ATD Tools ATD-5570 User manual

ATD-5570
Deluxe Automotive Meter
with RPM and Temperature Functions
Owner’s Manual
Features:
t5FTUSBOHFT
t5FTUGVODUJPOT
t%JTQMBZTSQNGPS%*4BOETUBOEBSEJHOJUJPOT
t%VBMEJTQMBZXJUIBOBMPHCBSHSBQIBOEEJHJUBMSFBEJOHT
t#VJMUJOUFNQFSBUVSFSFBEJOHT
t*ODMVEFTSQNQJDLVQBOEUFNQFSBUVSFQSPCF
t.FH0INJOQVUJNQFEBODF
t%VBMGVTFQSPUFDUJPO
t4BGFUZMFBETBOEKBDLT
t#VJMUJOUJMUTUBOE
.BEFJO$IJOBUP"5%5PPMT*OD4QFDJöDBUJPOT
7JTJUVTBUXXXBUEUPPMTDPN ATD5570_rev_0817

Contents
4BGFUZ
(FUUJOH4UBSUFE
.FUFS#BTJDT
%JHJUBMBOE"OBMPH%JTQMBZ
'VODUJPOBOE3BOHF4FMFDU
1VTI#VUUPO'VODUJPOT
"MUFSOBUF'VODUJPO#VUUPO
3BOHF4FMFDU
3BOHF&YJU
%BUB)PME
Meter Functions
7PMUBHF
3FTJTUBODF
%JPEF$IFDL
"VEJCMF$POUJOVJUZ
"$PS%$$VSSFOU
5FNQFSBUVSF
'SFRVFODZ
%XFMM
%VUZ$ZDMF
31.
Maintenance
'VTFBOE#BUUFSZ3FQMBDFNFOU
5SPVCMF4IPPUJOH
(FOFSBM4QFDJöDBUJPOT
&MFDUSJDBM4QFDJöDBUJPOT
8BSSBOUZ*OGPSNBUJPO

Safety
DANGER
t&OHJOFTQSPEVDFDBSCPONPOPYJEFXIJDIJTPEPSMFTTDBVTFTTMPXFSSFBDUJPOUJNFBOEDBOMFBEUP
TFSJPVTJOKVSZ8IFOUIFFOHJOFJTPQFSBUJOHLFFQTFSWJDFBSFBT8&--7&/5*-"5&%PSBUUBDIUIFWFIJDMF
FYIBVTUTZTUFNUPUIFTIPQFYIBVTUSFNPWBMTZTUFN
t4FUUIFQBSLJOHCSBLFBOECMPDLUIFXIFFMTCFGPSFUFTUJOHPSSFQBJSJOHUIF
WFIJDMF*UJTFTQFDJBMMZJNQPSUBOUUPCMPDLUIFXIFFMTPOGSPOUXIFFMESJWF
WFIJDMFTUIFQBSLJOHCSBLFEPFTOPUIPMEUIFESJWFXIFFMT
t8FBSBOFZFTIJFMEXIFOUFTUJOHPSSFQBJSJOHWFIJDMFT
t&YDFFEJOHUIFMJNJUTPGUIJTNFUFSJTEBOHFSPVTMUXJMMFYQPTFZPVUPTFSJPVT
PSQPTTJCMZGBUBMJOKVSZ$BSFGVMMZSFBEBOEVOEFSTUBOEUIFDBVUJPOTBOEUIF
TQFDJöDBUJPOMJNJUTPGUIJTNFUFS
t7PMUBHFCFUXFFOBOZUFSNJOBMBOEHSPVOENVTUOPUFYDFFE7%$
PS7"$
t6TFDBVUJPOXIFONFBTVSJOHWPMUBHFBCPWF7%$PS7"$
t$JSDVJUUFTUFENVTUCFQSPUFDUFECZB"GVTFPSDJSDVJUCSFBLFS
t%POPUVTFUIFNFUFSJGJUIBTCFFOEBNBHFE
t%POPUVTFUIFUFTUMFBETJGUIFJOTVMBUJPOJTEBNBHFEPSJGNFUBMJTFYQPTFE
t"WPJEFMFDUSJDBMTIPDLEPOPUUPVDIUIFUFTUMFBETUJQTPSUIFDJSDVJU
CFJOHUFTUFE
t%POPUUSZBWPMUBHFNFBTVSFNFOUXJUIUIFUFTUMFBETJOUIF"PSUIF
N"UFSNJOBM
t8IFOUFTUJOHGPSUIFQSFTFODFPGWPMUBHFPSDVSSFOUNBLFTVSFUIFNFUFS
JTGVODUJPOJOHDPSSFDUMZ5BLFBSFBEJOHPGBLOPXOWPMUBHFPSDVSSFOUCFGPSF
BDDFQUJOHB[FSPSFBEJOH
t$IPPTFUIFQSPQFSSBOHFBOEGVODUJPOGPSUIFNFBTVSFNFOU%POPUUSZ
WPMUBHFPSDVSSFOUNFBTVSFNFOUTUIBUNBZFYDFFEUIFSBUJOHTNBSLFEPO
UIF'VODUJPO3BOHFTXJUDIPSUFSNJOBM
t8IFONFBTVSJOHDVSSFOUDPOOFDUUIFNFUFSJOTFSJFTXJUIUIFMPBE
t/FWFSDPOOFDUNPSFUIBOPOFTFUPGUFTUMFBETUPUIFNFUFS
t%JTDPOOFDUUIFMJWFUFTUMFBECFGPSFEJTDPOOFDUJOHUIFDPNNPOUFTUMFBE
t5IFN"BOEUIF"UFSNJOBMTBSFQSPUFDUFECZGVTFT5PBWPJEQPTTJCMFJOKVSZPSEBNBHFVTFPOMZJO
DJSDVJUTMJNJUFEUPN"PS"GPSTFDPOET

