C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
For more information, refer to the Installation and Maintenance Practice (P/N 61221002L1-5) available online at www.adtran.com.
©2006 ADTRAN, Inc.
All Rights Reserved.
HDSL2
H2TU-C
P/N: 1221002L1
CLEI: SLL6211D_ _
H2TU-C for Litespan®Using Narrowband/Wideband Pairs
H TUC
DSL
1221002L1 NB/WB
STAT
RLOS
HLOS
HCRC
ARM
LBK
B8ZS
AHDSL2
*61221002L1-22D*
INSTALLATION
After unpacking the unit, inspect it for damage. If damage is noted, file a claim with
the carrier and then contact ADTRAN. Refer to Warranty.
To install the H2TU-C for Litespan, perform the following steps:
1. If present, remove the Access Module Blank from the appropriate access module
slot of the chassis.
2. Pull the ejector latch, located on the lower right-hand side of the H2TU-C for
Litespan front panel, from its closed position.
3. Hold the H2TU-C for Litespan by the front panel while supporting the bottom
edge of the module with the ejector latch opened to engage the chassis edge.
Align the module edges to fit in the lower and upper guide grooves for the access
module slot.
4. Slide the module into the access module slot. Simultaneous thumb pressure at the
top and at the bottom of the module ensures that the module is firmly positioned
against the backplane of the chassis. Secure the module in place by pushing up
and in on the ejector latch.
When installed, the H2TU-C for Litespan runs a series of self-tests. Once the self-
tests are complete, the status LEDs reflect the true state of the hardware.
TROUBLESHOOTING GUIDE
Compliance
Condition Solution
At power up, all
front panel
indicators are
off
1. Verify that the channel bank or ONU BPS power LEDs are on.
2. Make sure that unit is fully and correctly inserted into the channel bank or ONU.
3. If step 1 fails, contact Alcatel customer service (800-848-0333). If step 1 passes,
but step 2 fails, replace the H2TU-C.
The STAT LED
remains Red.
1. Verify that the channel bank or ONU BPS power LEDs are on.
2. Verify that the equipment type for the Litespan H2TU-C slot is AHDSL2. Using
TL1, equipment type is shown with the command rtrv-eqpt::AID, where AID is
the access identifier (i.e., cot-1-15).
3. If step 1 fails, contact Alcatel customer service. If step 1 and step 2 pass, replace
the H2TU-C. If step 1 passes but step 2 fails, delete the equipment record (i.e., dlt-
eqpt::cot-1-15 with TL1) and reinsert the card, or equip the slot with the currently
reserved equipment type.
The STAT LED
is off, but the
HLOS LED
remains Red
1. Confirm that the HDSL2 loop is not open.
2. Confirm that the HDSL2 loop is not shorted.
3. Verify the loop conforms to CSA guidelines and is not too long. Loop loss at 196
kHz should be less than 35 dB.
4. Verify that the HDSL2 loop has acceptable noise limits.
5. Verify that tip and ring of each HDSL2 loop belongs to the same twisted pair.
6. If steps 1 through 5 pass, but the HLOS LED remains red, replace the H2TU-C.
7. If step 6 fails, replace the H2TU-R.
The STAT LED
is off, but the
RLOS LED
remains Red.
1. Check that framing line coding are set appropriately for T1 data at the H2TU-R.
2. Check that the RLOS LED at the H2TU-R is off.
3. If step 1 fails, change the appropriate framing and line coding. If step 1 passes, but
step 2 fails, a problem may exist at the H2TU-R T1 interface. If the problem does
