
ST30BidataInstrument
2ST30 Bidata Service Manual 83009-2
Z171
Chapter 1. Special Functions
Specialfunctionsavailable on the ST30 Bidata are:
1. Calibration lock/unlock
2. Boatshow mode
3. Damping
Forsecurity reasons,extended calibrationfeatures are selected byan
extended hold (14seconds)of aand DEPTH until CAL isdisplayedfor the
secondtime,followed bymomentarydepressionof both the SPEED and
RESET keys.
Tocycle the features,press theDEPTHkeyuntil the requiredoptionis
displayed.
1.1 Calibration Lock/Unlock
Calibrationlock/unlockeliminatesthe risk of accidentally changing allbutthe
extended calibration values.
Thisfeatureis particularly useful foroperatorsofcharterboats who spenda
greatdealof time tuningthe pilot tothe vessel,onlyto find acustomer alters
thesettings at alaterdate.
Thisfeatureisdisplayedas C1orC0.
C1= unlocked (normalaccess)
C0= calibrationislocked(noaccess).
Themode is changedbypressingthe RESET key.
Calibrationlock/unlock isstored by pressing aandDEPTH for2seconds.
1.2 Boatshow Mode
Boatshowmode(S0 = disabled,S1 =enabled)is a demonstration
programmeto showthe featuresoftheinstrument.
Themode is changed bypressingRESET.
Note:Boatshow Modeautomatically resets tonormalmode ifatransduceris
connecteddirectlyto theinstrumentor ifthe instrumentispowereddown.
However, boatshowmode can be storedby:
1. Settingthe instrument to repeater mode
2. Selecting Boatshow Mode
3. Exitingfrom repeater mode