IMPORTANT
t5PNBJOUBJOBDDVSBDZPGUIFNFUFSSFQMBDFUIFEJTDIBSHFECBUUFSZJNNFEJBUFMZXIFOUIFCBUUFSZ
TZNCPMBQQFBSTPOUIFNFUFSEJTQMBZ
t"WPJENFBTVSJOHFSSPSGSPNPVUTJEFJOUFSGFSFODFLFFQUIFNFUFSBXBZGSPNTQBSLQMVHPSDPJMXJSFT
t"WPJEEBNBHJOHUIFNFUFSXIFOUFTUJOHWPMUBHFEJTDPOOFDUUIFUFTUMFBETGSPNUIFUFTUQPJOUTCFGPSF
DIBOHJOHGVODUJPOT
t%POPUFYDFFEUIFMJNJUTTIPXOJOUIFUBCMFCFMPX
"NQNFBTVSFNFOUGPSTFDPOETNBYJNVN
t0INTDBOOPUCFNFBTVSFEJGWPMUBHFJTQSFTFOUPINTDBOCFNFBTVSFEPOMZJOBOPOQPXFSFEDJSDVJU
)PXFWFSUIFNFUFSJTQSPUFDUFEUPWPMUT
Meter Basics
1. Digital and Analog display features:
B4ZNCPMTUPJEFOUJGZGVODUJPO
C'PVSDIBSBDUFSEJHJUBMEJTQMBZ
D"OBMPHCBSHSBQI
5IFEJHJUBMEJTQMBZJTCFTUGPSTUBCMFJOQVU5IFCBS
HSBQIJTCFTUGPSSBQJEMZDIBOHJOHJOQVU
2. Function Buttons:
1SFTTUIFCVUUPOUPTFMFDUBGVODUJPO"TZNCPMXJMM
EJTQMBZUPWFSJGZZPVSDIPJDF
3. Rotary Selector Switch:
5VSOUIJTTXJUDIUPTFMFDUBGVODUJPOPSUVSOUIF
NFUFS0''
4. Temperature Terminal:
*OTFSUUIFUFNQFSBUVSFQSPCFJOUIJTUFSNJOBM
5. Test Lead Terminals:
5IF#MBDLUFTUMFBEJTVTFEJOUIFDPNNPO$0.UFSNJOBMGPS
BMMUFTUT5IF3FEUFTUMFBEJTVTFEUPNFBTVSF"NQTPS7PMUT
FUNCTION Terminal Inputlimit
AC Volts 750 Volts AC RMS
DC Volts 1000 Volts DC
Frequency 500 Volts AC/DC
Ohm (resistance)
Diode
AC/DCμAmA μA/mA 320mA AC/DC
AC/DC 10A 10A *10A AC/DC
RPM
Duty Cycle (%)
Dwell Angle
V-ɏ-RPM 500 Volts AC/DC
250 Volts AC/DC
V-ɏ-RPM
V-ɏ-RPM
ATD5570
OFF
RPM
RPM
%duty
320Hz
3200Hz
32KHz
1400°F
320°F
750°C
320°C
ȍ
Dual
2CYL
3CYL
4CYL
4CYL
5CYL
8CYL
Automotive Meter
HOLD
RANGE
STROKE
V
V
TEMP
COM
10
9ȍ530
μAmA
10A
42DIS
mA μA
1000VDC
750VDC
MAX
300mA
FUSED
10A MAX
FUSED
AC
DC
Hz kHz
μA mA
mVA
%
0.ȍ
0102030
D
CB
D
#MBDL
3FE

