Securitron®EEB2, EEB3N
Exit Button with Integrated Timer
Installation & Operating Instructions
Description
Model Securitron EEB2 is a two-inch square, exit button,
mounted on a stainless steel, single gang key plate.
Model Securitron EEB3N is a rectangular exit button,
mounted on a 1 3/4" stainless steel narrow stile key plate.
Both Securitron EEB2 and EEB3N have a 3A switching
capacity and a timer set for 30 seconds. These units are
intended only for release of a magnetic lock from the inside
of a door. When the button is pressed, the lock releases
for 30 seconds. If pressed again during the 30-second
lock release period, the unit will “retrigger” starting a
new 30-second lock release period. These buttons are
specifically intended for installation on access controlled
egress doors, as described in the International Building Code
(IBC). Check your jurisdiction for applicable IBC codes.
A motion detector, such as the Securitron Model XMS,
is the primary means of magnetic lock release on the
door. The Securitron EEB2 or EEB3N exit button is
employed as a backup means of releasing the lock in
case of a problem with the motion detector. It should
be noted that the exact release time will vary with
temperature, but it will not be less than 30 seconds.
UL294 Access Control
Performance Levels
The following are the UL294 access
control performance levels:
• Destructive Attack = Level 1
• Line Security = Level 1
• Endurance = Level 1 (6,000 cycles)
• Standby Power = Level 1
Securitron EEB2
Securitron EEB3N
2 of 4
Mounting
• MOUNT the Securitron EEB2 using
its included mounting device.
NOTE: The aluminum door frame must be sufficiently routed
out to accommodate the Securitron EEB3N components.
• MOUNT the Securitron EEB3N directly on
a narrow stile aluminum door frame.
Wiring
NOTES: The Securitron EEB2 and EEB3N operate on 12
VDC or 24 VDC, and can accept the use of full-wave
rectified DC (transformer and bridge rectifier).
Securitron EEB2 and EEB3N are factory shipped with the jumper in
place (12 VDC). If jumper is removed, unit operates on 24 VDC.
Securitron EEB2 and EEB3N draw no current when at rest, and only
draw 28 mA at 12 VDC or 38 mA at 24VDC when releasing the lock.
1. WIRE the Securitron EEB2 or EEB3N in
accordance with Diagram 1, 2 and 3.
CAUTION The Securitron EEB2
and EEB3N can be damaged if
operated on 24 VDC with the
jumper in place, or operated on a
power supply different than what
is operating the magnetic lock.
Red +12 V or + 24 V
0 V (DC Neg)
to LOCK “+” Wire
to + V
Black
Green
White
Secruitron
EEB2 or
EEB3N
Red
Green
Black
Black
Red
White Securitron
EEB2 or
EEB3N
Device
IN +
+
–
Magnalock
Securitron
XMS
Power
Supply
Diagram 1: Wire Identification
Diagram 2: Typical Connection
NOTE: Positive input voltage on the white wire must be from the
same power source that the red and black wires connected.
3 of 4
Changing the Alternate Lens
on the Securitron EEB2
1. GRASP and TURN OVER the keyplate.
2. From the back, ROTATE the white contact block of
the switch counterclockwise to the 11:00 o’clock
position, and PULL straight back to remove.
3. SLIDE a slender smooth-ended object, such as a marker
pen, inside the switch body up against the lens.
4. PLACE the object on a smooth surface with the
keyplate on top, and TAP the keyplate up and
down on the object to pop off the lens.
5. REMOVE the lens and insert.
6. TURN OVER the keyplate and PLACE a new
insert onto the front of switch.
7. ENSURE that the text on the insert is correctly reading to the
keyplate, and PLACE the matching color lens on top of insert.
8. PRESS around all edges of the lens until it snaps in place.
9. DEPRESS lens several times to ensure smooth
operation and the lens is not binding.
10. With the terminals upward, INSERT the contact block back
into the back of the switch at the 11:00 o’clock position and
ROTATE clockwise until it stops straight up and down.
To Lock
“+” Wire
To + V
+ 12 V or + 24 V
0 V
(DC Neg)
Diagram 3: Internal Schematic
NOTE: Positive input voltage on the white wire must be from the
same power source that the red and black wires are connected.
NC
C
C
NC
NO Trigger
+
–
Green
Alternate
Lens
White
Red
Black
Timer
Push
Button
4 of 4
Patent pending and/or patent www.assaabloydss.com/patents
Copyright © 2020, Hanchett Entry Systems, Inc., an ASSA
ABLOY Group company. All rights reserved. Reproduction in
whole or in part without the express written permission of
Hanchett Entry Systems, Inc. is prohibited. 500-12600_7
techsupport.esh@assaabloy.com | 800 626 7590
assaabloyesh.com
10027 S. 51st Street, Ste. 102 Phoenix, AZ 85044 USA
4 of 4
Changing the Alternate Lens
on the Securitron EEB3N
1. While holding keyplate, GRASP the top and bottom of
the lens and PULL straight out from the keyplate.
2. PLACE a new lens over the switch face, and ENSURE the
text on the lens is correctly reading to the keyplate.
3. PRESS completely until it snaps into place.
4. DEPRESS the lens several time to ensure smooth
operation and the lens is not binding.
Alternate
Lens
Warranty
For information on warranty coverage and replacement
options, please visit assaabloyesh.com/warranty

