Atop EMG8305 Series Manual

Industrial Unmanaged Gigabit Ethernet Switch
EMG8305 Series
Version 0.1
Updated in July, 2016
P/N:89900496G
Inside the package you will find the following items:
■ Industrial Managed Gigabit Ethernet Switch x 1
■ Installation Guide with Warranty Card x 1
Never install or work on electrical or cabling during periods of lightning activity.
Never connect or disconnect power when hazardous gases are present.
Warning:Hot Surface Do Not Touch.
EMG8305 Series
Power
5
4
P1
P2
3
2
5
4
3
2
1
1
LAN
V1+
V1- V2-
F.G.
V2+
BI_DC-
BI_DC+
BI_DA+ / Tx+
BI_DD+
BI_DD-
BI_DA- / Tx-
BI_DB+ / Rx+
BI_DB- / Rx-
12
5
63
7
4
8
1. LAN Port LED
2. PWR1 LED
3. PWR2 LED
4. 5-pin A-Coding Male of the power connector
5. 10/100/1000BaseT(X) 8-pin A-Coding Female or 8-Pin X-Coding Female
1
2
3
4
5
5
You can then choose whether to plug in the other peripheral ports at this point
or do it later depending on the actual location of the device or level of comfort
for performing such operation.
4.
If you have purchased the DIN-Rail kit, Once the plate has been firmly put in
place, proceed to mount the whole device as shown in (Fig. 4).
Proceed to (Fig. 5) if you want to remove the device from DIN-Rail.
5.
Next we can then proceed to connect the device to the LAN (switch or PC,
depending on the case), take care on using the M12 connector; after this we
can then proceed to the device’s settings
6.
Proceed to place the screws on the back of the device as show in (Fig. 1).
1.
If you have the Din-rail kit, proceed to place the screws on the back of the
device as show in (Fig. 2)
2.
3. Although internal grounding has been done inside, in order to ensure overall
maximum performance and protect your device, it is still strongly advised to
ground the device properly; hazardous ESD can come into contact and
damage your equipment. On the power terminal block, there is a terminal for
Frame Ground, you can choose whether to connect it to the grounding or you
may opt to connect to the grounding screw next to the terminal block ( the one
chosen should be connected at all times ) (Fig. 3)
2
1
2
1
2
■ The housing has a good thermal conductivity material, so the heat can be
dissipated to the outside through the housing by conduction-convection.
Color State
LED Deacription
PWR1
PWR2
LAN
Green
Amber
Green
On
Off
On
Blinking
Off
On
Blinking
Off
Power is supplied through PWR1or PWR2
Power is off
Ethernet is linked at 10/100Mbps
Ethernet is active and data is being transmitted
Ethernet is not linked
Ethernet is linked at 1000Mbps
Ethernet is active and data is being transmitted
Ethernet is not linked
■ Power input : 12 – 48 VDC
■ Current Input: 12V@ 0.42A
■ Power Consumption: 5W Max
72
63
81
54
M12
X-coded
Tx+ Tx- Rx+ Rx-
10/100/1000Base-T(X) Ethernet
1000Base-T
10/100Base-T(x)
M12
A-coded
Tx+Tx- Rx+ Rx-
1000Base-T
10/100Base-T(x)
3
6
7
4
5
8
21
M12
V2- V1-
Power
V1+ V2+ F.G.
Power Pinouts
1
3
5
4
2
If the device requires servicing of any kind, you may need to disconnect and
remove it from its mounting. The initial installation should be done in a way that
makes this as convenient as possible.
■ Voltage/Power lines should be properly insulated as well as other cables. Be
careful when handing the so as to not trip over
■ Do not under any circumstance open the device for any reason. Please
contact your dealer for any repair needed or follow the instructions on section
of your User’s Manual.
Field Maintenance and Service
Attention
1. The device needs to be installed in an area of pollution degree 2 or less.
2. If the equipment is used in a manner not specified by the manufacturer,
the protection provided by the equipment may not be impaired.
3. Clean the device with soft cloth with dry or water.
Environmental Limits
■ Operating Temperature: -40 to 75° C (-40° F to 167° F)
■ Storage Temperature: -40 to 85°C (-40 to 185°F)
■ Ambient Relative Humidity: 5 to 95%, 55°C (non-condensing)
■ Altitude: up to 2,000 m
Front View
Side View
Bottom View
The Din-rail kit illustrated in this document is for reference only and is not included in package.
196.0 172.0
18.0
25.0
32.0
100.0
105.7
34.5
30.0
63.7
36.0
30.9
4-M3xP0.5x6L
Customers shall always obtain an authorized "RMA" number from Atop before
shipping the goods to be repaired to Atop. When in normal use, a sold product
shall be replaced with a new one within 3 months after purchase. The shipping
cost from the customer to Atop will be reimbursed by Atop.
After 3 months and still within the warranty period, it is up to Atop whether to
replace the unit with a new one; normally, as long as a product is under warranty,
all parts and labor are free of charge to the customers.
After the warranty period, the customer shall cover the cost for parts and
labor.Three months after purchase, the shipping cost from the customer to Atop
will not be reimbursed, but the shipping cost from Atop to the customer will be
paid by Atop.
Atop shall not be held responsible for any consequential losses from using Atop’s
product.
Warranty Policy
The warranty certification will not be effective until an authorized stamp issued by
Atop’s overseas agents.
Purchase Date: / / (yyyy/mm/dd)
Serial Number
Product CategoriesWarranty WarrantyProduct Categories
Media Converters
Embedded Device Servers
Ethernet Switches
Wireless
Serial Device Servers
Modbus Gateways
DIN-Rail Power Supplies
Power Adaptors
Antennas
Other Accessories
Warranty Conditions
RMA and Shipping Costs Reimbursement
Limited Liability
1. Please contact your local dealers or Atop Technical Support Center at the
following numbers.
+ 886-3-550-8137 (Atop Taiwan)
+ 86-21-6495-6232 (Atop China)
2. Please report the defected problems via Atop’s Web site or E-mail account
Web Site:www.atop.com.tw, e-mail:[email protected]
Web Site:www.atop.com.cn, e-mail:[email protected]
3. Company Addr: 2F, No. 146, Sec. 1, Tung-Hsing Rd., Jubei, Hsinchu 30261,
Taiwan, R.O.C.
Manufacturer Addr: 1st FL 30 R&D RD II,SCIENCE-BASED INDUSTRIAL
PARK,HSINCHU 300 TAIWAN, R.O.C
Atop Customer Services and Supports
Products supplied by Atop Technologies are covered in this warranty for
sub-standard performance or defective workmanship. The warranty is not,
however, extended to goods damaged in the following circumstances:
(a) Excessive forces or impacts
(b) War or an Act of God: wind storm, fire, flood, electric shock, earthquake
(c) Use of unqualified power supply, connectors, or unauthorized parts/kits
(d) Replacement with unauthorized parts
Warranty Period
─ Any changes to this material will be announced on Atop website. ─