Digital and Analog Display
1SFTTRANGECVUUPOUPNBOVBMMZTFMFDUBSBOHF
1SFTTAlt FunctionCVUUPOUPTFMFDU"MUFSOBUJOH$VSSFOU"$PS%JSFDU$VSSFOU%$
1SFTTHoldUPIPMEEBUBEJTQMBZPSSFTVNFUFTUJOH
RPM5BDI
Negative Polarity Indicator
Continuity Test
8IFODwellPGDZMJOEFSTJTTFMFDUFEXJUIUIFSPUBSZTXJUDI
Low Battery3FQMBDFUIFNBTUFSCBUUFSZXIFOUIJTTZNCPMEJTQMBZT
Analog Bar Graph Displaywith Polarity
Units of measure:
,JMPL
)FSU[)[
.JMMJN
7PMUT7
NFHBN
PINTȰ
EXFMMEFHSFFT
EVUZQFSDFOU
Function and Range Select
5VSOUIFSPUBSZTXJUDIJOFJUIFSEJSFDUJPOUPTFMFDUBGVODUJPO
.PTUGVODUJPOTBMTPIBWFSBOHFT"MXBZTTFMFDUBSBOHFIJHIFSUIBO
ZPVFYQFDUUIFDVSSFOUPSWPMUBHFUPCF5IFOTFMFDUBMPXFSSBOHF
JGCFUUFSBDDVSBDZJTOFFEFE
t*GUIFSBOHFJTUPPIJHIUIFSFBEJOHTBSFMFTTBDDVSBUF
t*GUIFSBOHFJTUPPMPXUIFNFUFSTIPXTOLPWFSMJNJU
AC
DC
Hz kHz
μA mA
mVA
%
0.ȍ
0102030
D
)
ATD5570
OFF
RPM
RPM
%duty
320Hz
3200Hz
32KHz
1400°F
320°F
750°C
320°C
ȍ
Dual
2CYL
3CYL
4CYL
4CYL
5CYL
8CYL
Automotive Meter
HOLD
RANGE
STROKE
V
V
10
42DIS
mA μA

Push Button Functions
Alternate Function Button:
1SFTTUIFAlternate Function
CVUUPOUPUPHHMFCFUXFFO%$BOE
"$JOUIFDVSSFOUNFBTVSFNFOUT
Range Select:
5IFSBOHFJTBVUPNBUJDBMMZ
TFMFDUFECZUIFNFUFS:PVDBO
BMTPNBOVBMMZTFMFDUBSBOHF
XJUIJOBGVODUJPOCZQSFTTJOHUIF
RangeCVUUPO
Range Exit:
5PFYJUUIFRangeNPEFBOE
SFUVSOUPBVUPSBOHJOHQSFTTBOE
IPMEUIFRangeCVUUPOGPS
TFDPOET
Note:
· If the range is too high, the readings are less accurate.
· If the range is too low, the meter shows OL (over limit).
Data Hold:
5IFData HoldGFBUVSFTUPSFTUIFMBTU
SFBEJOHJONFNPSZ1SFTTUIFData
HoldCVUUPOPODFUPIPMEUIFQSFTFOU
SFBEJOH1SFTTUIFData HoldCVUUPO
BHBJOUPFYJUBOESFTVNFSFBEJOHT
ATD5570
OFF
RPM
RPM
%duty
320Hz
3200Hz
32KHz
1400°F
320°F
750°C
320°C
ȍ
Dual
2CYL
3CYL
4CYL
4CYL
5CYL
8CYL
Automotive Meter
HOLD
RANGE
STROKE
V
V
TEMP
COM
10
9ȍ530
μAmA
10A
42DIS
mA μA
1000VDC
750VDC
MAX
300mA
FUSED
10A MAX
FUSED
DC
0102030
V
V
ATD5570
OFF
RPM
RPM
%duty
320Hz
3200Hz
32KHz
1400°F
320°F
750°C
320°C
ȍ
Dual
2CYL
3CYL
4CYL
4CYL
5CYL
8CYL
Automotive Meter
HOLD
RANGE
STROKE
V
V
TEMP
COM
10
9ȍ530
μAmA
10A
42DIS
mA μA
1000VDC
750VDC
MAX
300mA
FUSED
10A MAX
FUSED
DC
0102030
ATD5570
OFF
RPM
RPM
%duty
320Hz
3200Hz
32KHz
1400°F
320°F
750°C
320°C
ȍ
Dual
2CYL
3CYL
4CYL
4CYL
5CYL
8CYL
Automotive Meter
HOLD
RANGE
STROKE
V
V
TEMP
COM
10
9ȍ530
μAmA
10A
42DIS
mA μA
1000VDC
750VDC
MAX
300mA
FUSED
10A MAX
FUSED
0102030
V

