
−
3
−
■
How to connect
・
Use clean airfiltered through air dryer and air filter.
If not, dirty air can cause painting failure.
・
If you use this spray gun for thefirst time after purchasing, clean fluid passages spraying thinner and remove rust preventive oil.
If not, remaining rust preventive oil can cause painting failure suchas fisheyes.
・
Firmly fix hose or container to spray gun.
If not, disconnection of hose and drop of container can cause bodily injury
.
Job1. Connect an air hose to airnipple tightly.
Job2. Connect a fluid hose or a container to fluid nipple tightly.
Job3. Flush the spray gun fluid passage with a compatible solvent.
Job4. Pour paint into container, test spray and adjust fluidoutput as well as pattern width.
■
Maintenance and inspection
・
First release air and pressure fully according to item No.3 of “Improper useof equipment” of WARNING on page 2.
・
Only an experienced person who is fully conversant with the equipment can do maintenance and inspection.
・
pH valueshallbe 6 to 8, otherwise could cause corrosion.
・
Never use commercial or other
ANEST IWATA original spare
Step-by-step procedure
Pour remaining paint to another container. Clean
Spray a small amount of thinner to clean fluid passages.
Incomplete cleaning can fail pattern shapeand uniform particles.
Especially clean fully and promptly two-component paint after use.
Clean each section withbrush
soaked with thinner and wipe out with waste cloth.
Soaking whole spray gun in solvent may cause spray gun malfunction.
cap assy itself for extended period may cause defective pattern.
When cleaning, never scratch each hole of air cap assy, fluid nozzle, and fluid needle
assy.
Never damage the tip of fluid nozzleor mustnotput your hand on it.
3. Before disassembly, fully clean fluidpassages.
Remove fluid nozzle, using a ring spanner, box wrench or optional accessory spanner
(code 93538601)
3. Duringdisassembly, do not scratch seatsection.
Either first remove the fluid needle or hold the trigger back while removing the fluid nozzle,
to protect the seating surface.
When you want to adjust fluid needle packing set, first tighten it by hand while
assy remains inserted. Then tighten it further about 1/6 turn (60-degree) by spanner.
When you remove needle packing set, do not leave plastic piece of needle packing set in
thespray gun body.
If you tighten fluid needle packing set too much,
resulting in paint leakage from tip of fluid nozzle. Try to adjust it carefully while pulling
trigger and confirming movement of fluid needleassy.
When you tighten it too much,first fully loosen it and then tighten it againcarefully.
5. To assemble the air valve, first assemble the air valve, air valvespring, and fluid adj. guide
assy. together. Next, insert fluid needle into fluid adj. guide assy., then fit it to spray gun
body and screwfluid adj. guide assy. in
5. If you try to fit air valve spring and air valve to spray gun body set without fluid needle
assy, air valve will not be fitted correctly and lop packing inside fluid adj. guide assy will
be damaged.
6. Before assembling the pattern adj.assy. or air adj.assy. back on to the gun body, fully turn
the adjustment knobs counterclockwise to open. Once in the gun body the pattern adj.
knob and air adj. knob can be tightened.
6. If pattern adj. knobor airadj.knobis notfully opened when tightening into gun body, the tip
of it can contact and damage the seating surface.
7. When you assemble the needle spring on the fluid needle, the plastic tip should be on the
opposite sideas the fluidneedletip.
7. If plastic tip is on the wrong side, it may not operate normally.Incorrect installation of the
needle spring may cause a heavy triggerpull.
Parts replacement standard
1. Each holepassage of air cap assyand fluidnozzle Replaceif it is crushed or deformed.
2. Packing and O ring Replaceif it is deformed or worn out.
3. Leakage fromseat section between fluid nozzle and fluid needleassy Replacethem if leakage does not stop after fully cleaning the fluid nozzle and needle.
If you replace the fluid nozzle or fluid needle only, ensure they fully match and confirm that
thereisnoleakage.
Fluid (Gravity)
Fluidnipple
(Suction /Pressure)
Air
Fluidneedle
Needlespringassy
Plastictip