AXE MMRD-M Series User manual

Rev.00
AXE
MICROPROCESS DUAL INPUT(MATH FUNCTION) RPM & LINE-SPEED CONTROLLER METER MMRD-M Series
■Features
◎Dual input measure and display sensor pulse or AC signal ◎16BIT DAC analog output can be modified,
◎Accuracy 0.03% F.S. ◎Four independent alarm with delay and hysteresis function
◎Input range(0~25KHz) ◎RS485 Communication interface, Protocol MODBUS RTU MODE
◎Readout range D1/D2(0~99999),D3(-19999~99999) ◎BAUD RATE:38400/19200/9600/4800/2400
◎RPM or LINE-SPEED can be modified ◎0.4" LED highlight display
◎Dual input math function(B-A,(B+A)/2,B/A,(B/A)-1,1-(B/A),B/(A+B))
◎Decimal point can be modified
◎Input pulse per revolution can be modified(1~99999) ◎Man-machine interface, easy to operate
◎Diameter(LINE-SPEED)/Scale(RPM) can be modified(0.0001~9.9999)
◎EEPROM Saving, data safekeeping about 10 years
◎Display average times can be modified(1~99) ◎Modified inside parameter, must have pass code
■Name of Parts
■Connect Diagram ■Input function jumper table
◎Contact input (PNP) ◎Sensor input (PNP 5V/12V)
◎Position 1 ON:IN(A)/IN(B) -> (NPN)
◎Contact input (NPN) ◎Sensor input (NPN 5V/12V)
◎Position 1 OFF:IN(A)/IN(B) -> (PNP)
◎Position 2 ON :IN(A)/IN(B) -> (0~50HZ)
◎Position 2 OFF:IN(A)/IN(B) -> (0~25KHZ)
■
Alarm Function
description
◎When ACT=HI,DEL= 0 : Display value > Setting value(AL) + Hysteresis (HYS) à(Relay on)
Display value <= Setting value(AL) - Hysteresis (HYS) à(Relay off)
◎When ACT=LO,DEL= 0 : Display value >= Setting value(AL) + Hysteresis (HYS) à(Relay off)
Display value < Setting value(AL) - Hysteresis (HYS) à(Relay on)
◎When ACT=HI,DEL= 1 ~ 99 sec.: Display value > Setting value(AL) + Hysteresis (HYS) + Delay time(DEL) à(Relay on)
Display value <= Setting value(AL) - Hysteresis (HYS) à(Relay off)
◎When ACT=LO,DEL= 1 ~ 99 sec.: Display value >= Setting value(AL) + Hysteresis (HYS) à(Relay off)
Display value < Setting value(AL) - Hysteresis (HYS) + Delay time(DEL) à(Relay on)
◎When ACT=HI,DEL= -1 ~ -99 sec.:Display value > Setting value(AL) + Hysteresis (HYS) à(Relay one shoot(DEL) and then off)
Display value <= Setting value(AL) - Hysteresis (HYS) à(Relay restore normal after the procedure)
◎When ACT=LO,DEL= -1~ -99 sec.:Display value >= Setting value(AL) + Hysteresis (HYS)à(Relay restore normal after the procedure)
Display value <
Setting value(AL)
-
Hysteresis (HYS)
à
(Relay one shoot(DEL) and then off)
Key Introduce Operation Manual
Key Function 1.In normal display,The key function is call out setting group
2.In parameter setting page,The key function is data Enter , and goto next page
Key Function 1.In normal display,The key function is call out alarm value setting page
2.Into parameter setting page,the parameter mark&data is alternate display,If need modify data can press
key into setting procedure,The display is lock parameter data,this time must let off key about 0.2
sec,press again,the cursor(twinkle express)is cycle moving left. (Key Response about 0.2 sec)
COM
IN
12V
Inside jumper
SW1
SW2
1
1
2
2
ON
ON
O
FF
O
FF
COM
IN
12V
Sensor
Inside jumper
SW1
SW2
1
1
2
2
O
FF
O
FF
O
FF
O
FF
4
3
2 1
SW1
4
3
2 1
SW
2
COM
IN
12V
COM
IN
12V
Sensor
Inside jumper
SW1
SW2
1
1
2
2
ON
ON
O
N
O
N
Inside jumper
SW1
SW2
1
1
2
2
ON
ON
O
FF
O
FF