ATD5570
OFF
RPM
RPM
%duty
320Hz
3200Hz
32KHz
1400°F
320°F
750°C
320°C
ȍ
Dual
2CYL
3CYL
4CYL
4CYL
5CYL
8CYL
Automotive Meter
HOLD
RANGE
STROKE
V
V
TEMP
COM
10
9ȍ530
μAmA
10A
42DIS
mA μA
1000VDC
750VDC
MAX
300mA
FUSED
10A MAX
FUSED
DC
0102030
Meter Functions - Voltage (DCV)
5IFNFUFSXJMMBVUPNBUJDBMMZTFMFDUUIFCFTUVoltage7SBOHF
*OTFSU
t#MBDLMFBEJOCOMUFSNJOBM
t3FEMFBEJOV-Ω-RPMUFSNJOBM
5PVDIUIF#MBDLQSPCFUPHSPVOEPSUPUIFOFHBUJWFDJSDVJU
5PVDIUIF3FEQSPCFUPUIFDJSDVJUDPNJOHGSPNUIFQPXFS
TPVSDF
IMPORTANT: Voltage must be measured in parallel (Red probe
measuring circuit from power source).
Accuracy
t4FMFDUJPOPGBMPXFSSBOHFXJMMNPWFUIFEFDJNBMQPJOUPOF
QMBDFBOEJODSFBTFUIFBDDVSBDZ
"OiOLwEJTQMBZNFBOTUIFSBOHFJTUPPMPXTFMFDUUIFOFYU
IJHIFSSBOHF
WARNING
When measuring voltage, be sure the red test lead is in the terminal
marked “V”. If the test lead is in an Amp (A) or Milliampere (mA) terminal,
you may be injured or the meter may be damaged.

Meter Functions - Resistance (Ω)
IMPORTANT: *GZPVBSFUFTUJOHBOBQQMJDBUJPOUIBUIBTDBQBDJUPST
JOUIFDJSDVJUCFTVSFUPUVSOUIFQPXFS0''POUIFUFTUDJSDVJUBOE
EJTDIBSHFBMMDBQBDJUPST"DDVSBUFNFBTVSFNFOUJTOPUQPTTJCMFJG
FYUFSOBMPSSFTJEVBMWPMUBHFJTQSFTFOU
t4FMFDUUIFResistance (Ω)SBOHFXJUIUIFSPUBSZTXJUDI
4FMFDUUIFResistance (Ω)SBOHFXJUIUIFCVUUPOMBCFMFE
RangeJGNPSFBDDVSBUFNFBTVSFNFOUJTEFTJSFE
*OTFSU
t#MBDLMFBEJOCOMUFSNJOBM
t3FEMFBEJOV-Ω-RPMUFSNJOBM
t5PVDIUIFUFTUMFBEQSPCFTBDSPTTUIFSFTJTUPSUPCFUFTUFE
ATD5570
OFF
RPM
RPM
%duty
320Hz
3200Hz
32KHz
1400°F
320°F
750°C
320°C
ȍ
Dual
2CYL
3CYL
4CYL
4CYL
5CYL
8CYL
Automotive Meter
HOLD
RANGE
STROKE
V
V
TEMP
COM
10
9ȍ530
μAmA
10A
42DIS
mA μA
1000VDC
750VDC
MAX
300mA
FUSED
10A MAX
FUSED
0.ȍ
0102030

Meter Functions – Diode Check ( )
IMPORTANT: 5VSOUIFQPXFS0''UPUIFUFTUDJSDVJU
t4FMFDUUIFDiode CheckTFUUJOHXJUIUIFSPUBSZTXJUDI
*OTFSU
t#MBDLMFBEJOCOM UFSNJOBM
t3FEMFBEJOV-Ω-RPM UFSNJOBM
5PVDIUIF#MBDLUFTUQSPCFUPUIFOFHBUJWFTJEFPGUIFEJPEF
5PVDIUIF3FEUFTUQSPCFUPUIFQPTJUJWFTJEFPGUIFEJPEF
3FWFSTFUIFQSPCFT#MBDLUPUIFQPTJUJWFTJEFBOE3FEUPUIF
OFHBUJWFTJEF
Note:
A good diode will read low in one direction and high in the other
direction when the probes are reversed (or vice versa). A defective
diode will have the same reading in both directions or read
between 1.0 to 3.0V. in both directions.
Diode (-) to (+) Reverse Probes
(-) to (+)
.4 to .9V OL
OL .4 to .9V
OL 1.0 to 3.0V
1.0 to 3.0V OL
.4 to .9V .4 to .9V
OL OL
.000V .000V
Good
Bad
ATD5570
OFF
RPM
RPM
%duty
320Hz
3200Hz
32KHz
1400°F
320°F
750°C
320°C
ȍ
Dual
2CYL
3CYL
4CYL
4CYL
5CYL
8CYL
Automotive Meter
HOLD
RANGE
STROKE
V
V
TEMP
COM
10
9ȍ530
μAmA
10A
42DIS
mA μA
1000VDC
750VDC
MAX
300mA
FUSED
10A MAX
FUSED
0102030

