SURFACE MOUNTED LUMINAIRES
—
yawediuG
INSTRUCTION LEAFLET
EN
05
—
Contacts
Art. nr. 69452/30 Rev E 03.11.2017
We reserve the right to make technical changes or modify the
contents of this document without prior notice. With regard to
purchase orders, the agreed particulars shall prevail. ABB AG
does not accept any responsibility whatsoever for potential
errors or possible lack of information in this document.
We reserve all rights in this document and in the subject matter
and illustrations contained therein. Any reproduction, disclosure
to third parties or utilization of its contents – in whole or in
parts – is forbidden without prior written consent of ABB AG.
Copyright© 2017 ABB
All rights reserved
NOTE: The information on this page applies to
Self Contained luminaires
EXTRA ITEMS IN BOX EXPLODED VIEW
®
Technical Specifications
Power supply Self-Contained: 230-240V 50Hz
Slave (/LTC): 220-240V 50/60Hz / 176-275V DC
Autonomy 3 hours
Commissioning time 60 hours
Ambient temperature Self-Contained: +5°C ... +35°C Slave: 0°C ... +35°C
Protection class II
Degree of protection IP40
Battery NiMH 2,4V - 1,1Ah ( Self Contained)
Lightsource 22M: 12 LED’s (1,8W) 32M: 24 LED’s (3,6W)
Compliance
PRODUCT INFORMATION
EN 60598-1, EN 60598-2.22, VDE 0711, IEC 62034, EN 62386-202
Carefully read this instruction leaflet before installing or using the luminaire. This leaflet
provides important information about the correct installation, use, maintenance and
disposal of this product.
Please observe the following guidelines:
1. The luminaire should only be installed by qualified personnel and installation
must be in accordance with European installation requirements HD 60364 and
additional local regulations.
2. This product may not be modified in any way what so ever or used for a purpose or
in an environment other than for which it is designed. Failling to observe these
guidelines will invalidate the warranty and the CE-compliance of this product.
3. Before installing the luminaire, the supply must be isolated.
4. The lightsource in this luminare is non-replaceable.
INSTALLING AND CONNECTING
The luminaire should be connected to the voltage equivalent to that indicated on
the type label. This luminaire is fitted with a terminal block suitable for loop-in-loop-out
connection. For further information on the different connection possibilities, see
the instructions in this instruction leaflet.
SELF-TESTING
All self-contained versions of this luminaire are equipped with an automatic self-testing
system that continuously monitors battery operation, the light source(s) and the
electronics. The amber LED’s will indicate when one of these component is not working
properly. To prevent all luminares to start the test sequence at the same time, an odd and
even function is available. All even luminares start the test sequence as normal; all odd
luminares start the test sequence 24 hours later. The luminaire can also be tested
manually with the test button. When pushing the button the battery will supply the LED’s.
After 5 seconds an eventual error will be displayed. The test schedule can be reset by
pushing the test button for 10 seconds. For more detailed information on the different
testing schedule and meaning of the indications, see further in this instruction leaflet.
LUMINAIRES POWERED FROM CENTRAL BATTERY SYSTEMS
These luminaires are not equipped with their own integrated testing function. They are
tested by means of the central battery system to which the luminaire is connected.
CT-NAVEO-LUMINARES
Central test luminaires (CT-Naveo / CIS) are supplied under a separate part code and are
fitted with a test system PCB (COM-Box).
SLAVE LUMINAIRES WITH LTC
Slave type luminares for Emex / Sentara central emergency power systems are supplied
under a separate part code and are fitted with an LTC PCB (COM-Box).
BATTERY
A fault will occur when test results for duration no longer meets the
requirements indicated for the luminaire. The batteries must then be replaced.
Please see the label on the batteries for the type required. Given the technical
