Rev.1.0
Key Function1.In normal display, The key function is call out adjustment display scale page
2.Into parameter setting page, the parameter mark & data is alternate display,
press key into setting procedure, The display is lock parameter data, this time must let off key
about 0.2 sec, press again, the parameter data will increment. (Key Response about 0.2 sec). If the
setting value have negative,Shift cursor(twinkle express) to the leftest and Press keycan positive
/negative number alternate display
&Key Function 1.In setting group or setting page press
&key return normal display, but if in setting page the
modify data will be lost
No Key in anything 1.
In setting group or setting page no key in anything about 2 minutes, return normal display, but if in
Setting page the modify data will be lost
Step
Parameter mark description
Parameter mark
Operation manual
1
Normal display
Press /FUNC key into P.CODE setting page
2
P.CODE(Pass code input page)
1.Key in 5 digit pass code with or key
2.Press key, the pass code is right into setting group, otherwise
return normal display
SYS(System setting group)
ROP(Alarm setting group)
AOP(Analog output setting
group)
3
DOP(Communication setting
group)
1.Select setting group with key
2.Press key into setting page of selection setting group
4
SYS(System setting group)
1.Press key decide SYS setting group , press key into DP setting
page
4-1
DP(Decimal Point)
Default = 0
1.Decide decimal point position with key (0~4)
2.Press key enter data and into TYPE setting page
4-2
TYPE(Type)
Default = 1U2G
1.Decide input type with key (1U2G,1G2U,1D2G,1G2D
,1U2D,1P2D,1A2B)
2. Press key enter data and into CNTS setting page
4-3
CNTS(Count Rates Select)
Default = 50KHZ
1.Decide Count Rates Select with key (50HZ,50KHZ)
2. Press key enter data and into P.OFF.M setting page
4-4
P.OFF.M(Power Off Mode)
Default = RESET
1.Decide Power Off Mode with key (RESET or MEMOR)
2. Press key enter data and into CODE setting page
Note:RESET(Power Off Reset):Count value and Alarm is reset
MEMOR(Power Off Memory) :Count value and Alarm is save
4-5
CODE(Pass Code)
Default = 0
1.Decide pass code with or key (0~99999)
2. Press key enter data and into LOCK setting page
4-6
LOCK(Panel Lock)
Default = NO
1. Decide panel lock with key(NO or YES)
2. Press key enter data and return SYS setting group
5
ROP( Alarm setting group)
1.Press key decide ROP setting group, press key into OP.MODE
setting page
5-1
OP.MODE(Output Mode )
Default = N
1. Decide output mode with key (N,F,R,Q,C,P,K)
2. Press key enter data and into ACT1.T setting page
5-2
ACT1.T(Active 1 Time )
Default = 0
1.Decide Active 1 Time with or key (0.0~99.9)sec.
2. Press key enter data and into ACT2.T setting page
3.ACT1.T=0 sec. is self-holding output 1
.ACT1.T=0.1~99.9 sec. is one-shot output 1
Note:When :OP.MODE=N, ACT1.T = 0 sec.
5-3
ACT2.T(Active 2 Time )
Default = 0
1. Decide Active 2 Time with or key (0.0~99.9)sec.
2. Press key enter data and return ROP setting group
3. ACT2.T=0 sec. is self-holding output 2
ACT2.T=0.1~99.9 sec. is one-shot output 2