Meter Functions – Audible Continuity ( )
IMPORTANT: 5VSOUIFQPXFS0''UPUIFUFTUDJSDVJU
4FMFDUUIFAudible Continuity TFUUJOHXJUI
UIFSPUBSZTXJUDI
*OTFSU
t#MBDLMFBEJOCOMUFSNJOBM
t3FEMFBEJOV-Ω-RPMUFSNJOBM
5PVDIPOFUFTUQSPCFUPFBDIFOEPGUIFDJSDVJUUP
CFUFTUFE
*GUIFDJSDVJUJTDPNQMFUFUIFNFUFSXJMMCFFQ
DPOUJOVPVTMZ
*GUIFDJSDVJUJTPQFOUIFSFXJMMCFOPCFFQBOEUIF
EJTQMBZXJMMTIPXiwPWFSMJNJU
$JSDVJUDPNQMFUFNFUFSXJMMCFFQDPOUJOVPVTMZ
$JSDVJUPQFO
.FUFSXJMM/05CFFQ
ATD5570
OFF
RPM
RPM
%duty
320Hz
3200Hz
32KHz
1400°F
320°F
750°C
320°C
ȍ
Dual
2CYL
3CYL
4CYL
4CYL
5CYL
8CYL
Automotive Meter
HOLD
RANGE
STROKE
V
V
TEMP
COM
10
9ȍ530
μAmA
10A
42DIS
mA μA
1000VDC
750VDC
MAX
300mA
FUSED
10A MAX
FUSED
0.ȍ
0102030

Meter Functions – AC or DC Current (A)
IMPORTANT: "MMDVSSFOUNFBTVSFEøPXTUISPVHIUIF
NFUFS*UJTJNQPSUBOUUIBUZPVDO NOT
t.FBTVSFDVSSFOUHSFBUFSUIBO7"$PS%$XJUI
SFTQFDUUPHSPVOE
t&YDFFETFDPOETXIFONFBTVSJOHDPOUJOVPVT
DVSSFOUCFUXFFO"NQT"MMPXöWFNJOVUFTGPSDPPM
EPXOCFGPSFDPOUJOVJOH
To Measure:
t4FMFDUUIF"N"PS"SBOHFXJUIUIFSPUBSZTXJUDI
t1SFTTUIFAlternate FunctionCVUUPOUPTFMFDU"$PS%$
*OTFSU
t#MBDLMFBEJOCOMUFSNJOBM
t3FEMFBEJOUIF"PSN"UFSNJOBM4FMFDUUIF"
UFSNJOBMJGZPVBSFVOTVSFPGUIFDVSSFOUESBX
IMPORTANT:
Turn OFF all power to the circuit or disconnect the circuit
from the power source.
$POOFDU
t5IF3FEQSPCFUPUIFTJEFPGUIFDJSDVJUDMPTFTUUPUIF
QPXFSTPVSDF
t5IF#MBDLQSPCFUPUIFTJEFPGUIFDJSDVJUUPHSPVOE
t5VSOUIFQPXFS0/BOEUFTU
Note:
Current must always be measured with the meter
test probes connected in series as described.
ATD5570
OFF
RPM
RPM
%duty
320Hz
3200Hz
32KHz
1400°F
320°F
750°C
320°C
ȍ
Dual
2CYL
3CYL
4CYL
4CYL
5CYL
8CYL
Automotive Meter
HOLD
RANGE
STROKE
V
V
TEMP
COM
10
9ȍ530
μAmA
10A
42DIS
mA μA
1000VDC
750VDC
MAX
300mA
FUSED
10A MAX
FUSED
DC
A
0102030

Meter Functions – Temperature (°C / °F)
IMPORTANT:5PBWPJEIFBUEBNBHFUPUIFNFUFS
LFFQJUBXBZGSPNTPVSDFTPGWFSZIJHIUFNQFSBUVSF
5IFMJGFPGUIFUFNQFSBUVSFQSPCFJTBMTPSFEVDFE
XIFOTVCKFDUFEUPWFSZIJHIUFNQFSBUVSFT1SPCF
PQFSBUJOHSBOHFJTo¡UP¡'
t4FMFDUUIFTemperature VOJUPGNFBTVSFXJUIUIF
SPUBSZTXJUDI¡$¡'
t*OTFSUUIFUFNQFSBUVSFQSPCFDPOOFDUPSJOUPUIF
,UZQFUIFSNPDPVQMFTPDLFU
t5PVDIUIFFOEPGUIFUFNQFSBUVSFTFOTPSUPUIF
BSFBPSTVSGBDFPGUIFPCKFDUUPCFNFBTVSFE
ATD5570
OFF
RPM
RPM
%duty
320Hz
3200Hz
32KHz
1400°F
320°F
750°C
320°C
ȍ
Dual
2CYL
3CYL
4CYL
4CYL
5CYL
8CYL
Automotive Meter
HOLD
RANGE
STROKE
V
V
TEMP
COM
10
9ȍ530
μAmA
10A
42DIS
mA μA
1000VDC
750VDC
MAX
300mA
FUSED
10A MAX
FUSED
0102030
5FNQFSBUVSF
4FOTPS
5FNQFSBUVSF
1SPCF

