ADC Adtemp TempleTouch 427 User manual

AdtempTM 427
TempleTouchTM
Thermometer
Instructions
for Use
Thank you for choosing an ADC®AdtempTM Temple Touch thermometer.
Your new thermometer is designed to provide accurate body temperature
measurements using a unique probe, which measures the heat flow from
the blood vessels to the skin and converts it to body temperature in
approximately 6-8 seconds.
Parts and Assembly
Symbol Definitions
The following symbols are associated with your thermometer.
Specifications
Feature performance / data: Measurement time 6-8 seconds
Measurement location: Temple area of the forehead
Measurement range: 95°F to 107.6°F (35°C to 42°C)
Operation environment: 60.8°F to 104°F (16° C to 40° C)
Humidity: 15-95% (non condensing)
Storage environment: -4°F to 122°F (-20° C to 50° C)
Humidity: 15-95% (non condensing)
Measurement readout: Celsius or Fahrenheit
Accuracy: Complies with ASTM E 1112-00 standard requirements
Display: TN LCD 0.63" X 0.44" (16 mm X 11 mm)
Battery: 2 AAA 1.5V batteries
Battery life: Minimum 1000 full duty cycles over 24 month period
Weight: 1.3 oz (37 gr) including batteries
Dimensions: 4.7" x 1.17" x 1" (12 cm x 3.0 cm x 2.4 cm )
Memory: Last-reading display when turned on
Auto shut off: After 60 seconds
Case material: Medical grade ABS plastic
Probe material: Medical grade stainless steel, medical grade ABS plastic
Warranty: 2 year
Standards:
Complies with EN 12470-3 and ASTM E 1112-00
IB p/n 93-427-00 rev 7 (10/19/2020)
Display Window
Multifunction Button
Non-invasive
Sensor
LIMITED WARRANTY
ADCwarrants its products against defects in materials and workmanship under normal household use and service as follows:
1. Warranty service extends to the original retail purchaser only and commences with the date of delivery.
2. Your Adtemp TempleTouch Thermometer is warranted for two years from date of purchase.
What Is Covered: Replacement of parts, and labor.
What Is Not Covered: Transportation charges to ADC. Damages caused by abuse, misuse, accident, or negligence.
Incidental, special, or consequential damages. Some states do not allow the exclusion or limitation of incidental, special,
or consequential damages, so this limitation may not apply to you.
To Obtain Warranty Service: Send item(s) postage paid to ADC, Attn: Repair Dept., 55 Commerce Dr., Hauppauge,
NY 11788. Please include your name and address, phone no., proof of purchase, and a brief note explaining the problem.
Implied Warranty: Any implied warranty shall be limited in duration to the terms of this warranty and in no case beyond
the original selling price (except where prohibited by law). This warranty gives you specific legal rights and you may have
other rights which vary from state to state.
For Australian Consumers: Our goods come with guarantees that cannot be excluded under the Australian Consumer
Law. You are entitled to a replacement or refund for a major failure and compensation for any other reasonable foreseeable
loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and
the failure does not amount to a major failure.
This manual is available online in a
variety of languages,
follow the links for language options.
www.adctoday.com/care
To register your product visit us at
www.adctoday.com/register
EC REP
2797
Medisim Ltd.
Hamelacha 11, Ind. Park Hartov A
Beit-Shemesh
9980101
Israel
Arazy Group GmbH
The Squaire 12, Am Flughafen
60549 Frankfurt am Main
Germany
Distributed by: ADC®
55 Commerce Drive
Hauppauge NY 11788
Made in Israel
www.adctoday.com
Patent #7597668
Symbol Definition
Important warning/caution
Not made with natural rubber latex
Phthalate free
Keep dry
Operating instructions
Manufacturer’s information
Authorized European
representatives information
Dispose in accordance with local
applicable regulations
LATEX
Symbol Definition
Meets essential requirements of
European Medical Device Directive 93/42/EEC
Lot number
Multifunction button
Auto detection error
Temperature is higher than measuring
range
Temperature is lower than measuring
range
Memory indication
Low battery indication
M
2797
LATEX
93-427-00 rev 7.qxp_Layout 1 10/20/20 12:42 PM Page 1

