manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ABB
  6. •
  7. Relay
  8. •
  9. ABB A 145 User manual

ABB A 145 User manual

A1 A2
1L2 3L2 5L3
2T1 4T2 6T3
14X
NO
NC
NC
NO
13X
21X
22X
A1 A2
1L2 3L2 5L3
2T1 4T2 6T3
14X
NO
NC
NC
NO
13X
21X
22X
44X
NO
NC
NC
NO
43X
31X
32X
Operating instructions
Betriebsanleitung
Notice d’instructions
Instruktion
Istruzioni tecniche
IInstrucciones de empleo
Ohje
Contactors
Schtze
Contacteurs
Kontaktorer
Contattori
Contactores
Kontaktori
A1
A2
M 3,5
1 N.m
5Pozidriv N 2
2 x 1 ................... 2,5 mm
2 x 0,75 ............. 2,5 mm2
2
/ > 3,5 mm, L < 8 mm
L
/
Pos. 5
Pos. 4 Pos. 3
Pos. 2
Pos. 1
Max. 32mm Max. 30mm
Max. 10mm
M10
28 N.m - 240 lb.in
M8
18 N.m - 160 lb.in
A 145, A 185
AF 145, AF 185
A 145, A 185
AF 145, AF 185
A 210, A 260, A 300
AF 210, AF 260, AF 300
A 210, A 260, A 300
AF 210, AF 260, AF 300
Max. 24mm Max. 22mm
Max. 8mm
1
2
1 2+A ... -30-22
AF ... -30-22
A ... -30-11
AF ... -30-11
1
1L1 3L2 5L3
2T1 4T2 6T3A2
A1 31X
NC
43X
44X32X
NO
NCNO
13X
NC
21X
22X14X
NO
NCNO
1L1 3L2 5L3
2T1 4T2 6T3A2
A1 13X
NC
21X
22X14X
NO
NCNO
1SFC 380003-89, 1(4), ed.E, April 2010
AF 145, AF 185, AF 210, AF 260, AF 300
A 145, A 185, A 210, A 260, A 300
Warning! The operation, installation and servicing of this product must be carried out by a qualified electrician, following installation standards and safety regulations.
Before operating the contactor, make sure that the control voltage supply corresponds with the coil marking. Wrong control voltage can damage the coil. Do not touch
live parts. Danger!
Warnung! Die inbetriebnahme und die installation des vorhandenen Gerätes sowie jegliche Wartungsarbeiten müssen durch einen Fachelektriker, der die anerkannten
technischen Regeln, die Montagenormen und die Sicherheitsvorschriften beachtet, durchgefürt werden. Vor Inbetriebnahme der Schüttze prüfen ob Steuerspannung
am Verwendungsort mit den aufgedruckten Spulendaten übereinstimmt. Der Anschluss einer anderen Steuerspannung kan zur Zerstörung der Spule führen.
Spannung führende Teile nicht berühren. Lebensgefahr!
Attention! La mise en ceuvre et I'installation de cet appareil et toute intervention doivent être affectuées par un électricien professionnel appliquant les normes
d'installation et les réglements de sécurité. Avant la mise en marche des contacteurs, vérifier que la tension du circuit de contrôle correspond bien aux indications de la
bobine. Le raccordement d'une tension différente peut mener à une destruction de la bobine. Ne pas toucher les pièces sous tension. Danger de mort!
Varning! Igångsättning och installation av apparaten samt alla ingrepp bör utföras av en kompetent elektriker enligt alla gällande installationsnormer och säkerhetsregler.
Kontrollera före installation av kontaktorn att aktuell manöverspänning överensstämmer med spolens märkdata. Felaktig manöverspänning kan skada spolen.
Beröring av spänningsförande delar är förenat med livsfara.
Attenzione! La messa in opera, I'installazione di questo apparecchio ed ogni tipo di intervento devona essere effettuati da un elettricista professionista il quale applichi
le regole del mestiere, le norme di installazioneed i regolamenti di sicuezza. Prima della messa in servizio del contattore, verificare che la tensione del circuito di comando
corrisponda esattamente a quella indicata sulla bobina.
