EH3305 / EH3005 Series
Unmanaged Fast Ethernet Switch
Version 1.0
Updated in December, 2020
P/N : 89900594G
Package Check List
Product Technical Specification
Product Layout
Inside the package you will find the following items:
■Industrial Unmanaged Ethernet Switch x 1
■5-Pin 5.08mm Lockable Terminal Block (Already mounted to the device) x 1
■DIN-Rail Kit (Already mounted to the device) x 1
■Installation Guide with Warranty Card x 1
1. Power input: 12-48VDC, 0.5A max.
2. Operating Temperature:
■EH3305: -40 to 70° C (-40° F to 158° F)
■EH3005: 0 to 60 ° C (32° F to 140° F)
3. Storage Temperature:
■EH3305: -40 to 85°C (-40°F to 185°F)
■EH3005: -20 to 70°C (-4°F to 158°F)
4. Ambient Relative Humidity: 5 to 95%, 55°C (non-condensing)
5. EH3305: IP30 protection
6. EH3005: IP40 protection
Warning: Hot Surface Do Not Touch. RESTRICTED ACCESS AREA: The equipment
should only be installed in a Restricted Access Area.
Never install or work on electrical or cabling during periods of lighting activity.
Never connect or disconnect power when hazardous gases are present.
1
P1 P2 ALM
2
3
4
5
EH3005 EH3305
1 2 1 2
33
5
5
6
7
4
4
Front View
EH3005 EH3305
Top View
1. P1 LED
2. P2 LED
3. Alarm LED
4. 10/100 BASE-T(X) Ports
5. Terminal for P2
6. Terminal for P1
7. Functional Ground
8. Grounding Screw
F.G.
V2+
V1+
V2
V1
F.G.
V2+
V1+
V2
V1
5
6
7
8
P1 P2 ALM
1
P1 P2 ALM
2
3
4
5
6. Next we can then proceed to connect
the device to the LAN (switch or PC,
depending on the case), take care on
using the RJ-45 connector; after this we
can then proceed to the device’s settings.
4. Wall mount Screw spec. : M3
Screw depth : 4.0 mm(Max)
Screw : 4 PCS
3. You can then choose whether to plug in
the I/O ports at this point or do it later
depending on the actual location of the
device or level of comfort for performing
such operation. Remember to plug in the
protective caps for the unused SFP and
PoE ports.
5. Once the plate has been firmly put in
place, proceed to mount the whole device
as shown in (Fig. 4).
Proceed to (Fig. 5) if you want to remove
the device from DIN-Rail.
1
2
(Fig. 4)
1
2
(Fig. 5)
(Fig. 2) (Fig. 3)
F.G.
V2+
V1+
V2
V1
F.G.
V2+
V1+
V2
V1
■ The opening to the sides are for the
device’s heat dissipation please never
obstruct or cover them with any objects or
try to insert them through it. Please keep
minimum 5 CM distance with others
device. (Fig. 2~3 & Fig. 6~7) (Fig. 6) (Fig. 7)
7. Din Rail screw
Screw spec. : M4
Screw depth: 6.0mm(Max.)
Screw : 3 pcs
Installation Overview
The device’s appearance is as in the figure below.
1. If you have purchased the wall mount
kit, proceed to place the screws on the
back of the device as shown in (Fig. 1)
2. Although internal grounding has been
done inside, in order to ensure overall
maximum performance and protect your
device it is still strongly advised to ground
the device properly; hazardous ESD can
come into contact with it and damage
your equipment. On the power terminal
block, there is a terminal for Frame
Ground, you can choose whether to
connect it to the grounding or you may opt
to connect to the grounding screw next to
the terminal block (the one chosen should
be connected at all times) (Fig. 2~3).
(Fig. 1)
Pin Assignments and Connections
10/100/1000BASE-T(X) Ethernet and PoE Pinouts
RJ-45
Pin 1 2 3
Signal Tx+ Tx - Rx+ Rx-
4 5 6 7 8
1 8
10/100BASE-T(X)
1000BASE-T
Pin 1 2 3
Signal BI_DA+ BI_DA- BI_DB+ BI_DB- BI_DD+ BI_DD-BI_DC+ BI_DC-
4 5 6 7 8
LED Indicators
LED Color State Description
Power is supplied from P1/P2On
Off
On
On
Off
RedALM
GreenP1/P2
BlinkingAmber
LAN
Off
BlinkingGreen
On
Off
No power input detected from P1/P2
P1 or P2 input is disconnected or failed
Power input status is normal
Ethernet is linked at 10/100Mbps
Ethernet is active and data is being transmitted
Ethernet is not linked
Ethernet is linked at 1000Mbps
Ethernet is active and data is being transmitted
Ethernet is not linked
Attention
■It is recommend to use at least 20 AWG cable and the cable needs to be resistant
to at least 85°C on the power connector.
■Torque applied to the Terminal block’s screw should be 4.5 in. lb (0.51 Nm)
■The device needs to be installed inside a Type 1 housing.
