AdtempTM 413
Digital Stick Thermometer
Instructions for se
Thank you for choosing an ADC®AdtempTM digital stick thermometer. Your new
thermometer is designed to provide accurate measurements. Adtemp thermometers
meet or exceed all relevant international performance standards.
Device Description and Intended se
This device is intended to measure human body temperature in children and adults.
t has a compact size and digital display and can be used in a professional or house-
hold environment.
Parts and Assembly
Symbol Definitions
The following symbols are associated with your thermometer.
General Warnings
A warning statement in this manual identifies a condition or practice which, if
not corrected or discontinued immediately, could lead to patient injury,
illness, or death.
WARNING:
This instrument is designed for oral, rectal, or axillary use only.
WARNING:
High prolonged fever requires medical attention, especially for young children.
Please contact your physician.
WARNING:
Keep out of reach of unsupervised children. Components may be harmful if swallowed.
WARNING:
Stop using the thermometer if it operates erratically or if the display malfunctions.
WARNING:
Oral temperature readings are usually 0.5°F. to 1.0°F degree lower than rectal readings;
axillary readings are generally 0.5°F to 1.0°F lower than oral readings.
Symbol Definition
mportant warning/caution
Phthalate free
Operating instructions
Manufacturer’s information
Authorized European representative’s
information
Type BF applied part
LATEX
Symbol Definition
Meets essential requirements of European
Medical Device Directive 93/42/EEC
Lot number
Multifunction button
Auto detection error
Memory indication
Low battery indication
Separate collection for waste of
electrical and electronic equipment.
Not made with natural rubber latex
Probe Tip Display Window Multifunction Button
Battery
Cover
1639
WARNING:
Avoid taking temperature for 30 minutes after physical exercise, bathing,
dining, or drinking hot or cold beverages.
WARNING:
Allow the thermometer to warm naturally to room temperature before using.
Performance may be affected if operated or stored outside stated temperature and humidity ranges
or if the patient's temperature is below the ambient (room) temperature.
WARNING:
After using, clean the thermometer and place it into the case. Clean the unit by wip-
ing it with a dry cloth and disinfect the probe with isopropyl (rubbing) alcohol. See cleaning in-
structions for additional details.
CAUTION:
Keep thermometer away from direct sunlight, extreme temperatures, or dust.
CAUTION:
Do not boil, bite, bend, drop, or disassemble the thermometer.
CAUTION:
Do not open the unit except to replace the battery.
CAUTION:
Do not use this device close to strong electromagnetic fields, such as mobile tele-
phones.
CAUTION:
Do not autoclave. Please note the cleaning procedures described in this manual.
CAUTION:
Dispose of batteries in accordance with locally applicable regulations, not with
domestic waste.
CAUTION:
P22: Protected against solid foreign objects of 12.5mm diameter and greater. Protected
against vertically falling water drops when the device is tilted up to 15°.
How to se
1. Disinfect the probe with isopropyl (rubbing) alcohol before using.
2. Press and release the multifunction button. The display will read
confirming the unit is functioning properly. The last measured temperature will be
displayed for approximately 2 seconds. Next the thermometer will read L °F, (or L °C).
3.
We recommend using probe covers with all digital stick thermometers. f using, place
cover over tip of unit.
4. Place the probe in the appropriate position for your measurement site (see
Ensuring Accurate Temperature Measurement below).
5. The °F or °C symbol will flash when the unit is ready to measure temperature.
Please note that the “ ” indicates a low battery. See instructions for replacing
battery before measuring temperature. Do not expect an accurate temperature
reading if this low battery indicator is present. An “ERR” message in the
window indicates your unit is not functioning properly.
6. Depending on the measurement site, the unit will complete measurement in
approximately 30-40 (oral), 25-35 (rectal), or 90 (axillary) seconds. The display
will flash and the unit will beep signaling completion.
7. Read and record the temperature and time for reference. The reading will automatically
be stored in the memory.
8. The unit will automatically turn off in about 8 minutes. To prolong battery life,
press the multifuction button to turn off the device manually.
Switching Temperature Modes
From the OFF position, the Celsius or Fahrenheit mode can be switched by pressing
and holding the multifunction button for at least 5 seconds. After 3 seconds in one
scale the °F or °C will flash, indicating ready to measure.
Ensuring Accurate Temperature Measurement
We recommend using probe covers with all digital stick
thermometers (Figure 1).
Oral Use: Place the probe well under the patient’s tongue
(Figure 2). Keep mouth closed while thermometer is reading.
nstruct children not to bite down on the probe. The peak
temperature should be reached in as little as 30* seconds.
Opening the mouth or improper placement of the probe tip
could result in a longer time for a reading.