Other Atop Switch manuals

Atop EHG9508 Series Manual

Atop

Atop EHG9508 Series Manual

Atop EH7506-4PoE-2SFP User manual

Atop

Atop EH7506-4PoE-2SFP User manual

Atop CloudProof M1000 serious User manual

Atop

Atop CloudProof M1000 serious User manual

Atop EMG8508 Series Manual

Atop

Atop EMG8508 Series Manual

Atop RHG7528 Series Manual

Atop

Atop RHG7528 Series Manual

Atop ABLELink EH2006 User manual

Atop

Atop ABLELink EH2006 User manual

Atop EH9711 Series User manual

Atop

Atop EH9711 Series User manual

Atop EHG7504 Manual

Atop

Atop EHG7504 Manual

Atop EHG3005 Series Manual

Atop

Atop EHG3005 Series Manual

Atop EMG8510 Series Manual

Atop

Atop EMG8510 Series Manual

Atop EHG2408 Series Manual

Atop

Atop EHG2408 Series Manual

Atop EH3408ls User manual

Atop

Atop EH3408ls User manual

Atop EH2316 Series Manual

Atop

Atop EH2316 Series Manual

Atop EHG7305 Series User manual

Atop

Atop EHG7305 Series User manual

Atop EHG75 series User manual

Atop

Atop EHG75 series User manual

Atop EH3305 Series User manual

Atop

Atop EH3305 Series User manual

Popular Switch manuals by other brands

Ross SYNERGY 3.5 MD-X Ordering guide

Ross

Ross SYNERGY 3.5 MD-X Ordering guide

ANTAIRA LNP-0800G-M12-67-24 user manual

ANTAIRA

ANTAIRA LNP-0800G-M12-67-24 user manual

ScatterBox POE304 quick start guide

ScatterBox

ScatterBox POE304 quick start guide

Field Controls 46114900 manual

Field Controls

Field Controls 46114900 manual

Kramer WP-211T quick start guide

Kramer

Kramer WP-211T quick start guide

Alcatel-Lucent 1850 Installation and System Turn-Up Guide

Alcatel-Lucent

Alcatel-Lucent 1850 Installation and System Turn-Up Guide

LevelOne GTL-2890 manual

LevelOne

LevelOne GTL-2890 manual

D-Link xStack DGS-3420 Series reference guide

D-Link

D-Link xStack DGS-3420 Series reference guide

GarrettCom Magnum 6K32 Hardware installation and user's guide

GarrettCom

GarrettCom Magnum 6K32 Hardware installation and user's guide

Albalá Ingenieros IPA2000C01 manual

Albalá Ingenieros

Albalá Ingenieros IPA2000C01 manual

Cisco Catalyst 9500 Series Configuration guide

Cisco

Cisco Catalyst 9500 Series Configuration guide

Intermatic T1471BR supplementary guide

Intermatic

Intermatic T1471BR supplementary guide

X10 WS13A Set up and operating instructions

X10

X10 WS13A Set up and operating instructions

Mercoid DS-7000 Series Installation and operating instructions

Mercoid

Mercoid DS-7000 Series Installation and operating instructions

Profi-pumpe PSM01122V operating instructions

Profi-pumpe

Profi-pumpe PSM01122V operating instructions

Alcatel-Lucent 7210 SAS E OS Basic system configuration guide

Alcatel-Lucent

Alcatel-Lucent 7210 SAS E OS Basic system configuration guide

HP 2615 series Release notes

HP

HP 2615 series Release notes

D-Link xStack reference guide

D-Link

D-Link xStack reference guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.