not exist at the T1 interface, replace the H2TU-C.
Code Input Output
Power Code (PC) F C
Telecommunication Code (TC) – X
Installation Code (IC) A –
FRONT PANEL LED INDICATORS
DSL zGreen............... HDSL2 SNR quality is optimum (6 dB or higher)
zYellow ............. HDSL2 SNR quality is marginal (1-5 dB)
zRed .................. HDSL2 SNR quality is poor (0 dB)
2Flashing .......... HDSL2 Pulse Attenuation is >30 dB
STAT {Off ................... Indicates loss of power to the H2TU-R
zGreen............... Normal operation; HDSL2 synchronized with H2TU-R
2Flashing Green Acquiring HDSL2 synchronization with H2TU-R
zRed .................. Failure indication; unable to start/load firmware
RLOS {Off ................... DS1 signal from CPE is present at H2TU-R
zRed ................... DS1 signal from CPE is absent at H2TU-R or framing
does not match
HLOS {Off ................... HDSL2 synchronization achieved
zRed .................. HDSL2 loss of synchronization
2Flashing Red ... DC continuity fault detected on HDSL2 loop
HCRC {Off ................... No HDSL2 CRC errors within last 30 minutes
zYellow ............. Four or more HDSL2 CRC errors in last 30 minutes
zRed .................. HDSL2 CRC errors are being detected
ARM/LBK{Off ................... No loopback active
zGreen............... Loopback is active on this module
zYellow ............. Module is armed but loopback is not active
B8ZS {Off ................... AMI line code
zGreen............... B8ZS line code
CARD EDGE PINOUT
ADTRAN®uses negative ground-referenced span powering voltage (–190 VDC) on
the HDSL2 loop. H2TU-R span powering can be disabled to allow locally powered
H2TU-R applications, if desired.
H2TU-C for Litespan plugs directly into a Litespan channel bank assembly channel
unit slot. Litespan system software must be version 11.0.0 or higher. The tip and ring
connections from the H2TU-C to the shelf are made through card edge pins:
NOTE: If the Litespan AHDSL2 is used in applications where narrowband and
wideband copper service wire pairs are connected simultaneously, only one
service pair can have terminating equipment connected to the H2TU-C.
Also, copper service wire pairs not in use are considered as bridge taps to
the HDSL2 loop in service and should be entered into the deployment
calculations listed in Section 4 of this practice. If the bridged taps presented
by the unused loop violates the CSA guidelines, the unused pair should be
disconnected.
CAUTION: Do not deploy a Litespan AHDSL2 into any Litespan Channel Bank
Assembly slot that has ADSL Power Distribution Fuse and Alarm
(PDFA) connections to Wideband pairs of the Channel Bank Assembly.
Litespan is a Registered trademark of Alcatel, Inc., Paris, France.
♦Narrowband Tip - Pin A3
♦Narrowband Ring - Pin A4
♦Wideband Tip - Pin C7
♦Wideband Ring - Pin C8
61221002L1-22D
0607
PRICING AND AVAILABILITY 800.827.0807
TECH SUPPORT 800.726.8663
RETURN FOR REPAIR 256.963.8722
www.adtran.com
61221002L1-22D
Warranty: ADTRAN will replace or repair this product within the warranty period if it does not meet its published specifications or fails while in service.
Warranty information can be found online at www.adtran.com/warranty.
H2TU-C for Litespan Using Narrowband/Wideband Pairs
PROVISIONING OPTIONS / LOOPBACK FUNCTIONS
Upon initial insertion of the Litespan H2TU-C into the Litespan system, the H2TU-C is provisioned
