ACME Aeco 20 User manual


CONTENTS
1. Safety Instructions ......................................................................................... 2
2. Technical Specifications ................................................................................. 4
3. Control Panel ................................................................................................. 6
4. Effect Wheels ................................................................................................. 7
4.1 Replacing Rotating Gobos ........................................................................ 8
5. How To Set The Unit..................................................................................... 10
5.1 Main Function........................................................................................ 10
5.2 Home Position Adjustment .................................................................... 19
6. Control By Universal DMX Controller ........................................................... 25
6.1 DMX512 Connection.............................................................................. 25
6.2 Address Setting ...................................................................................... 26
6.3 DMX512 Configuration........................................................................... 26
7. Error Information......................................................................................... 39
8. Troubleshooting........................................................................................... 46
9. Fixture Cleaning........................................................................................... 47
1A

1. Safety Instructions
WARNING
Please keep this User Manual for future consultation. If you sell the unit to another user, be sure
that they also receive this manual.
Important:
Damages caused by the disregard of this user manual are not subject to warranty. The dealer will
not accept liability for any resulting defects or problems.
Unpack and check carefully to ensure that there is no transportation damage before using the
unit.
This product is for indoor use only. Use only in a dry location.
DO install and operate by qualified operator.
DO NOT allow children to operate the fixture.
Use safety chain when fixing the unit. Handle the unit by carrying its base instead of head only.
The unit must be installed in a location with adequate ventilation, at least 50cm from adjacent
surfaces.
Be sure that no ventilation slots is blocked, otherwise the unit will be overheated.
Before operation, ensure that you are connecting this product to the proper voltage in
accordance with the specifications in this manual or on the product’s specification label.
It’s important to ground the yellow/green conductor to earth in order to avoid electric shock.
Minimum ambient temperature TA: 0℃. Maximum ambient temperature TA: 40℃.Do not
operate this product at a lower or higher temperature.
DO NOT connect the device to any dimmer pack.
Keep flammable materials away from the fixture while operating to avoid fire hazard.
Make sure the power cord is not crimped or damaged; replace it immediately if damaged.
Unit’s surface temperature may reach up to 75℃. DO NOT touch the housing bare-handed
during its operation.
Avoid any flammable liquids, water or metal from entering the unit. Once it happens, cut off
the mains power immediately.
Please read the instruction carefully which includes important information about
the installation, usage and maintenance.
2A

DO NOT operate in a dirty or dusty environment. DO clean the fixture regularly.
DO NOT touch any wire during operation as there might be a hazard of electric shock.
Avoid entanglement of the power cord with other wires.
The minimum distance to objects/surface must be more than 3 meters.
In the event of serious operating problem, stop using the unit immediately.
Never turn on and off the unit time after time.
The housing, the lenses, or the ultraviolet filter must be replaced if they are visibly damaged.
DO NOT open the housing as there are no user serviceable parts inside.
DO NOT attempt to operate this unit if it becomes damaged. DO NOT attempt any repairs
yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please
contact the nearest authorized technical assistance center if needed.
Disconnect this product from its power source before servicing.
DO use the original packaging if the device is to be transported.
Avoid direct eye exposure to the light source while the product is on.
DO NOT operate this product if you see damage on the housing, shields, or cables. Have the
damaged parts replaced by an authorized technician at once.
Installation:
The fixture should be fixed on the clamp. Always ensure that the unit is firmly fixed to avoid
vibration and slipping off during operation. Ensure that the trussing or area of installation must be
able to hold 10 times the weight without any deformation. Always install a safety cable that can
hold at least 12 times the weight of the fixture when installing.
DO install and operate by qualified operator. It must be installed in a place where there is out of the
reach of people.
3A

2. Technical Specifications
Power Voltage:
100-240V~ 50/60Hz
Power Consumption:
1590W
Light Source:
SSL1400YF-70-R95
Color Temperature:
6000K
Zoom Range:
5°~50°
Movement:
Pan: 540°
Tilt: 270°
Pan/Tilt Resolution: 16 bit
Fixation: Pan/Tilt lock
Dimmer/Shutter:
Smooth dimming from 0-100%; outstanding strobe effect with variable speed
Color Wheel:
Color Wheel A: 6 colors plus open
Color Wheel B: 5 colors plus open
Gobo Wheel:
1 x static gobo wheel with 9 gobos plus open
1 x rotating gobo wheel with 7 gobos plus open, convenient replacement
Control:
DMX Channel: 3 7/2 8/3 1/2 2 Channels
Control Mode: DMX512, RDM, Art-Net, sACN
Firmware upgrade via DMX link or USB Disk
4A