■Frame or chassis terminal (châssis ou borne de chassis)
■The device is open type equipment.
■Use copper conductor only.
■This device needs to be installed in an area of pollution degree 2 or less D. If the
equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.
■Clean the device with a soft dry cloth.
■Use only SELV or UL61010-1 double insulation evaluated power source or
61010-2-201 power supply.
■The device with 5 RJ-45 ports for your industrial applications. It designs to work
in the industrial environment, such as in hazardous locations that comply with CE,
FCC and UL standards. The slim design is useful for the application with limited
cabinet space.
Mechanical Dimensions (Unit=mm)
EH3005
EH3305
Rear View
Bottom ViewTop View
Side ViewFront View
Rear View
Top View
Side ViewFront View
Bottom View
23
94
72 12.5
60
F.G.
V2+
V1+
V2
V1
108.4
117.4
13
F.G.
V2+
V1+
V2
V1
P1 P2 ALM
1
P1 P2 ALM
2
3
4
5
94
29.536.5
25
21
4.4
72
1
P1 P2 ALM
2
3
4
5
If the device requires servicing of any kind, you may need to disconnect and remove
it from its mounting. The initial installation should be done in a way that makes this
as convenient as possible.
■ Voltage/Power lines should be properly insulated as well as other cables. Be
careful when handing the so as to not trip over.
■ Do not under any circumstance insert foreign objects of any kind into the heat
dissipation holes located in the different faces of the device. This may not only harm
the internal layout but might cause harm to you as well.
■ Do not under any circumstance open the device for any reason. Please contact
your dealer for any repair needed or follow the instructions on section of your User’s
Manual.
Field Maintenance and Service
Customers shall always obtain an authorized "RMA" number from Atop before
shipping the goods to be repaired to Atop. When in normal use, a sold product
shall be replaced with a new one within 3 months after purchase. The shipping
cost from the customer to Atop will be reimbursed by Atop.
After 3 months and still within the warranty period, it is up to Atop whether to
replace the unit with a new one; normally, as long as a product is under warranty,
all parts and labor are free of charge to the customers.
After the warranty period, the customer shall cover the cost for parts and
labor.Three months after purchase, the shipping cost from the customer to Atop
will not be reimbursed, but the shipping cost from Atop to the customer will be
paid by Atop.
Atop shall not be held responsible for any consequential losses from using
Atop’s product.
Warranty Policy
The warranty certification will not be effective until an authorized stamp issued by
Atop’s overseas agents.
Purchase Date: / / (yyyy/mm/dd)
Serial Number
Product CategoriesWarranty WarrantyProduct Categories
Media Converters
Embedded Device Servers
Ethernet Switches
Wireless
Serial Device Servers
Modbus Gateways
DIN-Rail Power Supplies
Power Adaptors
Antennas
Other Accessories
Warranty Conditions
RMA and Shipping Costs Reimbursement
Limited Liability
1. Please contact your local dealers or Atop Technical Support Center at the
following numbers.
+ 886-3-550-8137 (Atop Taiwan)
+ 86-21-6495-6232 (Atop China)
2. Please report the defected problems via Atop’s Web site or E-mail account
Web Site:www.atop.com.tw, e-mail:[email protected]
Web Site:www.atop.com.cn, e-mail:[email protected]
3. Company Addr : 2F, No.146, Sec.1, Tung-Hsing Rd.,
Jubei, Hsinchu 302058, Taiwan
Manufacturer Addr : 1F, No.30, R&D Rd. II, Science-Based
Industrial Park, Hsinchu 300092, Taiwan
Atop Customer Services and Supports
Products supplied by Atop Technologies are covered in this warranty for
sub-standard performance or defective workmanship. The warranty is not,
however, extended to goods damaged in the following circumstances:
(a) Excessive forces or impacts
(b) War or an Act of God: wind storm, fire, flood, electric shock, earthquake
(c) Use of unqualified power supply, connectors, or unauthorized parts/kits
(d) Replacement with unauthorized parts
Warranty Period
─ Any changes to this material will be announced on Atop website. ─