L'alimentazione con una tensione diversa, puo provocare la distruzione della bobina. Non toccare le parti attive. Pericole de vita!
Atención! La puesta en aplicación, la instalación de este aparato y cualquier intervención deben realizarse por un electricista profesional que aplique las reglas del oficio
las normas de instalaciones y la reglamentación de seguridad. Antes de la puesta en servicio del contactor, comprobar si coinciden la tensión de mando con los datos
impresos en la bobina. La conexión de otra tensión de mando puede producir la destruccion de la bobina. Las partes bajo tensión no deben tocarse. Peligro de muerte!
30°
30°
Pos 1 ± 30°
A(F) 145, 185: Enclosure with min. dimension 24 by 20 by 10 inches should be used.
According to UL 508:
A(F) 210, 260, 300: Enclosure with min. dimension 36 by 30 by 12 inches should be used.
Use wire Cu 75 C only.
注意!所有对此产品的操作、安装及维护,均需由合格的电气工程师,在遵循安装标准及安全准则的条件下进行。在运行之前,
确认控制电压与与线圈上标识一致,否则会损坏线圈。不要接触带电部分。危险!
AF: 12 VA
A/AD: XX VA
A(AF)145(D),A(AF)185(D), A205D = A/AD: 51 VA
A(AF)210,A(AF)260,A(AF)300,A260D,A300D
A370D = A/AD: 89VA
General
Control with voltage on A1 and A2
AF-Contactors
The AF-Contactors have the same dimensions and nearly the same apperance as
the A-Contactors of equal rating. The only difference is that AF-Contactors are
fitted with an electronic coil interface. For a given coil, this interface allows the
contactor to accept a very wide voltage range a well in d.c. as in a.c. , 50 or 60 Hz.
Operatin of AF-Contactors can be done as with conventional contactors by
applaying and removing voltage on A1 and A2. The function limits are very exact
compared with a conventional contactor and there is a built in hysterises in the
function.
Note: Minimum length of the starting pulse=70 ms
AF-Contactors comply with international standards IEC 947-1, IEC 947-4-1 and European standards EN 60 947-1, EN 60 497-4-1. Moreover in
environment 2, they meet the electromagnetic compability rules (EMC): additional clauses A11 and A11 to above mentioned EN standards.
Using these materials in environment 1 may lead to radio-interferences requiringthe use of aditional mitigation methods. Here are the definitions
given in the additional clause A11 to standard EN 60 497-1.
Environment 1: "Mainly relates to low-voltage public networks such as residential, commercial and light industrial locations/installations.
Highly distributing sources such as arc welders are not covered by this environment".
Environment 2: "Mainly relates to low-voltage industrial networks/locations/installations including highly distrurbing sources".
Position
Contactor
closed
Contactor
open
100V 250V
Control
voltage
Normal range
Accepted range
77% of lower voltage range level
55% of lower voltage range level
56
x3
x3
1/4
x4
2x3
11
12
9
2x3
10
KZ 185,300
KZ 185,300
2x3
8
7
1
1/4
x4
2x3
2
3
4
13
1/2
5x4
46
1
2
1/4
3x4
(A 145...300)
ZA 185, 300 ZAF 185, 300
(AF 145...300)
1SFC 380003-89, 2(4)
8 Nm - 71 lb.in
13
9
10
7
7
8
Click
11
1/2
14
x4
15
16
x4
2
Lift
Lift
3
3 5
2
4
1
4
6
Lift
1SFC 380003-89, 3(4)
7
8
12
11
A 145, A 185
AF 145, AF 185
A 210, A 260, A 300
AF 210, AF 260, AF 300
AF 145, 185
ZAF 185
AF 210, 260, 300
ZAF 300
A 145, 185
ZA 185
A 210, 260, 300
ZA 300
1/4
ABB AB, Cewe-Control
SE-721 61 Västerås, Sweden
Telephone +46 21 32 07 00
Telefax +46 21 12 60 01
2,9 Nm - 26 lb.in
2,9 Nm - 26 lb.in
165
M5
35
187
M5
43,8
A145, A185
AF145, AF185
A210, A260, A300
AF210, AF260, AF300
1SFC 380003-89, 4(4)