Construction:
Display: LCD display
Battery backup for user setup without power connection
Data In/Out: 3-pin and 5-pin XLR, RJ45
Power In/Out: Power Cord in; Power Connector in/out
Protection Rating: IP20
Features:
Color Rendering: Ra≥95; R9≥90; R15≥95; TLCI≥95; CCI: 0-0.5G
Linear CMY color mixing
Variable CTO
1 x animation wheel with outstanding water and flame effect, the wheel can rotate and be replaced
1 x 4-facet prism rotatable in either direction
1 x 4-facet linear prism rotatable in either direction
2 different frost filters to create and improve the wash effect. They can be used independently and
overlayed
Motorized linear iris
4 x fast and smooth framing shutters; The position and the angle of each shutter blade can be
controlled individually; Each shutter blade can block out light completely; The framing module can
be rotated at ±60 degrees
2 x fixed clamps for 50mm truss
Dimension/Weight:
465x352x815.5mm, 47.5kgs
18.3"x13.9"x32.1"in, 104.7lbs
Photometric Diagram:
5A

3. Control Panel
Power Cord Version:
Powercon Version:
1. Display: To show the various menus and the selected function
2. Button:
MENU
To enter into move backward or leave the menu
UP
To go backward to move up in the menu
DOWN
To go forward to move down in the menu
ENTER
To perform the desired functions
3. FIRMWARE UPGRADE: Used to upgrade the fixture’s firmware
4. BATTERY DISPLAY
5. ETHERNET: Transfers fixture’s information to a main controller
6. DMX IN:
For DMX512 link, use 3/5 -pin XLR cable to link the unit and DMX controller to input DMX signal
7. DMX OUT:
For DMX512 link, use 3/5 -pin XLR cable to link the next units to output DMX signal
8. POWER(Power Cord Version): To connect to supply power
9. POWER SWITCH: To turn on/off the power
10. POWERCON IN(Powercon Version):To connect to supply power
11. POWERCON OUT(Powercon Version):To connect to the next fixture
6A

4. Effect Wheels
DANGER!
Install the rotating gobos with the device switched off only.
Unplug from mains before changing the rotating gobos!
CAUTION: Never unscrew the screws of the rotating gobo as the ball bearing will otherwise be
opened!
R-Gobos
Part Number
①Gobo1
3011001272
②Gobo2
3011001273
③Gobo3
3011001274
④Gobo4
3011001275
⑤Gobo5
3011001276
⑥Gobo6
3011001277
⑦Gobo7
3015001041
7A

4.1 Replacing Rotating Gobos
1. Unplug the power and signal adapter cables at A and unscrew the two screws at B to take out the
component;
2. Unscrew the six screws at C to take out the static gobo wheel; Unplug the four detection wires at
D and the four motor wires at E;
3. Turn the component over and unscrew the ten screws at F to separate the GOBO component and
the CMY component;
8A

4. Unscrew the two screws used to fix the fan at G from the front of the GOBO component and
remove the fan; Half loosen the screws of the three motors at H and remove the belts; Turn the
GOBO component over and unscrew the six screws at I to take out the rotating gobo wheel
component;
5. Gently lift the gobo holder from the edge of the rotating gobo wheel (reverse side) as J shows and
slowly pull it out;
6. Remove the spring lock at K with an appropriate tool like tweezers (if the gobo is coated with
glass glue, do remove it with some good glass cleaning fluid before removing the spring lock to
avoid damage to the gobo).
9A

7. Do not touch the surface of the gobo with bare fingers. The gobo has a small position point at its
edge which has to aim at the position point on the gobo holder as L shows (glossy side towards the
light source).
8. Insert the gobo holder back into the rotating gobo wheel component in this way that its position
point has to exactly aim at the center of the rotating gobo wheel.
9. After installation, put the component back to the fixture.
5. How To Set The Unit
5.1 Main Function
Turn on the unit, press the MENU button into menu mode, and press the UP/DOWN button until
the required function is shown on the monitor. Select the function by pressing the ENTER button.
Use the UP/DOWN button to choose the submenu, press the ENTER button to store and
automatically return to the last menu. Press the MENU button or let the unit idle 30 seconds to exit
menu mode.
The main functions are shown below:
10A