This manual suits for next models

1

Other Atop Switch manuals

Atop EH7506-4PoE-2SFP User manual

Atop

Atop EH7506-4PoE-2SFP User manual

Atop EHG75 series User manual

Atop

Atop EHG75 series User manual

Atop EMG8508 Series Manual

Atop

Atop EMG8508 Series Manual

Atop EHG2408 Series Manual

Atop

Atop EHG2408 Series Manual

Atop EHG7504 Manual

Atop

Atop EHG7504 Manual

Atop EHG3005 Series Manual

Atop

Atop EHG3005 Series Manual

Atop EH2316 Series Manual

Atop

Atop EH2316 Series Manual

Atop RHG7528 Series Manual

Atop

Atop RHG7528 Series Manual

Atop EHG9508 Series Manual

Atop

Atop EHG9508 Series Manual

Atop EMG8510 Series Manual

Atop

Atop EMG8510 Series Manual

Atop ABLELink EH2006 User manual

Atop

Atop ABLELink EH2006 User manual

Atop CloudProof M1000 serious User manual

Atop

Atop CloudProof M1000 serious User manual

Atop EHG7305 Series User manual

Atop

Atop EHG7305 Series User manual

Atop EMG8305 Series Manual

Atop

Atop EMG8305 Series Manual

Atop EH3408ls User manual

Atop

Atop EH3408ls User manual

Atop EH9711 Series User manual

Atop

Atop EH9711 Series User manual

Popular Switch manuals by other brands

Lindy 39632 user manual

Lindy

Lindy 39632 user manual

HP 6125XLG Command reference

HP

HP 6125XLG Command reference

SMC Networks D-P3DW* Series Operation manual

SMC Networks

SMC Networks D-P3DW* Series Operation manual

Ramsey Electronics AVS10 instruction manual

Ramsey Electronics

Ramsey Electronics AVS10 instruction manual

Ekinex EK-TM1-TP user manual

Ekinex

Ekinex EK-TM1-TP user manual

evertz 7700 Series manual

evertz

evertz 7700 Series manual

OEZ BD250NE405 Instructions for use

OEZ

OEZ BD250NE405 Instructions for use

H3C CR19000-16 Installation, quick start

H3C

H3C CR19000-16 Installation, quick start

Brocade Communications Systems X6-4 Hardware installation guide

Brocade Communications Systems

Brocade Communications Systems X6-4 Hardware installation guide

Patton electronics 360 user manual

Patton electronics

Patton electronics 360 user manual

NETGEAR ProSAFE GS105Ev2 user manual

NETGEAR

NETGEAR ProSAFE GS105Ev2 user manual

NVT DigitalEQ NV-872 installation manual

NVT

NVT DigitalEQ NV-872 installation manual

HP BladeSystem bc2000 - Blade PC installation guide

HP

HP BladeSystem bc2000 - Blade PC installation guide

Edwards A50633000 instruction manual

Edwards

Edwards A50633000 instruction manual

Sonoff DIY  iFan03 quick start guide

Sonoff

Sonoff DIY iFan03 quick start guide

H3C S5500-EI series installation guide

H3C

H3C S5500-EI series installation guide

TRENDnet TK-210K Quick installation guide

TRENDnet

TRENDnet TK-210K Quick installation guide

Baseus BS-OH119 user manual

Baseus

Baseus BS-OH119 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.