Rev.00
Key Function 1.Into parameter setting page,the parameter mark&data is alternate display,If need modify data can
press
key into setting procedure,The display is lock parameter data,this time must let off key about
0.2 sec,press again,the parameter data will increment. (Key Response about 0.2 sec)
Key Function 1.In normal display,The key function is call out adjustment analog output AZERO&ASPAN page
2.Into parameter setting page,the parameter mark&data is alternate disp
lay,If need modify data can press
key into setting procedure,The display is lock parameter data,this time must let off key about 0.2
sec,press again the parameter data will decrement. (Key Response about 0.2 sec)
&
Key Function 1.In setting group or setting page press
&
key return normal display,but if in setting page the
modify data will be lost
No Key in anything 1.In setting group or setting page no key in anything about 2 minutes,return normal display,but if in
Setting page the modify data will be lost
Step Parameter Mark Description
Parameter Mark
Operation Manual
1
Normal display
Press
/FUNC key into P.CODE setting page
2
P.CODE(Pass code input
page)
1.Key in 5 digit pass code with
or
or
key
2.Press
key,the pass code is right into setting group , otherwise
return normal display
SYS(System setting group)
ROP(Alarm setting group)
DOP
(Communication setting group)
3
AOP
(Analog output setting group)
1.Select setting group with
key
2.Press
key into setting page of selection setting group
4
SYS(System setting group)
Press key decide SYS setting group , press key into D P1 setting
page
4-1
DP1(Decimal Point IN-1)
Default = 0
1.Decide decimal point IN-1 position with
or
key (0 to 4)
2.Press
key enter data and into DP2 setting page
4-2
DP2(Decimal Point IN-2)
Default = 0
3.Decide decimal point IN-2 position with
or
key (0 to 4)
4.Press
key enter data and into TYPE setting page
4-3
TYPE(Type)
Default = RPM
1.Decide Type with
or
key(RPM/LINE)
2.Press
key enter data and into PPR-A setting page
4-4
PPR-A(Pulse Per Revolution
of input A)
Default = 1
1.Decide pulse per revolution of input A with
&
&
key(1~99999)
2.Press
key enter data and into PPR-B setting page
4-5
PPR-B(Pulse Per Revolution
of input B)
Default = 1
1.Decide pulse per revolution of input B with
&
&
key(1~99999)
2.Press
key enter data and into MATH setting page
4-6
MATH(Math function of
Display 3)
Default = B-A
1.Decide Math function of Display 3 with or key
B-A [Display value of (B-A)]
(B+A)/2 [Display value of (B+A)/2]
(B/A)x100 [Display value of (B/A)*100]
(B/A-1)x100 [Display value of (B/A-1)*100]
(B/(A+B))x100 [Display value of (B/(A+B))*100]
(1-B/A)x100 [Display value of (1-B/A)*100]
2.Press key enter data and intoDP3 setting page
4-7
DP3(Decimal Point 3)
Default = 0
5.Decide decimal point 3 position with or key (0 to 4)
6.Press key enter data and into SCL-A setting page
4-8
SCL-A (Scale-A)
Default = 1.0000
1.Decide Scale-A with or or key (0.0001~9.9999)
2.Presskey enter data and into SCL-B setting page
Note:RPM(Scale = 0.0001~9.9999)
Line-Speed(rotation diameter = 0.0001~9.9999M)
4-9
SCL-B (Scale-B)
Default = 1.0000
1.Decide Scale-B with or or key (0.0001~9.9999)
2.Presskey enter data and into TBASE setting page
Note:RPM(Scale = 0.0001~9.9999)
Line-Speed(rotation diameter = 0.0001~9.9999M)
4-10
TBASE (Sampling Time
Base)
Default = 0.1
1.Decide sampling time base with
&
&
key(0.1~99.9sec)
2.Press
key enter data and into AVG setting page

