Coin 1 Value dEn1
This option allows the owner to set a specific numerical value for
a coin entered. For example, in the United States the coin value
for one quarter would be measured in cents (25). Therefore, the
coin value entered for one quarter would be 00025.
If the Vend Price is set for “.75”, and the Coin Value is set for
“00025”, the vend price displayed will decrease by 0.25 for each
coin entered and 3 coins will need to be entered to satisfy the
vend price.
1. Control must be in Manual Mode. Refer to How to Enter the
Manual Mode.
2. Press the NORMAL WARM (∧) or the DELICATES COLD
(∨) keypad until Prog appears in the display. Press the
START (enter) keypad, and AtS will appear in the display.
3. Press the NORMAL WARM (∧) or the DELICATES COLD
(∨) keypad to scroll through the programmable options until
dEn1 appears in the display.
4. When dEn1 appears in the display, press the START (enter)
keypad. There are five digits in the Coin 1 Value. The fifth
digit will appear in the display and will flash one second on,
one second off.
5. Press the NORMAL WARM (∧) or the DELICATES COLD
(∨) keypad to increase or decrease the value of the fifth digit.
NOTE: The coin value can be set from 1 to 65,535.
The factory default setting is 25.
6. Press the START (enter) keypad to enter the fifth digit and
display remaining four digits. The active digit will flash one
second on and one second off.
NOTE: To go back to the current programmable op-
tion without changing the value, press the PERM
PRESS WARM (<) keypad.
7. Press the NORMAL WARM (∧) or the DELICATES COLD
(∨) keypad to increase or decrease the value of the active digit
and the START (enter) keypad to enter the value of the digit
and advance to the next digit.
8. Press the START (enter) keypad when the correct value ap-
pears in the display. The new value is saved and the next op-
tion will appear in the display.
Coin 2 Value dEn2
This option allows the owner to set a specific numerical value for
a coin entered when using a dual coin drop. For example, the coin
value for a dollar coin would be measured in cents (1.00). There-
fore, the coin value entered for one dollar coin would be 00100.
If the Vend Price is set for “2.00”, and the Coin Value is set for
“00100”, the vend price displayed will decrease by 1.00 for each
dollar coin entered.
1. Control must be in Manual Mode. Refer to How to Enter the
Manual Mode.
2. Press the NORMAL WARM (∧) or the DELICATES COLD
(∨) keypad until Prog appears in the display. Press the
START (enter) keypad, and AtS will appear in the display.
3. Press the NORMAL WARM (∧) or the DELICATES COLD
(∨) keypad to scroll through the programmable options until
dEn2 appears in the display.
4. When dEn2 appears in the display, press the START (enter)
keypad. There are five digits in the Coin 2 Value. The fifth
digit will appear in the display and will flash one second on,
one second off.
5. Press the NORMAL WARM (∧) or the DELICATES COLD
(∨) keypad to increase or decrease the value of the fifth digit.
NOTE: The coin value can be set from 1 to 65,535.
The factory default setting is 100.
6. Press the START (enter) keypad to enter the fifth digit and
display remaining four digits. The active digit will flash one
second on and one second off.
NOTE: To go back to the current programmable op-
tion without changing the value, press the PERM
PRESS WARM (<) keypad.
7. Press the NORMAL WARM (∧) or the DELICATES COLD
(∨) keypad to increase or decrease the value of the active digit
and the START (enter) keypad to enter the value of the digit
and advance to the next digit.
8. Press the START (enter) keypad when the correct value ap-
pears in the display. The new value is saved and the next op-
tion will appear in the display.
Start Pulse Value PLSE
This option allows the owner to program the value of the Start
Pulse if used for multiple pulses with an after-market central card
reader or pay system.
1. Control must be in Manual Mode. Refer to How to Enter the
Manual Mode.
2. Press the NORMAL WARM (∧) or the DELICATES COLD
(∨) keypad until Prog appears in the display. Press the
START (enter) keypad, and AtS will appear in the display.
3. Press the NORMAL WARM (∧) or the DELICATES COLD
(∨) keypad to scroll through the programmable options until
PLSE appears in the display.
4. When PLSE appears in the display, press the START (enter)
keypad. There are five digits in the Start Pulse Value. The
fifth digit will appear in the display and will flash one second
on, one second off.
5. Press the NORMAL WARM (∧) or the DELICATES COLD
(∨) keypad to increase or decrease the value of the fifth digit.
NOTE: The Start Pulse Value can be set from 1 to
65,535. The factory default setting is 25.
6. Press the START (enter) keypad to enter the fifth digit and
display remaining four digits. The active digit will flash one
second on and one second off.
Programming Control
© Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
17 Part No. 203677ENR3