17"
24¼"
Electrical outlet must
be located within 5-feet
of this point.
DimensionsofFinishedOpening
Masonry Construction
Inmasonry walls, cut or build a finished opening 17-inches
high by 24¼-inches wide. Secure outer case in wall with
mortaror concrete nails driven throughholes in sides of
outercase(predrill holes in case before securing).
Brick Veneer or Frame Wall Construction.
Cutorbuildroughopening large enough to allow a framed,
finishedopening17-incheshighand24¼-incheswide.
Secure outer case to framing material with nails or screws
driventhrough holes in sides ofouter case (predrill holes in
casebeforesecuring).
Framing
lumber
24¼"
17"
Framed/FinishedOpening
(brickveneerorframewallconstruction)
Placement of Outer Case in Opening
Center outer case in finished opening. Front of case must
project¾-inch (minimum) beyond inside wall in order to
attachairconditionerfrontframe.
Ifframingindoorsideoffinishedopeningwithwoodmolding
(orotherdecorative material), outer case must extend
¾-inch(minimum) beyond molding in order to attach air
conditionerfrontframe.
PartNo.20070203 ©1998AmanaAppliances
Printedin USA Amana, IA 52204
Back of case (outdoor side) must be at least 3/8-inch lower
thanfrontofcaseto ensure proper condensate drainage.
Ensurecase has proper slope beforesecuring in place.
Caulk all
sides
Lintel and
flashing
(if required)
Outercase must project
a minimum ¾"
beyond inside wall
or molding to attach front frame
93/8"
Install case
with 3/8"
slope to outside
for condensate
drainage
Front of outer case
to side air louvers
Optional
molding
(not provided)
InstalledCase
(brickveneerorframewallconstructionshown)
Installation in Wall Thicker Than 93/8-inches
Thesidelouversinoutercaseprovideventilationtoair
conditionercompressor and fan motor andmust not be
blocked. When installing unit in a wall over 93/8-inches
thick, provisions must be made in wall opening to ensure
freeair flow to the side louvers. This can be accomplished
bychamferingthevertical portions of the outside opening
asshown.
Ventilation louvers on top of case must not be obstructed.
Do not attempt to install unit in walls thicker than
11¾-inches.
Front of
outercase
4" 4"
Side air
louvers
(both sides)
¾" minimum
projection
11¾"
93/8"
31¾"
23¾"
ChamferingWallsThickerThan93/8-inches
(topview)