This manual suits for next models

9

Other ABB Relay manuals

ABB CM Manual

ABB

ABB CM Manual

ABB RE 610 Series User manual

ABB

ABB RE 610 Series User manual

ABB Relion REX610 User manual

ABB

ABB Relion REX610 User manual

ABB CRN-1 Manual

ABB

ABB CRN-1 Manual

ABB REM 610 User manual

ABB

ABB REM 610 User manual

ABB Relion 615 series User manual

ABB

ABB Relion 615 series User manual

ABB C6701 User manual

ABB

ABB C6701 User manual

ABB KLF Manual

ABB

ABB KLF Manual

ABB Relion 615 series User manual

ABB

ABB Relion 615 series User manual

ABB CT-C Series User manual

ABB

ABB CT-C Series User manual

ABB Rellon 620 Series User manual

ABB

ABB Rellon 620 Series User manual

ABB C6701 User manual

ABB

ABB C6701 User manual

ABB BT50 User manual

ABB

ABB BT50 User manual

ABB CM-SRS.11 User manual

ABB

ABB CM-SRS.11 User manual

ABB RELION REX640 User manual

ABB

ABB RELION REX640 User manual

ABB TA 80 DU V1000 User manual

ABB

ABB TA 80 DU V1000 User manual

ABB 41-331.21 Manual

ABB

ABB 41-331.21 Manual

ABB SSV-T Manual

ABB

ABB SSV-T Manual

ABB TA200DU User manual

ABB

ABB TA200DU User manual

ABB REM 610 User manual

ABB

ABB REM 610 User manual

ABB REM 610 User manual

ABB

ABB REM 610 User manual

ABB SC Manual

ABB

ABB SC Manual

ABB ELR48P User manual

ABB

ABB ELR48P User manual

ABB REU 523 User manual

ABB

ABB REU 523 User manual

Popular Relay manuals by other brands

Schrack LSD2 Series operating instructions

Schrack

Schrack LSD2 Series operating instructions

Woodward WIP1 manual

Woodward

Woodward WIP1 manual

Eaton EMR5-AWN500-1 Operating and installation instructions

Eaton

Eaton EMR5-AWN500-1 Operating and installation instructions

Rievtech xLogic ELC Series user manual

Rievtech

Rievtech xLogic ELC Series user manual

Seg HighTECH MRU3-2 manual

Seg

Seg HighTECH MRU3-2 manual

Moeller Xcomfort CSEZ-01/18 Assembly instructions

Moeller

Moeller Xcomfort CSEZ-01/18 Assembly instructions

Pilz PSWZ X1P operating manual

Pilz

Pilz PSWZ X1P operating manual

Pilz PNOZ s8 operating instructions

Pilz

Pilz PNOZ s8 operating instructions

Arcteq AQ-F255 instruction manual

Arcteq

Arcteq AQ-F255 instruction manual

Leuze MSI-SR5B Original operating instructions

Leuze

Leuze MSI-SR5B Original operating instructions

Novatek-electro RN-101М user manual

Novatek-electro

Novatek-electro RN-101М user manual

Siemens SIRIUS 3UG4511-.A operating instructions

Siemens

Siemens SIRIUS 3UG4511-.A operating instructions

Basler BE1-79A instruction manual

Basler

Basler BE1-79A instruction manual

Woodward 2301A quick start guide

Woodward

Woodward 2301A quick start guide

Siemens FS-RU2 Installation instructions & user guide

Siemens

Siemens FS-RU2 Installation instructions & user guide

Thytronic DMC3S manual

Thytronic

Thytronic DMC3S manual

Elk Products ELK-912 instructions

Elk Products

Elk Products ELK-912 instructions

GE SPA11A instructions

GE

GE SPA11A instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.