General Warnings:
•High, prolonged fever requires medical attention, especially for young children. Please contact your physician.
• Keep out of reach of unsupervised children. Components may be harmful if swallowed.
• Read the enclosed instructions carefully to ensure accurate temperature readings. Temperature readings
are affected by many factors including exercise, drinking hot or cold beverages prior to taking a reading as
well as technique.
• WARNING: It is recommended to remove the batteries from the thermometer when it is not used
for a long period. Do not dispose of batteries in fire, recharge, put in backwards, disassemble, mix
with used or other battery types – they may explode or leak and cause injury. Waste batteries should be
deposited in a batteries recycling trash only.
• CAUTION: Do not drop the thermometer or expose to heavy shock.
• CAUTION: Do not immerse thermometer in water or any other liquid.
• CAUTION: Do not store the unit in direct sunlight, at a high temperature, in high humidity or dust.
• CAUTION: Stop using the thermometer if it operates erratically or if display malfunctions.
• CAUTION: Clean the thermometer probe before storing.
• CAUTION: Do not attempt to disassemble the unit except to replace the batteries.
• CAUTION:
Do not autoclave. Please note the cleaning procedures described in this manual.
How to Use:
Use this thermometer on a clean, dry forehead. Wipe away any perspiration and move any
hair away from the temporal area.
1. Press and release the multifunction button. The display will flash and you’ll hear a
single audible beep (Figure 1). The previous result will display for 2 seconds (Figure 2)
then disappear.
2. Place the thermometer's probe in the center of the temple area between the end of
the eyebrow and the hairline. Hold the unit gently but firmly against the temple to
ensure good contact with the skin. (Figure 3). Correct placement and good contact
ensure reliable readings.
3. Once the thermometer is in place, the measurement will start automatically. A running
circle will appear indicating that the measurement is progressing successfully (Figure 4).
Make sure that the thermometer and the patient do not move while measurement is in
progress.
4. A temperature reading will be displayed within 6-8 seconds. You’ll hear one long beep
when the measurement is complete. The reading will remain displayed for about 1
minute. The unit will turn off automatically in about one minute. To prolong battery life,
press the multifunction button to turn off manually.
NOTE: You must wait one minute before taking another reading. If you try to begin another reading
before this time has elapsed (by manually turning the device off and on), the unit will display a
10-second countdown while it resets. If you attempt to measure during the countdown,
the device will display the previous result, beep 8 times and turn itself off automatically.
Ensuring Accurate Temperature Measurement:
1. Measurement body location is the temple, in proximity to the temporal artery, between the end of
the eyebrow and hairline.
2. Do not place the thermometer on scarred tissue compromised by skin disorder, open sores or
abrasions, or patients in trauma.
3. Temperature readings are affected by many factors including exercise and drinking hot or cold
beverages prior to taking a reading.
4. Consult your physician when using drug therapies that may raise the local skin temperature in the
forehead; this may lead to an incorrect reading.
5. Do not place the thermometer on skin exposed to direct sunlight, fireplace heat, air conditioner
flow, or cold/warm compress therapies.
6. Wait at least one minute between consecutive measurements for the unit to readjust to
room temperature.
7. If the thermometer has been stored at a cold temperature, allow the unit to warm naturally to
room temperature before using.
8. Performance may be degraded if operated or stored outside stated temperature/humidity ranges.
Switching Temperature Modes:
The default temperature scale is Fahrenheit (°F). To change the scale to °C, or back to °F:
1. While off, press and hold the multifunction button for about five seconds. The hourglass
icon will display, then the °F or °C will change.
2. Release the button.
Battery Replacement:
With the device off, remove the battery cover by sliding it out of its housing. Place the batteries in the
chamber, making sure polarity is correct (see engraving on the bottom of battery compartment).
Slide the battery cover back into place.
Troubleshooting:
The thermometer has been designed to display feedback warnings to ensure proper usage and accurate
temperature measurement. When an error appears, the device will beep 5 times and then turn off automatically. In
the event of a malfunction or incorrect temperature measurement, the following warnings will be displayed:
HI: If the measured temperature is above 107.6°F (42°C) the device will beep and display HI.
Remedy: Turn the unit off, wait 1 minute, and then turn on again. Retake temperature using
proper technique. If still reads HI, this indicates that the patient has a high fever. Seek immediate
medical attention. NOTE: This is not a device malfunction.
LO: If the measured temperature is below 95°F (35°C) the device will beep and display LO.
Remedy: Turn the unit off, wait 1 minute, and then turn on again. Retake temperature using
proper technique. If still reads LO, this indicates that the patient has a low body temperature.
NOTE: This is not a device malfunction.
Er.1: If the thermometer is too cold or too hot to operate, the device will beep 5 times and
display Er.1.
Remedy: Verify room temperature is within product range 60.8°F-104°F (16° C - 40° C).
Wait 1 minute and then retake temperature using proper technique.
Er.2: If the temperature did not register because of poor contact, patient movement, or poor
placement, the device will beep 5 times and display Er.2.
Remedy: Turn the unit off, wait 1 minute, then turn it on again. Retake temperature using
proper technique.
Er.3: If the unit malfunctioned, the device will beep 5 times and display Er.3.
Remedy: Do not use the thermometer. Call 1-800-232-2670 for service.
Low Battery: Battery icon is on continuously.
Remedy: The battery has enough remaining life for approximately 10 more measurements.
Replace battery soon.
Drained Battery: Battery icon appears as unit is turned on and the device turns itself off.
Remedy: Replace battery.
Cleaning and Disinfecting:
• Wipe the tip and probe with a cotton swab moistened with 70% isopropyl alcohol before and after
each use. After cleaning, wait at least 2 minutes before taking a measurement for the unit to re-adjust
to room temperature.
• Use only a soft dry cloth to clean the body of the thermometer (if necessary). Never use an abrasive
cleanser or submerge the thermometer in water or other liquids.
Figure 1
Figure 2
Figure 3
Figure 4
93-427-00 rev 7.qxp_Layout 1 10/20/20 12:42 PM Page 2
Other ADC Thermometer manuals

ADC
ADC Adtemp V 418N Maintenance manual

ADC
ADC Adtemp II 413B-00 Maintenance manual

ADC
ADC Adimals 426 User manual

ADC
ADC Adtemp 433 User manual

ADC
ADC Adtemp Temple Touch 427 User manual

ADC
ADC Adimals 426 Manual

ADC
ADC Adimals 426 User manual

ADC
ADC Adtemp 424 User manual

ADC
ADC Adtemp II 413 Maintenance manual

ADC
ADC Adtemp 423 User guide

ADC
ADC Adtemp 427 Temple Touch Maintenance manual

ADC
ADC Adtemp 412 User manual

ADC
ADC Adtemp ULTRA 417 User manual

ADC
ADC Adtemp V 418 Owner's manual

ADC
ADC Adtemp 429 User manual

ADC
ADC Adtemp 413 User manual

ADC
ADC Adtemp 413 User manual

ADC
ADC Adtemp 418N User manual

ADC
ADC ADTEMP 421 User manual

ADC
ADC Adtemp 415FL User manual