Meter Functions – Frequency (Hz)
t4FMFDUUIFFrequency (FREQ) TFUUJOHXJUIUIFSPUBSZTXJUDI
t4FUUIFSPUBSZTXJUDIUPUIFGSFRVFODZSBOHFUIBUHJWFTUIF
NPTUBDDVSBUFNFBTVSFNFOUSFBEJOH
*OTFSU
t#MBDLMFBEJOCOMUFSNJOBM
t3FEMFBEJOV-Ω-RPMUFSNJOBM
$POOFDUUIF#MBDLUFTUQSPCFUPHSPVOE
$POOFDUUIF3FEUFTUQSPCFUPUIFSignal OutXJSFPGUIF
TFOTPSUPCFUFTUFE
ATD5570
OFF
RPM
RPM
%duty
320Hz
3200Hz
32KHz
1400°F
320°F
750°C
320°C
ȍ
Dual
2CYL
3CYL
4CYL
4CYL
5CYL
8CYL
Automotive Meter
HOLD
RANGE
STROKE
V
V
TEMP
COM
10
9ȍ530
μAmA
10A
42DIS
mA μA
1000VDC
750VDC
MAX
300mA
FUSED
10A MAX
FUSED
Hz
0102030
(SPVOE
4JEF
4JHOBM0VU
4JEF
7PMUBHF*O
4JEF

Meter Functions – Dwell
t4FMFDUUIFQSPQFSDwellSBOHFXJUIUIFSPUBSZTXJUDI
*OTFSU
t#MBDLMFBEJOCOMUFSNJOBM
t3FEMFBEJOV-Ω-RPM UFSNJOBM
$POOFDUUIF#MBDLUFTUQSPCFUPHSPVOE
$POOFDUUIF3FEUFTUQSPCFUPUIFXJSFUIBUDPOOFDUTUPUIF
CSFBLFSQPJOUTTFFJMMVTUSBUJPO
ATD5570
OFF
RPM
RPM
%duty
320Hz
3200Hz
32KHz
1400°F
320°F
750°C
320°C
ȍ
Dual
2CYL
3CYL
4CYL
4CYL
5CYL
8CYL
Automotive Meter
HOLD
RANGE
STROKE
V
V
TEMP
COM
10
9ȍ530
μAmA
10A
42DIS
mA μA
1000VDC
750VDC
MAX
300mA
FUSED
10A MAX
FUSED
0102030
5P#SFBLFS
1PJOUT
5P(SPVOE

Meter Functions – Duty Cycle (%)
t4FMFDUUIFDuty CycleSBOHFXJUIUIFSPUBSZTXJUDI
*OTFSU
t#MBDLMFBEJOCOMUFSNJOBM
t3FEMFBEJOV-Ω-RPMUFSNJOBM
$POOFDUUIF#MBDLUFTUQSPCFUPHSPVOE
$POOFDUUIF3FEUFTUQSPCFUPUIFTJHOBMXJSFDJSDVJUTFF
JMMVTUSBUJPO
5IFJMMVTUSBUJPOGPSBNJYUVSFDPOUSPMTPMFOPJEJTTIPXO
XJUIUIFNFUFSJOHSPEJOUIFDMPTFEQPTJUJPO5IFNFUFS
XJMMEJTQMBZUIFQFSDFOUBHFPGUJNFUIFQMVOHFSJTJOUIF
DMPTFEQPTJUJPOMPXEVUZDZDMFEVSJOHPOFEVUZDZDMF
ATD5570
OFF
RPM
RPM
%duty
320Hz
3200Hz
32KHz
1400°F
320°F
750°C
320°C
ȍ
Dual
2CYL
3CYL
4CYL
4CYL
5CYL
8CYL
Automotive Meter
HOLD
RANGE
STROKE
V
V
TEMP
COM
10
9ȍ530
μAmA
10A
42DIS
mA μA
1000VDC
750VDC
MAX
300mA
FUSED
10A MAX
FUSED
%
0102030
.JYUVSF
$POUSPM
4IPXO
5P(SPVOE
5P&$.

Meter Functions – RPM / x10 RPM
t4FMFDUUIFRPMSBOHFXJUIUIFSPUBSZTXJUDI
OR
t4FMFDUUIFx10 RPMSBOHFXJUIUIFSPUBSZTXJUDI
UPSQN.VMUJQMZUIFEJTQMBZFESFBEJOHUJNFTCZ
UPHFUBDUVBMSQN
1SFTTSTROKECVUUPOBOEDZDMFUISPVHI31.GPS
TUSPLF31.GPSTUSPLFBOE%*4
t*OTFSUUIFJOEVDUJWFQJDLVQDPOOFDUJOHUFSNJOBM
JOUPUIFNFUFS
t(SPVOEMFBEJOCOMUFSNJOBM
t0VUQVUMFBEJO V -Ω- RPMUFSNJOBM
t$POOFDUUIFJOEVDUJWFQJDLVQUPBTQBSLQMVHXJSF
*GOPSFBEJOHJTSFDFJWFEVOIPPLUIFDMBNQUVSOJU
PWFSBOEDPOOFDUBHBJO
Note:
t1PTJUJPOUIFJOEVDUJWFQJDLVQBTGBSBXBZGSPNUIF
distributor and the exhaust manifold as possible.
t1PTJUJPOUIFJOEVDUJWFQJDLVQUPXJUIJOTJYJODIFT
of the spark plug or move it to another plug wire if
no reading or an erratic reading is received.
RPM 4'PSrpmPGTUSPLFFOHJOFT
XIJDIIBWFJHOJUJPOPOFWFSZFOHJOFTUSPLFT
RPM 2'PSRPMPG%*4BOETUSPLFFOHJOFT
XIJDIIBWFJHOJUJPOPOFWFSZFOHJOFTUSPLFT
ATD5570
OFF
RPM
RPM
%duty
320Hz
3200Hz
32KHz
1400°F
320°F
750°C
320°C
ȍ
Dual
2CYL
3CYL
4CYL
4CYL
5CYL
8CYL
Automotive Meter
HOLD
RANGE
STROKE
V
V
TEMP
COM
10
9ȍ530
μAmA
10A
42DIS
mA μA
1000VDC
750VDC
MAX
300mA
FUSED
10A MAX
FUSED
0102030
DIS. 4
2