Rev.00
4-11
AVG (Display Average
times)
Default = 5
1.Decide display average times with
&
&
key(1~99)
2.Press
key enter data and into CODE setting page
4-12
CODE(Pass Code)
Default = 0
1.Decide pass code with
&
&
key(0~99999)
2.Press
key enter data and into LOCK setting page
4-13
LOCK(Panel Lock)
Default = NO
1.Decide panel lock with
&
key(NO or YES)
2.Press
key enter data and return SYS setting group
5
ROP(Alarm output setting
group)
Press key decide ROP setting group,press key into AL1-S setting
page
5-1
AL1-S(Alarm 1 Select)
Default = DISP1
1.Decide Alarm 1 Select with or key(DISP1,DISP2,DISP3)
2.Press key enter data and into ACT1 setting page
5-2
ACT1(Alarm Active 1)
Default = HI
1.Decide Alarm Active 1 with or key(HI or LO)
2.Press key enter data and into HYS1 setting page
5-3
HYS1(Alarm Hysteresis 1)
Default = 0
1.Decide Alarm Hysteresis 1 with or or key(0~999)
2.Press key enter data and into DEL1 setting page
5-4
DEL1(Alarm Delay 1)
Default = 0
1.Decide Alarm Delay 1 with or or key(-99~99 sec)
2.Press key enter data and into AL2-S setting page
Note: -1 ~ -99 sec = Alarm active time, 1 ~ 99 sec = Alarm delay time
5-5
AL2-S(Alarm 2 Select)
Default = DISP2
1.Decide Alarm 2 Select with or key(DISP1,DISP2,DISP3)
2.Press key enter data and into ACT2 setting page
5-6
ACT2(Alarm Active 2)
Default = HI
1.Decide Alarm Active 2 with or key(HI or LO)
2.Press key enter data and into HYS2 setting page
5-7
HYS2(Alarm Hysteresis 2)
Default = 0
1.Decide Alarm Hysteresis 2 with or or key(0~999)
2.Press key enter data and into DEL2 setting page
5-8
DEL2(Alarm Delay 2)
Default = 0
1.Decide Alarm Delay 2 with or or key(-99~99 sec)
2.Press key enter data and into AL3-S setting page
Note: -1 ~ -99 sec = Alarm active time, 1 ~ 99 sec = Alarm delay time
5-9
AL3-S(Alarm 3 Select)
Default = DISP3
1.Decide Alarm 3 Select with or key(DISP1,DISP2,DISP3)
2.Press key enter data and into ACT3 setting page
5-10
ACT3(Alarm Active 3)
Default = HI
1.Decide Alarm Active 3 with or key(HI or LO)
2.Press key enter data and into HYS3 setting page
5-11
HYS3(Alarm Hysteresis 3)
Default = 0
1.Decide Alarm Hysteresis 3 with or or key(0~999)
2.Press key enter data and into DEL3 setting page
5-12
DEL3(Alarm Delay 3)
Default = 0
1.Decide Alarm Delay 3 with or or key(-99~99 sec)
2.Press key enter data and into AL4-S setting page
Note: -1 ~ -99 sec = Alarm active time, 1 ~ 99 sec = Alarm delay time
5-13
AL4-S(Alarm 4 Select)
Default = DISP1
1.Decide Alarm 4 Select with or key(DISP1,DISP2,DISP3)
2.Press key enter data and into ACT4 setting page
5-14
ACT4(Alarm Active 4)
Default = HI
1.Decide Alarm Active 4 with or key(HI or LO)
2.Press key enter data and into HYS4 setting page
5-15
HYS4(Alarm Hysteresis 4)
Default = 0
1.Decide Alarm Hysteresis 4 with or or key(0~999)
2.Press key enter data and into DEL4 setting page
5-16
DEL4(Alarm Delay 4)
Default = 0
1.Decide Alarm Delay 4 with or or key(-99~99 sec)
2.Press key enter data and return ROP setting group
Note: -1 ~ -99 sec = Alarm active time, 1 ~ 99 sec = Alarm delay time

