EDC Installation and Maintenance Instructions
10-7821 Terminal Descriptions (cont.)
BOARD NAME DESCRIPTION EXPLANATION
J7
OPN
Open
Passage
Connection for placing turnstile in
“OPEN” status - CW Direction
Providing a continuous dry-contact signal at this terminal places the
turnstile in an “OPEN” mode. Typically, this terminal is used to connect
the re alarm system (normally open type) when the turnstile is
congured for clockwise rotation in the exit direction (default).
J7 CNT
Passage
Count
Conrmation signal upon turnstile
rotation - CW Direction
Outputs a dry-contact signal upon rotation of the turnstile. This feature
can be used to output a “count” signal to an external system such as
Alvarado’s GateWatch or to provide feedback to the access control
system that a turnstile rotation has taken place.
J7 COM
Passage
Count
Conrmation signal upon turnstile
rotation - CW Direction
Common dry-contact signal for CNT count signal output. See J3 CNT
description.
SW6 CW Entry
Activation
Test Button
Allows user to test turnstile activation -
CW Direction
Depressing button simulates input to J7 ACC, “Entry Accept”. If
turnstile solenoid “res” after depressing button AND re-locks after a
single rotation of the arms or upon time out, the turnstile is functioning
correctly in the clockwise direction.
J2
CCW-CNT Output of contact closure upon turnstile
rotation – CCW Direction
Single throw, relay output for connection to Alvarado battery-powered,
digital counter.
J8
CW-CNT Output of contact closure upon turnstile
rotation - CW Direction
Single throw, relay output for connection to Alvarado battery-powered,
digital counter.
J5
Optical
Sensors
Connection for sensors The turnstile control board uses input from the sensors to monitor
rotation of the arms.
J11
CNT-
RESET
Connection for counter-reset key switch Normally-open dry-contact connection if counter wires are attached
to J2 and/or J8 connections. A 2-position electrical key switch is
connected here to provide a reset to the individual counters.
SW3
Reset
counters
Local-Battery Counter-Reset Switch If counter wires are attached to the board (J2 and J8), depressing this
button will reset the counters. If two counters are installed and wired,
both counters will be reset.
J19
Connection for EL function light board If red/green status lights are used, the green light signies that the
turnstile is ready to accept an activation for the direction shown.
When the CLS and GND connection is closed, the red light will be
illuminated and signies that the turnstile will not accept an activation.
Refer to description for CLS on J3 and J7.
J4
Power
Input
Connection for low voltage power The turnstile control board will accept 10 VAC or 13.5 VDC power.
If primary power is not run to the turnstile, low-voltage power is
connected here and the green ground wire must be grounded to the
chassis.
Sets solenoid control for the clockwise direction in fail lock
conguration. Power is applied to solenoid upon activation
signal to release lock arm for rotation.
CWFL
FS Sets solenoid control for the clockwise direction in fail
safe conguration. Power is applied to solenoid for locked
condition and removed upon activation signal to release lock
arm for rotation.
Sets solenoid control for the counterclockwise direction in
fail lock conguration. Power is applied to solenoid upon
activation signal to release lock arm for rotation.
CCWFL FS Sets solenoid control for the counterclockwise direction
in fail-safe conguration. Power is applied to solenoid for
locked condition and removed upon activation signal to
release lock arm for rotation.
Adjusts automatic turnstile relock. See Figure 7 for
settings.
T3 T3ON Adjusts automatic turnstile relock. See [Figure 7] for
settings.
Adjusts automatic turnstile relock. See Figure 7 for
settings.
T4 T4ON Adjusts automatic turnstile relock. See [Figure 7] for
settings.
Sets Length of time of contact closure on CNT and COM
feedback to 100ms.
100 FBPL Sets Length of time of contact closure on CNT and COM
feedback to 300ms.
Set switch to left when using Red/Yellow/Green activation
lights.
JS3 JS2 Set switch to right when using Red/Green activation lights.
Sets operation to standard optical sensor conguration for
passage feedback after second sensor detection.
STD ROFP Sets operation to custom optical sensor conguration for
passage feedback on rst sensor detection.
Congures OPN terminals as normally open (N.O.).
OPN inputs are used for re alarm / free passage modes.
AUX AUX
Congures OPN terminals as normally closed (N.C.).
OPN inputs are used for re alarm / free passage modes.
SW4 Layout
LEFT / OFF Switch
Position
Switch
Position RIGHT / ON