Maintenance
Fuse and Battery Replacement
t"WPJEFMFDUSJDBMTIPDLREMOVE TEST LEADS BEFORE OPENING CASE!
t%POPUPQFSBUFUIFNFUFSPSSPUBUFUIFNFUFSTXJUDIXIFOUIFDBTFJTPQFO
5PSFQMBDFBCBUUFSZPSGVTFSFNPWFSFESVCCFSQSPUFDUJWFDBTFUIFOMPPTFO
UIFUISFFTDSFXTJOUIFDBTFCBDLBOESFNPWFUIFDBTFCZMJGUJOHVQBOE
GPSXBSE
3FQMBDFUIFCBUUFSZXJUIBO7BMLBMJOFCBUUFSZ
Important:
t5PQSFWFOUDPOUBNJOBUJPOPGUIFDJSDVJUTZPVSIBOETNVTUCFDMFBOBOEUIF
QSJOUFEDJSDVJUCPBSENVTUCFIFMECZUIFFEHFT
t3FQMBDFUIFGVTFTXJUIUIFTBNFUZQFPGGVTF
t5IF"GVTFJTSBUFEBU7BOEJTBIJHIFOFSHZGBTUBDUJOHGVTF
t5IFN"JTB7GBTUBDUJOHGVTF
t.BLFTVSFUIFSFQMBDFNFOUGVTFJTDFOUFSFEJOUIFGVTFIPMEFS
3FBTTFNCMFUIFDBTF'BTUFOUIFUISFFTDSFXTBOETMJEFNFUFSCBDLJOUPJUT
SFESVCCFSQSPUFDUJWFDBTF
WARNING
TO AVOID ELECTRICAL SHOCK
REMOVE TEST LEADS BEFORE
OPENING THE BATTERY CAP.
4DSFXT
4IPXO-PPTFOFE
'VTF"7&4*
'VTFN"7&4*
#BUUFSZ
WARNING

Troubleshooting
1. Meter wilI not turn ON.
t$IFDLUIFCBUUFSZDPOUBDUTGPSBUJHIUöU
t$IFDLGPSBNJOJNVNCBUUFSZWPMUBHFPGWPMUT
2. Ampere reading is erratic or there is no reading at all.
t%JTBTTFNCMFUIFNFUFSCBDLDPWFSBOEUFTUUIFGVTFTGPSDPOUJOVJUZ
3. Meter reading is erratic.
t1SJOUFEDJSDVJUCPBSEDPOUBNJOBUFEGSPNIBOEMJOHXJUIIBOET
t-PXCBUUFSZ
t0QFODJSDVJUJOBUFTUMFBEGSBZFEPSCSPLFOXJSF
t8SPOHSBOHFTFMFDUFE
t#MPXOGVTF
4. Meter readings do not change.
tHoldGFBUVSFJTTUJMMUPHHMFE0/
GENERAL SPECIFlCATIONS:
tDisplayEJHJUDPVOUTMJRVJEDSZTUBMEJTQMBZ-$%XJUIGVODUJPOBOEVOJUTTJHOBOOVODJBUPST
tAnalog Bar GraphTFHNFOUTXJUINFBTVSFNFOUTUJNFTQFSTFDPOE
tPolarity"VUPNBUJDOFHBUJWFQPMBSJUZJOEJDBUJPO
tOver Range Indicationi0-wNBSLJOEJDBUJPO
tLow Battery Indication5IFJTEJTQMBZFEXIFOUIFCBUUFSZWPMUBHFESPQTCFMPXUIFPQFSBUJOHMFWFM
tMeasurement RateUJNFTQFSTFDPOEOPNJOBM
tOperating Environment¡UP¡$¡'UP¡'BU3)
tStorage Environment¡UP¡$¡UP¡'BU3)
tTemperature Coecient¨TQFDJöFEBDDVSBDZ¡$¡$PS¡$
tPower4JOHMFTUBOEBSE7CBUUFSZ/&%"PS*&$'
tBattery LifeIPVSTUZQJDBMXJUIBMLBMJOFCBUUFSZ
tFuses"7¨NNGBTUBDUJOHDFSBNJDUZQF
"7¨NNGBTUBDUJOHDFSBNJDUZQF
tDimensionsNN)¨NN8¨NN%
tWeight"QQSPYHNFUFSPOMZHXJUIIPMTUFS