Rev.00
6
DOP(Communication setting
group)
press
key decide DOP setting group,press
key into ADDR setting
page
6-1
ADDR(Communication –
Address setting page )
Default = 0
1.Decide address with
or
or
key(0~255)
2.Press
key enter data and into BAUD setting page
6-2
BAUD(Communication Baud
Rate setting page)
Default = 19200
1.Decide baud rate with
or
key(38400,19200,9600,4800,2400)
2.Press
key enter data and into PARI setting page
6-3
PARI(Communication Parity
Check setting page)
Default = n82
1.Decide parity check with
or
key(n82,n81,even,odd)
2.Press
key enter data and return DOP setting group
7
AOP(Analog output setting
group)
Press
key decide AOP setting group , press
key into AO.SEL
setting page
7-1
AO.SEL(Analog Output
Select)
Default = DISP3
1.Decide Analog Output Select with or key(DISP1,DISP2,DISP3)
2.Press key enter data and into ANLO setting page
7-2
ANLO(A/O Zero According
to Display setting page)
Default = 0
1.Decide A/O Zero According to Display with
or
or
key
(-19999~99999)
2.Press
key enter data and into ANHI setting page
7-3
ANHI(A/ O Span According
to Display setting page)
Default =10000
1.Decide A/ O Span According to Display with
or
or
key
(-19999~99999)
2.Press
key enter data and return AOP setting group
Step Parameter mark description Parameter mark
Operation manual
8
Normal display
Press
/ALARM key about 3 sec,into AL1 setting page
8-1
AL1 (Alarm 1)
Default = 0
1.Decide Alarm 1 with or or key(-19999~99999)
2.Press key enter data and into AL2 setting page
8-2
AL2 (Alarm 2)
Default = 0
1.Decide Alarm 2 with or or key(-19999~99999)
2.Press key enter data and into AL3 setting page
8-3
AL3(Alarm 3)
Default = 0
1.Decide Alarm 3 with or or key(-19999~99999)
2.Press key enter data and into AL4 setting page
8-4
AL4(Alarm 4)
Default = 0
1.Decide Alarm 4 with or or key(-19999~99999)
2.Press key enter data and return normal display
Step Parameter mark description Parameter mark
Operation manual
9
Normal display
Press
/A-ADJkey about 3 sec,into AZERO adjustment page
9-1
AZERO(Analog Output
Zero Adjustment page)
Default = 0
1.Adjustment analog output zero with
or
or
key(±6000)
2.Press
key enter data and into ASPAN adjustment page
9-2
ASPAN(Analog Output
Span Adjustment page)
Default = 0
1.Adjustment analog output span with
or
or
key(±6000)
2.Press
key enter data and return normal display
Appendix
Error Mark description Error Mark Analyze & Description
1
Input over range error detect
Input signal over the maximum input range (0~25KHz)
2
Display over range error detect
Input signal over the maximum display range (99999)
3
Display under range error detect
Input signal under the minimum display range (-19999)
4
EEPROM error detect
1.External interference when EEPROM read/write
2.EEPROM write over 1 million times(guarantee 10 years)
Please power reset,if still display E-00,doing following step:
1.E-00 & No alternate display for inquire reset EEPROM
2.Decide Yes with or key,press key return n ormal display
3.EEPROM was reset,Please follow step 1~9 set again