with the configuration data stored in the shelf controller. The H2TU-C should be pre-provisioned as
indicated under “Pre-Configuration Value” in the table below. The loopback function codes are shown
at right.
H2TU-C
Options
Corresponding
Litespan Parameter
H2TU-C
Available Setting
Corresponding
Litespan Setting
Pre-Configurable
Value
Line Code LINECDE AMI
B8ZS
AMI
B8ZS
B8ZS
Framing 1FMT SF
ESF
Unframed
Auto
SF
ESF
UNFR
AUTO
AUTO
NIU Loopback NIDLPBK Disabled
Enabled
NO
YES
YES
Loopback
Timeout 1
LBKTMO 0
20 Minutes
60 Minutes
120 Minutes
0
20
60
120
120
DS1 TX Level AT 0
–7.5 dB
–15 dB
0.0
–7.5
–15
0.0
New England
Loopback 1,2
LPBKACTR Disabled
Enabled
0000000000000000
0000000000000001
0000000000000000
Latching
Loopback
FT1MODE T1
FT1
NO
YES
NO
Span Power LP Disabled
Enabled
SINK
SOURCE
SOURCE
Customer Loss
Indicator 3
LPBKDEACTCDE AIS
AIS/CI
Loopback
0000000000000000
0000000000000001
0000000000000010
0000000000000001
PRM Setting LPBKACTC None
SPRM
NPRM
Auto (Both)
0000000000000000
0000000000000001
0000000000000010
0000000000000011
0000000000000001
Network Keep
Alive
NTWKKPALV Disabled
Enabled
NO
YES
NO
1. Some settings may not be available at the H2TU-R.
2. This option is only available if the H2TU-R P/N 1221026L1, 1222026L1, 1223026L1 is used in the circuit.
3. This option is not available if the H2TU-R P/N 1221026L1, 1222026L1, 1223026L1 is used in the circuit.
Function/Code Response
1 in 3 (1) (100) Loop down everything
1 in 6 (100000) (1) If armed, Loops back at the H2TU-R toward the network.
4 in 7 (1111000) Loops back data from network toward network in the H2TU-C
6 in 7 (1111110) Loops back data from customer toward customer in H2TU-C
1111 1111 0001 1110 Loops back data from network toward network at H2TU-C (FF1E HEX)
0011 1111 0001 1110 Loopback data from customer toward customer at H2TU-C (3F1E HEX)
Arm/ 11000 (known as
2-in-5 pattern) (1)
Loops the H2TU-R toward the network and arms the H2TU-C. No AIS or errors are sent. When
sent from the customer, this code arms all modules.
Arm/ FF48 (1)
(1111 1111 0100 1000)
This pattern is sent on ESF FDL. When sent from network, all modules are armed and the
H2TU-R is looped back toward network. This code has no functionality when sent from the
customer.
Disarm/ 11100 (1) (known
as 3-in-5 pattern)
All modules are removed from the armed state and looped down when the 11100 pattern is
received. The LBK LEDs turn off on all modules.
Disarm/ FF24 (1)
(1111 1111 0010 0100)
This pattern is sent on ESF facility data link, and disarms and/or loops down all modules.
H2TU-C Network Loop up
/ D3D3 (1, 2)
(1101 0011 1101 0011)
If the modules have been armed and no modules are in loopback (5), the H2TU-C loops up
toward the network, 2 seconds of AIS (all 1s) are sent, 5 seconds of data pass, and then 231 bit
errors are injected into the DSX-1 signal. As long as the pattern continues to be sent, 231
errors are injected every 20 seconds. When the pattern is removed, the module remains in
loopback. If the pattern is reinstated, the injection of 231 bit errors resumes at 20-second
intervals.
H2TU-R Address 20 for
extended demarc / C754
(1)
(1100 0111 0101 0100)
When sent from the network, an H2TU-R network loopback is activated and a 200-bit error
confirmation is sent. 2 seconds of AIS (all 1s) is sent, 5 seconds of data pass, and then 200 bit