ELECTRICAL SPECIFICATIONS:
"DDVSBDZJTHJWFOBT<PGSFBEJOH><OVNCFSPGMFBTUTJHOJöDBOUEJHJUT>BU¡$UP¡$¡'UP¡'
XJUISFMBUJWFIVNJEJUZVQUP
RPM (Tach):
3BOHFT31.¨31.
3BOHFT31.%*4¨31.
3FTPMVUJPOSQN
&òFDU3FBEJOHSQN
"DDVSBDZSEHEHUT
0WFSMPBE1SPUFDUJPO7%$PS3.4"$
%DUTY CYCLE:
3BOHFT
3FTPMVUJPO
1VMTFXJEUIɅTNT
"DDVSBDZSEHEHUT
0WFSMPBE1SPUFDUJPO7%$PS3.4"$
DWELL ANGLE:
/0PGDZMJOEFST
3BOHFT¡$:-¡$:-¡$:-¡$:-¡$:-¡$:-
3FTPMVUJPO¡
"DDVSBDZSEHEHUT
0WFSMPBE1SPUFDUJPO7%$PS3.4"$
TEMPERATURE:
3BOHFTUP¡UP¡'UP¡UP¡'
3FTPMVUJPO¡$¡'¡$¡'
"DDVSBDZSEH¡$SEH¡'
4FOTPS5ZQF,5IFSNPDPVQMF
*OQVU1SPUFDUJPO7%$PS7"$3.4
DC VOLTAGE (Autoranging):
3BOHFTN77777
3FTPMVUJPOɅ7
"DDVSBDZSEHEHU
*OQVU*NQFEFODF.Ȱ
0WFSMPBE1SPUFDUJPO7%$PS7"$3.4
AC VOLTAGE (Autoranging):
3BOHFT7777
3FTPMVUJPON7
"DDVSBDZSEHEHUTBU)[UP)[
*OQVU*NQFEFODF.Ȱ
0WFSMPBE1SPUFDUJPO7%$PS7"$3.4

ELECTRICAL SPECIFICATIONS CONTINUED...
CURRENT:
3BOHFTɅ"Ʌ"N"N""
3FTPMVUJPOɅ"
%$"DDVSBDZSEHEHUPOɅ"BOEN"SBOHFT
SEHEHUTPO"SBOHF
"$"DDVSBDZSEHEHUTPOɅ"BOEN"SBOHFT
SEHEHUTPO"SBOHF
'SFRVFODZ3FTQPOTF)[UP)[
7PMUBHF#VSEFO7POɅ"N"SBOHFT
7POɅ"N"SBOHFT
*OQVU1SPUFDUPO"7GBTUBDUJOHDFSBNJDGVTFPOɅ"N"JOQVU
"7GBTUBDUJOHDFSBNJDGVTFPO"JOQVU
RESISTANCE (Autoranging):
3BOHFTȰȰ,Ȱ.Ȱ.Ȱ
3FTPMVUJPONȰ
"DDVSBDZSEHEHUTPOȰUP,ȰSBOHFT
SEHEHUTPO.ȰSBOHF
SEHEHUTPO.ȰSBOHF
0WFSMPBE1SPUFDUPO7%$PS3.4"$
FREQUENCY:
3BOHFT)[)[,)[
3FTPMVUJPO)[
"DDVSBDZSEHEHUTPOBMMSBOHFT
4FOTJUJWJUZ73.4NJOBU>BOE<EVUZDZDMF
&òFDU3FBEJOH.PSFUIBOEJHJUTBUQVMTFXJEUI>Ʌ4FD
0WFSMPBE1SPUFDUJPO7%$PS3.4"$
DIODE TEST:
5FTUDVSSFOUN"UZQJDBM7G7
3FTPMVUJPON"
"DDVSBDZSEHEHUT
0QFO$JSDVJU7PMUBHF7%$UZQJDBM
0WFSMPBE1SPUFDUPO7%$PS3.4"$
"VEJCMF$POUJOVJUZ
"VEJCMF5ISFTIPME-FTTUIBOȰ
3FTPMVUJPONȰ
5FTUDVSSFOU<N"
0WFSMPBE1SPUFDUJPO7%$PS3.4"$
Table of contents
Other ATD Tools Measuring Instrument manuals

ATD Tools
ATD Tools 8658 User manual

ATD Tools
ATD Tools ATD-8658 User manual

ATD Tools
ATD Tools ATD-5585 User manual

ATD Tools
ATD Tools ATD-3696 User manual

ATD Tools
ATD Tools ATD-5549 User manual

ATD Tools
ATD Tools ATD-3305 User manual

ATD Tools
ATD Tools ATD-8660A User manual

ATD Tools
ATD Tools ATD-5536 User manual

ATD Tools
ATD Tools ATD-8657 User manual

ATD Tools
ATD Tools 12551 User manual