Rev.00
MMRD-M Modbus RTU Mode Protocol Address Map
Data format 16Bit/32Bit, sign bit 8000~7FFF(-32768~32767), 80000000~7FFFFFFF(-2147483648~2147483647)
Address
Name Description Accept
0000
DP1 IN-1 Decimal Point, Input Range 0000~0004(0~4)(0:100,1:10-1,2:10-2,3:10-3,4:10-4) R/W
0001
DP2 IN-2 Decimal Point, Input Range 0000~0004(0~4)(0:100,1:10-1,2:10-2,3:10-3,4:10-4) R/W
0002
DP3 Display 3 Decimal Point, Input Range 0000~0004(0~4)(0:100,1:10-1,2:10-2,3:10-3,4:10-4) R/W
0003
TYPE
Input Type, Input Range 0000~0001(0~1)(0:RPM,1:LINE) R/W
0004
LOCK
Panel Lock, Input Range 0000~0001(0~1)(0:NO,1:YES) R/W
0005
MATH
Math function of Display 3
,
Input Range
0000~0005(0~5)(0:B-A,1:(B+A)/2,2:(B/A)x100,
3:(B/A-1)x100,4:(B/(A+B))x100,5:(1-B/A)x100) R/W
0006
AL1-S
Alarm 1 Select
,
Input Range
0000~0002(0~2)(0:DISP1,1:DISP2,2:DISP3)
R/W
0007
AL2-S
Alarm 2 Select
,
Input Range
0000~0002(0~2)(0:DISP1,1:DISP2,2:DISP3)
R/W
0008
AL3-S
Alarm 3 Select
,
Input Range
0000~0002(0~2)(0:DISP1,1:DISP2,2:DISP3)
R/W
0009
AL4-S
Alarm 4 Select
,
Input Range
0000~0002(0~2)(0:DISP1,1:DISP2,2:DISP3)
R/W
000A
ACT1
Alarm Active 1,Input Range 0000~0001(0~1)(0:HI,1:LO) R/W
000B
ACT2
Alarm Active 2,Input Range 0000~0001(0~1)(0:HI,1:LO) R/W
000C
ACT3
Alarm Active 3,Input Range 0000~0001(0~1)(0:HI,1:LO) R/W
000D
ACT4
Alarm Active 4,Input Range 0000~0001(0~1)(0:HI,1:LO) R/W
000E
HYS1
Alarm Hysteresis 1,Input Range 0000~03E7(0~999) R/W
000F
HYS2
Alarm Hysteresis 2,Input Range 0000~03E7(0~999) R/W
0010
HYS3
Alarm Hysteresis 3,Input Range 0000~03E7(0~999) R/W
0011
HYS4
Alarm Hysteresis 4,Input Range 0000~03E7(0~999) R/W
0012
DEL1
Alarm Delay 1,Input Range FF9D~0063(-99~99) R/W
0013
DEL2
Alarm Delay 2,Input Range FF9D~0063(-99~99) R/W
0014
DEL3
Alarm Delay 3,Input Range FF9D~0063(-99~99) R/W
0015
DEL4
Alarm Delay 4,Input Range FF9D~0063(-99~99) R/W
0016
ADDR
Communication Address, Input Range 0000~00FF(0~255) R/W
0017
BAUD
Communication Baud Rate, Input Range 0000~0004(0~4)(0:38400,1:19200,2:9600,3:4800,4:2400) R/W
0018
PARI Communication Parity Check, Input Range 0000~0003(0~3)(0:N82,1:N81,2:EVEN,3:ODD) R/W
0019
AO.SEL
Analog Output Select, Input Range 0000~0002(0~2)
(0:DISP1,1:DISP2,2:DISP3)
R/W
001A
TBASE
Sampling Time Base, Input Range 0001~03E7(1~999) R/W
001B
AVG Display Average times, Input Range 0001~0063(1~99) R/W
001C
A_ZERO
Analog Output Zero Adjust, Input Range E890~1770(-6000~6000) R/W
001D
A_SPAN
Analog Output Span Adjust, Input Range E890~1770(-6000~6000) R/W
001E
CODE
Pass Code, Input Range 00000000~0001869F(0~99999)high word R/W
001F
Pass Code, Input Range 00000000~0001869F(0~99999)low word R/W
0020
SCL-A
Scale-A, Input Range 00000001~0001869F(1~99999)high word R/W