life of the battery, it is recommended to replace them after 4 years. When the
battery is replaced and the mains supply restored, the amber LED indicating
a battery failure will disappear after a successful duration test. Used batteries
must be replaced or disposed of as household chemical waste.
PLEASE NOTE!
Constant voltage is required and the batteries must be sufficiently charged for
emergency lighting to function properly. Failure to observe this requirement can damage
the batteries, the lightsource or in worst-case scenario, the luminaires electronics.
INSPECTION AND MAINTENANCE
Emergi-lite strongly advises annual inspection of your emergency lighting installation.
INSTALLATION & COMMISSIONING
EXPLANATIONS
SELFTEST SCHEDULE
Autonomy test
Every 26 weeks - 3 hours.
Functional test
Every 7 days - 1 minute.
Installation test (part of commissioning)
Duration test after 36 hours - 3 hours.
1
2
3
.
b
l
i
n
k
b
l
i
n
k
60h60h
After 60 hours the luminaire is fully commissioned.
Connect mains
230 - 240V / 50Hz
Wait
100%0-30%
b
l
i
n
k
b
l
i
n
k
Maintained Non-maintained Switched
maintained
Emergency mode
In test
OK
Failure: lamp,
battery, electrical
Manual testing
Push test button < 1 sec. to set luminaire in test mode (5 sec. test).
Setup even or odd testing schedule
Push test button > 3 sec. to enter the setup mode for even or odd testing schedule.
If LED’s flash in phase the luminare is set to even schedule.
If LED’s flash out of phase the luminare is set to odd schedule.
Toggle between even and odd by pushing the test button.
Reset luminaire
Push test button > 10 sec. to reset test schedule.
Wall bracket
Junction box cover
First Fix spacer
First Fix
Ebox
Lightguide
COM-box
(for CIS/LTC
DALI luminaires)
ABB Emergi-Lite Ltd
Bruntclie Lane
Morley, Leeds
West Yorkshire LS27 9LL
United Kingdom
Sales +44 (0) 333 999 9900
Technical +44 (0) 113 281 0600
Email: LV[email protected].com
www.emergi-lite.co.uk
ABB United Arab Emirates
P.O. Box 11070
Dubai,
United Arab Emirates
Tel: +971 (4) 3147500
Fax: +971 (4) 3401541
E-mail: [email protected]
www.abb.com/lowvoltage
DALI LUMINAIRES
Self-Contained luminaires fitted with a DALI communication module are supplied
under a separate article number and have a configurable autotest (not equal to self test).
KM 655958
Self-Contained:
21
3
421
3
4
B
A
D F
E
C B
A
D F
E
C
!!
SPECIAL MOUNTING
When mounting on a junction box, use the junction box cover
CONNECTING
Slave Luminaire
max. 3 x 2,5 mm²
Self Contained Luminaire
max. 4 x 2,5 mm²
CEILING
Installing
WALL WALL (EBOX HIGH)
1
2
3
4
When mounting with a cable tray, use the First Fix spacer.
(First Fix spacer not required when mounting on a junction box)
+ -+ -
! !
ca. 30% - 100%
0V - 10V
-+
ca. 30%
-+
Before securing the FIrst Fix, please note the markings that indicate the
direction of the Ebox. There is only one way the Ebox can be placed
on the First Fix, it can not be rotated 180o
A
Full DIM:
– using red wire
– light output ca. 30%
BC
D F
E
A
BC
D F
E
1
2
3
4
3
4
1
2
3
4
Close transparent wire cover on First Fix
Place the Ebox over the FIrst Fix
Screw the Ebox onto the First Fix
Place the pictogram plate(s) by pushing them
up against the spring
PLEASE NOTE!
Orientation First Fix – Ebox
PLEASE NOTE!
Orientation First Fix – Ebox
Installing Installing
3
3
1 2 4
3
3
1 42
*PLEASE NOTE! This luminaire is rated with insulation Class II. The earth terminal is provided for convenience of wiring through only and should not form any part of any protective shield.
Change the ceiling mounted luminaire to
a wall mounted luminaire
Change the ceiling mounted luminaire to
a wall mounted luminaire
Using external dimmer:
– 0V - 10V
– light output ca. 30% - 100%
DIM
Mounting
Dimensions 138
33
138
43
Mounting
Dimensions
Mains
LTC- LTC+ DIMSWL N USL
220 - 240V AC / 176 - 275V DC
Max 10A
230 - 240V 50Hz
Max 10A
Maintained
Switch-
maintained
Non-
maintained
1L and
2L same
phase
Junction box
Junction box cover
E25 Cable tray
First fix spacer
DIM BUS/MD
CIS /
DALI
DA DA
LTC
!
Do not connect Mains power to
the A-B-C-D terminals

