ADC Adimals 426 User manual

Figure 1
Power button
Battery cover
LCD display
Flexible
probe
Thank you for choosing our Adimals digital thermometer. Your new thermometer is
designed to provide accurate body temperature measurements. Our thermometers meet
or exceed all relevant international performance standards.
Device Description and Intended Use
A digital thermometer is a device used to measure the body temperature of a patient by
means of a transducer coupled with an electric signal amplification, conditioning,
and display unit.
Parts and Assembly
Symbol Definitions
The following symbols are associated with your thermometer.
General Warnings
A warning statement in this manual identifies a condition or practice which,
if not corrected or discontinued immediately, could lead to patient injury, illness,
or death. The thermometer is safe for patients and clinicians when used in
accordance with the instructions and with the warning and caution statements
in this manual. Before using the thermometer, familiarize all operating personnel
with the general safety instructions provided in this manual.
WARNING:
Use of this device is not intended to be a substitute for consultation with your
physician.
WARNING:
Avoid taking temperature for 30 minutes after physical exercise, bathing,
dining, or drinking hot or cold beverages.
WARNING:
High prolonged fever requires medical attention especially for young children.
Contact your physician.
WARNING:
Do not allow children to walk or run during temperature taking. The probe could
present a hazard.
WARNING:
Oral, axillary, and rectal temperatures vary by approximately 1°F (0.5°C).
WARNING:
Keep battery out of children’s reach. Swallowing battery could be harmful.
Battery should not be recharged or placed into extreme heat as it may explode.
CAUTION:
Do not boil, bite, bend, drop, or disassemble the thermometer.
CAUTION:
Keep thermometer away from direct sunlight, extreme temperatures, or dust.
CAUTION:
Do not take axillary temperature through patient’s clothing. Direct probe cover to
skin contact is required.
CAUTION:
Do not autoclave. Please note the cleaning procedures described in this manual.
How to Use
1.Place a probe cover carefully over the tip (Figure 1).
2.Push the Power button to turn the unit on. The LCD window will briefly display
as an internal test. The unit will then briefly display the last read temperature.
3.The unit is ready for a temperature reading when is displayed.
An message in the window indicates your unit is not functioning properly.
The °F/°C symbol will flash during the duration of the measurement time.
4.The unit will beep when the reading is complete in approximately 10 seconds.
If you remove the thermometer early, the LCD will display and the unit will beep.
Turn the unit off and back on to take a new reading.
5.Push the Power button to turn the unit off. This will prolong the battery life.
If you do not turn the unit off, it will shut off automatically in approximately 1 minute.
Ensuring Accurate Temperature Measurement
We recommend using probe covers with all digital stick
thermometers (Figure 1).
Oral Use (for children 4 years and older):
Place the probe well under the patient’s tongue (Figure 2). Keep
mouth closed while thermometer is reading. Instruct children not to
bite down on the probe. The peak temperature should be reached
in approximately 10 seconds, and will make a continuous beeping
sound. Opening the mouth or improper placement of the probe tip
could result in a longer time for a reading.
Rectal Use
(Commonly used for babies, young children or when it is difficult to take an oral or
underarm temperature):
Lubricate the probe cover with a water-soluble jelly for easier insertion; do not use
petroleum jelly, as it may cause an inaccurate reading. Gently insert the tip of the probe
no more than a 1/2 inch into the rectum. The peak temperature should be reached in
approximately 10 seconds, and will make a continuous beeping sound.
STOP if you meet any resistance. The sensing unit is on the very tip of the probe and there
is no need to insert the probe deep into the rectum. Dispose of the used probe cover and
clean the thermometer as recommended.
ADC®Adimals®
Digital Thermometer
Model 426
Instructions
for Use
Symbol Definition
Important warning/caution
Phthalate free
Keep dry
Operating instructions
Type BF applied part
Lot number
LATEX
Symbol Definition
Manufacturer’s information
Authorized European representative’s
information
Meets essential requirements of
European Medical Device Directive
93/42/EEC
Dispose in accordance with regulations
Low battery indication
Medical device
Not made with natural rubber latex
2460
LOT
188.8 °F
Lo °F
E
rr
--- °F
Figure 2
93-426-00 rev 3.qxp_Layout 1 12/1/21 10:18 AM Page 1