(*30 second response time achieved in water bath test)
Rectal Use: Lubricate the probe cover with a water-
soluble jelly for easier insertion; do not use petroleum jelly, as it may cause an
inaccurate reading. Gently insert the tip of the probe no more than 1/2 inch into
the rectum.
F
K
E
1
1
Figure 1
Figure 2
STOP if you meet any resistance. The sensing unit is on the very tip of the probe
and there is no need to insert the probe deep into the rectum.
Dispose of the used probe cover and wash the thermometer as recommended. The
peak temperature should be reached in approximately 25-35 seconds.
Axillary Use: Wipe armpit with a dry towel. Place the probe
in the patient’s armpit (Figure 3) and keep the patient’s arm
pressed firmly against the body. n order to achieve a better
axillary reading, a minimum measuring time of 90 seconds or
longer is recommended, depending on placement of the probe
and closure of the arm against the body.
Battery Replacement
1. When the symbol “ ” appears, the battery needs to
be replaced.
2. Remove battery compartment lid (Figure 4).
3. Use a pointed object such as a toothpick to pry loose the
old battery. Avoid using any sharp metal object.
4. Place new 1.55V coin-type battery (LR41 or equivalent) in the chamber with the
positive (+) side facing up or towards the display of the unit.
5. Replace the battery compartment lid.
Cleaning and Disinfecting
Do not use corrosive detergent to clean the unit.
Clean and disinfect the thermometer before and after each use.
Cleaning Process
1. Wipe probe with a cloth dipped in a disinfectant solution such as 70%
isopropyl (rubbing) alcohol or soap and water.
2. Rinse off disinfectant residue.
Care and Storage
• Do NOT drop or crush; this device is not shock proof.
• Do NOT dismantle or modify device other than replacing the battery.
• Do NOT store the device in an extreme environment with direct sunlight or high
temperatures.
• Store the unit in the protective case while not in use.
Figure 3
Figure 4
BATT E RY
Specifications
Size: 5”L x 3/4”W x 3/8”H (12.7cm L x 1.9 cm W x .95 cm H)
Weight: 0.388 oz. (11 grams)
Display: LCD, Liquid Crystal Display
Battery: 1.55V (LR41)
Battery Life: Estimated 4,500 measurements
Measurement Time: Oral 30* seconds / Rectal 25-35 seconds / Axillary 90 seconds
Measurement Range: 90.0°F to 109.9°F (32.0°C to 42.9°C)
96.0°F to 107.0°F ±0.2°F / 1°C (34.0°C to 42.0°C)
at a room temperature of 64.4°F to 82.4°F (18.0°C to 28.0°C)
Accuracy: 90.0°F to 96.0°F ±0.4°F / 0.2°C (32.0°C to 34.0°C)
and 107.0°F to 109.9°F (42.0°C to 42.9°C)
Measurement mode: Real measurement with peak-hold method
Audible Alarm: 1 beep at start-up. Continuous beep at measurement completion
Auto Turn-off n approximately 8 ±1 minutes
Memory: Last reading
Operating Conditions: 50°F to 104°F (10°C to 40°C)
Humidity of 15% to 95% (non-condensing)
Storage Conditions: -13°F to 131°F (-25°C to 55°C)
Humidity of 15% to 95% (non-condensing)
Standards: Complies with EN 12470-3, ASTM E 1112-00,
EC 60601-1, EC 60601-1- 2, EC 60601-1-11
Electromagnetic compatibility: device fulfills the stipulations
of standard EC 60601-1-2
The manufacturer recommends a calibration check every 2 years.
*30-second response time achieved in water bath test.
LIMITED WARRANTY
ADC warrants its products against defects in materials and workmanship under normal house-
hold use and service as follows:
1. Warranty service extends to the original retail purchaser only and commences with the date
of delivery.
2. Your Adtemp Digital Stick Thermometer is warranted for two years from date of purchase.
What Is Co ered: Replacement of parts, and labor.
What Is Not Co ered: Transportation charges to ADC. Batteries where supplied. Damages
caused by abuse, misuse, accident, or negligence, incidental, special, or consequential
damages. Some states do not allow the exclusion or limitation of incidental, special, or
consequential damages, so this limitation may not apply to you.
To Obtain Warranty Ser ice: Send item(s) postage paid to ADC, Attn: Repair Dept.,
55 Commerce Dr., Hauppauge, NY 11788. Please include your name and address, phone no., proof
of purchase, and a brief note explaining the problem.
Implied Warranty: Any implied warranty shall be limited in duration to the terms of this
warranty and in no case beyond the original selling price (except where prohibited by law).
This warranty gives you specific legal rights and you may have other rights which vary from state to state.
For Australian Consumers: Our goods come with guarantees that cannot be excluded under
the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and
compensation for any other reasonable foreseeable loss or damage. You are also entitled to
have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure
does not amount to a major failure.
IB p/n 93-413-00 rev 8 (7/20/21) Printed in China
LATEX
Microlife Corporation
9F, 431 RuiGuan Road
NeiHu, Taipei 114, Taiwan, R.O.C.
Medical Device Safety Service GmbH
(MDSS GmbH)
Schiff raben 41, 30175 Hannover, GERMANY
Mfg. by: ADC®
55 Commerce Drive, Hauppauge, NY 11788
Inspected in the SA
Made in China
Assembled in Vietnam
tel: 631-273-9600
toll free: 1-800-232-2670
fax: 631-273-9659
www.adctoday.com
email: info@adctoday.com
1639
EC REP