This manual suits for next models

1

Other Assa Abloy Safety Equipment manuals

Assa Abloy SARGENT 57 Series User manual

Assa Abloy

Assa Abloy SARGENT 57 Series User manual

Assa Abloy PDU8500 Series User manual

Assa Abloy

Assa Abloy PDU8500 Series User manual

Assa Abloy 179B User guide

Assa Abloy

Assa Abloy 179B User guide

Assa Abloy SARGENT 9400 Series User manual

Assa Abloy

Assa Abloy SARGENT 9400 Series User manual

Assa Abloy 179A User guide

Assa Abloy

Assa Abloy 179A User guide

Assa Abloy SARGENT Beacon User manual

Assa Abloy

Assa Abloy SARGENT Beacon User manual

Assa Abloy PDU8000 Series User manual

Assa Abloy

Assa Abloy PDU8000 Series User manual

Popular Safety Equipment manuals by other brands

Otto Bock HR2233-0000 K Instructions for use

Otto Bock

Otto Bock HR2233-0000 K Instructions for use

COURANT M-DROP manual

COURANT

COURANT M-DROP manual

Petzl B02 manual

Petzl

Petzl B02 manual

Ultra-safe M2-HPSY8Y User instruction manual

Ultra-safe

Ultra-safe M2-HPSY8Y User instruction manual

Nervures Fusion owner's guide

Nervures

Nervures Fusion owner's guide

Sabelt Seat belts user manual

Sabelt

Sabelt Seat belts user manual

SMART-SCAN ST Series installation guide

SMART-SCAN

SMART-SCAN ST Series installation guide

AirTech BSC-1304 II B2 instructions

AirTech

AirTech BSC-1304 II B2 instructions

BIRD TERMALINE 8745 Series Instruction book

BIRD

BIRD TERMALINE 8745 Series Instruction book

Promeba PS-182 user guide

Promeba

Promeba PS-182 user guide

Hunter Safety System HSS-320 Instruction and Safe Use Manual

Hunter Safety System

Hunter Safety System HSS-320 Instruction and Safe Use Manual

Petzl SUPERAVANTI TECHNICAL NOTICE

Petzl

Petzl SUPERAVANTI TECHNICAL NOTICE

Bircher Reglomat CareMat A01T E868 quick start guide

Bircher Reglomat

Bircher Reglomat CareMat A01T E868 quick start guide

Bornack ATTACK user manual

Bornack

Bornack ATTACK user manual

Plymovent PERSONALPRO User instructions

Plymovent

Plymovent PERSONALPRO User instructions

Spanset PowerForce Original operating instructions

Spanset

Spanset PowerForce Original operating instructions

PDS WorkSafe AZ 700 Series instruction manual

PDS

PDS WorkSafe AZ 700 Series instruction manual

Petzl METEORA quick start guide

Petzl

Petzl METEORA quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.