Rev.1.0
2
Key Introduce Operation Manual
Key Function1.In normal display,The key function is call out setting group
2.In parameter setting page,The key function is data Enter , and goto next page
Key Function1
.Into parameter setting page,the parameter mark&data is alternate display,If need modify data can
press key into setting procedure,The display is lock parameter data,this time must let off key
about 0.2 sec,press again,the cursor(twinkle express)is cycle moving left. (Key Response about
0.2 sec)
Key Function1.Into parameter setting page,the parameter mark&data is alternate display,If n
press key into setting procedure,The display is lock parameter data,this time must let off key
about 0.2 sec,press again,the parameter data will increment. (Key Response about 0.2 sec)
D-S Key Function 1.In normal display, the main function is to switch between the Rate and the Totalizer display
(press the D-S button to change the page once)
No Key in anything 1.In setting page no key in anything about 2 minutes,return normal display,but if in Setting page
the modify data will be lost
Step Parameter Mark Description
Parameter Mark
Operation Manual
1
Normal display
Press key intoP.CODE setting page
2
P.CODE
(Pass code input page)
Default=0
1.Key in 5 digit pass code with orkey
2.Press key,the pass code is right into DPR page, otherwise
return normal display
3
DPR(Decimal Point Rate
setting page)Default=0
1.Decide rate decimal point position withkey(0 to 4)
2.Presskey enter data and into DSPH setting page
4
DSPH(Display High Scale
setting page)Default=10000
1.Decide rate display high scale with&key(0 to 99999)
2.Presskey enter data and into INHI setting page
5
INHI(Input Max. Hz)
Default=999.99
1.Decide input max. Hz with&key(0.01 to 999.99Hz)
2.Presskey enter data and into AVG setting page
6
AVG (Dispaly Average time
setting page)Default=1
1.Decide display average times with&key(1 to 99)
2.Presskey enter data and into TBASE setting page
7
TBASE(Time Base)
Default=1
1.Decide time base with&key(1 to 99)
2.Presskey enter data and into DPT setting page
8
DPT (Decimal Point Totalizer
setting page)Default=0
1.Decide totalizer decimal point position withkey(0 to 4)
2.Presskey enter data and into C.TIME setting page
9
C.TIME (Count Time)
Default=1
1.Decide C.TIME withkey(1/60/3600 sec)
2.Presskey enter data and into SCALE setting page
10
SCALE (Scale to totalize
setting page)Default=1.0000
1.Decide Totalize scale with&key(0.0001 to 9999.9999)
2.Presskey enter data and into CODE setting page
11
CODE(Pass Code setting
page)Default=0
1.Decide pass code with&key(0 to 99999)
2.Presskey enter data and into LOCK setting page
12
LOCK(Panel Lock setting
page)Default=NO
1.Decide panel lock withkey(NO or YES)
2.Presskey enter data and return Normal display page
Appendix
Error Mark Description
Error Mark Analyze & Description
1
Input over error detect
Input frequency over range(1KHz)
2
Display over error detect
Display over range(99999)
3
EEPROM error detect
1.External interference when EEPROM read/write
2.EEPROM write over 100000 times(guarantee 10 years)
Please power reset,if still display E-00,doing following step:
1.E-00 & No alternate display for inquire reset EEPROM
2.Decide Yes withkey,presskey return normal display
3.EEPROM was reset,Please follow step 1~12 set again