11A

DMX Settings
To select DMX Settings, press the ENTER button to confirm, use the UP/DOWN button to select
DMX Address, DMX Channel Mode, No DMX Status, Connect Option, Network, Art-Net Settings,
sACN Settings, Artnet to DMX or View DMX Value.
DMX Address
To select DMX Address, press the ENTER button to confirm. Use the UP/DOWN button to adjust the
address from 001 to 476/485/482/491, press the ENTER button to store. Press the MENU button back
to the last menu or let the unit idle 30 seconds to exit menu mode.
DMX Channel Mode
To select DMX Channel Mode, press the ENTER button to confirm. Use the UP/DOWN button to
select (37)Framing, (28)Spot, (31)F-Wash or (22)Wash, press the ENTER button to store. Press the
MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.
No DMX Status
To select No DMX Status, press the ENTER button to confirm. Use the UP/DOWN button to select
Blackout(fixture blacks out if DMX signal stops), Hold(fixture continues to obey the last command it
received Via DMX if DMX signal stops) or Manual(the fixture will automatically read the DMX value
in the “Manual Test” menu for operation after selecting this mode), press the ENTER button to store.
Press the MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.
Connect Option
To select Connect Option, press the ENTER button to confirm. Use the UP/DOWN button to select
Auto, DMX, Art-Net or sACN, press the ENTER button to store. Press the MENU button back to the
last menu or let the unit idle 30 seconds to exit menu mode.
Network
To select Network, press the ENTER button to confirm. Use the UP/DOWN button to select IP
Address or Subnet Mask, press the ENTER button to store. Press the MENU button back to the last
menu or let the unit idle 30 seconds to exit menu mode.
Art-Net Settings
To select Art-Net Settings, press the ENTER button to confirm. Use the UP/DOWN button to select
Net, Subnet or Universe, press the ENTER button to store. Press the MENU button back to the last
menu or let the unit idle 30 seconds to exit menu mode.
12A

sACN Settings
To select sACN Settings, press the ENTER button to confirm. Use the UP/DOWN button to select
sACN Universe or sACN Priority, press the ENTER button to store. Press the MENU button back to
the last menu or let the unit idle 30 seconds to exit menu mode.
Artnet to DMX
To select Artnet to DMX, press the ENTER button to confirm. Use the UP/DOWN button to select
No or Yes, press the ENTER button to store. Press the MENU button back to the last menu or let the
unit idle 30 seconds to exit menu mode.
View DMX Value
To select View DMX Value, press the ENTER button to confirm. Use the UP/DOWN button to view
the DMX channel value. Press the MENU button back to the last menu or let the unit idle 30
seconds to exit menu mode.
Fixture Settings
To select Fixture Settings, press the ENTER button to confirm, use the UP/DOWN button to select
Pan Invert, Tilt Invert, P/T Feedback, Dimmer Speed, Dimmer Curve, Cooling Mode, Bright
Calibration, CCI Calibration or Blade Mode.
Pan Invert
To select Pan Invert, press the ENTER button to confirm. Use the UP/DOWN button to select No
(normal) or Yes (pan invert), press the ENTER button to store. Press the MENU button back to the
last menu or let the unit idle 30 seconds to exit menu mode.
Tilt Invert
To select Tilt Invert, press the ENTER button to confirm. Use the UP/DOWN button to select No
(normal) or Yes (tilt invert), press the ENTER button to store. Press the MENU button back to the
last menu or let the unit idle 30 seconds to exit menu mode.
P/T Feedback
To select P/T Feedback, press the ENTER button to confirm. Use the UP/DOWN button to select No
(Pan or tilt’s position will not feedback while out of step) or Yes (Feedback while pan/tilt out of step),
press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle
30 seconds to exit menu mode.
13A

Dimmer Speed
To select Dimmer Speed, press the ENTER button to confirm. Use the UP/DOWN button to select
Fast or Smooth, press the ENTER button to store. Press the MENU button back to the last menu or
let the unit idle 30 seconds to exit menu mode.
Dimmer Curve
To select Dimmer Curve, press the ENTER button to confirm. Use the DOWN/UP button to select
Square Law, Inv SQ Law, Linear or S Curve, press the ENTER button to store. Press the MENU button
back to the last menu or let the unit idle 30 seconds to exit menu mode.
Optically Linear: The increase in light intensity appears to be linear as DMX value is increased.
Square Law: Light intensity control is finer at low levels and coarser at high levels.
Inverse Square Law: Light intensity control is coarser at low levels and finger at high levels.
S-Curve: Light intensity control is finger at low levels and high levels and coarser at medium levels.
Cooling Mode
To select Cooling Mode, press the ENTER button to confirm. Use the UP/DOWN button to select
Standard, Quiet or Theatre, press the ENTER button to store. Press the MENU button back to the
last menu or let the unit idle 30 seconds to exit menu mode.
Bright Calibration
To select Bright Calibration, press the ENTER button to confirm. Use the UP/DOWN button to adjust
the value from 50 to 100, press the ENTER button to store. Press the MENU button back to the last
menu or let the unit idle 30 seconds to exit menu mode.
14A