Underarm (Axillary) Use:
Wipe armpit with a dry towel. Place the probe in the patient’s armpit
(Figure 3) and keep the patient’s arm pressed firmly against the
body. The time required for an accurate underarm temperature may
be 10 seconds or longer depending on placement of the probe and
closure of the arm against the body.
How to Change the Measurement Scale
1.Turn the unit off.
2.Hold Power until the LCD displays either or .
3.Push the Power button to switch between °F and °C. After two seconds, the unit will set
to the currently displayed scale. When is displayed, the unit is ready to take a
temperature.
Replacing the Battery
1. When the unit displays “ ”, the battery needs to be replaced.
2. With the unit off, carefully unscrew the battery cover, slide
it off, and remove the old battery (Figure 4).
3. Insert a new LR41 battery with the “+” symbol facing back
of thermometer.
4. Replace the battery cover before turning unit back on.
Error Indications
The measured temperature is above 109.4°F (43°C), LCD displays "Hi."
Retake temperature using proper technique.
The measured temperature is below 89.6°F (32°C), LCD displays "Lo."
Retake temperature using proper technique.
The battery needs to be replaced.
The thermometer was removed before a temperature was taken.
Retake temperature.
There is a problem with the thermometer. Please contact your retailer.
Cleaning and Disinfecting
Do not use corrosive detergent to clean the unit.
Clean and disinfect the thermometer before and after each use.
Cleaning Process
• Use of probe covers is recommended to help avoid spreading germs, and to keep the
thermometer clean. The thermometer should be cleaned after use even when probe
covers are used.
• Wipe probe with a cloth dipped in a disinfectant solution such as 70% isopropyl
(rubbing) alcohol or soap and water.
• Rinse off disinfectant residue.
Care and Storage
• Do NOT drop or crush; this device is not shock proof.
• Do NOT dismantle or modify device.
• Do NOT store the device in an extreme environment with direct sunlight or high
temperatures.
• Store the unit in the protective case while not in use.
Standards
Complies with IEC60601-1:2006, IEC60601-1-2:2007, EN 12470-3:2000 and
ASTM E 1112-00.
Limited Warranty
This product is warranted against defects in materials and workmanship under normal use and
service as follows:
1. Warranty service extends to the original retail purchaser only and commences with the
date of delivery.
2. Your Adimals digital thermometer is warranted for two years from date of purchase.
What Is Covered: Replacement of parts, and labor.
What Is Not Covered: Transportation charges to Service Center. Batteries where supplied.
Damages caused by abuse, misuse, accident, or negligence. Incidental, special, or consequential
damages. Some states do not allow the exclusion or limitation of incidental, special, or conse-
quential damages, so this limitation may not apply to you.
To Obtain Warranty Service: Send item(s) postage paid to ADC Service Center, 55 Commerce
Dr., Hauppauge, NY 11788. Please include your name and address, phone no., proof of purchase,
and a brief note explaining the problem.
Implied Warranty: Any implied warranty shall be limited in duration to the terms of this warranty
and in no case beyond the original selling price (except where prohibited by law). This warranty
gives you specific legal rights and you may have other rights which vary from state to state.
For Australian Consumers: Our goods come with guarantees that cannot be excluded under
the Australian Consumer Law.You are entitled to a replacement or refund for a major failure and
compensation for any other reasonable foreseeable loss or damage. You are also entitled to have
the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does
not amount to a major failure.
IB p/n 93-426-00 rev 3 (11/16/21) Printed in Taiwan
LATEX
Specifications
Measurement Range: 89.6°F ~ 109.4°F (32.0°C ~ 43.0°C)
Accuracy: ±0.3°F / 89.6°F ~ 95.7°F (±0.2°C / 32.0°C ~ 35.4°C)
±0.2°F / 95.9°F ~ 107.6°F (±0.1°C / 35.5°C ~ 42.0°C)
±0.3°F / 107.8°F ~ 109.4°F (±0.2°C / 42.1°C ~ 43.0°C)
(When measured at a standard room temperature of 73.4°F (23°C) in the water bath)
Display Unit: 0.1°F (0.1°C)
Storage Conditions: -13°F ~ 158°F (-25°C ~ 70°C) / 15% - 90% RH
Operating Conditions: 50°F ~ 104°F (10°C ~ 40°C) / 15% - 90% RH
Battery: 1.55V (LR41)
Battery Life: Estimated 4,000 uses
(more than 200 hours of continuous use)
Display: LCD Liquid Crystal Display
Weight: 0.71 oz (20g) including battery
Dimensions: 6.1'' x 1.2'' x .66'' (155.5mm x 32.5mm x 17mm)
Measurement Time: Oral, Rectal, Axillary 10 seconds
Audible Alarm: Notified beeper for ready and finished measurements
The fever alarm will sound with short beeps at 100°F (37.8°C)
Memory: Stores last temperature taken
Auto Off: After 1 minute
The manufacturer recommends verifying the accuracy of the unit by an authorized laboratory every 2 years.
Read the instruction manual carefully before using
this device, especially the safety instructions, and
keep the instruction manual for future use.
Batteries and electronic devices must be disposed
of in accordance with the locally applicable
regulations, not with domestic waste. 2460
EC REP
C F
Lo
°F
Figure 4
E
rr
--- °F
H
i
°F
Geon Corporation
No. 12, Gung Ye Road, Hsi Hu
Chang Hwa Hsien, Taiwan
MYM STC, SL.
Avda. de los Rosales,
32, 28935 Móstoles
Madrid, Spain
Distributed by: ADC®
55 Commerce Drive
Hauppauge, NY 11788
Inspected in the U.S.A.
tel: 631-273-9600
toll free: 1-800-232-2670
fax: 631-273-9659
www.adctoday.com
email: info@adctoday.com
Made in Taiwan
Figure 3
Lo
°F
93-426-00 rev 3.qxp_Layout 1 12/1/21 10:18 AM Page 2
Table of contents
Other ADC Thermometer manuals

ADC
ADC Adtemp 424 Maintenance manual

ADC
ADC Adtemp 423 User guide

ADC
ADC Adtemp 424 User manual

ADC
ADC Adimals 426 Manual

ADC
ADC Adtemp V 418 Maintenance manual

ADC
ADC Adtemp V 418 Maintenance manual

ADC
ADC Adtemp 413 User manual

ADC
ADC Adtemp 412 User manual

ADC
ADC Adtemp II 412 Maintenance manual

ADC
ADC Adtemp 429 User manual

ADC
ADC Adtemp 427 TempleTouch User manual

ADC
ADC Adtemp 413 User manual

ADC
ADC Adtemp 418N User manual

ADC
ADC Adtemp V 418 Owner's manual

ADC
ADC Adtemp TempleTouch 427 User manual

ADC
ADC Adtemp V 418N User manual

ADC
ADC Adtemp Mini 432 User manual

ADC
ADC Adtemp 427 Temple Touch Maintenance manual

ADC
ADC Adimals 426 User manual

ADC
ADC Adtemp 433 User manual