ADTRAN PRACTICES 5th Gen HTU-C/HTU-R Quick Start guide
HDSL DEPLOYMENT GUIDELINES
TheADTRANHDSLsystemisdesignedtoprovideDS1
based services over loops designed to comply with
CarrierServiceArea(CSA)guidelines. CSAdeployment
guidelines are given below.
1. All loops are non-loaded only.
2. For loops with 26-AWG cable, the maximum
looplengthincludingbridgedtaplengthsis9kft.
3. For loops with 24-AWG cable, the maximum
loop length including bridged tap lengths is
12kft.
4. Any single bridged tap is limited to 2kft.
5. Total bridged tap length is limited to 2.5kft.
6. Thetotal lenghtofmulti-gaugecable containing
26-AWG cable must not exceed:
12 -{(3*L26)/9} - LBTAP (in kft)
L26 = Total length of 26-AWG cable excluding
bridged taps (in kft)
LBTAP = Total length of all bridged taps (in kft)
This deployment criteria is summarized in the chart
shown.
Recommendedmaximumlocalloop lossinformationfor
PICcableat70°F,135Ω,resistiveterminationislistedin
the provided table.
An approximation for maximum amount of wideband
nosieonaDSLlocalloopasmeasuredbya50kbpsfilter
is < 31dBrn.
Anapproximationformaximumamountofimpulsenoise
onaDSLlocalloopasmeasuredbya50kbpsfilteris<50dBrn.
These approximations are to be used as
guidelinesonlyandmayvaryslightlyondifferent
loops. Adheringtotheguidelinesshouldproduce
performance in excess of 10
-7
BER.
0
12
11
10
9
8
7
6
5
4
3
2
1
01234
WORKING LENGTH OF 26 GAUGE CABLE (KFT)
WORKING LENGTH OF 24 GAUGE (OR COARSER) CABLE (KFT)
56789
2.5
INVALID HDSL CABLE LENGTHS
2.0 1.5 1.0 0.5 0.0
TOTAL
BRIDGED
TAPLENGTH
(KFT)
VALID HDSL CABLE LENGTHS
Loop Insertion Loss
)zH(ycneuqerF)Bd(ssoLmumixaM
0003
000,01
000,05
000,001
000,051
000,002
0.21
0.51
5.52
0.03
57.23
52.53
ADTRAN Technical Support (800) 726-8663
Standard support hours, Monday-Friday, 7am-7pm CST
Emergency Support 7 days/week, 24 hours/day
When deployment requires the use of two HREs, the
HTU-CMcanbedeployedwithtwoLowVoltageT400
HREs (1244.041L2) and one Low Voltage HTU-R
(1245.021L1 or 1245.026L1).