0021
Scale-A, Input Range 00000001~0001869F(1~99999)low word R/W
0022
SCL-B
Scale-B, Input Range 00000001~0001869F(1~99999)high word R/W
0023
Scale-B, Input Range 00000001~0001869F(1~99999)low word R/W
0024
PPR-A
Pulse Per Revolution
of input A
, Input Range 00000001~0001869F
(1~9
9999)
high word
R/W
0025
Pulse Per Revolution of input A, Input Range 00000001~0001869F(1~99999) low word R/W
0026
PPR-B
Pulse Per Revolution of input B, Input Range 00000001~0001869F(1~99999) high word R/W
0027
Pulse Per Revolution of input B, Input Range 00000001~0001869F(1~99999) low word R/W
0028
AL1 Alarm value 1,Input Range FFFFB1E1~0001869F(-19999~99999)high word R/W
0029
Alarm value 1,Input Range FFFFB1E1~0001869F(-19999~99999)low word R/W
002A
AL2 Alarm value 2,Input Range FFFFB1E1~0001869F(-19999~99999)high word R/W
002B
Alarm value 2,Input Range FFFFB1E1~0001869F(-19999~99999)low word R/W
002C
AL3 Alarm value 3,Input Range FFFFB1E1~0001869F(-19999~99999)high word R/W
002D
Alarm value 3,Input Range FFFFB1E1~0001869F(-19999~99999)low word R/W
002E
AL4 Alarm value 4,Input Range FFFFB1E1~0001869F(-19999~99999)high word R/W
002F
Alarm value 4,Input Range FFFFB1E1~0001869F(-19999~99999)low word R/W
0030
ANLO
Analog Output Zero According to Display, Input Range FFFFB1E1~0001869F(-19999~99999)high word R/W
0031
Analog Output Zero According to Display, Input Range FFFFB1E1~0001869F(-19999~99999)low word R/W
0032
ANHI
Analog Output Span According to Display, Input Range FFFFB1E1~0001869F(-19999~99999)high word R/W
0033
Analog Output Span According to Display, Input Range FFFFB1E1~0001869F(-19999~99999)low word R/W
0034
DISP1
IN1 Display Value, Display Range 00000000~0001869F(0~99999)high word R
0035
IN1 Display Value, Display Range 00000000~0001869F(0~99999)low word R
0036
DISP2
IN2 Display Value, Display Range 00000000~0001869F(0~99999)high word R
0037
IN2 Display Value, Display Range 00000000~0001869F(0~99999)low word R
0038
DISP3
Math Display 3, Display Range FFFFB1E1~0001869F(-19999~99999)high word R
0039
Math Display 3, Display Range FFFFB1E1~0001869F(-19999~99999)low word R
003A
STATUS
Display & Alarm Status, Range
0000~03FF(0~1023)Bit0:AL1,Bit1:AL2,Bit2:AL3,Bit3:AL4,Bit4:DISP1 DOFL
,Bit5:DISP1 IOFL,Bit6:DISP2 DOFL,Bit7:DISP2 IOFL,Bit8:DISP3 DOFL,Bit9:DISP3 -DOFL
R
Other AXE Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

IFM Electronic
IFM Electronic efector300 SD6101 operating instructions

Blizzard
Blizzard Pocket Rocket II quick start guide

Siemens
Siemens SITRANS F MAG 6000 I operating instructions

Martel
Martel PTC8010 Reference manual

E+E Elektronik
E+E Elektronik OMNIPORT 20 manual

socomec
socomec DIRIS A20 operating instructions