errors are injected into the DSX-1 signal. As long as the pattern continues to be sent, 200
errors are injected every 20 seconds. The HDSL2 office unit does not block transmission of far-
end NIU loopback from the customer premise (H2TU-R).
Loop down / 9393 (1, 3)
(1001 0011 1001 0011)
All modules currently in loopback loop down, but remain in the armed state.
Query Loopback / D5D5
(1, 2)
(1101 0101 1101 0101)
If the modules are armed and the H2TU-C or H2TU-R are in network loopback, errors are
injected into the DSX-1 signal upon detection of the query loopback pattern. As long as the
pattern continues to be sent, errors are injected again every 20 seconds. The number of errors
injected each time depends on which unit is in loopback. 231 errors are injected if the H2TU-C
is in network loopback and 20 at a time if the H2TU-R is in network loopback.
Query Loop Parameters/
DBDB (2)
(1101 1011 1101 1011)
If the units are armed and the H2TU-C is in network loopback, errors are injected into the
DSX-1 signal upon detection of the query loop parameters pattern. As long as a pattern contin-
ues to be sent, errors are injected again every 20 seconds. The number of errors injected each
time depends on the current status of signal quality and pulse attenuation parameters on each
loop.
111 errors are injected if all HDSL2 receiver points (H2TU-C, and H2TU-R) indicate pulse
attenuation is 30 dB or lower and signal quality (margin) is 6 dB or higher.
11 errors at a time are injected if any of the receiver points indicate pulse attenuation is greater
than 30 dB and/or signal quality (margin) is less than 6 dB.
Loopback Time Out Over-
ride / D5D6 (1, 2, 4)
(1101 0101 1101 0110)
If the units are armed and this pattern is sent, the loopback time out is disabled. The time out
option is updated to NONE on the PROVISIONING menu of the H2TU-R screens (viewable
through the RS-232 port). As long as the units remain armed, the time out remains disabled.
When the units are disarmed, the loopback time out returns to the value it had before the
D5D6 code was sent.
Span Power Disable /
6767 (1, 2, 4)
(0110 0111 0110 0111)
If the units are armed and this pattern is sent, the H2TU-C deactivate the span power supply,
removing power to the H2TU-R. As long as the pattern continues to be sent, the span power
supply remains disabled. When the pattern is discontinued, the H2TU-C reactivates its span
power supply, returning power to the remote unit. All units retrain and return to the disarmed
and unlooped state.
Note: All codes listed above must be sent for a minimum of 5 seconds in order for them to be detected and acted upon.
1. The H2TU-C and H2TU-R individually detect and act upon in-band loopback control codes. Depending on which list
number of H2TU-R is used with the Litespan H2TU-C, some of these control codes may not cause action (such as loop
up, error injection, etc.) at the H2TU-R. Refer to the H2TU-R documentation for supported control codes.
2. Modules must be armed with 11000b or FF48h for this code to function.
3. In order to behave like a NIU, the H2TU-R can not loop down from the network side with 9393h.
4. This code can be detected only if the modules are armed OR if any loopbacks are active.
5. If NIU is enabled, then the H2TU-R can be in network loopback when the H2TU-C or H2R loop up codes are sent.