CCI Calibration
To select CCI Calibration, press the ENTER button to confirm. Use the UP/DOWN button to select
State or Value, press the ENTER button to store. Select State, press the ENTER button to confirm.
Use the UP/DOWN button to select Off or On, press the ENTER button to store. Select Value, press
the ENTER button to confirm. Use the UP/DOWN button to adjust the value from 0to 100, press
the ENTER button to store. Press the MENU button back to the last menu or let the unit idle 30
seconds to exit menu mode.
Blade Mode
To select Blade Mode, press the ENTER button to confirm. Use the UP/DOWN button to select
Mode 1 or Mode 2, press the ENTER button to store. Press the MENU button back to the last menu
or let the unit idle 30 seconds to exit menu mode.
Display Settings
To select Display Settings, press the ENTER button to confirm, use the UP/DOWN button to select
Display Invert, Backlight Intensity, Temperature Unit or Language.
Display Invert
Select Display Invert, press the ENTER button to confirm. Use the UP/DOWN button to select No
(normal display) or Yes (invert display), press the ENTER button to store. Press the MENU button
back to the last menu or let the unit idle 30 seconds to exit menu mode.
Backlight Intensity
Select Backlight Intensity, press the ENTER button to confirm. Use the UP/DOWN button to adjust
the backlight intensity from 1 (dark) to 10 (bright), press the ENTER button to store. Press the
MENU button back to the last menu or let the unit idle 30 seconds to exit menu mode.
Temperature Unit
Select Temperature Unit, press the ENTER button to confirm. Use the UP/DOWN button to
select
℃
or
℉
, press the ENTER button to store. Press the MENU button back to the last menu or
let the unit idle 30 seconds to exit menu mode.
Language
Select Language, press the ENTER button to confirm. Use the UP/DOWN button to select English or
Chinese, press the ENTER button to store. Press the MENU button back to the last menu or let the
unit idle 30 seconds to exit menu mode.
15A

F ixture Test
To select Fixture Test, press the ENTER button to confirm, use the UP/DOWN button to select Auto
Test or Manual Test.
Auto Test
Select Auto Test, press the ENTER button to confirm, the unit will run built-in programs to
automatically test pan, tilt, color, gobo, gobo rotation, prism, prism rotation, iris, frost, zoom, focus,
etc. Press the MENU button back to the last menu or exit menu mode after auto test.
Manual Test
Select Manual Test, press the ENTER button to confirm, the present channel will show on the
display, use the UP/DOWN button to select Clear, Pan, Tilt, Cyan, Magenta, Yellow, CTO, Color,
Color2, Gobo, RGobo1, Gobo2, Animation, Iris, Prism, RPrism, Frost1, Frost2, Zoom, Focus, Strobe,
Dimmer, Blade, DladeDown1, DladeDown2, BladeUp1, BladeUp2, BladeLeft1, BladeLeft2,
BladeRight1 or BladeRight2,press the ENTER button to confirm, use the UP/DOWN button to
adjust the value from 0 to 255, press the ENTER button to store. Press the MENU button back to the
last menu or let the unit idle 30 seconds to exit menu mode.
(The fixture will return to the previous DMX state after exiting Manual Test menu and the Manual
Test parameters will be automatically saved after power off and restart.)
Fixture Information
To select Fixture Information, press the ENTER button to confirm, use the UP/DOWN button to
select Fixture Use Hour, LED Use Hour, Temperature, Upgrade File, Fan State, Firmware Version,
RDM UID or Error Logs.
Fixture Use Hour
Select Fixture Use Hour, press the ENTER button to confirm, fixture use hour will show on the
display, press the MENU button to exit.
LED Use Hour
To select LED Use Hour, press the ENTER button to confirm, use the UP/DOWN button to select
Total LED Hour, LED On Hour or LED Hours Reset, press the ENTER button to store. To select LED
Hours Reset, press the ENTER button to confirm, use the UP/DOWN button to select No or Yes,
press the ENTER button to store. To select Yes, press the ENTER button to confirm, use the
UP/DOWN button to set the password 050 to reset the LED hours, press the ENTER button to store.
Press the MENU button back to the last menu or exit menu mode let the unit idle 30 seconds.
16A