Other ABB Lighting Equipment manuals

ABB PrimEvo SM100E Manual

ABB

ABB PrimEvo SM100E Manual

ABB KAUFEL Lutia Manual

ABB

ABB KAUFEL Lutia Manual

ABB Stanilite User manual

ABB

ABB Stanilite User manual

ABB Emergi-Lite Serenga Sun-Lite Manual

ABB

ABB Emergi-Lite Serenga Sun-Lite Manual

ABB Stanilite Spitfire Standard User manual

ABB

ABB Stanilite Spitfire Standard User manual

ABB Thomas & Betts Standard User manual

ABB

ABB Thomas & Betts Standard User manual

ABB Stanilite Spitfire Standard User manual

ABB

ABB Stanilite Spitfire Standard User manual

ABB Stanilite Emergency User manual

ABB

ABB Stanilite Emergency User manual

ABB Stanilite Quickfit Standard User manual

ABB

ABB Stanilite Quickfit Standard User manual

ABB EGNL Series User manual

ABB

ABB EGNL Series User manual

ABB Stanilite Economy e-Luna circular LED User manual

ABB

ABB Stanilite Economy e-Luna circular LED User manual

ABB EMERGI-LITE Guideway Manual

ABB

ABB EMERGI-LITE Guideway Manual

ABB Stanilite Standard User manual

ABB

ABB Stanilite Standard User manual

ABB Stanilite Nexus RF User manual

ABB

ABB Stanilite Nexus RF User manual

ABB Stanilite Spitfire Standard User manual

ABB

ABB Stanilite Spitfire Standard User manual

ABB Thomas&Betts Standard User manual

ABB

ABB Thomas&Betts Standard User manual

ABB Stanilite Quickfit Nexus LX User manual

ABB

ABB Stanilite Quickfit Nexus LX User manual

ABB EMERGI-LITE Serenga Manual

ABB

ABB EMERGI-LITE Serenga Manual

ABB GE ReliaGear Lighting Panelboard User manual

ABB

ABB GE ReliaGear Lighting Panelboard User manual

ABB PrimEvo TW220E Manual

ABB

ABB PrimEvo TW220E Manual

ABB Thomas & Betts Standard User manual

ABB

ABB Thomas & Betts Standard User manual

ABB Stanilite Standard User manual

ABB

ABB Stanilite Standard User manual

Popular Lighting Equipment manuals by other brands

luceco LXB12W Series Installation & operating instructions

luceco

luceco LXB12W Series Installation & operating instructions

ARRI Orbiter Short manual

ARRI

ARRI Orbiter Short manual

ProLights PIXIE BEAM user manual

ProLights

ProLights PIXIE BEAM user manual

TOBIAS GRAU XT-S TWO SIDE FLOOR Assembly instructions

TOBIAS GRAU

TOBIAS GRAU XT-S TWO SIDE FLOOR Assembly instructions

Lithonia Lighting TFR Series installation instructions

Lithonia Lighting

Lithonia Lighting TFR Series installation instructions

Germania 1525 Assembly instruction

Germania

Germania 1525 Assembly instruction

PR XRLED 3500-W Framing manual

PR

PR XRLED 3500-W Framing manual

QTX Light Atlantis user manual

QTX Light

QTX Light Atlantis user manual

hillvert HT-LIGHT-100 user manual

hillvert

hillvert HT-LIGHT-100 user manual

Viabizzuno toccami A9.533.55 Installing instructions

Viabizzuno

Viabizzuno toccami A9.533.55 Installing instructions

Griven PARADE S-20 instruction manual

Griven

Griven PARADE S-20 instruction manual

DOTLUX Lightshower Series user manual

DOTLUX

DOTLUX Lightshower Series user manual

GE LEDE5-G50-25(0.3 Important safety instructions

GE

GE LEDE5-G50-25(0.3 Important safety instructions

ATM Lighting HPL450LED Installation and maintenance manual

ATM Lighting

ATM Lighting HPL450LED Installation and maintenance manual

Bresser F001341SH instruction manual

Bresser

Bresser F001341SH instruction manual

Daniamant Dan WR3-2 Installation and maintenance instructions

Daniamant

Daniamant Dan WR3-2 Installation and maintenance instructions

EuroLite FBL-10 user manual

EuroLite

EuroLite FBL-10 user manual

Future light PHW-260 Pro-Head-Wash user manual

Future light

Future light PHW-260 Pro-Head-Wash user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.