Other ADC Thermometer manuals

ADC Adtemp II 412 Maintenance manual

ADC

ADC Adtemp II 412 Maintenance manual

ADC Adtemp 423 User guide

ADC

ADC Adtemp 423 User guide

ADC Adtemp 427 Temple Touch Maintenance manual

ADC

ADC Adtemp 427 Temple Touch Maintenance manual

ADC Adtemp ULTRA 417 Maintenance manual

ADC

ADC Adtemp ULTRA 417 Maintenance manual

ADC Adimals 426 Manual

ADC

ADC Adimals 426 Manual

ADC Adtemp ULTRA 417 User manual

ADC

ADC Adtemp ULTRA 417 User manual

ADC ADTEMP 421 User manual

ADC

ADC ADTEMP 421 User manual

ADC Adtemp 424 Maintenance manual

ADC

ADC Adtemp 424 Maintenance manual

ADC Adimals 426 User manual

ADC

ADC Adimals 426 User manual

ADC Adtemp 433 User manual

ADC

ADC Adtemp 433 User manual

ADC Adtemp 422 Maintenance manual

ADC

ADC Adtemp 422 Maintenance manual

ADC Adtemp II 413 Maintenance manual

ADC

ADC Adtemp II 413 Maintenance manual

ADC Adtemp 429 User manual

ADC

ADC Adtemp 429 User manual

ADC Adtemp Temple Touch  427 User manual

ADC

ADC Adtemp Temple Touch 427 User manual

ADC Adtemp 422 Maintenance manual

ADC

ADC Adtemp 422 Maintenance manual

ADC Adtemp II 412 Maintenance manual

ADC

ADC Adtemp II 412 Maintenance manual

ADC Adtemp II 412 Maintenance manual

ADC

ADC Adtemp II 412 Maintenance manual

ADC Adtemp 418N User manual

ADC

ADC Adtemp 418N User manual

ADC Adtemp V 418 Owner's manual

ADC

ADC Adtemp V 418 Owner's manual

ADC Adtemp V 418 Maintenance manual

ADC

ADC Adtemp V 418 Maintenance manual

ADC Adtemp 413 User manual

ADC

ADC Adtemp 413 User manual

ADC Adimals 426 User manual

ADC

ADC Adimals 426 User manual

ADC Adtemp V 418N User manual

ADC

ADC Adtemp V 418N User manual

ADC Adtemp 415FL User manual

ADC

ADC Adtemp 415FL User manual

Popular Thermometer manuals by other brands

Little Doctor LD-300 instruction manual

Little Doctor

Little Doctor LD-300 instruction manual

VOLTCRAFT IR 500-8S SE operating instructions

VOLTCRAFT

VOLTCRAFT IR 500-8S SE operating instructions

GHM GREISINGER G 1700 Series Compact manual

GHM

GHM GREISINGER G 1700 Series Compact manual

Oakton Temp-16 instruction manual

Oakton

Oakton Temp-16 instruction manual

Welcare WDT606 (Ultimate) user manual

Welcare

Welcare WDT606 (Ultimate) user manual

Extech Instruments HD550 user guide

Extech Instruments

Extech Instruments HD550 user guide

RIDGID micro IR-200 Operator's manual

RIDGID

RIDGID micro IR-200 Operator's manual

Honeywell TE218ELW user manual

Honeywell

Honeywell TE218ELW user manual

Chauvin Arnoux C.A 861 user manual

Chauvin Arnoux

Chauvin Arnoux C.A 861 user manual

Radiant Innovation TH06F manual

Radiant Innovation

Radiant Innovation TH06F manual

VOLTCRAFT IR-SCAN-350RH/2 operating instructions

VOLTCRAFT

VOLTCRAFT IR-SCAN-350RH/2 operating instructions

Maverick Industries XR-40 instruction manual

Maverick Industries

Maverick Industries XR-40 instruction manual

Philips DL8740 manual

Philips

Philips DL8740 manual

ATP Electronics TH-986 user guide

ATP Electronics

ATP Electronics TH-986 user guide

BASETech 1065 operating instructions

BASETech

BASETech 1065 operating instructions

GUILCOR AR003825 user guide

GUILCOR

GUILCOR AR003825 user guide

ST VA6530A manual

ST

ST VA6530A manual

Chicco ThermoFamily Instructions for use

Chicco

Chicco ThermoFamily Instructions for use

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.