This manual suits for next models

2

Other ADTRAN Transceiver manuals

ADTRAN 3192 HTU-C Instruction Manual

ADTRAN

ADTRAN 3192 HTU-C Instruction Manual

ADTRAN 3192 H4TU-C Instruction Manual

ADTRAN

ADTRAN 3192 H4TU-C Instruction Manual

ADTRAN HTU-C M Instruction Manual

ADTRAN

ADTRAN HTU-C M Instruction Manual

ADTRAN T200 H2TU-R Instruction Manual

ADTRAN

ADTRAN T200 H2TU-R Instruction Manual

ADTRAN HTU-C M R Instruction Manual

ADTRAN

ADTRAN HTU-C M R Instruction Manual

ADTRAN HDSL DDM+ HTU-C Instruction Manual

ADTRAN

ADTRAN HDSL DDM+ HTU-C Instruction Manual

ADTRAN HDSL4 T200 H4TU-R Instruction Manual

ADTRAN

ADTRAN HDSL4 T200 H4TU-R Instruction Manual

ADTRAN 1442530G1 User manual

ADTRAN

ADTRAN 1442530G1 User manual

ADTRAN 3192 HDSL4 Instruction Manual

ADTRAN

ADTRAN 3192 HDSL4 Instruction Manual

ADTRAN jobAid+ 1700486F1 User manual

ADTRAN

ADTRAN jobAid+ 1700486F1 User manual

ADTRAN SFP+ 10 Gig XGS-PON N2 OLT User manual

ADTRAN

ADTRAN SFP+ 10 Gig XGS-PON N2 OLT User manual

ADTRAN Total Access 3000 User manual

ADTRAN

ADTRAN Total Access 3000 User manual

ADTRAN 3060 Instruction Manual

ADTRAN

ADTRAN 3060 Instruction Manual

ADTRAN 1700485F1 User manual

ADTRAN

ADTRAN 1700485F1 User manual

ADTRAN 1442482F7 User manual

ADTRAN

ADTRAN 1442482F7 User manual

ADTRAN 3192 H2TU-C Instruction Manual

ADTRAN

ADTRAN 3192 H2TU-C Instruction Manual

ADTRAN T200 FNID Instruction Manual

ADTRAN

ADTRAN T200 FNID Instruction Manual

ADTRAN T200 H2TU-R User manual

ADTRAN

ADTRAN T200 H2TU-R User manual

ADTRAN 3192 User manual

ADTRAN

ADTRAN 3192 User manual

ADTRAN HDSL4 T200 H4TU-R Instruction Manual

ADTRAN

ADTRAN HDSL4 T200 H4TU-R Instruction Manual

ADTRAN SFP+ 10 Gig XGS-PON N2 OLT User manual

ADTRAN

ADTRAN SFP+ 10 Gig XGS-PON N2 OLT User manual

ADTRAN 40 G ER4 QSFP+ User manual

ADTRAN

ADTRAN 40 G ER4 QSFP+ User manual

ADTRAN 11.3G XFP User manual

ADTRAN

ADTRAN 11.3G XFP User manual

ADTRAN jobAid+ PR30 10G PON User manual

ADTRAN

ADTRAN jobAid+ PR30 10G PON User manual

Popular Transceiver manuals by other brands

Vertex FT-817 Technical supplement

Vertex

Vertex FT-817 Technical supplement

Terasic NET-FMC user manual

Terasic

Terasic NET-FMC user manual

Kenwood TK-7160 Service manual

Kenwood

Kenwood TK-7160 Service manual

Icom IC-M423 instruction manual

Icom

Icom IC-M423 instruction manual

Yaesu FT-780R instruction manual

Yaesu

Yaesu FT-780R instruction manual

Midland ALAN 48 PLUS MULTI B Instruction guide

Midland

Midland ALAN 48 PLUS MULTI B Instruction guide

Micrel KSZ9031RNX user guide

Micrel

Micrel KSZ9031RNX user guide

Xilinx Spartan-6 FPGA Series user guide

Xilinx

Xilinx Spartan-6 FPGA Series user guide

Kenwood TS-770 operating manual

Kenwood

Kenwood TS-770 operating manual

MFJ Enterprises MFJ-9402 instruction manual

MFJ Enterprises

MFJ Enterprises MFJ-9402 instruction manual

Technisonic Industries Limited TFM-30 Operator's guide

Technisonic Industries Limited

Technisonic Industries Limited TFM-30 Operator's guide

Standard Communications GME Electrophone TX800 instruction manual

Standard Communications

Standard Communications GME Electrophone TX800 instruction manual

Toshiba NetPac Installation and operation manual

Toshiba

Toshiba NetPac Installation and operation manual

Kenwood TK-2200 instruction manual

Kenwood

Kenwood TK-2200 instruction manual

Hitron NOVA-2000 quick start guide

Hitron

Hitron NOVA-2000 quick start guide

Alinco DR-M03 instruction manual

Alinco

Alinco DR-M03 instruction manual

Alinco DJ-G1T manual

Alinco

Alinco DJ-G1T manual

Super Star 2000 Operation manual

Super Star

Super Star 2000 Operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.