−3−
■
How to connect
・Use clean air filtered through air dryer and air filter. ······ If not, dirty air can cause painting failure.
・If you use this spray gun for the first time after purchasing, clean fluid passages sprayingthinner and remove rust preventive oil.
If not, remaining rust preventive oil can cause painting failure such as fish eyes.
・Firmly fix hose or container to spray gun. ······ If not,disconnection of hose and drop of container can cause bodilyinjury.
Job1. Connectanair hose to air nippletightly.
Job2. Connect a fluid hose or a container to fluid nipple tightly.
Job3. Flush the spray gun fluid passage with a compatiblesolvent.
Job4. Pour paint into container, test spray and adjust fluid output as well as pattern width.
■
Maintenance and inspection
・First release air and pressure fully according to item No. 3 of “Improper useof equipment” ofWARNING on page 2.
・Only an experienced person who is fully conversant with the equipment can do maintenance and inspection.
・
pH value shall be 6 to 8, otherwise could cause corrosion.
・
Never use commercial or other
ANEST IWATA original spare
Step-by-step procedure
Pour remainingpainttoanother container. Clean fluid passages and
Spray a small amount of thinner into fluidpassages to clean them.
Incompletecleaning canresultinpoor spraypattern and contaminated paint.
It is especially important clean the gun fully and promptly after using two-component paint.
with brush soaked with thinner and wipe out with waste
cloth.
Soaking whole spray gun in solvent may cause spray gun malfunction.
cap assy itself for extended period may cause defective pattern.
When cleaning, never scratch each hole of air cap assy, fluid nozzle, and fluid needle
assy.Neverdamage the tip of fluid nozzleormust not put yourhandon it.
3. Before disassembly, fullycleanfluidpassages.
Removefluidnozzle,usingaringspanner,boxwrenchoroptionalaccessoryspanner(code
93538601)
3. Duringdisassembly,avoidscratchingthe needleseatingsurface.
Eitherfirstremovethefluid needleorholdthe trigger back whileremovingthefluidpipeset,
to protect the seating surface.
you want to adjust fluid needle packing set, first tighten it by hand while
remains inserted. Then tighten it further about 1/6 turn (60-degree) by spanner.
When you remove needle packing set,do not leave plastic piece of needle packing set in
the spray gun body.
If you tighten fluid needle packing set too much,
resulting in paint leakagefromtipoffluid nozzle. Try toadjustit carefully whilepulling trigger
and confirming movement of fluid needleassy.
If you tighten it too much, first fully loosen it and then tighten it again carefully.
5. To assemble the air valve, first assemble the airvalve, air valve spring, and fluid adj. guide
assy. together. Next, insert fluid needleinto fluid adj. guide assy., then fit it to spray gun body
and screw fluid adj. guide assy. in.
If youtrytofit airvalve springandairvalve tothespraygun body withoutthefluid needle,
the air valve may not be fitted correctly and the packing inside fluid adj. guide assy. can
be damaged.
6. Beforeassemblingtheairadj.assy.backontothegunbody,fullyturntheadjustmentknobs
counterclockwise to open. Once in the gun body the air adj. knob can be tightened.
6. If air adj. knob is not fully opened when tightening into gun body, the tip of it can contact and
damagetheseating surface.
7. When you assemble the needle spring on the fluid needle, the plastic tip should be on the
opposite sideas thefluid needletip.
7. If plastic tip is on the wrong side, it may not operate normally. Incorrect installation of the
needle spring may cause a heavy trigger pull.
8.Graspfollowing Apartongunheadspanner,then remove fluidnozzle.
8.Removing or installing the fluidnozzle without holding down the gun head may cause
damage to the airpipe set.
Parts replacement standard
1. Eachhole passage of aircap assy and fluid nozzle Replace if it is crushed or deformed.
2. Packing and Oring Replaceifit is deformed or worn out.
3. Leakage from seat section between fluid nozzle and fluid needleassy Replacethemifleakagedoes notstop afterfullycleaning fluidnozzle andfluidneedleassy.
Fluidneedle
Needlespringassy
Plastictip