngs-u nd 230 V-Leitungen @ 18 \mod_1302617 821491_15.doc x@ 10 3465 @ @ 1
Warning
Electric voltage!
Risk of death and fire due to electrical voltage of 100-240 V.
–Low-voltage and 100-240 V cables must not be installed together
in a flush-mounted socket!
In case of a short-circuit there is the danger of a 100-240 V load
on the low-voltage line.
Pos: 81 /B usch-J aeger (Ne ustruktur)/Mo dul-Struktur /Online-Do kumentation/Sic herheit (--> Für alle Dokum ente< --)/Warnhinweis e/Sicherh eit - Fachkenntniss e@ 18\ mod_130277438 4017_15.docx @ 103564 @ 2 @ 1
6.1 Requirements for the electrician
Warning
Electric voltage!
Install the device only if you have the necessary electrical engineering
knowledge and experience.
•Incorrect installation endangers your life and that of the user of
the electrical system.
•Incorrect installation can cause serious damage to property, e.g.
due to fire.
The minimum necessary expert knowledge and requirements for the
installation are as follows:
•Apply the "five safety rules" (DIN VDE 0105, EN 50110):
1. Disconnect from power;
2. Secure against being re-connected;
3. Ensure there is no voltage;
4. Connect to earth;
5. Cover or barricade adjacent live parts.
•Use suitable personal protective clothing.
•Use only suitable tools and measuring devices.
•Check the type supply network (TN system, IT system, TT system)
to secure the following power supply conditions (classic
connection to ground, protective earthing, necessary additional
measures, etc.).
Pos: 82 /DinA4 - Anl eitungen Online/Inhalt/ KNX/DoorEntry/Mo ntage/Montage hinweise - Allgemein @ 1 9\mod_13105 63670478_15.doc x@ 107 743 @ 2@ 1

ABB-Welcome
|
—12 —
6.2 General installation instructions
•Terminate all branches of the wiring system via a connected bus device (e.g.,
indoor station, outdoor station, system device).
•Do not install the system controller directly next to the bell transformer and other
power supplies (to avoid interference).
•Do not install the wires of the system bus together with 100-240 V wires.
•Do not use common cables for the connecting wires of the door openers and wires
of the system bus.
•Avoid bridges between different cable types.
•Use only two wires for the system bus in a four-core or multi-core cable.
•When looping, never install the incoming and outgoing bus inside the same cable.
•Never install the internal and external bus inside the same cable.
Pos: 83 /Busch-J aeger (Neustr uktur)/Modul-Stru ktur/Online-Do kumentation/Ste uermodule - Onli ne-Dokument ation(--> F ür alle Do kumente <--)/+++++ +++++++ Seitenumbruch +++++++ +++++ @ 9\mod_1268 898668093_0.doc x@ 52149 @ @ 1

ABB-Welcome
|
—13 —
Pos: 84 /Busch-J aeger (Neustru ktur)/Modul- Struktur/Onlin e-Dokumentation/Üb erschriften (--> Für alleD okumente <--)/2 . Ebene/M - O/Mont age @ 18\mod_1 302615960458_1 5.docx @ 103424 @ 2 @ 1
6.3 Mounting
Pos: 85.1 /DinA 4- Anl eitungen Online/Inhalt/ KNX/DoorEntry/8 3220-AP-xxx/Montage - M odule/Montage - M ontagedose -- 83220-AP- xxx @ 19\mod_132325 0406848_15.docx @ 1110 98 @ @ 1
Recommended installation height
Dismantling
Pull the clamp on the bottom of the device and then open the housing of the panel.

ABB-Welcome
|
—14 —
Installation dimensions for slotted screw holes
1. The bottom of the device has screw holes for fastening on the wall according to
the above dimension instructions.
2. In addition, the bottom of the device can be fixed to the existing flush-mounted
box. The dimension of the compatible flush-mounted box is shown above.
Wiring
Fix the bottom of the device and connect it with reference to the graphics. The insulated
section of the cable end must not be longer than 10mm.
Settings
Set addresses of the preferred outdoor stations and the address of the indoor station on
the jumper (see chapter " Adjusting the device ").

ABB-Welcome
|
—15 —
Mounted on the wall
1. Fix the bottom of the device to the wall.
2. Latch the upper part of the device onto its bottom part: place the upper side of the
device on the lock-in lugs and then press the bottom side onto the bottom part of
the device until it is caught by the clamp.
Mounted with flush-mounted box
1. Fix the bottom of the device to the existing flush-mounted box.
2. Latch the upper part of the device onto its bottom part: place the upper side of the
device on the lock-in lugs and then press the bottom side onto the bottom part of
the device until it is caught by the clamp.
The installation of the indoor station is now complete.
Pos: 94 /Busch-J aeger (Neustr uktur)/Modul-Stru ktur/Online-Do kumentation/Ste uermodule - Onli ne-Dokumentatio n(--> F ür alle Do kume nte< --)/+++++++ +++++ Seitenumbruch +++++++++ +++ @ 9\mod_1268898668 093_0.docx @ 52149 @ @ 1

ABB-Welcome
Pos: 95 /DinA4 - Anl eitungen Online/Inhalt/ KNX/DoorEntry/Pr ojektierung-Mer kblatt/Proje ktierPos: 9 7/Bu sch-Jaeger (Neus truktur)/Modul-Str uktur/Online-Doku mentation/Rückseiten (--> Für alle Doku mente<--) /Rückseite - Busch-Jaeger - Allge mein @ 20\mod_132732007 4886_15.docx @ 137103 @ @ 1
Notice
=== Ende der List ef ürT extmar keB ackcover ===
We reserve the right to at all times make technical changes as well as changes in the
contents of this document without prior notice.
The detailed specifications agreed to at the time of ordering apply to all orders. ABB
accepts no responsibility for possible errors or incompleteness in this document.
We reserve all rights to this document and the topics and illustrations contained
therein. The document and its contents, or extracts thereof, must not be reproduced,
transmitted or reused by third parties without prior written consent by ABB.
Table of contents
Other ABB Intercom System manuals

ABB
ABB H81402FR Series User manual

ABB
ABB Welcome M2303 User manual

ABB
ABB WelcomeTouch 83220-SM 515 Series User manual

ABB
ABB H8137xPx-S User manual

ABB
ABB M2231 SERIES User manual

ABB
ABB H82351 Series User manual

ABB
ABB Video kit User manual

ABB
ABB H8131 P Series User manual

ABB
ABB 83220-SM-xxx-500 User manual

ABB
ABB M2304 User manual

ABB
ABB H8303 User manual

ABB
ABB 83205-SM-500 Series User manual

ABB
ABB M22001 series User manual

ABB
ABB Video Outdoor Station User manual

ABB
ABB 2Line User manual

ABB
ABB Welcome IP User guide

ABB
ABB i-HD H81365P A Series User manual

ABB
ABB M22311 Series User manual

ABB
ABB Video kit User manual

ABB
ABB M22311 Series User manual