Temperature
Select Temperature, press the ENTER button to confirm. Use the UP/DOWN button to select LED’s
or CPU’s, press the ENTER button to store, LED’s or CPU’s current temperature and max
temperature of the fixture will show on the display, press the MENU button to exit.
Upgrade File
Select Upgrade File, press the ENTER button to confirm, upgrade file will show on the display, press
the MENU button back to exit.
Fan State
Select Fan State, press the ENTER button to confirm, fan state will show on the display, press the
MENU button to exit.
Firmware Version
Select Firmware Version, press the ENTER button to confirm, firmware version will show on the
display, press the MENU button back to exit.
RDM UID
Select RDM UID, press the ENTER button to confirm, RDM UID will show on the display, press the
MENU button back to exit.
Error Logs
Select Error Logs, press the ENTER button to confirm. Use the UP/DOWN button to select Fixture
Errors or Reset Error Log, press the ENTER button to store. Select Reset Error Log, press the ENTER
button to confirm. Use the UP/DOWN button to select No or Yes, press the ENTER button to store.
Select Yes, press the ENTER button to confirm. Use the UP/DOWN button to set the password 050,
press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle
30 seconds to exit menu mode.
Reset Function
To select Reset Function, press the ENTER button to confirm, use the UP/DOWN button to select
Pan/Tilt Reset, Effect Reset or All Reset.
Pan/Tilt Reset
Select Pan/Tilt Reset, press the ENTER button to confirm, use the UP/DOWN button to select
No(normal) or Yes (the unit will run built-in program to reset pan and tilt to their home positions),
press the ENTER button to store. Press the MENU button back to the last menu or let the unit idle
30 seconds to exit menu mode.
17A

Effect Reset
Select Effect Reset,press the ENTER button to confirm, use the UP/DOWN button to select
No(normal) or Yes (the unit will run built-in program to reset effect to their home positions), press
the ENTER button to store. Press the MENU button back to the last menu or let the unit idle 30
seconds to exit menu mode.
All Reset
Select All Reset,press the ENTER button to confirm, use the UP/DOWN button to select No(normal)
or Yes (the unit will run built-in program to reset all motors to their home positions), press ENTER
button to store. Press the MENU button to exit.
Special Function
Factory Settings
Select Factory Settings,press the ENTER button to confirm, use the UP/DOWN button to select
No(normal) or Yes (the fixture will reset to factory settings), press ENTER button to store. Press the
MENU button to exit.
RDM FUNCTIONS
Select the MANUFACTURER menu to display the manufacturer of the fixture.
Select the SOFTWARE VERSION menu and the program version number of the fixture will be
displayed.
Select the DMX START ADDRESS menu to change the DMX 512 address (001-512).
Select the DEVICE MODEL DESCRIPTION menu to display the model of the fixture.
Select the DEVICE LABEL menu to change the model of the fixture.
Select the DMX PERSONALITY menu to set the channel mode of the fixture (37/2 8/3 1/2 2 channel).
Select the DMX PERSONALITY DESCRIPTION menu to display the current channel mode of the
fixture.
Select the DEVICE HOURS menu to display the running time of the fixture.
Select the PAN INVERT menu and the fixture will run the pan invert mode.
Select the TILT INVERT menu and the fixture will run the tilt invert mode.
Select the RESET DEVICE menu, the WARM RESET/COLD RESET option will be displayed. When
WARM RESET is selected, the fixture will start a warm reset, and exit when COLD RESET is selected.
18A

5.2 Home Position Adjustment
Press the MENU button into menu mode, then press the ENTER button for about 3 seconds into
offset mode to adjust the home position. Select the function by pressing the ENTER button. Use the
UP/DOWN button to choose the submenu, press the ENTER button to store and automatically
return to the last menu. Press MENU button to exit.
19A
This manual suits for next models
2
Table of contents
Other ACME Light Fixture manuals

ACME
ACME XP-5000 SZ NF User manual

ACME
ACME GEIST BEAM User manual

ACME
ACME led-st05 User manual

ACME
ACME CM-70Z User manual

ACME
ACME MH-6616S User manual

ACME
ACME GLAMOUR 700Z RGBY User manual

ACME
ACME Xperior 5R BEAM F User manual

ACME
ACME LED?MS700PE User manual

ACME
ACME LED-MB500 User manual

ACME
ACME Xperior XP-16R BEAM II User manual