Instruction manual –AQ F3x0 Feeder protection IED 4 (162)
TABLE OF CONTENTS
1ABBREVIATIONS ............................................................................................................. 7
2GENERAL......................................................................................................................... 8
3SOFTWARE SETUP OF THE IED .................................................................................... 9
3.1 Measurements ..................................................................................................... 10
3.1.1 Current measurements and scaling ............................................................ 10
3.1.2 Voltage measurements and scaling ............................................................ 13
3.1.3 Line measurement ...................................................................................... 17
3.2 Protection functions ............................................................................................. 24
3.2.1 Three-phase instantaneous overcurrent I>>> (50) ...................................... 24
3.2.2 Residual instantaneous overcurrent I0>>> (50N)........................................ 26
3.2.3 Three-phase time overcurrent I>, I>> (50/51).............................................. 29
3.2.4 Residual time overcurrent I0>, I0>> (51N) .................................................. 46
3.2.5 Three-phase directional overcurrent IDir>, IDir>> (67) ................................ 49
3.2.6 Residual directional overcurrent I0Dir >, I0Dir>> (67N)............................... 52
3.2.7 Current unbalance (60) ............................................................................... 56
3.2.8 Thermal overload T>, (49L) ........................................................................ 58
3.2.9 Over voltage U>, U>> (59).......................................................................... 60
3.2.10 Under voltage U<, U<< (27)........................................................................ 61
3.2.11 Residual over voltage U0>, U0>> (59N) ..................................................... 62
3.2.12 Over frequency f>, f>>, f>>>, f>>>> (81O).................................................. 63
3.2.13 Under frequency f<, f<<, f<<<, f<<<< (81L)................................................. 64
3.2.14 Rate of change of frequency df/dt>, df/dt>>, df/dt>>>, df/dt>>>> (81R) ...... 65
3.2.15 Breaker failure protection function CBFP, (50BF) ....................................... 66
3.2.16 Inrush current detection (INR2), (68)........................................................... 68
3.2.17 Distance protection Z< (21) (Option)........................................................... 69
3.3 Control and monitoring functions.......................................................................... 90
3.3.1 Common-function block .............................................................................. 90
3.3.2 Trip logic (94).............................................................................................. 93
3.3.3 Dead line detection ..................................................................................... 96
3.3.4 Voltage transformer supervision (VTS) ....................................................... 98
3.3.5 Current transformer supervision (CTS) ..................................................... 102
3.3.6 Synchrocheck function du/df (25).............................................................. 103
3.3.7 Autoreclosing (79)..................................................................................... 112
3.3.8 Switch on to fault logic .............................................................................. 118
3.3.9 Voltage sag and swell (Voltage variation) ................................................. 121